• Title/Summary/Keyword: Configuration factor

Search Result 535, Processing Time 0.03 seconds

A study on the planning for construction and expanding of distribution substation considering contingency (상정사고를 고려한 배전용 변전소 신,증설 계획 수립에 관한 연구)

  • Choi, Sang-Bong;Kim, Dae-Kyeong;Jeong, Seong-Hwan;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Han, Sang-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.552-554
    • /
    • 2000
  • This paper presents algorithm to plan construction and expanding of substation considering contingency accidents by proposing utilization factor according to configuration of bank system. In this paper, at first, proper sphere of supply area in each district which could be standardized with respect to its supply capacity is established under assumption which was made long term load forecasting in district respectively. Secondly, goal of utilization ratio according to configuration of substation bank was set to keep reliability by remaining sound bank when it happen to one bank accidents Finally, optimal construction and expanding of substation considering economy and reliability simultaneously about substation to exceed these ratio could be anticipated.

  • PDF

Realization of High Speed All-Optical Half Adder and Half Subtractor Using SOA Based Logic Gates

  • Singh, Simranjit;Kaler, Rajinder Singh;Kaur, Rupinder
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.639-645
    • /
    • 2014
  • In this paper, the scheme of a single module for simultaneous operation of all-optical computing circuits, namely half adder and half subtractor, are realized using semiconductor optical amplifier (SOA) based logic gates. Optical XOR gate by employing a SOA based Mach-Zehnder interferometer (MZI) configuration is used to get the sum and difference outputs. A carry signal is generated using a SOA-four wave mixing (FWM) based AND gate, whereas, the borrow is generated by employing the SOA-cross gain modulation (XGM) effect. The obtained results confirm the feasibility of our configuration by proving the good level of quality factor i.e. ~5.5, 9.95 and 12.51 for sum/difference, carry and borrow, respectively at 0 dBm of input power.

Planning for Reasonable Construction and Expanding of Distribution Substation By Load Forecasting (부하예측에 의한 합리적인 배전용 변전소 증설계획 수립)

  • Choi, Sang-Bong;Kim, Dae-Kyeong;Jeong, Seong-Hwan;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Ho-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.92-94
    • /
    • 2000
  • This paper presents algorithm to plan construction and expanding of substation considering contingency accidents by proposing utilization factor according to configuration of substation bank system. In this paper, above all, proper sphere of supply area by each district which could be standardized with respect to its supply capacity is established under assumption of long term load forecasting which was made by district respectively, and then goal of utilization ratio based on configuration of substation bank was set to keep reliability by remaining sound bank when it happen to one bank accidents. Finally it is set up for optimal construction and expanding of substation considering economy and reliability simultaneously about substation to exceed these ratio.

  • PDF

Growth Characteristics and Life Prediction of Single Surface Fatigue Crack with the Variation of crack Configuration Ratios (균열 형상비 변화에 따른 단일표면파로균열의 성장특성과 수명예측)

  • 서창민;서덕영;정정수
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.173-181
    • /
    • 1993
  • This work has been investigated the ralationship between single surface crack length and crack depth have influence on the fatigue life. The simulation based on experimental results of 2.25 Cr-1Mo steel at various crack configuration ratios has enabled successful prediction of fatigue life at room temperature. The effect of crack depth should be considered for predicting fatigue crack growth rates as well as that of surface crack length. It is also shwn that the crack growth mechanisms are in good agreement with expreimental data according to the interaction of crack length and crack depth.

  • PDF

The Stability of Turbulent Interacting Flames (다수 난류 비예혼합 화염의 상호작용에 관한 연구)

  • Kim, Jin-Sun;Lee, Byeong-Jun
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.453-458
    • /
    • 2001
  • The stability of turbulent nonpremixed interacting flames is investigated in terms of nozzle configuration shapes which depend on the existence of the center nozzles. Six nozzle arrangements which are cross 4, 5, 8, 9, square 8 and circular 8 nozzles are used for the experiment. Those are arranged to see the effect of the center nozzle out of multi-nozzle. There are many parameters that affect flame stability in multi-nozzle flame such as nozzle separation distance, fuel flowrates and nozzle configuration, but the most important factor is the existence of nozzles in the center area from the nozzle arrangement. As the number of nozzle in the area is reduced, more air can be entrained into the center of flame base and then tag flame is formed. In the case of circular 8 nozzles, blowout flowrates are above 5.4 times compared with that of single equivalent area nozzle.

  • PDF

Performance Variations of Vaned Diffusers with Solidity and Exit Vane Angle (베인 디퓨저의 솔리디티와 출구 유동각에 따른 성능변화)

  • Cho, S.K.;Kang, S.H.;Cha, B.J.;Lee, D.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.422-427
    • /
    • 2000
  • The design of low-solidity vaned diffusers and the effect on the performance of a turbocharger compressor is discussed. The effect of vane number and turning angle was investigated while maintaining a basic design with a leading edge angle of $70^{\circ}$, leading and trailing edge radius ratios of 1.1 and 1.3. All results are compared with those obtained with the standard vaneless diffuser configuration and it was shown that all designs increased and shifted the pressure ratio to reduced flowrates. Despite the low-solidity configuration none of the vane designs provided a broad operating range, and the vane leading edge angle was not main factor that system went into the surge condition. The diffuser of higher trailing edge angle improved the flow range for the compressor to operate at lower flow region.

  • PDF

A Study on the Analytical Approach for Reliability Assessment Considering Interruption Cost in Distribution Systems (정전비용특성을 고려한 배전계통의 신뢰도평가에 관한 연구)

  • Song, Seok-Hwan;Rho, Dae-Seok;Choi, Jae-Seok;Cha, Jun-Min
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.270-272
    • /
    • 2001
  • This paper deals with the analytical approach for the reliability assessment in radially operated distribution systems. The approach can estimate the expected reliability performance of distribution systems by a direct assessment of the configuration of the systems using the reliability indexes such as NDP(Non-Delivery Power) and NDE(Non-Delivery Energy). The indexes can consider the number and configuration of the load, but can not consider the characteristics of the load which is the one of the most important factor in the investment cost for the distribution systems. Therefore, This paper presents the new indexes considering the expected interruption cost for the load section and shows the effectiveness by simulating at the model systems.

  • PDF

A Study on the Optimal Investment Method for Distribution Systems Interconnected with Dispersed Generations (분산전원이 연계된 배전계통의 최적 설비투자 방안에 관한 연구)

  • Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2179-2185
    • /
    • 2008
  • This paper deals with the optimal investment method for distribution facilities, based on the analytical approach for the reliability assessment in distribution systems interconnected with new dispersed generations. The existing approach can estimate the expected reliability performance of distribution systems by a direct assessment of the configuration of the systems using the reliability indexes such as NDP(Non-Delivery Power) and NDE(Non-Delivery Energy). The indexes can only consider the number and configuration of the load, but can not consider the characteristics of the load which is the one of the most important factor in the investment cost for the distribution systems. Therefore, this paper presents the new performance indexes for the investment of the distribution facilities considering both the expected interruption cost for the load section and the operation characteristics of dispersed generations. The results from a case study show that the proposed methods can be a practical tool for the voltage management in distribution systems including dispersed sources.

A Study on the Safely of Vibration Characteristics on the Various Configuration of Tube (튜브 형상에 따른 진동 특성의 안전성 연구)

  • 신귀수
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.45-51
    • /
    • 2000
  • This paper studies the effect of vibrational characteristics of the various tubes analyzed though experiment. By an experiment analysis we found out that the factor of system vibration is fluid-structure interaction of tube line. In fluid-filled tube system we study on the influence that the natural frequency of system and the frequency of wave motion produce upon through three experiments. Three experiments are modal test on each tube, FRF in continuous system, and vibrating tests when the system is driving on. From the results of the experimental studies, we obtained that the natural frequencies of system are very important than wave induced vibrations. and according to the variation of configuration, the frequencies are different each other. And we found that though fluid passed away through the tube, the tendency of system vibration level was similar with the mode shape at the simple system.

  • PDF

Reliability Assessment Considering Load Characteristics in Distribution Systems (배전계통에서 부하특성을 고려한 신뢰도평가에 관한 연구)

  • Park, Hyeon-Seok;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.05a
    • /
    • pp.87-90
    • /
    • 2008
  • This paper deals with the analytical approach for the reliability assessment in radially operated distribution systems. The approach can estimate the expected reliability performance of distribution systems by a direct assessment of the configuration of the systems using the reliability indexes such as NDP(Non-Delivery Power) and NDE(Non-Delivery Energy). The indexes can consider the number and configuration of the load, but can not consider the characteristics of the load which is the one of the most important factor in the investment cost for the distribution systems. Therefore, This paper presents the new indexes considering the expected interruption cost for the load section and shows the effectiveness by simulating at the model systems.

  • PDF