• 제목/요약/키워드: Conformity index

검색결과 134건 처리시간 0.026초

Comparison of Linear Accelerator and Helical Tomotherapy Plans for Glioblastoma Multiforme Patients

  • Koca, Timur;Basaran, Hamit;Sezen, Duygu;Karaca, Sibel;Ors, Yasemin;Arslan, Deniz;Aydin, Aysen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권18호
    • /
    • pp.7811-7816
    • /
    • 2014
  • Background: Despite advances in radiotherapy, overall survival of glioblastoma multiforme (GBM) patients is still poor. Moreover dosimetrical analyses with these newer treatment methods are insufficient. The current study is aimed to compare intensity modulated radiation therapy (IMRT) linear accelerator (linac) and helical tomotherapy (HT) treatment plans for patients with prognostic aggressive brain tumors. Material and Methods: A total of 20 GBM patient plans were prospectively evaluated in both linac and HT planning systems. Plans are compared with respect to homogenity index, conformity index and organs at risk (OAR) sparing effects of the treatments. Results: Both treatment plans provided good results that can be applied to GBM patients but it was concluded that if the critical organs with relatively lower dose constraints are closer to the target region, HT for radiotherapeutical application could be preferred. Conclusion: Tomotherapy plans were superior to linear accelerator plans from the aspect of OAR sparing with slightly broader low dose ranges over the healthy tissues. In case a clinic has both of these IMRT systems, employment of HT is recommended based on the observed results and future re-irradiation strategies must be considered.

Dosimetric Evaluation of an Automatically Converted Radiation Therapy Plan between Radixact Machines

  • Lee, Mi Young;Kang, Dae Gyu;Kim, Jin Sung
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.153-162
    • /
    • 2020
  • Purpose: We aim to evaluate the accuracy and effectiveness of an automatically converted radiation therapy plan between Radixact machines by comparing the original plan with the transferred plan. Methods: The study involved a total of 20 patients for each randomly selected treatment site who received radiation treatment with Radixact. We set up the cheese phantom (Gammex RMI, Middleton, WI, USA) with an Exradin A1SL ion chamber (Standard Imaging, Madison, WI, USA) and GAFCHROMIC EBT3 film (International Specialty Products, Wayne, NJ, USA) inserted. We used three methods to evaluate an automatically converted radiation therapy plan using the features of the Plan transfer. First, we evaluated and compared Planning target volume (PTV) coverage (homogeneity index, HI; conformity index, CI) and organs at risk (OAR) dose statistics. Second, we compared the absolute dose using an ion chamber. Lastly, we analyzed gamma passing rates using film. Results: Our results showed that the difference in PTV coverage was 1.72% in HI and 0.17% in CI, and majority of the difference in OAR was within 1% across all sites. The difference (%) in absolute dose values was averaging 0.74%. In addition, the gamma passing rate was 99.64% for 3%/3 mm and 97.08% for 2%/2 mm. Conclusions: The Plan transfer function can be reliably used in appropriate situations.

생존기간을 고려한 생애소득대체율의 추정 (The estimation of lifetime income replacement rates)

  • 신승희;손현섭;이항석
    • Journal of the Korean Data and Information Science Society
    • /
    • 제25권6호
    • /
    • pp.1315-1331
    • /
    • 2014
  • 소득대체율은 은퇴 전 소득 대비 은퇴 후 소득이 어느 정도 인지를 나타내는 지표로써, 사회보장제도의 급여수준이나 노후대비소득의 적정성을 논할 때 매우 유용하게 사용된다. 기존 연구들은 소득대체율 개념을 통해 은퇴시점이나 특정 은퇴기간의 은퇴소득을 진단하고 있다. 본 연구에서는 생애에 초점을 두고 생존기간에 따라 소득대체율이 어떻게 변화하는지 살펴보았으며, 생존기간에 따른 소득대체율을 하나의 지표 값으로 나타내어 분석하였다. 이를 생애소득대체율로 명명하였으며, 분석결과 3대 연금에 모두 20년 가입 시 남자의 생애소득대체율은 38.3%, 여자의 생애소득대체율은 41.1%로 예상된다.

화학산업에서의 안전성능지수 개발에 관한 연구 (A Study on the Development of Safety Performance Index in Chemical Industry)

  • 강미진;이영근;권혁면
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.57-61
    • /
    • 2008
  • In order to maintain the continual safety management in a company, it needs to evaluate and monitor its implementation of safety management. Because the number of major-accidents is not an effective method of indicating company's safety performance, various efforts to develop more reasonable indicators have been made in world wide. After Korean government has legally required the PSM report, PSM compliance audit has been developed and made by the authorities concerned since 2005. However, this audit consists of complicate procedures difficult to utilize as companies' own audit program and corresponds to only a conformity check that confirms whether the PSM be operated and maintained properly. So a new index by which to measure easily the level of safety performance and self-monitor the implementation of safety management is needed. We have studied a new method that may quantitatively evaluate the performance of safety management by investigating application cases in foreign countries and doing the domestic survey of lots of companies subject to PSM regulation in Korea. This study proposes three of safety performance indices(SPI) together with the several prerequisite preconditions and the timing for application of each index. Although the first draft of SPI needs further legal support, it might help to evaluate every company's safety level. The second draft of SPI is a voluntarily evaluating method based on web-site online program. The last draft of SPI consists of a series of simple questions about 12 elements of PSM. Also each of 3 indices has differences in evaluation methodology and application area and, therefore, they may be used concurrently.

토모다이렉트를 이용한 3차원 전뇌 방사선치료에서 두상 각도에 따른 치료계획평가: 팬톰 실험 (Evaluation of Treatment Planning for Head Tilting in WBRT 3D-CRT by TomoDirect mode: a Phantom Study)

  • 김대건;김상현
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.857-862
    • /
    • 2022
  • 본 연구의 목적은 토모다이렉트를 이용한 토모테라피 방사선치료에서 두상 각도(head tilting)에 따라 3차원 입체조형 전뇌 방사선치료 계획을 평가하고 자 하였다. 총 다섯 가지 두상 각도(-20°, -10°, 0°, +10°, +20°)를 비교 평가하였다. 두상 각도에 따라 표적에 대한 선량균질지수(homogeneity index, HI)와 처방선량지수(conformity index, CI)를 계산하였고, 정상 장기인 수정체, 안구, 귀밑샘에 대한 최대선량과 평균 선량을 구하였다. 선량균질지수와 처방선량지수는 두상 각도가 +10°와 +20°에서 수치 1에 가까웠다. 두상 각도 +10°에서 수정체와 안구의 선량은 기준 두상각도(0°)에 비해 각각 약 74%와 30% 감소하였다. 턱을 올린 상태의 +10°의 두상 각도는 표적에 대한 선량균일지수와 처방선량지수가 적합하며 렌즈와 안구의 선량을 줄일 수 있는 각도로써 권장한다.

Predicting Net Income for Cultivation Plan Consultation

  • Lee, Soong-Hee;Yoe, Hyun
    • Journal of information and communication convergence engineering
    • /
    • 제18권3호
    • /
    • pp.167-175
    • /
    • 2020
  • The net income per unit area from crop production could be the most critical consideration for agricultural producers during cultivation planning. This paper proposes a scheme for predicting the net income per unit area based on machine learning and related calculations. This scheme predicts rice production and operation costs by applying climate and price index data. The rice price is also predicted by applying rice production and operation cost data. Finally, these predicted results are employed to calculate the predicted net income, which is compared with the actual net income. Consequently, the proposed scheme shows a meaningful degree of conformity, which indicates the potential of machine learning for predicting various aspects of agricultural production.

유방암 접선조사에서 PBC 알고리즘과 AAA에 따른 Field-in-Field Intensity Modulated Radiation Therapy와 Conventional Radiation Therapy 전산화 치료계획에 대한 고찰 (Study on Computerized Treatment Plan of Field-in-Field Intensity Modulated Radiation Therapy and Conventional Radiation Therapy according to PBC Algorithm and AAA on Breast Cancer Tangential Beam)

  • 염미숙;배성수;김대섭;백금문
    • 대한방사선치료학회지
    • /
    • 제24권1호
    • /
    • pp.11-14
    • /
    • 2012
  • 목 적: Anisotropic Analytical Algorithm (AAA)는 Pencil Beam Convolution (PBC) 알고리즘에 비하여 2차선과 조직 불 균질에 대한 영향에 보다 더 정확한 선량계산을 제공한다. 본 연구는 유방암 접선조사 치료계획에서 PBC 알고리즘과 AAA의 선량계산 알고리즘에 따른 선량분포의 차이를 분석하고자 한다. 대상 및 방법: 선형가속기(CL-6EX, VARIAN, USA)의 6 MV 에너지를 이용한 유방암 환자 10명을 대상으로 Eclipse treatment planning system (Version 8.9, VARIAN, USA)을 사용하여 전산화 치료계획을 수립하였다. Conventional Radiation Therapy plan(Conventional plan)과 Field-in-Field Intensity Modulated Radiation Therapy plan (FiF plan)을 PBC 알고리즘을 이용하여 치료계획을 수립한 후 Monitor Unit (MU)를 고정시키고 AAA로 변경하여 선량계산하고, Dose Volume Histogram (DVH)을 이용하여 치료계획을 비교 분석하였다. 결 과: 첫 번째, Conventional plan의 PBC 알고리즘과 AAA에 따른 차이를 평가한 결과 치료용적에 대한 평균 Conformity Index (CI) 값의 차이는 PBC 알고리즘에서 0.295 높게 평가 되었다. 동측 폐에 대한 선량을 평가한 결과 $V_{47Gy}$$V_{45Gy}$는 PBC알고리즘에서 각각 5.83%, 4.04% 높게 평가되었고, Mean dose, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$는 AAA에서 각각 0.6%, 0.29%, 6.35%, 10.23%높게 평가되었다. 두 번째, FiF plan의 경우 치료용적에 대한 평균 CI 값의 차이는 PBC 알고리즘에서 0.165 높게 평가 되었고, 동측 폐에 대한 선량은 $V_{47Gy}$, $V_{45Gy}$, Mean dose는 PBC 알고리즘에서 각각 6.17%, 3.80%, 0.15% 높게 평가되었고, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$는 AAA에서 각각 0.14%, 4.07%, 4.35% 높게 평가되었다. 결 론: 유방암 접선조사에서 AAA로 계산했을 때, PBC 알고리즘에 비해 치료용적에 대한 Conformity가 Conventional plan, FiF plan 각각 0.295, 0.165 낮게 평가 되며, 동측 폐의 고 선량 영역의 선량은 적게 나타나며, 저 선량 영역의 선량은 많게 나타므로 폐에 대한 선량을 평가하는 데 선량계산 알고리즘에 따른 특징을 고려해야 할 것으로 사료된다.

  • PDF

Evaluation of the hybrid-dynamic conformal arc therapy technique for radiotherapy of lung cancer

  • Kim, Sung Joon;Lee, Jeong Won;Kang, Min Kyu;Kim, Jae-Chul;Lee, Jeong Eun;Park, Shin-Hyung;Kim, Mi Young;Lee, Seoung-Jun;Moon, Soo-Ho;Ko, Byoung-Soo
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.241-247
    • /
    • 2018
  • Purpose: A hybrid-dynamic conformal arc therapy (HDCAT) technique consisting of a single half-rotated dynamic conformal arc beam and static field-in-field beams in two directions was designed and evaluated in terms of dosimetric benefits for radiotherapy of lung cancer. Materials and Methods: This planning study was performed in 20 lung cancer cases treated with the VERO system (BrainLAB AG, Feldkirchen, Germany). Dosimetric parameters of HDCAT plans were compared with those of three-dimensional conformal radiotherapy (3D-CRT) plans in terms of target volume coverage, dose conformity, and sparing of organs at risk. Results: HDCAT showed better dose conformity compared with 3D-CRT (conformity index: 0.74 ± 0.06 vs. 0.62 ± 0.06, p < 0.001). HDCAT significantly reduced the lung volume receiving more than 20 Gy (V20: 21.4% ± 8.2% vs. 24.5% ± 8.8%, p < 0.001; V30: 14.2% ± 6.1% vs. 15.1% ± 6.4%, p = 0.02; V40: 8.8% ± 3.9% vs. 10.3% ± 4.5%, p < 0.001; and V50: 5.7% ± 2.7% vs. 7.1% ± 3.2%, p < 0.001), V40 and V50 of the heart (V40: 5.2 ± 3.9 Gy vs. 7.6 ± 5.5 Gy, p < 0.001; V50: 1.8 ± 1.6 Gy vs. 3.1 ± 2.8 Gy, p = 0.001), and the maximum spinal cord dose (34.8 ± 9.4 Gy vs. 42.5 ± 7.8 Gy, p < 0.001) compared with 3D-CRT. Conclusions: HDCAT could achieve highly conformal target coverage and reduce the doses to critical organs such as the lung, heart, and spinal cord compared to 3D-CRT for the treatment of lung cancer patients.

Metalaxyl-M 및 dinotefuran 입제의 쑥갓 중 잔류 특성 및 위해성 평가 (Residual Characteristics and Risk Assessments of Metalaxyl-M and Dinotefuran in Crown Daisy)

  • 송민호;유지우;김진찬;이광헌;고락도;금영수;이지호
    • 한국환경농학회지
    • /
    • 제41권2호
    • /
    • pp.108-114
    • /
    • 2022
  • BACKGROUND: This study was performed to determine residual characteristics of soil-treated metalaxyl-M and dinotefuran in crown daisy and to evaluate the risks from intake of the residual pesticides in the crop. METHODS AND RESULTS: The pesticide granules were treated in soil on two levels, and the plants samples were collected 51 days after seeding. The analytes were extracted and partitioned using the QuEChERS extraction packet (MgSO4 4 g, NaCl 1 g). The quantitative methods for metalaxyl-M and dinotefuran were validated in linearity, accuracy, and precision. Risk assessments of the pesticides were performed using Korea national nutrition statistics 2019. CONCLUSION(S): The residual concentrations of metalaxyl-M in crown daisy were 0.09-0.10 mg/kg (for the treatment at 6 kg/10 a) and 0.17-0.19 mg/kg (12 kg/10 a), respectively. The residual concentrations of dinotefuran in the crop were 0.53-0.75 mg/kg (3 kg/10 a) and 1.17-1.26 mg/kg (6 kg/10 a). The amounts of pesticides were less than MRL (Maximum Residue Limits) according to the Korean MFDS (Ministry of Food and Drug Safety). The HI (Hazard Index) of metalaxyl-M and dinotefuran for consumers was 0.0075% and 0.2250%, respectively. For females in the age between 50-64, the major consumer group, the HIs of the pesticides were <3%. Considering the consumption of crown daisy, they are not considered to be of toxicological concern.

동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석 (Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories)

  • 강민영;이보람;김유현;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권1호
    • /
    • pp.51-58
    • /
    • 2011
  • 본 연구의 목적은 회전조사 시 표적종양의 위치변위와 갠트리의 조사반경에 의한 치료깊이 변화에 따른 모의치료계획 결과와 선량전달 결과상의 오차를 분석하고자 하였다. 깊이 변위가 가장 이상적인 경우, 즉 팬텀의 중심에 표적이 위치한 경우와 한쪽으로 2.5 cm, 5 cm씩 치우친 경우로 나누어 모의실험하였다. 표적의 위치 변화에 따른 모의치료계획을 실시하기 위하여 IMRT Body 팬톰(I'mRT Phantom, Wellhofer Dosimetry, Germany)를 이용하여 전산화단층촬영장치(Computed Tomography, Light speed 16, GE, USA)로 데이터를 획득하였다. 획득된 영상을 이용하여 치료계획장치(Treatment Planning System, Eclipse, ver. 6.5, VMS, Palo Alto, USA)를 이용하여 정중앙, 2.5 cm, 5 cm에 가상의 치료표적을 만들어 모의치료계획을 수립하였다. 선형가속기(CL21EX, VMS, Palo Alto, USA)의 6 MV 광자선과 최근 개발된 Gafchromic 필름(EBT2, ISP, Wayne, USA)을 이용하여 선량분포를 측정하였고, 선량분석프로그램(OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany)을 이용하여 모의치료계획 데이터와 측정 데이터를 정량적으로 분석하였다. 분석프로그램으로 횡축방향 선량분포 프로파일(Cross-plane profile)과 선량분포를 정량적으로 분석하기 위하여 감마인덱스(DD: 3%, DTA: 2 mm) 히스토그람을 이용하였다. 표적과 표적주변의 선량분포는 Conformity index(CI), Homogeneity index(HI)를 이용하여 정량적으로 분석하였다. 치료표적 전체체적에 대한 100% 선량분포에 포함되는 체적을 비교하여 분석하였다. 표적의 위치가 5 cm 에 있는 경우 다문동적회전조사(Multiple Conformal Arc Therapy, MCAT)는 23.8%, 단일동적회전조사(Single Conformal Arc Therapy, SCAT)는 35.6%, 고정조사는 37%였고, 표적이 2.5 cm에 있는 경우 MCAT 61%, SCAT 21.5%, 고정조사 14.2%로 분석되었다. 표적의 위치가 중앙에 있는 경우 MCAT 70.5%, SCAT 14.1%, 고정조사 36.3%로 나타났다. 표적의 위치가 5 cm 치우쳐 있는 경우를 제외하고 MCAT의 100% 선량분포에 포함되는 체적이 가장 크게 나타났다. 감마인덱스 히스토그램 분석결과, SCAT의 경우 37.1, 27.3, 29.2로 MCAT의 경우 9.2, 8.4, 10.3에 비해 최소 2.8배, 최대 4배 오차가 크게 나타났다. 결론적으로, 동적조형회전조사 시 표적종양의 위치변이와 조사반경의 변화에 따라 선량전달오류의 가능성을 알 수 있었으며 치료표적의 위치가 정중앙이 아닐 경우, 깊이와 회전반경을 최적화함으로써 정확한 선량 전달을 할 수 있다고 생각한다.