• Title/Summary/Keyword: Confinement ratio

Search Result 291, Processing Time 0.02 seconds

Experimental study on flexural behavior of splicing concrete-filled GFRP tubular composite members connected with steel bars

  • Chen, B.L.;Wang, L.G.
    • Steel and Composite Structures
    • /
    • v.18 no.5
    • /
    • pp.1129-1144
    • /
    • 2015
  • Based on the experiment, this paper focuses on studying flexural behavior of splicing concrete-filled glass fiber reinforced polymer (GFRP) tubular composite members connected with steel bars. The test results indicated the confinement effects of GFRP tubes on the concrete core in compression zone began to produce, when the load reached about $50%P_u$ ($P_u$-ultimate load), but the confinement effects in tensile zone was unobvious. In addition, the failure modes of composite members were influenced by the steel ratio of the joint. For splicing unreinforced composite members, the steel ratio more than 1.96% could satisfy the splicing requirements and the steel ratio 2.94% was ideal comparatively. For splicing reinforced specimen, the bearing capacity of specimen with 3.92% steel ratio was higher 21.4% than specimen with 2.94% steel ratio and the latter was higher 21.2% than the contrast non-splicing specimen, which indicated that the steel ratio more than 2.94% could satisfy the splicing requirements and both splicing ways used in the experiment were feasible. So, the optimal steel ratio 2.94% was suggested economically. The experimental results also indicated that the carrying capacity and ductility of splicing concrete-filled GFRP tubular composite members could be improved by setting internal longitudinal rebars.

Axial behavior of CFRP wrapped RC columns of different shapes with constant slenderness ratio

  • Narule, Giridhar N.;Bambole, Abhay N.
    • Structural Engineering and Mechanics
    • /
    • v.65 no.6
    • /
    • pp.679-687
    • /
    • 2018
  • In composite materials technology, the fiber-reinforced polymers (FRP) have opened up new horizons in infrastructural engineering field for strengthening existing structures and components of structure. The Carbon fiber reinforced polymer (CFRP) sheets are well suited for RC columns to this application because of their high strength to weight ratio, good fatigue properties and excellent resistance to corrosion. The main focus of present experimental work is to investigate effect of shapes on axial behavior of CFRP wrapped RC columns having same cross-sectional area and slenderness ratio. The CFRP volumetric ratio and percentage of steel are also adopted constant for all the test specimens. A total of 18 RC columns with slenderness ratio four were cast. Nine columns were control and the rest of nine columns were strengthened with one layer of CFRP wrap having 35 mm of corner radius. Columns confined with CFRP wrap were designed using IS: 456:2000 and ACI 440.2R.08 provisions. All the test specimens were loaded for axial compression up to failure and failure pattern for each shaped column was investigated. All the experimental results were compared with analytical values calculated as per the ACI-440.2R-08 code. The test results clearly demonstrated that the axial behavior of CFRP confined RC columns is affected with the change in shapes. The axial deformation is higher in CFRP wrapped RC circular column as compared to square and rectangular columns. Stress-strain behaviour revealed that the yield strength gained from CFRP confinement was significant for circular columns as compare to square and rectangular columns. This behaviour may be credited due to effect of shape on lateral deformation in case of CFRP wrapped circular columns at effective confinement action.

Confinement Effects of Reinforced Concrete Tied Columns (철근콘크리트 띠철근 기둥의 구속효과)

  • 왕성근;한범석;이희수;신성우;반병열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.29-34
    • /
    • 2001
  • An experimental study was conducted to investigate the effectiveness of transverse reinforcement in reinforced concrete tied columns subjected to monotonically increasing axial compression. Eighteen large-scale columns(260$\times$260$\times$120mm) were fabricated to simulate similarly an actual structural members size. Effects of main variables such as the concrete compressive strength, the tie configuration, the transverse reinforcement ratio, the tie spacing, and the spatting of the concrete cover were studied in this research program.

  • PDF

An experimental Study on the Confinement Effect of Concrete specimens confined by Interlocking Spirals (조합된 나선근으로 횡보강된 콘크리트의 횡보강효과)

  • 김진근;박찬규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.306-311
    • /
    • 1994
  • Experimental research was carried out to investigate the confinement effect of concrete specimens confined by interlocking spirals subjected to the concentric axial compressive load. Main variables are the compressive strength of concrete with 2 levels(normal and high strength), the spacing of the spiral reinforcement, the yield strength of the spiral reinforcement with 2 levels and 4 different interlocking lengths. For the same volumetric ratio, the use of interlocking spirals is not as effective as the single spirals, provided that the spirals have the same diameter.

  • PDF

Axial load behavior and stability strength of circular tubed steel reinforced concrete (SRC) columns

  • Yan, Biao;Liu, Jiepeng;Zhou, Xuhong
    • Steel and Composite Structures
    • /
    • v.25 no.5
    • /
    • pp.545-556
    • /
    • 2017
  • The tubed steel reinforced concrete (SRC) column is a composite column in which the outer steel tube is mainly used to provide confinement on the core concrete. This paper presents experimental and analytical studies on the behavior of circular tubed SRC (TSRC) columns subjected to axial compression. Eight circular TSRC columns were tested to investigate the effects of length-to-diameter ratio (L/D) of the specimens, diameter-to-thickness ratio (D/t) of the steel tubes, and use of stud shear connectors on the steel sections. Elastic-plastic analysis on the steel tubes was used to investigate the mechanism of confinement on the core concrete. The test results indicated that the tube confinement increased the strength and deformation capacity for both short and slender columns, and the effects on strength were more pronounced for short columns. A nonlinear finite element (FE) model was developed using ABAQUS, in which the nonlinear material behavior and initial geometric imperfection were included. Good agreement was achieved between the predicted results using the FE model and the test results. The test and FE results were compared with the predicted strengths calculated by Eurocode 4 and the AISC Standard. Based on the analytical results, a new design method for this composite column was proposed.

Experimental behavior of eccentrically loaded RC slender columns strengthened using GFRP wrapping

  • Elwan, S.K.;Omar, M.A.
    • Steel and Composite Structures
    • /
    • v.17 no.3
    • /
    • pp.271-285
    • /
    • 2014
  • This paper aims to examine the behavior of slender reinforced concrete columns confined with external glass fiber reinforced polymers (GFRP) sheets under eccentric loads. The experimental work conducted in this paper is an extension to previous work by the author concerning the behavior of eccentrically loaded short columns strengthened with GFRP wrapping. In this study, nine reinforced concrete columns divided into three groups were casted and tested. Three eccentricity ratios corresponding to e/t = 0, 0.10, and 0.50 in one direction of the column were tested in each group. The first group was the control one without confinement with slenderness ratio equal 20. The second group was the same as the first group but fully wrapped with one layer of GFRP laminates. The third group was also fully wrapped with one layer of GFRP laminates but having slenderness ratio equal 15. The experimental results of another two groups from the previous work were used in this study to investigate the difference between short and slender columns. The first was control one with slenderness ratio equal 10 and the second was fully wrapped and having the same slenderness ratio. All specimens were loaded until failure. The ultimate load, axial deformation, strain in steel bars, and failure mechanisms of each specimen were generated and analyzed. The results show that GFRP laminates confining system is less effective with slender columns compared with short one, but this solution is still applied and it can be efficiently utilized especially for slender columns with low eccentric ratio.

Investigation of load transfer along interfaces of jacketed square columns

  • Achillopoulou, Dimitra V.
    • Structural Engineering and Mechanics
    • /
    • v.63 no.3
    • /
    • pp.293-302
    • /
    • 2017
  • This study deals with a numerical investigation of load transfer along interfaces of jacketed columns using finite element models. Appropriate plasticity and constitutive models are used to simulate the response of concrete and steel bars. Experimental data were used to calibrate the simulation of mechanical characteristics. The different compressive strength of core and jacket concrete, the confinement ratio, the dowels' diameter size and the load pattern shapes were considered. The path diagrams along the interfaces elucidate the areas around the dowel bars where due to stress concentration plastic hinges and intense discontinuities are created. The stress flow also depicts the contribution of confinement of the jacketed area to the overall resonant load capacity of the core column. The scope of the research is to identify and quantify the shear transfer along the interfaces of strengthened elements.

An Experimental Study on the Mechanical Properties of High Performance Concrete with Material for Lateral Confinement (횡구속 재료변화에 따른 고성능 콘크리트의 역학적 특성에 관한 실험적 연구)

  • 김은호;정덕우;홍상희;윤기원;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.563-568
    • /
    • 2002
  • This paper is a fundamental study on the mechanical properties of the high performance concrete confined with metal lath, glass and carbon fiber laterally. According to the results, it shows that the compressive strength increases by 9%, 8% and 6% in metal lath carbon fiber and glass fiber in case of W/B 30% respectively. In case of W/B 30% and 40%, flecxural strength shows largely in order of carbon fiber, metal lath, glass fiber. In strain-stress curve with the kinds of material for lateral confinement, while brittleness failure occurs in plain concrete just after maximum load, it is improved in some degree in confined concrete due to increase of the strain by increase of toughness. But, elastic modulus shows the similar tendency between confined concrete and plain concrete. Length change ratio by drying shrinkage shows little a bit in order of carbon fiber, glass fiber and metal lath due to confinement.

  • PDF

Reinforcement Efficiency of Concrete Compressive Members Confined with Carbon Fiber Sheet (탄소섬유쉬트로 횡보강된 콘크리트 압축부재의 보강성능에 관한 연구)

  • 성시문;강상용;임재형;이원호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.835-840
    • /
    • 2002
  • The purpose of this study is to analyze the reinforcement effect of the RC compressive member confined with carbon fiber sheets and to suggest better transverse confinement coefficient(k$_1$) than one's in the existing analysis equations. Showing amounts of CPS in terms of ratio of transverse reinforcement to cross-section, it comes to be possible to calculate the objective and quantitative reinforcement amounts and to estimate the overlapping length of CFS that can influence on all its confinement effect. The previous parameters were compared using the existing experimental test data, then analyzed for the merits and demerits of existing parameters through the coefficient of correlation(R). The proposed parameters were derived in such a way that established parameters and their combination were obtained from the analytical study and then determined by regression analysis using the previous test data.

  • PDF

Ground Response Curve for Ground Movement Analysis of Tunnel (지반응답곡선을 이용한 터널의 지반거동 분석)

  • Lee, Song;Ahn, Sung-Hak;Ahn, Tae-Hun;Kong, Sung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.4
    • /
    • pp.244-252
    • /
    • 2002
  • We must notice ground movement by excavation for reasonable tunnel designs. The convergence confinement method is an attempt to evaluate tunnel stability conditions by means of a mathematical model and a ground response curve. In this study, the convergence confinement method by numerical model was examined. This method don't need the basic assumptions for a mathematical model of circular tunnel shape, and hydrostatic in situ stress. Also modified ground response curve that is calculated after installing the support, is suggested, which informs us the ground movement mechanism. The ground response curve and the support reaction curve are mutually dependent. Especially the support reaction curve depends upon the ground response curve. The mechanism of tunnel must be analyzed by the interaction between support and ground. Consequently the stability of tunnel must be qualitatively investigated by a ground response curve and quantitatively adjudged by a numerical analysis for the reasonable design of tunnel.