• Title/Summary/Keyword: Conformity

Search Result 1,217, Processing Time 0.026 seconds

Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study (한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구)

  • Yoon, Yong-Cheol;Oh, Jong-Keon;Kim, Young-Woo;Kim, Hak Jun;Moon, Hong Joo;Kim, Nam-Ryeol
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

A Study on the difference of school life adaptation of adolescent according to the clothing behavior conformity and the attitude toward the name-brand: In case of Gwangju metropolitan area (청소년의 의복동조 준거특성 및 유명브랜드에 대한 태도에 따른 학교생활적응의 차이연구: 광주지역을 중심으로)

  • Sin, Sun Mi;Wee, Eun Hah
    • Journal of Korean Home Economics Education Association
    • /
    • v.26 no.2
    • /
    • pp.15-30
    • /
    • 2014
  • The purpose of this study is to provide basic information on clothing preference to help teachers suggest clothes that help students adapt better to school life, and to get basic data specific to Home Economics curricula and how teenagers' attitude toward clothes correlate with their conformity to school as a whole. The survey of 587 students was conducted between December 17-24, 2012 in Gwangju. The data was analyzed using the SPSS 18.0 for window program: frequency, means, factor analysis, cluster analysis, Chronbach's ${\alpha}$, t-test, and ANOVA. There were significant differences in the many adolescents's adapted to school life based on the clothing behavior conformity and the attitude toward the name-brand. The results showed that, if it is not extreme, adolescents had the more the clothing behavior conformity on peer & mass media than less, they did well adapt on school life. And the group of more preference for the name-brand clothing result in low school discipline adaptation but high peer and teacher relationship. In adaptation of learning, they were not different significantly based on attitudes toward the name brand.

  • PDF

Performance evaluation of Surface Temperature Reduction by using Green infrastructure Surface Temperature Measurement for Urban Heat Island Mitigation (도시열섬완화를 위한 그린인프라시설의 표면온도 저감 성능평가)

  • Ko, Jong Hwan;Bae, Woo Bin;Park, Dae Geun;Jung, Won Kyong;Park, Yun mi;Kim, Yong Gil;Kim, Sang Rae
    • Ecology and Resilient Infrastructure
    • /
    • v.5 no.4
    • /
    • pp.257-263
    • /
    • 2018
  • This study is to develop a GSTM (Green infrastructure Surface Temperature Measurment) equipment for reducing the surface temperature of GI by using LID Method. The tests were conducted including GI products such as Greening block, Pervious Block, Soil Block and so on. The GSTM equipment developed by considering the literature surveys are characterized as follows. The non-contact infrared temperature sensor was used to measure the surface temperature, and it was improved to measure the overall average temperature including the center and the corner temperature of the specimen. The developed GSTM equipment was used to compare performance of asphalt and GI products. As a result, the Greening Block show a high difference of $18.4^{\circ}C$ and it contributes to the decrease of surface temperature.

Characteristics of Compressive Strength Development of High Strength Cement Composites Depending on Its Mix Design (고강도 시멘트 복합체의 배합조건에 따른 압축강도 발현 특성)

  • Jeong, Yeon-Ung;Oh, Sung-Woo;Cho, Young-Keun;Jung, Sang-Hwa;Kim, Joo-Hyung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.585-593
    • /
    • 2021
  • This study investigates the compressive strength of high-strength cement composites with 64 mixture designs and 2 curing conditions. The cement composites were designed with varying water-to-binder ratios, silica fume content to cement, and binder content per unit volume of cement composite to explore compressive strength development depending on its mix design. An increase in the water-to-binder ratio decreased the compressive strength of the composites, having consistency with the trend in normal concrete. The compressive strength increased with ages at an ambient curing temperature, but it was not identified at high-temperature curing. The compressive strength development was negligible in case that silica fume content to OPC is 15%~25%, but a decrease in the con ten t below 15% reduced compressive stren gth. It was more obvious in the specimen of low water-to-binder ratio. The specimen with 840kg/m3 of binder content per unit volume had the highest compressive strength in this study, and the decrease in binder content reduced the compressive strength of high strength cement composites in low silica fume content.

Comparison of Treatment Plans with Multileaf Collimators of different Leaf Width (Leaf width가 다른 다엽 콜리메터에 의한 치료계획 비교)

  • Kim Joo Young;Park Sung Yong;Lee Doo Hyun;Lee Seok Ho;Kim Tae Hyun;Cho Kwan Ho
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.173-178
    • /
    • 2004
  • Purpose: To compare desimetrically intensity-modulated radiotherapy treatment plans with commercially available multileaf collimators (MLCs) of different leaf width for intracranial lesions. Materials and Methods: Twelve patients with intracranial lesions were treated with BrainLAB's micro-MLCs (mMLCs) and performed with the BrainSCAN ver. 5.2 planning software. They were replanned using the Varian 120 and 80 MLCs. These collimators have minimum leaf width of 3 mm, 5 mm and 10 mm at isocenter, respectively. PTV was $3.3~339.2\textrm{cm}^3$ and the number of beams was 3~7. These three plans were compared with respect to the uniformity and the conformity indices, doses to critical organ and normal tissue. Results: For the uniformity index of the planning target volume (PTV), there were no statistically significant differences between mMLCs and 120 MLCs (p=0.057) and between 120 MLCs and 80 MLCs (p=0.388). However, there was a difference between mMLCs and 80 MLCs (p<0.001). Maximum target dose to the PTV showed no dependency with respect to the leaf width. On the contrary, there were statistically significant differences in the conformity indices between mMLCs and 120 MLCs (p=0.003), between mMLCs and 80 MLCs (p=0.003) and between 120 MLCs and 80 MLCs (p=0.003). The volume of brainstem irradiated to $\geq$70% dose and to $\geq$50% dose was increased as the leaf width of MLCs increased. In particular, the volume of normal tissue irradiated is obviously changed for different leaf width. Volumetric increments for MLCs with leaf widths of 5 mm and 10 mm were 6.3% and 23.2% to the normal tissue irradiated to $\geq$50% dose, and 8.7% and 32.7% to the normal tissue irradiated to $\geq$70% dose, respectively, compared to the volume for MLCs with leaf width of 3 mm. Conclusions: The uniformity index and maximum target dose to the PTV showed no dependency with respect to leaf width of MLCs. However, the conformity index was improved as the leaf width decreased. For the sparing of normal brain tissue, treatment plans with MLCs of 3 mm leaf width is more effective, compared to ones with MLCs of 5 mm and 10 mm leaf widths.

  • PDF

THE JAPANSE STATUS OF LABORATORY ACCREDITATION BASED ON FASTENER QUALITY ACT.

  • Aoyagi Tutomu;Imai O Yoshio
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.339-344
    • /
    • 1998
  • Since 1997, JAB (The Japan Accreditation Board for Conformity Assessment) had started the activity of accreditation for the laboratory based on U.S. PL101-592: the Fastener Quality Act that was signed by President Bush on 1990. The number of accredit laboratories are 69 in Japan, 21 in Taiwan, 2 in Korea and 189 in U. S. A, as of 09/10/1998. The JAB accreditation encompasses the requirements of the ISO/IEC Guide 25, and the relevant requirements of ISO 9002. The purpose of ISO/IEC Guide 25, also had been harmonized as JIS Z 9325 'General requirements for the competence of calibration and testing laboratories 'mainly facilitates and promotes acceptance of calibration and test results between countries to avoid barriers to trade through as 'one stop testing'. The features and differences between Guide 25 and ISO 9000 will be clarify in this report.

  • PDF