• Title/Summary/Keyword: Connection reliability

Search Result 341, Processing Time 0.032 seconds

A Study on the Priority Decision for Interconnection of PV System on Power Distribution System considering Customer Interruption Costs (정전비용 고려한 PV시스템의 배전계통 연계 우선순위 결정에 관한 연구)

  • Son, Chang-Nam;Han, Woon-Dong;Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.163-168
    • /
    • 2014
  • In this paper, when photovoltaic systems are connected to distribution system, most effective capacity and location of PV system are studied considering customer interruption costs of power distribution system. The reliability model of PV system considering the duration of sunshine, the model of time-varying load and Roy Billinton test system (bus2 model) are used. To simulate the effects of PV system, various cases are selected; (1) base case which is no connection of PV system to power distribution system when faults are occurred, (2) 3MW case which is 3[MW] connection of PV system (3) 4[MW] case, and (4) 20[MW] case which is 20[MW] connection of PV system to the bus of power distribution system. The capacity limit of connected PV system is settled to 14[MW] for all cases except case 4. The reliability and customer interruption costs for residential, general, industrial, and educational customer is evaluated.

자동차엔진의 품질보증데이터 분석

  • Uk, Baek-Jae
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2004.07a
    • /
    • pp.183-190
    • /
    • 2004
  • Found important components in terms of frequency in the assembly (but not in terms of money). Component 39*** was most important. The failure mode was N69(no light on warning signal the cause of the failure was C15(bad connection). Formed a population for each component. Performed reliability and warranty cost analyses At the component level. At the subsystem level. At the system level. **They don'l trust the warranty cost analysis.** Reliability improvement. Among all the subsystems front \ulcorner subsystem is most vulnerable (among other things due to the large number of components in it), especially components 39*** and 28***.

  • PDF

Optimality in Designs of Experiment

  • Choi Kuey-Chung
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2005.06a
    • /
    • pp.109-113
    • /
    • 2005
  • Optimality for block designs have received much attention in the literature. Here we review these criteria and present results showing their A,D and E connection. Also we acquainted with the mathematical methods of designing optimal experiments. In this paper, we will to do work about optimality in experimental designs.

  • PDF

Reliability Paradigm-Changes in Industry 4.0 (4차 산업혁명 시대에서의 신뢰성 패러다임의 변화)

  • Jeong, Hai Sung
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.289-295
    • /
    • 2017
  • Purpose: This paper will focus on the reliability technological innovation following the emergence of industry 4.0 featured by convergence, connection and complexity. In the course of the process, the concept and application of 3R (Robustness, Redundancy, Resilience) are considered along with reliability in industry 4.0. Methods: Reliability paradigm-changes are presented to meet the purpose of keeping the desired function in Industry 4.0. And the introduction of resilience, a concept compromising reliability is to be suggested. Results: The necessity of the 3R (Robustness, Redundancy, Resilience) introduction is emphasized according to reliability paradigm-changes. Conclusion: Reliability, robustness, redundancy and resilience are not mutually exclusive. Ultimately, acquiring the resilience requires robustness, redundancy and fittable maintenance procedures.

A Simplified Steel Beam-To-Column Connection Modelling Approach and Influence of Connection Ductility on Frame Behaviour in Fire

  • Shi, Ruoxi;Huang, Shan-Shan;Davison, Buick
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.343-362
    • /
    • 2018
  • A simplified spring connection modelling approach for steel flush endplate beam-to-column connections in fire has been developed to enable realistic behaviour of connections to be incorporated into full-scale frame analyses at elevated temperature. Due to its simplicity and reliability, the proposed approach permits full-scale high-temperature frame analysis to be conducted without high computational cost. The proposed simplified spring connection modelling approach has been used to investigate the influence of connection ductility (both axial and rotational) on frame behaviour in fire. 2D steel and 3D composite frames with a range of beam spans were modelled to aid the understanding of the differences in frame response in fire where the beam-to-column connections have different axial and rotational ductility assumptions. The modelling results highlight that adopting the conventional rigid or pinned connection assumptions does not permit the axial forces acting on the connections to be accurately predicted, since the axial ductility of the connection is completely neglected when the rotational ductility is either fully restrained or free. By accounting for realistic axial and rotational ductilities of beam-to-column connections, the frame response in fire can be predicted more accurately, which is advantageous in performance-based structural fire engineering design.

A Study on Reliability (신뢰성에 관한 고찰)

  • 이근희
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.2 no.2
    • /
    • pp.1-4
    • /
    • 1979
  • In order to cope with the violent environment of surrounding enterprises, development of new products, advance to other industry field, unification or abolition of factories and rationlization of labor are needed. But production process being made quality and using process after shipment are the things that we have to think about, first of all and to practice always. Insurance problem of reliability, that is, the positive quality maintenance that has being presented many debate issues recently, will be studied. The accident of nuclear power-plant in America, in connection with reliability maintenance and human engineering, will be analyzed. But as its accident details is not announced, in this study, it is a sort of method of methodology to be studied this paper rather than studying the fact of the accident. Therefore this study will be done as follows, For reliability study. 1. Investigation of problems. 2. Quality maintenance activity and reliability maintenance activity 3. Reliability acquisition in production process, 4. Reliability maintenance after shipment. 5. Conclusion. In addition to stating above, it is sure that liberalization of trade, interchange between nations and strengthening of international competition ability, etc. need high quality. But possibility that quality maintenance or reliability aquisition needs understanding and cooperation of consumer, will be stated.

  • PDF

Study on Reliability Analysis of Passenger Car Equipments and Maintenance Connection Plan (일반객차의 장치별 신뢰도 분석과 유지보수 연계방안 연구)

  • Kim, Ju-Won;Kim, Ho-Soon;Yu, Yang-Ha;Jo, Jae-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1357-1365
    • /
    • 2011
  • Reliability analysis-based maintenance system has the merit than elapsed time-based preventive maintenance system. First, it is possible to active handling of rolling stocks failures. In the past, Failure handling activities began when after increase failures rapidly. But if we can continuous manage of reliability than changing of failure tendency can know more quickly. Second, It is possible to using maintenance resources effectively. We can look forward to cost reduction to distributing of much less failures parts's maintenance resources. KORAIL builds reliability system called KTX-RCM for operating high-speed rolling stocks. But existing rolling stocks have not reliability system from the past. Fortunately, KORAIL started ERP system called KOVIS at 2007. KOVIS includes maintenance data for reliability analysis. So in this study analysis failure data for getting reliability number about existing passenger car. And we desire to maintenance connection plan.

  • PDF

Anisotropic Conductive Film (ACF) Prepared from Epoxy/Rubber Resins and Its Fabrication and Reliability for LCD

  • Kim, Jin-Yeol;Kim, Eung-Ryul;Ihm, Dae-Woo
    • Journal of Information Display
    • /
    • v.4 no.1
    • /
    • pp.17-23
    • /
    • 2003
  • A thermoset type anisotropic conductive adhesive film (ACAF) comprising epoxy resin and natural butyl rubber (NBR) as the binder, micro-encapsulated imidazole as the curing agent, and Ni/Au coated polymer bead as a conductive particle has been studied. These films have been prepared to respond to requirements such as improved contact resistance, current status less of than 60 ${\mu}m$ and reliability. These films can also be used for connection between the ITO glass for LCD panel and the flexible circuit board. The curing conditions for the connection were 40, 20 and 15 seconds at 150, 170 and 190 $^{\circ}C$, respectively. The initial contact resistance and adhesion strength were 0.5 ${\Omega}/square$ and 0.4 kg/cm under the condition of 30 kgf/$^{cm}^2}$, respectively. After completing one thousand thermal shock cycling tests between -15 $^{\circ}C$ and 100 $^{\circ}C$, the contact resistance was maintained below 0.7 ${\Omega}/square$. Durability against high temperature (80$^{\circ}C$) and high humidity (85 % RH) was also tested to confirm long-term stability (1000 hrs) of the conduction.

Loosening behavior of Internal and External Connection Dental Implants under Cyclic Loads Considering Pre-fastening Force (체결력을 고려한 내부 및 외부연결형 임플란트의 반복 하중에 대한 풀림 연구)

  • Lee, Yongwoo;Jang, Yong Hoon
    • Tribology and Lubricants
    • /
    • v.37 no.4
    • /
    • pp.136-143
    • /
    • 2021
  • This paper presents the loosening behavior that occurs after the application of an external load to internal and external connection types of dental implants using the finite element method. We use fastening force between an abutment and a fixture to clamp the dental implant system; however, loosening and breakage may occur owing to cyclic external loads. In this study, we considered the initial fastening condition in the pre-load analysis and then investigated the change in stress and contact surface status when applying external loads. After the application of the initial fastening load, we verified that the internal connection-type model exhibited a relatively lower stress distribution than that of the external connection-type one. Moreover, we found that the former model showed a lower stress concentration after the application of the external load. In addition, after the application of this load, we found that the higher the shear load acting on the implant system, the higher the possibility of loosening. The study results showed the change in stress distribution and contact surface according to the connection type of the dental implants and the phenomenon of loosening by cyclic loads. We expect that the results of this study will be useful for the study of reliability and design of dental implant systems.

A Study on the Reliability of Superconducting Fault Current Limiter and Adjacent Distribution Equipments (초전도한류기와 인근 배전설비의 신뢰도에 관한 연구)

  • Bae, In-Su;Kim, Sung-Yul;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2122-2127
    • /
    • 2009
  • This study presents the failure rate and repair rate of Superconducting Fault Current Limiter(SFCL) and adjacent distribution equipments. When the fault current penetrated SFCL, the supply of electric power to the customers can be partly continued. It is expected that SFCL makes to improve the reliability index of customers. Contrary to the expectations, the series connection between SFCL and distribution system could deteriorate the reliability index. To evaluate the reliability index in the distribution system including SFCL, the failure rate and repair rate of SFCL are required as well as that of distribution equipments. Also, the insertion of SFCL makes to change the failure rate and repair rate of adjacent equipments. This study proposes a method to calculate the failure rate and repair rate of a component combining SFCL and adjacent equipments.