• Title/Summary/Keyword: Congener

Search Result 120, Processing Time 0.027 seconds

Concentration of Polybrominated Diphenyl Ethers and Their Composition in Octopus minor Collected from Seosan Intertidal Zone (낙지(Octopus minor)에서의 브롬계화합물(Polybrominated diphenyl ethers, PBDEs)의 잔류농도와 조성특성)

  • Lee, Hyo-Jin;Kim, Gi-Beum;Stapleton, Heather
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.1
    • /
    • pp.68-74
    • /
    • 2010
  • Octopus(Octopus minor), benthic cephalopod, were collected from intertidal zone in Seosan, Choongnam and analyzed for polybrominted diphenyl ethers(PBDEs). PBDEs concentrations ranged from 29 to 109 ng/g lipid wt(mean; 54 ng/g) in mantle and from 12 to 89 ng/g lipid wt(mean; 48 ng/g) in internal organ. PBDEs concentrations in octopus internal organ were lower about two times than that in common squid collected in Yellow Sea, indicating Seosan is relatively less contaminated with PBDEs. Major congener was BDE 206, occupying 72% and 49% of total PBDE concentration in mantle and in internal organ, respectively, which is very different from PBDE composition in common squid with major congeners of BDE 47 and 99. From PBDE composition, octopus seemed to concentrate higher brominated BDE rather than lower brominated BDE. This PBDE composition in octopus may be affected by sediment with extremely high contribution of deca-BDE to total PBDE concentration.

Congener Specific Characteristics of PCBs and PCDD/Fs and Risk Assesment for Human Milk of Korea (국내 모유에서의 PCBs 및 PCDD/Fs 분포 특성과 위해성 평가)

  • Yang, Yoon-Hee;Chang, Yoon-Seok;Kim, Byung-Hoon;Yang, Ji-Yoen;Shin, Dong-Chun
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.520-533
    • /
    • 2000
  • We analyzed the PCDD/Fs and PCBs in human milk samples from a city and an industrial region by HRGC/HRMS. The average concentrations of PCDD/Fs and PCBs in human milk were 15.13 TEQ pg/g fat and 5.64 TEQ pg/g fat respectively. We discovered two kinds of homologue distributions. We compared congeners of each distributions with those of the commercial PCBs products. The daily intake of infant was predicted to be 60 TEQpg/kg/day according to the mean concentration of PCDD/Fs based on primipara. This value is much higher than the estimated range for background exposure to adult in the USA (1-3 TEQ pg/g fat).

  • PDF

Separation properties of 209 PCB congeners on capillary columns and identification of PCBs congeners in aroclor standards for source identification (오염원 해석을 위한 폴리염화비페닐류(PCBs) 209 이성체의 컬럼별 분리 특성과 Aroclor 표준품의 이성체 확인)

  • Kim, Kyoung-Soo;Kim, Kyeo-Keun;Kim, Jong-Guk
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.352-364
    • /
    • 2006
  • This study was performed to search for useful separation properties and elution orders of three GC columns (DB-1, DB-5MS, SPB-Octyl) for 209 PCBs congeners using M-1668A-0.01X-SET of the AccuStandard Inc.. In addition, to confirm the quantitative peak in peak pattern method, the IUPAC Nos. of PCBs congener peaks were identified with 4 Aroclor standards (Aroclor-1242, 1248, 1254 and 1260). The separation property of dioxin-like PCBs congeners by four columns (DB-1, DB-5MS, SP-2331 and SPB-Octyl) was excellent in SP-2331. DB-1 and SPB-Octyl columns are necessary to use with a column of other types.

The analysis of the urushiol congeners from the extracts of lacquer trees (옻나무 추출물 중 우루시올 동종체의 함량비 분석)

  • Cho, Yumi;Jung, Yu-Kyung;Kim, Jinsan;Lee, Joonbae;Paeng, Ki-Jung
    • Analytical Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.65-74
    • /
    • 2009
  • Active components of lacquer tree referred to as urushiol congeners, which are catechol derivatives with various alkyl or alkenyl substituents. The olefin side chains typically have one, two or three double bonds. In this study, the each congener's ratio analysis of extracts from korean lacquer tree are compared to the one from other asian lacquer tree. Extraction was performed using liquid-liquid extraction (LLE) method with soxhlet system from tree's bark and sap. Extracts were analyzed by reverse phase liquid chromatography and on-line electro spray ionization mass spectrometry (LC-MS/MS).

Determination of byproducts after treatment in PCBs-containing transformer oils (PCBs 함유 절연유의 처리 후 부산물 배출특성 연구)

  • Shin, Sun Kyoung;Park, Jin Soo;Kang, Young Yeul;Hwang, Seung Ryul;Kim, Young Sik
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.201-211
    • /
    • 2008
  • The treatment efficiency of PCBs containing wastes has been investigated. The samples treated by electron beam and de-chlorination method were analyzed to verify the byproducts before treatment and after treatment. In the treated samples by electron beam irradiation, PCBs were not detected by comparing the peak matching using the Korean official waste test method. On the other hand, PCBs congeners were detected by analyzing individual isotope method using HRGC/HRMS. Most of PCB congeners in waste were decomposed to 3-chlorobiphenyls, lower chlorinated congener produced during the treatment of electron beam. In the chemical dechlorination treatment, it was found that the concentrations of PCBs in treated samples were lower than those of regulation criteria in Waste & POPs management law and the after treatment concentration were satisfied to the regulation criteria. Also, dioxins were not observed after the physio-chemical treatment processes of PCBs containing wastes.

Environmental Pollutants in Streams of Andong District and Insect Immune Biomarker (안동지역 하천의 환경오염물질과 곤충면역 생체지표 분석)

  • Ryoo Keon Sang;Ko Seong-Oon;Cho Sunghwan;Lee Hwasung;Kim Yonggyun
    • Korean journal of applied entomology
    • /
    • v.44 no.2
    • /
    • pp.97-108
    • /
    • 2005
  • Samples of water, soil, and sediment were taken from 10 streams near Andong, Korea in May 2004. To assess the degree of environmental pollution of each stream, chemical pollutants such as total notrogen (T-N), total phosphorus (T-P), chemical oxygen demand (COD), heavy metals, organophosphorus pesticides, organochlorine pesticides, and dioxin-like PCB congeners were analyzed by standard process tests or U.S. EPA methods. In addition, biomarkers originated from insect immune systems of beet armyworm, Spodoptera exigua, were used to analysis of the environmental samples. Except Waya-chun stream showing T-N content of 9.12 mg/L, most streams were contaminated with relatively low levels of overall pollutants in terms of T-N, T-P, and COD, compared to their acceptable environmental levels designated by the Ministry of Environment. Contents of Pb and Cd in samples of each stream were much lower than environmentally permissible levels. However, several times higherconcentrations of Pb and Cd were found in locations at Mi-chun, Kilan-chun, and Hyunha-chun streams, in comparison with other streams. Diazinon, parathion, and phenthoate compounds among organophosphorus pesticides were detected as concentrations of 0.19, 0.40, and $1.13\;{\mu}g/g$, respectively, from soil sample collected in the vicinity of Mi-chun stream. On the other hand, 16 organochlorine pesticides and 12 dioxin-like PCB congeners, known as endocrine disrupting chemicals, selected in this study were not found above the limit of detection. Biomarker analyses using insect immune responses indicated that Waya-chun stream was suspected as exposure to environmental pollutants. Limitation and compensation of both environmental analysis techniques are discussed.

Analysis of all PCB Congeners in Air Samples by HRGC/HRMS (대기 시료 중 PCBs 전 이성체 분석에 관한 연구)

  • Kim, Kyoung-Soo;Song, Byung-Joo;Kim, Jong-Guk
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.309-319
    • /
    • 2003
  • This study was performed to describe analysis method of 209 PCB congeners in ambient air samples. The samples were collected by high volume air sampler in Chonju city. Extracted samples were cleaned by silicagel cleanup modified with sulfuric acid and activated carbon cleanup processing. The cleaned samples were analyzed by high resolution gas chromatography and high resolution mass spectrometry (HRGC/HRMS) with DB-5 column (60 m, 0.25 mm i.d., 0.25 m film thickness) to analyze the 209 kinds of PCB congeners. PCBs levels of air samples were detected to the range between 0.003 and $0.163pg-TEQ/m^3$. The PCBs congener of 162 kinds were detected in samples analysed using DB-5 column and 37 kinds peaks were overlapped with congeners more than one. It is difficult to isolate PCB 118/106 and PCB 105/127 in coplanar PCB, so it is likely to overestimate the concentration.. The distribution of coplanar-PCB congeners in origin source samples (Kanechlor and exhaust gas from incinerator) was compared with that in air samples, and PCB 81, PCB 77, PCB 126, and PCB 169 were higher in incinerator samples.

The Community Structure of Plant at the Edge of the Oncheon River in Busan (부산광역시 온천변 식물상의 군집구조에 관한 연구)

  • Moon, Sung-Gi;Huh, Man-Kyu
    • Journal of Life Science
    • /
    • v.18 no.7
    • /
    • pp.924-930
    • /
    • 2008
  • Community structure refers to the number of species in a community and the pattern of distribution of individuals among those species. The purpose of this paper was to describe a statistical analysis for detecting a ecological biodiversity which is valid even though the assumption at the different sampling points is not violated spatial randomness of species. Counts and cover were determined from 10 ($20\;m{\times}20\;m$) plots in five sites of the Oncheon River which is located in Busan, Korea. Total 95 taxa (85 species, 9 varieties, and one form) were identified and measured in edge sides of this river. These were a total of present in the five sites. Overall across the fragments, mean number of species per plot differed significantly among the five sites (F=7.75, p<0.01). Shannon-Wiener functions differed significantly among plots (F=4.12, p<0.05), with the St. 1 having significantly higher value (2.380) than the others (2.206 for St. 2, 2.116 for St. 3, 2.069 for St. 4, and 0.637 for St. 5). The richness indices, R1 decreased from the upper stream of the Oncheon River to the lower stream. We used a novel way of representing community structure to show that abundance within closely related pairs of co-occurring species in the Oncheon River. The differences between the distributions for of congeners and pairs of non-congeners showed at the largest difference of the cumulative fractions of the data sets (x=0.85).

Concentration and Gas-particle Partition of PCDDs/Fs and dl-PCBs in the Ambient Air of Ansan Area (안산지역 대기 중 다이옥신 및 dl-PCBs의 오염특성 조사)

  • Heo, Jong-Won;Kim, Dong-Gi;Song, Il-Seok;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.517-532
    • /
    • 2010
  • After establishment of Banwol industrial complex in 1987, Ansan city becomes the largest industrial sector development in Gyeonggi-do, Korea. As the population and industrial activity grow over this region, toxic air pollutants, particularly POPs (Persistent Organic Pollutants) from various emission sources have been major public concerns. Air samples for POPs monitoring were collected at the industrial sites ($A_2$), residential sites ($B_1$, $B_2$), commercial site (C), and rural/remote site (D) of the area of Ansan during 2008 with a prolonged industrial sampling site $A_1$ from 2001 to 2008. All samples were analysed for 2,3,7,8 substituted-polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs) and dioxin like polychlorinatd diphenyls (dl-PCBs). In site $A_1$, a steady decline of their concentrations from 2003 to 2008 was observed due to the reinforced emission guideline from waste incinerators. The average concentration of the PCDD/Fs and dl-PCBs ranged between 0.118 pg-TEQ/$m^3$ (rural/remote site D) and 0.532 pg-TEQ/$m^3$ (industrial area $A_2$). These level were generally consistent with previous studies in Gyeonggi-do, while higher than other places. Most of PCDD/Fs congener were partitioned into particle phase, whereas dl-PCBs were partitioned into gas phase. The logarithm of gas-particle partition coefficient $K_P$ of dl-PCBs and PCDD/Fs were well correlated with sub-cooled liquid vapor pressure $P_L$. The slope $m_T$ of log $K_P$ versus log $P_L$ for PCDD/Fs (-1.22) and dl-PCBs (-1.02) in industrial area ($A_2$) were high compared to other residential/commercial area. It suggests that this area was likely influenced by the direct emission source of PCDD/Fs and dl-PCBs. To simulate the partition of PCDD/Fs and dl-PCBs between gas and particle phase, Junge-Pankow model ($P_L$-base) and $K_{oa}$ model were applied. It was found that J-P model was more suitable than the $K_{oa}$ model in this study.

Distribution Chara Cteristics of Polychlorinated Biphenyls in the Southern Korea (동해남부 대마난류계에서의 염소화 Biphenyls의 분포특성)

  • LEE Dong-In;Ok Gon;YANG Han-Soeb;CHANG Yoon-Seok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.4
    • /
    • pp.679-686
    • /
    • 1997
  • In order to investigate the distribution characteristics of polychlorinated Biphenyls (PCBs) at the southern of Korean East Sea, vertical measurements of temperature, salinity, DO and PCBs were performed by each depth of 5 stations during August - October 1996. Thermocline and salinocline were generally existed at depth of 30 m and water mass current of midwater in the southern of Korean East Sea was distributed below 30 m depth. The distribution of surface water mass in this area was extended to Tsusima area from the southern offshore of the Korean last Sea. In August 1996, concentration range of PCBs had $0.22\~0.36\;ng/\ell$ at surface layer and their concentrations at near Tsusima offshore were relatively decreased. Total mean concentration of PCBs was $0.29\;ng/\ell$ in the sea surface and $0.31\;ng/\ell$ in the middle layer. PCBs seemed to correlate well with suspended particles. And vortical and horizontal distribution of their concentrations showed comparatively uniform pattern. Relatively high compositional ratio of Di- and Tri-PCBs could be found at the sea surface, while compositional ratio of Penta-PCBs dominates over other congener at deep layer.

  • PDF