• Title/Summary/Keyword: Confocal Microscope

Search Result 315, Processing Time 0.025 seconds

A study on the effect of side-lobe on axial image of confocal microscope (공초점 광학현미경에서의 side-lobe 감소방안에 대한 연구)

  • 김억봉;류재연;최치규;김두철;유영훈
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.356-361
    • /
    • 2001
  • The effect of side-lobe on axial image is investigated. We show, using computer simulation and experimentally, that an optimized axial response can be achieved by minimized side-lobe according to the Herschel condition and that the appearance of sidelobes is decreased by balancing phase error.

  • PDF

In Vivo Evaluation of Multi Lamellar Vesicle Liposome’s Percutaneous Absorption and Stability

  • Joung, Min-Seok;Park, Jong-Oan;Seo, Bong-Seok;Ryu, Chang-Duck
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.27 no.1
    • /
    • pp.29-42
    • /
    • 2001
  • We had prepared MLV liposome with Hibiscus Esculentus Ext.(HEE) which have fluorescent light in order to evaluate its percutaneous absorption about hairless rat skin. Then we investigated particle size of MLV using confocal laser scanning microscope(CLSM) and transmission electron microscope(TEM), respectively. Stability of MLV liposome and penetration of MLV liposome to hairless rat skin was measured by CLSM. As a result of experiments, MLV was globular shape and the rage of particle size was 0.3-0.5$\mu\textrm{m}$ mostly. Cream-type MLV had high stability comparatively. When we treated with MLV to rat skin, skin penetration was enhanced, especially, the optimum concentration of MLV on penetration to rat skin was 10%. Optimum penetration time was 6hr-12hr. And MLV-type HEE was more effective on percutaneous absorption than HEE-cream or liposome-type HEE.

  • PDF

Effect of applied anodic current density on anodic oxidation behavior of AZ31 Mg alloy in OH-containing aqueous solution (수산화나트륨 수용액에서 AZ31 마그네슘 합금의 양극산하 거동에 미치는 인가 전류밀도의 영향)

  • Kim, Ye-Jin;Mun, Seong-Mo;Sin, Heon-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.98.2-98.2
    • /
    • 2017
  • 본 연구에서는 다양한 농도의 수산화나트륨 수용액에서 AZ31 마그네슘 합금의 양극산화 거동에 미치는 인가 전류밀도의 영향에 대해 알아보았다. 다양한 크기의 DC 전류를 인가하여 양극산화 거동을 확인하였으며, 형성된 피막의 표면구조를 optical microscope, confocal scanning laser microscope 등을 이용하여 관찰하였다. 연구결과, 인가 전류밀도에 따라 세 가지 유형의 voltage-time curve를 얻을 수 있었으며, voltage-time curve의 유형에 따라 서로 다른 피막 색상과 표면구조를 형성함을 발견하였다. 수산화나트륨 전해액에서 AZ31 마그네슘 합금의 플라즈마 전해산화 피막은 0.6 M 이상의 농도를 가진 수산화나트륨 용액에서 임계값 이상의 전류밀도를 인가하였을 경우에만 형성됨을 확인하였다.

  • PDF

Localization of Paclitaxel in Suspension Culture of Taxus chinensis

  • Choi, Hyung-Kyoon;Kim, Sang-Ic;Song, Jai-Young;Son;Hong, Seung-Suh;Durzan, Don-J.;Lee, Hyong-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.3
    • /
    • pp.458-462
    • /
    • 2001
  • The localization of paclitaxel was investigated in suspension culture cells of Taxus chinensis. Over 93% of the cell-associated paclitaxel were detected throughout the entire culture period. Intracellular localization of paclitaxel over the culture time was analyzed further by cell fractionation for days 21 and 42. Paclitaxel contents in intracellular organelles were decreased at day 42, while the content in the cell wall fraction was increased at day 42 compared to the value for day 21. The localization of paclitaxel in the cell wall was confirmed by using the immunocytochemical method with the aid of a confocal laser scanning microscope.

  • PDF

A study of loading property of the bioactive materials in porous Ti implants (다공성 티타늄 임플란트의 생리활성물질 담지특성에 관한 연구)

  • Kim, Yung-Hoon
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.281-286
    • /
    • 2013
  • Purpose: Surface modification is important techniques in modern dental and orthopedic implants. This study was performed to try embedding of bioactive materials in porous Ti implants. Methods: Porous Ti implant samples were fabricated by sintering of spherical Ti powders in a high vacuum furnace. It's diameter and height were 4mm and 20mm. Embedding process was used to suction and vacuum chamber. Loading properties of porous Ti implants were evaluated by scanning electron microscope(SEM), confocal laser scanning microscope(CLSM), and UV-Vis-NIR spectrophotometer. Results: Internal pore structure was formed fully open pore. Average pore size and porosity were $10.253{\mu}m$ and 17.506%. Conclusion: Porous Ti implant was fabricated successfully by sintering method. Particles are necking strongly each other and others portions were vacancy. This porous structure can be embedded to bioactive materials. Therefore bioactive materials will be able to embedding to porous Ti implants. Bioactive materials embedding in the porous Ti implant will induced new bone faster.

Autofluorescence of artificial incipient root carious lesions

  • Lee, Hyeong-Mo;Park, Jeong-Kil;Hur, Bock
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.615-615
    • /
    • 2003
  • I. Objectives This study was performed to get some information about micromorphology of subsurface lesion of root caries by observing autofluorescence using confocal laser scanning microscope(CLSM) with minimum sample preparation. II. Materials and Methods Half-cut and 1 mm thick sample of human teeth were prepared to produce artificial root carious lesions. Incipient subsurface lesions were produced under optimal pH and saturity. The lesions were observed by polarized microscopy, CLSM, and back-scattered electron microscope(BSE). Calcium and phosphorus concentrations of the lesions were analyzed by line EDAX. (omitted)

  • PDF

Phase-shifting diffraction grating interferometer for testing concave mirrors (오목 거울 측정용 위상천이 회절격자 간섭계)

  • 황태준;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.392-398
    • /
    • 2003
  • We present a novel concept of a phase-shifting diffraction-grating interferometer, which is intended for the optical testing of concave mirrors with high precision. The interferometer is configured with a single reflective diffraction grating, which performs multiple functions of beam splitting, beam recombination, and phase shifting. The reference and test wave fronts are generated by means of reflective diffraction at the focal plane of a microscope objective with large numerical aperture, which allows testing fast mirrors with low f-numbers. The fiber-optic confocal design is adopted for the microscope objective to focus a converging beam on the diffractive grating, which greatly reduces the alignment error between the focusing optics and the diffraction grating. Translating the grating provides phase shifting, which allows measurement of the figure errors of the test mirror to nanometer accuracy.

Preparation of Agar Microcapsules and Analysis of Their Internal Structure (한천 마이크로캡슐의 제조 및 내부구조 분석)

  • Park, Chul-Wan;Lee, Shin-Young;Hur, Won
    • KSBB Journal
    • /
    • v.22 no.4
    • /
    • pp.239-243
    • /
    • 2007
  • A method of forming agar microcapsule with fibroin coating was developed in this report. The capsules were prepared from a W/O emulsion of hot agar in mineral oil and were subsequently coated by fibroin. The capsules were harvested as precipitated aggregates, which can be dispersed in an aqueous media. The diameter of the microcapsule was less than $10{\mu}m$ by microscopic observation and 90% of them were between $1.32{\mu}m\;and\;6.0{\mu}m$. The structure of the aggregates and their dispersed microspheres were investigated by scanning electron microscope. Confocal microscopy was applied to visualize the core-shell structure of the agar microcapsule with fibroin coating. Thermogravimetric analysis (TGA) measured their composition to be agar 51.2%, fibroin 13.8%, Span 80 1.4% by weight.

Resonance May Elucidate New Bone Formation Induced by Low amplitude and High frequency Mechanical Stimuli (고주파 미세자극에 의한 뼈의 생성에 관한 모델링)

  • Yoon, Young June;Kim, Moon-Hwan;Bae, Cheol-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.3
    • /
    • pp.27-32
    • /
    • 2008
  • Bone is a self-assembly material. It is known that the low amplitude and high frequency mechanical stimulus, which is much less amplitude but higher frequency than those induced by the normal activity, can induce new bone formation. The vibrating resonance is employed to elucidate why new bone is formed by this kind of mechanical stimulus. For example, as 30 Hz and $5{\mu}{\epsilon}$ mechanical stimulus is applied at the wall of canaliculus (the tiny tube type pathway of bone fluid flow and the diameter of canaliculus is less than 200nm), the osteocytic cell membrane experiences $1,000{\mu}{\epsilon}$ strain due to the vibrating resonance. Two experiments will follow after this pilot study; (1) observing the MAPK pathway of osteocytes by using in-vitro cell culture and (2) visualizing the actin filament network in the osteocytes by using the imaging technique, such as confocal laser scanning microscope.

  • PDF

Evaluation of penetration depth of 2% chlorhexidine digluconate into root dentinal tubules using confocal laser scanning microscope

  • Vadhana, Sekar;Latha, Jothi;Velmurugan, Natanasabapathy
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.149-154
    • /
    • 2015
  • Objectives: This study evaluated the penetration depth of 2% chlorhexidine digluconate (CHX) into root dentinal tubules and the influence of passive ultrasonic irrigation (PUI) using a confocal laser scanning microscope (CLSM). Materials and Methods: Twenty freshly extracted anterior teeth were decoronated and instrumented using Mtwo rotary files up to size 40, 4% taper. The samples were randomly divided into two groups (n = 10), that is, conventional syringe irrigation (CSI) and PUI. CHX was mixed with Rhodamine B dye and was used as the final irrigant. The teeth were sectioned at coronal, middle and apical levels and viewed under CLSM to record the penetration depth of CHX. The data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests. Results: The mean penetration depths of 2% CHX in coronal, middle and apical thirds were $138{\mu}m$, $80{\mu}m$ and $44{\mu}m$ in CSI group, respectively, whereas the mean penetration depths were $209{\mu}m$, $138{\mu}m$ and $72{\mu}m$ respectively in PUI group. Statistically significant difference was present between CSI group and PUI group at all three levels (p < 0.01 for coronal third and p < 0.001 for middle and apical thirds). On intragroup analysis, both groups showed statistically significant difference among three levels (p < 0.001). Conclusions: Penetration depth of 2% CHX into root dentinal tubules is deeper in coronal third when compared to middle and apical third. PUI aided in deeper penetration of 2% CHX into dentinal tubules when compared to conventional syringe irrigation at all three levels.