태양전지 실리콘 웨이퍼에서의 레일리기준 기반 레이저산란 패턴 분석 및 결함 검출 (Investigation of Laser Scattering Pattern and Defect Detection Based on Rayleigh Criterion for Crystalline Silicon Wafer Used in Solar Cell)

  • 연정승;김경범
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.606-613
    • /
    • 2011
  • In this paper, patterns of laser scattering and detection of micro defects have been investigated based on Rayleigh criterion for silicon wafer in solar cell. Also, a new laser scattering mechanism is designed using characteristics of light scattering against silicon wafer surfaces. Its parameters are to be optimally selected to obtain effective and featured patterns of laser scattering. The optimal parametric ranges of laser scattering are determined using the mean intensity of laser scattering. Scattering patterns of micro defects are investigated at the extracted parameter region. Among a lot of pattern features, both maximum connected area and number of connected component in patterns of laser scattering are regarded as the important information for detecting micro defects. Their usefulness is verified in the experiment.

새로운 고효율 계통연계 1kW 연료전지용 PCS (A Noval High Efficiency Grid Connected 1kW PCS for Fuel Cell)

  • 김태진
    • 한국수소및신에너지학회논문집
    • /
    • 제19권5호
    • /
    • pp.417-422
    • /
    • 2008
  • In this paper, a novel DC/DC low-voltage high-current converter circuit is proposed to improve the efficiency of power converter used in the grid-connected fuel-cell generator system. We proposed a novel high efficiency grid-connected power conditioning system for RPG fuel cell. On the result of that, the loss of system was decreased rapidly by driving stack within the condition of maximum efficiency. The peak currents of the current-type inductor and the transformer's coil are reduced by synchronizing switching frequency of Buck-type converter is increased twice as the Push-Pull converter's switching frequency. The novel structure of DC/DC converter is able to realize ZVS-ZCS in fuel-cell system is proposed. The proposed switching component of Push-Pull converter has the ZVS and ZCS function by using the circuit of new passive clamp.

자동차번호판 자동인식을 위한 문자추출에 관한 연구 (A Study on Character Extraction Algorithm for Vehicle License Plate Recognition)

  • 김재광;최환수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.965-967
    • /
    • 1995
  • One of the most difficult tasks in the process of automatic vehicle license plate recognition is the extraction of each character from within license plate region. In many cases, characters, especially serial numbers of plates are connected together due to noise and plate accessories. The recognition process may not be successful without extracting these characters effectively. This paper presents an algorithm to extract these connected characters very effectively. The algorithm utilizes mathematical morphology, connected component analysis, and gradient filters for character extraction. The paper also presents thorough experimental results as well as details of the algorithm.

  • PDF

An Interleaving Scheme for DC-link Current Ripple Reduction in Parallel-Connected Generator Systems

  • Jeong, Min-Gyo;Shin, Hye Ung;Baek, Ju-Won;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1004-1013
    • /
    • 2017
  • This paper presents an interleaving scheme for parallel-connected power systems to reduce the DC-link current ripple. A paralleled generator system generates current ripple by the Pulse Width Modulation (PWM) of each generator side converter. The current ripple in the DC-link degrades the efficiency of the whole generator system and decreases the lifetime of the DC-link capacitors. To mitigate these issues, the expression of the DC-link current is derived by a double-integral Fourier analysis while considering the modulation schemes. Optimized interleaving angles for the parallel generator system are obtained based on an analysis to minimize the dominant current harmonics component. Finally, the proposed interleaving scheme reduces the RMS value of the DC-link current ripple. Simulation and experimental results verify the effectiveness of the proposed interleaving scheme.

Analytical and Experimental Validation of Parasitic Components Influence in SiC MOSFET Three-Phase Grid-connected Inverter

  • Liu, Yitao;Song, Zhendong;Yin, Shan;Peng, Jianchun;Jiang, Hui
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.591-601
    • /
    • 2019
  • With the development of renewable energy, grid-connected inverter technology has become an important research area. When compared with traditional silicon IGBT power devices, the silicon carbide (SiC) MOSFET shows obvious advantages in terms of its high-power density, low power loss and high-efficiency power supply system. It is suggested that this technology is highly suitable for three-phase AC motors, renewable energy vehicles, aerospace and military power supplies, etc. This paper focuses on the SiC MOSFET behaviors that concern the parasitic component influence throughout the whole working process, which is based on a three-phase grid-connected inverter. A high-speed model of power switch devices is built and theoretically analyzed. Then the power loss is determined through experimental validation.

COUNTING OF FLOWERS BASED ON K-MEANS CLUSTERING AND WATERSHED SEGMENTATION

  • PAN ZHAO;BYEONG-CHUN SHIN
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제27권2호
    • /
    • pp.146-159
    • /
    • 2023
  • This paper proposes a hybrid algorithm combining K-means clustering and watershed algorithms for flower segmentation and counting. We use the K-means clustering algorithm to obtain the main colors in a complex background according to the cluster centers and then take a color space transformation to extract pixel values for the hue, saturation, and value of flower color. Next, we apply the threshold segmentation technique to segment flowers precisely and obtain the binary image of flowers. Based on this, we take the Euclidean distance transformation to obtain the distance map and apply it to find the local maxima of the connected components. Afterward, the proposed algorithm adaptively determines a minimum distance between each peak and apply it to label connected components using the watershed segmentation with eight-connectivity. On a dataset of 30 images, the test results reveal that the proposed method is more efficient and precise for the counting of overlapped flowers ignoring the degree of overlap, number of overlap, and relatively irregular shape.

컴포넌트 개조 지원 도구의 설계 및 구현 (Design and Implementation of Component Adaptation Supporting Tool)

  • 김정아;권오천;최유희;신규상;윤심
    • 정보처리학회논문지D
    • /
    • 제9D권5호
    • /
    • pp.903-914
    • /
    • 2002
  • 본 연구에서는 컴포넌트의 개조에 필요한 기법과 이를 지원하는 도구를 개발하였다. 컴포넌트를 재사용 하거나 조림하는 과정 중에 컴포넌트의 개조가 필요하게 되는데, 이는 컴포넌트의 인터페이스가 조립하고자 하는 다른 컴포넌트와 다른 경우가 많기 때문이다. 가끔은 새로운 요구 사항에 의해 추가적인 속성의 정의가 필요한 경우도 생기게 된다. 그러므로 컴포넌트의 재사용과 조립에는 컴포넌트 개조의 과정이 필수적이다. 본 연구에서는 컴포넌트 개조를 지원하기 위해서 바이너리 컴포넌트 개조 기법과 개조 컴포넌트에 의한 개조 기법을 제안하였다. 또한 효과적 개조 과정 지원을 위해 개조 지원 도구를 개발하였다. 이로써 소스코드가 없는 기존의 컴포넌트를 개조하여 새로운 요구 사항에 부합되지 못하거나 기존의 다른 컴포넌트와 조립에 문제가 있는 컴포넌트를 쉽게 개조할 수 있도록 지원하였다.

시뮬레이티드 어닐링을 이용한(m, n)중 연속(r,s) : F 시스템의 정비모형 (A Maintenance Design of Connected-(r, s)-out-of-(m, n) F System Using Simulated Annealing)

  • 이상헌;강영태;신동열
    • 대한산업공학회지
    • /
    • 제34권1호
    • /
    • pp.98-107
    • /
    • 2008
  • The purpose of this paper is to present an optimization scheme that aims at minimizing the expected cost per unittime. This study considers a linear connected-(r, s)-ouI-of-(m, n):f lattice system whose components are orderedlike the elements of a linear (m, n)-matrix. We assume that all components are in the state 1 (operating) or 0(failed) and identical and s-independent. The system fails whenever at least one connected (r, s)-submatrix offailed components occurs. To find the optimal threshold of maintenance intervention, we use a simulatedannealing(SA) algorithm for the cost optimization procedure. The expected cost per unit time is obtained byMonte Carlo simulation. We also has made sensitivity analysis to the different cost parameters. In this study,utility maintenance model is constructed so that minimize the expense under full equipment policy throughcomparison for the full equipment policy and preventive maintenance policy. The full equipment cycle and unitcost rate are acquired by simulated annealing algorithm. The SA algorithm is appeared to converge fast inmulti-component system that is suitable to optimization decision problem.

Monitoring and Analysis of 3kW Grid-Connected PV System for Performance Evaluation

  • So Jung-Hun;Jung Young-Seok;Yu Gwon-Jong;Choi Ju-Yeop;Choi Jae-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.57-62
    • /
    • 2005
  • Grid-connected photovoltaic (PV) systems were installed and monitored at the field demonstration test center (FDTC) in Korea in October 2002. Before long-term field testing of installed PV systems, the performances of PV components were evaluated and compared through short-term performance tests of each of the PV system components such as power conditioning system and PV module under standard test conditions. A data acquisition system has been constructed for measuring and analyzing the performance of PV systems to observe the overall effect of environmental conditions on their operation characteristics. Performances of PV systems have been evaluated and analyzed not only for component perspective (PV array, power conditioning unit) but also for global perspective (system efficiency, capacity factor, electrical power energy) by review of the field test and loss factors of the systems. These results indicate that it is highly imperative to develop an optimum design technology of grid connected PV systems. The objective of this paper is not only to evaluate and analyze the performance of domestic PV systems application through long-term field testing at FDTC but also to develop evaluation, analysis and optimum technology for long-term stability and reliability of grid-connected PV systems in Korea.

3kW급 계통연계형 태양광발전시스템의 성능특성 비교분석에 관한 연구 (A Study on Performance Analysis of 3kW Grid-Connected PV Systems)

  • 소정훈;최주엽;유권종;정영석;최재호
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.9-15
    • /
    • 2004
  • 3kW grid connected PV(photovoltaic) systems have been constructed for evaluating and analyzing performance of PV system at FDTC(field demonstration test center) in Korea, PV systems installed in FDTC have been operating and monitored since November 2002. As climatic and irradiation conditions have been varied through long-term field test, data acquisition system has been constructed for measuring performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV systems has been evaluated and analyzed for component perspective(PV array and power conditioning system) and global perspective(system efficiency, capacity factor, and electrical power energy) by field test. By the results, it is very important to develop optimal design technology of grid connected PV system.