• 제목/요약/키워드: Cone Resistance

검색결과 198건 처리시간 0.02초

소형콘관입시험(Miniature Cone Penetration Test)의 국내현장 적용 (The Field Application of Miniature Cone Penetration Test System in Korea)

  • 윤성수;지완구;김준오;김래현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.349-360
    • /
    • 2009
  • The cone penetration test(CPT) has gained its popularity in site characterization indebted by its reliability, speed, economy, and automatic measurement system since its development in the 1930s. The CPT results, commonly consisting of cone tip resistance, sleeve friction, and pore water pressure measurements, allow us to classify soils as well as to reveal their engineering characteristics. The site condition at which the CPT is allowable is often dependent on the capacity of a CPT system. In Korea, it has been considered that the CPT could be appled only to soft soils in most cases because CPT systems available for stiff soils are very rare due to their expensive procurement and maintenance cost. Luoisiana Transportation Research Center(LTRC) has developed and implemented a field-rugged continuous intrusion miniature cone penetration test(CIMCPT) system since the late 1990s. The miniature cone penetrometer has a sectional cone area of $2cm^2$ allowing system capacity reduction compared to the standard $10cm^2$ cone penetrometer. The continuous intrusion mechanism allows fast and economic site investigation. Samsung Engineering & Construction has recently developed and implemented a similar CIMCPT system based on its original version developed in LTRC. The performance of the Samsung CIMCPT system has been investigated by calibration with the standard CPT system at a well-characterized test site in Pusan, Korea. In addition, scale effect between the miniature cone penetrometer and the standard cone penetrometer has been investigated by comparing the field test results using the both systems.

  • PDF

대불간척지 충적점토의 공학적 특성에 관한 연구 (A Study on the Engineering Properties of Alluvial clay in the Daebul Reclaimed Tideland)

  • 김홍일;진병익;유기송
    • 한국농공학회지
    • /
    • 제26권1호
    • /
    • pp.29-37
    • /
    • 1984
  • This study was made to find several significant relations among various physical and mechanical properties including cone penetration resistance. The alluvial clay samples were taken at the Daebul Reclaimed Tideland in Samhomyeon, Yeongamgun, Jeonranamdo. The results of the study are summarized as follows; 1.Most samples belong to medium or high plastic, inorganic, silty clay(clay contents;32-64%, silt contents; 36-68%, sand contents; 0-3%). The specific gravities range from 2.70 to 2.73, the unit weights from 1.45 to 1. 75g/cm$^3$, the natural moisture contents from 45 to 77%, the liquid limits from 32 to 56%. It is certain that the foundation is weak because the natural moisture contents are much higher than the liquid limits. 2.It is known from the shear tests that the unconfined compression strenghs vary from 0.09 to 0. 38kg/cm2, the cohesions from 0.05 to 0. 21kg/cm2, the internal friction angles from 0 to 3˚. 3.The consolidation tests show that the initial void ratios range from 1.25 to 2.28, the compression indeices from 0.43 to 0.84, the preconsolidation loads from 0.21 to 0.74kg/cm$^2$. 4.Cone penetration resistances are usually less than 5kg/cm$^2$ from ground surface to the depth of about 8m, and from S to l0kg/cm$^2$ in the layer below about 8m to hard layer. 5.The cohesion and cone penetration resistance are in proportion to the depth of soil layer. 6.The correlations between various physical and mechanical properties including cone penetration resistance for the alluvial clay samples are as follows; a) Wn=0.944C+ l2.733 (r=0.829) b) LL=0. 728Cy+6. 991 (r=0. 873) c) PI=0.659Cy-8.168 (r=0.860) d) rt=0. 0077(272-Wn) =2.092-0. 0077Wn (r=0. 859) e) 60=0. 035wn-0 447 (r=0. 893) f) C=0.380qw+0.031 (r=0.816) g) qu=0.0707qc+0.029 (r=0.810) h) C=0.018Z+0.055 (r=O.802) I) qc=0. 415Z+1, 438 (r=0. 943)

  • PDF

협재층 탐지를 위한 선단비저항 콘 (Cone Resistivity Penetrometer for Detecting Thin-Layered Soils)

  • 윤형구;정순혁;김래현;이종섭
    • 한국지반공학회논문집
    • /
    • 제26권8호
    • /
    • pp.15-25
    • /
    • 2010
  • 점토층 사이에 존재하는 모래 협재층은 연약지반 거동에 중요한 영향을 미친다. 협재층은 주로 표준 콘(단면적: $10cm^2$)에서 측정된 지반의 저항력과 간극수압 값을 이용하여 평가하고 있지만, 높은 해상도를 위하여 소형 콘이 널리 활용되고 있다. 본 논문의 목적은 연약지반에 얇게 분포된 협재층을 선단저항력, 주면마찰력 그리고 전기비저항을 이용하여 평가할 수 있는 전기비저항 콘(Cone Resistivity Penetrometer, CRP)을 개발하고 적용하는 것이다. CRP는 각각 실내실험(단면적: $0.78cm^2$, 직경: 1.0cm)과 현장실험(단면적: $1.76cm^2$, 직경: 1.5cm)에 활용되도록 제작하였으며, 길이는 표준 콘(단면적: $10cm^2$, 직경: 3.57cm)의 단면적과 마찰부의 면적비를 고려하여 제작하였다. 실내실험은 모래와 점토가 반복적으로 조성된 다층의 층상탐지 셀을 사용하여 각 지층의 경계면을 탐사하였으며, 현장실험은 광양지역에서 심도 6m부터 15m까지 관입실험을 수행하였다. CRP는 실내실험에서 측정된 선단저항력과 전기비저항으로 조성된 시료의 각 지층 경계면을 뚜렷하게 평가하였으며, 현장실험에서는 3개의 협재층을 탐지하였다. 본 연구에서 개발된 CRP는 실내 및 현장결과 적용성이 뛰어나 추후 유용하게 사용될 것으로 판단된다.

Rod effects on transferred energy into SPT sampler using smart measurement system

  • Park, Geunwoo;Kim, Namsun;Hong, Won-Taek;Lee, Jong-Sub
    • Smart Structures and Systems
    • /
    • 제30권2호
    • /
    • pp.159-172
    • /
    • 2022
  • To improve the accuracy of the standard penetration test (SPT) results, smart measurement system, which considers the energy transfer ratio into the sampler (ETRSampler), is required. The objective of this study is to evaluate the effects of joints and rod length on the transferred energy into the sampler. The energy transfer ratios into the rod head (ETRHead) and ETRSampler, and the energy ratio from the head to the sampler (ERHS) were obtained using energy modules, which were installed at the rod head and above the SPT sampler. Linear regression analyses are conducted to correlate the ERHS with the number of joints, rod length, and SPT N-values. In addition, the dynamic resistances are calculated using both transferred energies into the rod head and into the sampler, and are compared with the corrected cone tip resistance measured from the cone penetration test (CPT). While the ETRHead are generally constant, but the ETRSampler and ERHS gradually decrease along the depth or the number of joints, except at certain depths with high SPT N-values. Thus, the ERHS can be estimated using the number of joints, rod length, and SPT N-values. The dynamic resistance evaluated by ESampler produces a better correlation with the corrected cone tip resistance than that by EHead. This study suggests that transferred energy into the SPT sampler may be effectively used for more accurate subsurface characterization.

소형콘관입시험(Miniature CPT)의 국내현장적용 사례분석 (Case Studies on the Field Application of Miniature CPT's in South Korea)

  • 윤성수;황대진;김준오;지완구
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.269-281
    • /
    • 2010
  • The cone penetration test(CPT) has been increasingly used for in situ site characterization. However, the use of CPT is often limited due to specific site conditions depending on the cone size, geometry, and capacity of the CPT system used. In South Korea, it has generally been considered that the CPT could be satisfactorily performed only in soft soils. Louisiana State University/ Louisiana Transportation Research Center has implemented a field-rugged continuous intrusion miniature cone penetration test (CIMCPT) system since the 1990s. The miniature cone penetrometer of the CIMCPT system has a cross-sectional cone area of $2cm^2$ allowing finer soil profiles compared to the standard $10cm^2$. The reduced cross-sectional area also enables a system capacity reduction leading to cost saving and ease in maintenance. In addition, the continuous intrusion mechanism allows fast and economic site investigations. Samsung C&T Corporation has recently implemented a similar CIMCPT system. In this study, case studies on the field application of Samsung CIMCPT system for the last 2 years are presented to illustrate its performance investigation and its usefulness and limitation. Results of the case studies show that the CIMCPT system can be applied to soils with cone tip resistance($q_c$) values up to about 30MPa and allows a reliable and useful way to characterize soft soils. The results also show that the rod buckling limits the investigation depth by the system and the large contact pressure of the CIMCPT truck prevents the use of the system at sites with soft surface soils. According to the results of the case studies, the Samsung CIMCPT system has been being upgraded with a miniature cone with a longer rod, a crawler-type transportation system, a pre-boring system, and so on.

  • PDF

지중의 온도변화가 콘 선단저항력에 미치는 영향 (Effect of the Temperature Change on the Cone Tip Resistance)

  • 김래현;이우진;윤형구;이종섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.361-367
    • /
    • 2009
  • The criteria such as ASTM recommends that the zero reading process of CPT must be performed in the same temperature condition with underground in order to reduce the effect of temperature. However, this method can not consider the change of temperature occurred during penetration. In this study, ultra small size temperature sensor with 0.5mm in diameter is manufactured to estimate and compensate the effect of temperature by using FBG sensor. The continuous temperature changes are monitored during cone penetration by using FBG temperature sensor installed in cone penetrometer. The temperature compensated tip resistances show the uniform and similar distributions with depth in different with originally measured tip resistance in cohesive soil. This study verifies that the tip resistances measured by previous zero reading method are affected by the change of underground temperature, and suggests the new temperature compensation technique using by FBG temperature sensor.

  • PDF

CPT-based lateral displacement analysis using p-y method for offshore mono-piles in clays

  • Kim, Garam;Park, Donggyu;Kyung, Doohyun;Lee, Junhwan
    • Geomechanics and Engineering
    • /
    • 제7권4호
    • /
    • pp.459-475
    • /
    • 2014
  • In this study, a CPT-based p-y analysis method was proposed for the displacement analysis of laterally loaded piles. Key consideration was the continuous soil profiling capability of CPT and cone resistance profiles that do not require artificial assumption or simplification for input parameter selection. The focus is on the application into offshore mono-piles embedded in clays. The correlations of p-y function components to the effective cone resistance were proposed, which can fully utilize CPT measurements. A case example was selected from the literature and used to validate the proposed method. Various parametric studies were performed to examine the effectiveness of the proposed method and investigate the effect of property profile and its depth resolution on the p-y analysis. It was found that the calculation could be largely misleading if wrongly interpreted sub-layer condition or inappropriate resolution of input soil profile was involved in the analyses. It was also found that there is a significant influence depth that dominates overall load response of pile. The soil profile and properties within this depth range affect most significantly calculated load responses, confirming that the soil profile within this depth range should be identified in more detail.

무기 입자 강화제와 브롬(Br) 난연제에 따른 폴리프로필렌 복합재료의 난연성 향상에 관한 연구 (Fire Resistance Study of PP Thermoplastic Composites with Particulate Reinforcements and Br Flame Retardants)

  • 곽성복;황성덕;남재도;고재송;최형기
    • 폴리머
    • /
    • 제26권2호
    • /
    • pp.260-269
    • /
    • 2002
  • 본 연구에서는 범용 열가소성수지인 폴리프로필렌에 다양한 입자 강화제로 무기질 폐기 제올라이트, 탈크, 탄산칼슘 등을 첨가하여 소재를 복합재료화 하였다. 또한 입자 사이즈에 따른 열안정성과 입자 강화제에 따른 난연 특성을 확인하였다. 본 연구에서는 입도 분석 결과 폐기 제올라이트가 85.34 $mu extrm{m}$, 탄산칼슘이 33.93 $mu extrm{m}$, 탈크가 18.51 $mu extrm{m}$의 평균 입자 크기를 가지고 있는 것을 확인하였다. 난연성 측정으로 산소지수(LOI, ASTM D2863)와 콘 칼로리미터 (ASTM E1354 ISO 5660)를 사용하였으며, 열 안정성 측정으로는 TGA를 사용하였다. 입자 강화제와 난연제 DBDPO를 사용한 결과 최대 열 방출 속도(M-HRR)는 탈크>탄산칼슘>폐기 제올라이트 순으로 감소됨을 확인하였다. 콘 칼로리미터 실험 결과, 난연제 DBDPO만 혼합하였을 경우보다 입자 강화제를 첨가 혼합하였을 경우가 난연 효율이 대략 2배 정도 향상됨을 확인하였다. 또한 산소지수 결과도 콘 칼로리미터와 유사한 경향을 보임을 확인하였다. 광학현미경(OM)과 주사전자현미경(SEM)을 사용하여 입자 강화된 복합재료의 연소되는 과정의 단면을 연소 단계별로 관찰함으로써 연소 표면에서의 입자 강화제의 배열 양상 및 산소 공급의 특성 등을 연구하였다.

Design of a piezovibrocone and calibration chamber

  • Samui, Pijush;Sitharam, T.G.
    • Geomechanics and Engineering
    • /
    • 제2권3호
    • /
    • pp.177-190
    • /
    • 2010
  • This paper presents the details of indigenous development of the piezovibrocone and calibration chamber. The developed cone has a cylindrical friction sleeve of $150cm^2$ surface area, capped with a $60^{\circ}$ apex angle conical tip of $15cm^2$ cross sectional area. It has a hydraulic shaker, coupled to the cone penetrometer with a linear displacement unit. The hydraulic shaker can produce cyclic load in different types of wave forms (sine, Hover sine, triangular, rectangular and external wave) at a range of frequency 1-10 Hz with maximum amplitude of 10 cm. The piezovibrocone can be driven at the standard rate of 2 cm/sec using a loading unit of 10 ton capacity. The calibration chamber is of size $2m{\times}2m{\times}2m$. The sides of the chamber and the top as well as the bottom portions are rigid. It has a provision to apply confining pressure (to a maximum value of $4kg/cm^2$) through the flexible rubber membrane inlined with the side walls of the calibration chamber. The preliminary static as well as dynamic cone penetration tests have been done sand in the calibration chamber. From the experimental results, an attempt has been made to classify the soil based on friction ratio ($f_R$) and the cone tip resistance ($q_c$).

Suction Drain 공법에서 양방향 압력재하에 의한 효율 평가에 관한 연구 (A study on evaluation of duplex loading pressure in Suction Drain Method)

  • 안동욱;채광석;한상재;윤명석;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1256-1263
    • /
    • 2010
  • Suction Drain Method is soft ground improvement technique, in which a vacuum pressure can be directly applied to the Vertical Drain Board to promote consolidation and strengthening the soft ground. This method does not require a surcharge load, different to embankment or Preloading Method. In this study, ground improvement efficiency of suction drain method was estimated when duplex loading pressure with vacuum and pressure. During suction drain method process, surface settlement and pore pressure were monitored, and cone resistance test as well as water content were also measured after the completion of Suction Drain Method treatment.

  • PDF