• Title/Summary/Keyword: Confocal laser scanning microscopy(CLSM)

Search Result 77, Processing Time 0.019 seconds

Application of Autofluorescence for Confocal Microscopy to Aid in Archaeoparasitological Analyses

  • Morrow, Johnica Jo;Elowsky, Christian
    • Parasites, Hosts and Diseases
    • /
    • v.57 no.6
    • /
    • pp.581-585
    • /
    • 2019
  • Confocal laser scanning microscopy (CLSM) was used to examine archaeoparasitological specimens from coprolites associated with La Cueva de los Muertos Chiquitos (CMC) located near present-day Durango, Mexico. The eggs for 4 different types of parasites recovered from CMC coprolites were imaged using CLSM to assist with identification efforts. While some of the parasite eggs recovered from CMC coprolites were readily identified using standard light microscopy (LM), CLSM provided useful data for more challenging identifications by highlighting subtle morphological features and enhancing visualization of parasite egg anatomy. While other advanced microscopy techniques, such as scanning electron microscopy (SEM), may also detect cryptic identifying characters, CLSM is less destructive to the specimens. Utilizing CLSM allows for subsequent examinations, such as molecular analyses, that cannot be performed following SEM sample preparation and imaging. Furthermore, CLSM detects intrinsic autofluorescence molecules, making improved identification independent of resource and time-intensive protocols. These aspects of CLSM make it an excellent method for assisting in taxonomic identification and for acquiring more detailed images of archaeoparasitological specimens.

Confocal Microscopy Measurement of the Fiber Orientation in Short Fiber Reinforced Plastics

  • Lee, Kwang Seok;Lee, Seok Won;Youn, Jae Ryoun;Kang, Tae Jin;Chung, Kwansoo
    • Fibers and Polymers
    • /
    • v.2 no.1
    • /
    • pp.163-172
    • /
    • 2001
  • To determine three-dimensional fiber orientation states in injection-molded short fiber composites a CLSM (Confocal Laser Scanning Microscope) is used. Since the CLSM optically sections the composites, more than two cross-sections either on or below the surface of the composite can be obtained. Three dimensional fiber orientation states can be determined with geometric parameters of fibers on two parallel cross-sections. For experiment, carbon fiber reinforced polystyrene is examined by the CLSM. Geometric parameters of fibers are measured by image analysis. In order to compactly describe fiber orientation states, orientation tensors are used. Orientation tensors are determined at different positions of the prepared specimen. Three dimensional orientation states are obtained without the difficulty in determining the out-of-plane angles by utilizing images on two parallel planes acquired by the CLSM. Orientation states are different at different positions and show the shell-core structure along the thickness of the specimen.

  • PDF

Confocal laser scanning microscopy image를 이용한 UASB granule의 메탄 생성 능력 측정

  • Lee, Yu-Jin;Kim, Hyo-Seop;An, Yeong-Hui;Park, Seong-Hun
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.365-369
    • /
    • 2000
  • Methanogenic activity of granular sludge was monitored by specific methanogenic activity (SMA) assay and confocal laser scanning microscopy (CLSM) during start-up of a thermophilic UASB reactor. Autofluorescence by CLSM could visualize the methanogenic bacterial population inside sludge granules and its intensity was proportional to SMA. Considering the complex procedures of SMA measurement, fluorescence quantification by CLSM can be suggested as a routine technique measuring methanogenic activity in UASB granules.

  • PDF

Indented Surface Configuration and its Volume Calculation (압입 표면형상의 구현과 체적계산법)

  • Yang, Jae-Yong;Yoon, Moon-Chul
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.708-713
    • /
    • 2012
  • The indented geometry for rockwell hardness indenter has been configured by using Confocal Laser Scanning Microscopy (CLSM). For this purpose, the CLSM can be well suited to construct the three-dimensional indented volume from the indented surface by rockwell hardness tester. Furthermore, the height data of HEI(height encoded image) by CLSM must be acquired at first and converted to indented surface later. And the indented surface patterns enable us to predict the indenter shape and volume. This volume can be used to study the rockwell hardness model as a volume parameter. As a result, the technique performed in this study by combining the CLSM with compensation technique is an excellent one to obtain the geometries of indented surfaces over a wide range of surface resolution in a micro scale. And it can be used for micro volume calculation.

Fiber Orientation in Injection-Molded Short Fiber Composites with a Confocal Laser Scanning Microscope and Numerical Simulation (공초점 레이저 주사 현미경을 이용한 단섬유 복합재료 사출 성형물 내의 섬유 배열 측정 및 수치모사)

  • Lee, Kwang-Seok;Le, Seok-Won;Youn, Jae-Ryoun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.201-204
    • /
    • 2001
  • A Confocal Laser Scanning Microscope (CLSM) is applied to determine three-dimensional fiber orientation states in injection-molded short fiber composites. Since the CLSM optically sections the composites, more than two planes either on or below the surface of composites can be obtained. Therefore, three dimensional fiber orientation states are determined without destruction. To predict the orientation states, velocity and temperature fields are calculated by using a hybrid FEM/FDM method. The change of orientation state during packing stage is also considered by employing a compressible Hele-Shaw model. The predicted orientation states show good agreement with measured ones. However, some differences are found at the end of cavity. They may result from other effects, which are not considered in the numerical analysis.

  • PDF

3-D Imaging in a Chaotic Micromixer Using Confocal Laser Scanning Microscopy (CLSM) (공초점 현미경을 이용한 마이크로믹서 내부의 3차원 이미지화)

  • Kim, Hyun-Dong;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.96-101
    • /
    • 2006
  • 3-D visualization using confocal laser scanning microscopy (CLSM) in a chaotic micromixer was performed as a reproduction experiment and the feasibility of 3-0 imaging technique in the microscale was confirmed. For diagonal micromixer (DM) and two types of staggered herringbone micromixers (SHM) designed by Whitesides et al., to verify the evolution of mixing, cross sectional images are reconstructed at the end of every cycle. In a DM, clockwise rotational flow motion generated by diagonal ridges placed on the floor of micromixer is observed and this motion makes the fluid commingle. On the contrary, there are two rotational flow structures in the SHM and the centers of rotation exchange their position each other every half cycle because of the V shape of ridges varying their orientation every half cycle. Local rotational flow and local extensional flow generated by the complicate ridge pattern make the flow be chaotic and accelerate the mixing of fluid. The dominant parameter that influences on the mixing characteristic of SHM is not the length of micromixer but the number of ridges under the same flow configurations.

  • PDF

STUDY OF INCIPIENT ENAMEL CARIES USING A DIGITAL ILLUMINATION FIBER-OPTIC TRANSILLUMINATION AND CONFOCAL LASER SCANNING MICROSCOPE (Digital Imaging Fiber-Optic Trans-Illuminational과 Confocal Laser Scanning Microscope를 이용한 초기 법랑질 우식증 연구)

  • Kim, Jae-Tae;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The purpose of this study were to evaluate the efficacy of the newly developed Digital Imaging Fiber-Optic Trans-illumination (DIFOTI) system in detecting carious lesions in vivo as gold standard with confocal laser scanning microscopy and compared the efficacy of traditional radiography and DIFOTI system in vito as gold standard with confocal laser scanning microscopy, too. For the in vivo study, the subject pool consisted of 23 grammar school age patients just prior to entering the mixed dentition phase Each patient was given a DIFOTI examination of the anterior and posterior teeth. During $6{\sim}8$ months, the naturally expire primary teeth were collected and the efficacy of DIFOTI system was compared with confocal laser scanning microscopy. For in vitro study, 40 primary teeth were collected and decalcified by Carbopol decalcification solution for 1, 2, 4 and 8 days. Every experiment period, all teeth were DIFOTI examined and sectioned to take an image of confocal laser scanning microscopy Sensitivity and specificity were calculated from the result of DIFOTI examine and confocal laser scanning microscopy analysis. The results are as follows : 1. From the in vivo study, the sensitivity of DIFOTI examine was 0. 61 and specificity was 0.63. 2. From the in vivo study, the sensitivity of DIFOTI examine was 0.71 and specificity was 0.75.

  • PDF

Three Dimensional Confocal Imaging and Biomedical Image Analysis (3차원 Confocal Imaging과 생체 영상 분석)

  • Lee, Yim-Kul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.257-261
    • /
    • 1995
  • Confocal laser scanning microscopy (CLSM)는 기존의 coherent or incoherent microscopic imaging 보다 횡축 방향 (lateral direction)으로 고해상도를 가지며, 층과 층 사이를 구분하는 광축 방향 (axial direction)의 optical sectioning에 의해 샘플의 3D 구조를 고해상도로 영상화함으로써 3D 구조 및 생체 기능 분석을 가능하게 해 준다. 본 논문에서는 CLSM에 의한 3D 영상화 원리와 촛점면 부근에서 얻어지는 광세기 분포, 얻어진 2D slice 영상의 시각화 및 응용에 대해 논의된다.

  • PDF

Flow Visualization of Blood Cell and Detection of Cell Depleted Layer Using a Confocal Laser Scanning Microscope (공초점 레이저 주사 현미경을 이용한 혈구 유동가시화 및 세포공핍층 측정에 관한 연구)

  • Lim, Soo-Hee;Kim, Wi-Han;Lee, Ho;Lee, Choon-Young;Park, Cheol-Woo
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.46-52
    • /
    • 2010
  • In the present study, we employed the confocal laser scanning microscopy (CLSM) system to visualize the blood flow field with $1{\times}1{\mu}m^2$ spatial resolution. Based on the confocal microscopic image of red blood cells (RBCs), we performed the velocity vector field measurement and evaluated characteristics of cell migration from the cell depleted layer thickness calculation. The rat and mouse's blood were supplied into a micro glass tubes in vitro. The line scanning rate of confocal microscopy was 15 kHz for a $500{\times}500$ pixels image. As a result, the red blood cell itself can be used as a tracer directly without any kind of invasive tracer particle to get the velocity vector field of blood flow by performing particle image velocimetry (PIV) technique.

Crater Wear Volume Calculation and Analysis (크레이터 마모의 체적계산 및 분석법)

  • Jeong, Jin-Seok;Cho, Hee-Geun;Yoon, Moon-Chul
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.3
    • /
    • pp.248-254
    • /
    • 2009
  • The worn crater wear geometry of coated tools after machining has been configured by using Confocal Laser Scanning Microscopy(CLSM) and the Wavelet-based filtering technique. The CLSM can be well suited to construct the three-dimensional crater wear on the rake surfaces of coated tips. However, The raw heightness data of HEI(height encoded image) acquired by CLSM must be filtered due to the electronic and imaging noise occurring in constructing the crater image. So the Wavelet-based filtering algorithm is necessary to denoise the shape features in a micro scales so as to realize accurate crater wear topography analysis. The crater wear patterns filtered enable us to predict the crater wear shape in order to study the tool wear evolution. The study shows that the technique by combining the CLSM and Wavelet-based filtering is an excellent one to obtain the geometries of worn tool rake surfaces over a wide range of surface resolution in a micro scale.

  • PDF