• 제목/요약/키워드: Cone Beam Computed Tomography(CBCT)

검색결과 552건 처리시간 0.02초

Ameloblastoma with dystrophic calcification: A case report with 3-dimensional cone-beam computed tomographic images of calcification

  • Kang, Byung Cheol;Lee, Jae Seo;Yoon, Suk Ja;Kim, Young
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.373-376
    • /
    • 2020
  • This report presents a rare case of ameloblastoma with histopathologic and radiographic calcification, including 3-dimensional cone-beam computed tomographic (CBCT) images. A 22-year-old woman had hard swelling on the right mandible. Panoramic and CBCT images showed multilocular radiolucencies with internal calcification foci in the right mandible. Three-dimensional images clearly showed varying-sized radiopacities within the lesion from various angles. A histopathologic examination showed central squamous differentiation and more densely packed peripheral palisading ameloblastic cells. Many areas of keratin pearls and calcifications were also seen. Four previous reports have described 5 cases of ameloblastoma showing histopathologic calcification. This might be the first report to present the calcification of ameloblastoma on panoramic and CBCT images, especially on 3-dimensional images.

측두하악관절 골관절염 환자의 진단에서 Cone Beam 전산화 단층촬영의 유용성 (The Usefulness of Cone Beam Computed Tomography in Diagnosis of Temporomandibular Joint Osteoarthritis)

  • 노창세;정연화;태일호;고명연;안용우
    • Journal of Oral Medicine and Pain
    • /
    • 제34권1호
    • /
    • pp.81-90
    • /
    • 2009
  • 2005년부터 2007년까지 진주 OOO치과의원 턱관절/구강안면통증클리닉에 내원한 측두하악장애환자 95명, 190개의 관절을 대상으로 한 명의 검사자가 측두하악관절장애 분석검사와 파노라마영상검사를 엄격히 시행하고, CBCT영상을 촬영하여 구강내과 전문의와 치과방사선과 전문의가 각각 영상진단 하였으며, 임상적 진단과 CBCT영상의 결과를 비교하여 다음과 같은 결과를 얻었다. 1. 구강내과 전문의와 치과방사선과 전문의에 의한 CBCT의 영상진단의 일치도(Kappa: 0.681)가 높았다. 2. 파노라마영상과 CBCT의 영상진단과의 일치도(Kappa: 0.169)가 낮으며, 파노라마영상에서 골변화의 위음성이 높았다. 3. 임상적으로 비퇴행성골관절염으로 진단된 관절 중 CBCT의재진단시 54.2%에서 골변화가 관찰되었으며, 퇴행성골관절염으로 진단된 관절 중 CBCT의 재진단시 15.3%에서 골변화가 없는 것으로 관찰되었다. 4. 관절통은 침식성 골변화에서 높게 나타났으며, 골증식체의 골변화에서 염발음이 가장 많이 나타났으며 병력기간도 가장 길었다.

Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

  • Tasanapanont, Jintana;Apisariyakul, Janya;Wattanachai, Tanapan;Sriwilas, Patiyut;Midtbo, Marit;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.117-122
    • /
    • 2017
  • Purpose: The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Materials and Methods: Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient(ICC) was used to assess intraobserver reliability. Results: The root surface area measurements ($230.11{\pm}41.97mm^2$) obtained using CBCT were slightly greater than those ($229.31{\pm}42.46mm^2$) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. Conclusion: This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

A comparative study of cone-beam computed tomography and digital panoramic radiography for detecting pulp stones

  • Tassoker, Melek;Magat, Guldane;Sener, Sevgi
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.201-212
    • /
    • 2018
  • Purpose: The aim of this study was to compare cone-beam computed tomography (CBCT) and digital panoramic radiography (DPR) for the detection of pulp stones. Materials and Methods: DPR and CBCT images of 202 patients were randomly selected from the database of our department. All teeth were evaluated in sagittal, axial, and coronal sections in CBCT images. The systemic condition of patients, the presence of pulp stones, the location of the tooth, the group of teeth, and the presence and depth of caries and restorations were recorded. The presence of pulp stones in molar teeth was compared between DPR and CBCT images. Results: Pulp stones were identified in 105 (52.0%) of the 202 subjects and in 434 (7.7%) of the 5,656 teeth examined. The prevalence of pulp stones was similar between the sexes and across various tooth locations and groups of teeth (P>.05). A positive correlation was observed between age and the number of pulp stones(${\rho}=0.277$, P<.01). Pulp stones were found significantly more often in restored or carious teeth (P<.001). CBCT and DPR showed a significant difference in the detection of pulp stones(P<.001), which were seen more often on DPR than on CBCT. Conclusion: DPR, as a 2D imaging system, has inherent limitations leading to the misinterpretation of pulp stones. Restored and carious teeth should be carefully examined for the presence of pulp stones. CBCT imaging is recommended for a definitive assessment in cases where there is a suspicion of a pulp stone on DPR.

Comparing the precision of panoramic radiography and cone-beam computed tomography in avoiding anatomical structures critical to dental implant surgery: A retrospective study

  • Ozalp, Oznur;Tezerisener, Huseyin Alican;Kocabalkan, Burak;Buyukkaplan, Ulviye Sebnem;Ozarslan, Mehmet Mustafa;Kaya, Goksel Simsek;Altay, Mehmet Ali;Sindel, Alper
    • Imaging Science in Dentistry
    • /
    • 제48권4호
    • /
    • pp.269-275
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the correlations between measurements made using panoramic radiography and cone-beam computed tomography (CBCT) based on certain anatomical landmarks of the jaws, with the goal of preventing complications due to inaccurate measurements in the pre-surgical planning phase of dental implant placement. Materials and Methods: A total of 56 individuals who underwent panoramic radiography and a CBCT evaluation before dental implant surgery were enrolled in the study. Measurements were performed to identify the shortest vertical distance between the alveolar crest and neighboring anatomical structures, including the maxillary sinus, nasal floor, mandibular canal, and foramen mentale. The differences between the measurements on panoramic radiography and CBCT images were statistically analyzed. Results: Statistically significant differences were observed between the measurements on panoramic radiography and CBCT for all anatomical structures (P<.05). The correlation coefficients (r) between the paired samples obtained from panoramic radiography and CBCT were closely correlated (P<.05), with r values varying from 0.921 and 0.979 for different anatomical regions. Conclusion: The results of this study support the idea that panoramic radiography might provide sufficient information on bone height for preoperative implant planning in routine cases or when CBCT is unavailable. However, an additional CBCT evaluation might be helpful in cases where a safety margin cannot be respected due to insufficient bone height.

Dental students' ability to detect maxillary sinus abnormalities: A comparison between panoramic radiography and cone-beam computed tomography

  • Rosado, Lucas de Paula Lopes;Barbosa, Izabele Sales;de Aquino, Sibele Nascimento;Junqueira, Rafael Binato;Verner, Francielle Silvestre
    • Imaging Science in Dentistry
    • /
    • 제49권3호
    • /
    • pp.191-199
    • /
    • 2019
  • Purpose: To compare the diagnostic ability of undergraduate dental students to detect maxillary sinus abnormalities in panoramic radiographs(PR) and cone-beam computed tomography (CBCT). Materials and Methods: This was a retrospective study based on the evaluation of PR and CBCT images. A pilot study was conducted to determine the number of students eligible to participate in the study. The images were evaluated by 2 students, and 280 maxillary sinuses were assessed using the following categories: normal, mucosal thickening, sinus polyp, antral pseudocyst, nonspecific opacification, periostitis, antrolith, and antrolith associated with mucosal thickening. The reference standard was established by the consensus of 2 oral radiologists based on the CBCT images. The kappa test, receiver operating characteristic curves, and 1-way analysis of variance with the Tukey-Kramer post-hoc test were employed. Results: Intraobserver and interobserver reliability showed agreement ranging from substantial (0.809) to almost perfect (0.922). The agreement between the students' evaluations and the reference standard was reasonable (0.258) for PR and substantial(0.692) for CBCT. Comparisons of values of sensitivity, specificity, and accuracy showed that CBCT was significantly better(P<0.05). Conclusion: CBCT was better than PR for the detection of maxillary sinus abnormalities by dental students. However, CBCT should only be requested after a careful analysis of PR by students and more experienced professionals.

Projected lifetime cancer risk from cone-beam computed tomography for orthodontic treatment

  • Jha, Nayansi;Kim, Yoon-Ji;Lee, Youngjun;Lee, Ju Young;Lee, Won Jin;Sung, Sang-Jin
    • 대한치과교정학회지
    • /
    • 제51권3호
    • /
    • pp.189-198
    • /
    • 2021
  • Objective: To estimate the projected cancer risk attributable to diagnostic cone-beam computed tomography (CBCT) performed under different exposure settings for orthodontic purposes in children and adults. Methods: We collected a list of CBCT machines and their specifications from 38 orthodontists. Organ doses were estimated using median and maximum exposure settings of 105 kVp/156.8 mAs and 130 kVp/200 mAs, respectively. The projected cancer risk attributable to CBCT procedures performed 1-3 times within 2 years was calculated for children (aged 5 and 10 years) and adult (aged 20, 30, and 40 years) male and female patients. Results: For maximum exposure settings, the mean lifetime fractional ratio (LFR) was 14.28% for children and 0.91% for adults; this indicated that the risk to children was 16 times the risk to adults. For median exposure settings, the mean LFR was 5.25% and 0.58% for children and adults, respectively. The risk of cancer decreased with increasing age. For both median and maximum exposure settings, females showed a higher risk of cancer than did males in all age groups. Cancer risk increased with an increase in the frequency of CBCT procedures within a given period. Conclusions: The projected dental CBCT-associated cancer risk spans over a wide range depending on the machine parameters and image acquisition settings. Children and female patients are at a higher risk of developing cancer associated with diagnostic CBCT. Therefore, the use of diagnostic CBCT should be justified, and protective measures should be taken to minimize the harmful biological effects of radiation.

Comparison of limited- and large-volume cone-beam computed tomography using a small voxel size for detecting isthmuses in mandibular molars

  • de Souza Tolentino, Elen;Andres Amoroso-Silva, Pablo;Alcalde, Murilo Priori;Yamashita, Fernanda Chiguti;Iwaki, Lilian Cristina Vessoni;Rubira-Bullen, Izabel Regina Fischer;Duarte, Marco Antonio Hungaro
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.27-34
    • /
    • 2021
  • Purpose: This study was performed to compare the ability of limited- and large-volume cone-beam computed tomography (CBCT) to display isthmuses in the apical root canals of mandibular molars. Materials and Methods: Forty human mandibular first molars with isthmuses in the apical 3 mm of mesial roots were scanned by micro-computed tomography (micro-CT), and their thickness, area, and length were recorded. The samples were examined using 2 CBCT systems, using the smallest voxels and field of view available for each device. The Mann-Whitney, Friedman, and Dunn multiple comparison tests were performed (α=0.05). Results: The 3D Accuitomo 170 and i-Cat devices detected 77.5% and 75.0% of isthmuses, respectively (P>0.05). For length measurements, there were significant differences between micro-CT and both 3D Accuitomo 170 and i-Cat(P<0.05). Conclusion: Both CBCT systems performed similarly and did not detect isthmuses in the apical third in some cases. CBCT still does not equal the performance of micro-CT in isthmus detection, but it is nonetheless a valuable tool in endodontic practice.

Assessment of the role of cone beam computed sialography in diagnosing salivary gland lesions

  • Abdel-Wahed, Nagla'a;Amer, Maha E.;Abo-Taleb, Noha Saleh Mahmoud
    • Imaging Science in Dentistry
    • /
    • 제43권1호
    • /
    • pp.17-23
    • /
    • 2013
  • Purpose: The purpose of this study was to assess cone-beam computed (CBCT) sialography imaging in the detection of different changes associated with lesions of salivary glands. Materials and Methods: This study consisted of 8 cases with signs and symptoms from salivary gland lesions. Conventional sialography using digital panoramic and lateral oblique radiographs and CBCT sialography were performed for each subject. The radiographs were evaluated by 3 radiologists independently of each other. The results were compared between conventional sialography and CBCT sialography in the evaluation of various lesions associated with the salivary glands. Results: There was an agreement between the radiologists in interpreting the lesions that affected salivary glands with both techniques. The detection of the presence of stones or filling defects, stenosis, ductal evagination, dilatation, and space occupying lesions was 83% for conventional sialography compared with CBCT sialography. CBCT sialography was superior to conventional sialography in revealing stones, stenosis, and strictures, especially in the second and third order branches. Conclusion: It would be advisable to perform CBCT sialography in cases of obstructive salivary gland diseases for better demonstration of the ductal system of the gland.