• Title/Summary/Keyword: Cone Beam Computed Tomography(CBCT)

Search Result 552, Processing Time 0.019 seconds

Clinical Applications of CBCT and 3D Digital Technology in Orthodontics (임상가를 위한 특집 1 - Digital Orthodontics를 이용한 진단과 치료 현황)

  • Park, Jae Hyun
    • The Journal of the Korean dental association
    • /
    • v.52 no.1
    • /
    • pp.8-16
    • /
    • 2014
  • The introduction of cone-beam computed tomography(CBCT) and computer software in orthodontics has allowed orthodontists to provide more accurate diagnosis and treatment. The most common use of CBCT imaging allows orthodontists to visualize the precise position of supernumerary or impacted teeth, especially impacted canines. In doing so, the exact angulation of impaction and proximity of adjacent roots can be evaluated by orthodontists, allowing them to choose vector forces for tooth movement while minimizing root resorption. Even though 2-dimensional panoramic images can be used to view the position of the impacted canines, they have limitations because it is not possible to evaluate the impacted tooth position 3-dimensionally. An accurate knowledge of root position improves the determination of success in orthodontic treatment. Nowadays, considering the fast pace of technological development, a combination of intraoral scanning, digital setups, custommade brackets and wires, and indirect bonding may soon become the orthodontic standard. In this paper, this will be discussed along with the digital models.

Endodontic management of a C-shaped maxillary first molar with three independent buccal root canals by using cone-beam computed tomography

  • Karanxha, Lorena;Kim, Hee-Jin;Hong, Sung-Ok;Lee, Wan;Kim, Pyung-Sik;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.175-179
    • /
    • 2012
  • The aim of this study was to present a method for endodontic management of a maxillary first molar with unusual C-shaped morphology of the buccal root verified by cone-beam computed tomography (CBCT) images. This rare anatomical variation was confirmed using CBCT, and nonsurgical endodontic treatment was performed by meticulous evaluation of the pulpal floor. Posttreatment image revealed 3 independent canals in the buccal root obturated efficiently to the accepted lengths in all 3 canals. Our study describes a unique C-shaped variation of the root canal system in a maxillary first molar, involving the 3 buccal canals. In addition, our study highlights the usefulness of CBCT imaging for accurate diagnosis and management of this unusual canal morphology.

Normal range of facial asymmetry in spherical coordinates: a CBCT study

  • Yoon, Suk-Ja;Wang, Rui-Feng;Na, Hee Ja;Palomo, Juan Martin
    • Imaging Science in Dentistry
    • /
    • v.43 no.1
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: This study aimed to measure the bilateral differences of facial lines in spherical coordinates from faces within a normal range of asymmetry utilizing cone-beam computed tomography (CBCT). Materials and Methods: CBCT scans from 22 females with normal symmetric-looking faces (mean age 24 years and 8 months) were selected for the study. The average menton deviation was $1.01{\pm}0.66$ mm. The spherical coordinates, length, and midsagittal and coronal inclination angles of the ramal and mandibular lines were calculated from CBCT. The bilateral differences in the facial lines were determined. Results: All of the study subjects had minimal bilateral differences of facial lines. The normal range of facial asymmetry of the ramal and mandibular lines was obtained in spherical coordinates. Conclusion: The normal range of facial asymmetry in the spherical coordinate system in this study should be useful as a reference for diagnosing facial asymmetry.

Risk factors for external root resorption of maxillary second molars associated with third molars

  • Choi, Jinwoo
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • Purpose: This study aimed to evaluate the diagnostic performance of panoramic images compared to cone-beam computed tomography (CBCT) imaging for maxillary third molar (M3)-associated external root resorption (ERR), and to identify the risk factors of ERR on panoramic images. Materials and Methods: The study population was composed of all patients who underwent panoramic imaging at Dankook University Dental Hospital from May to October 2019. In total, 397 cases of maxillary M3s in 247 patients(147 men and 100 women) were included. The diagnostic accuracy of ERR in panoramic images compared to CBCT images was evaluated using the chi-square test. To identify risk factors for ERR, dental records and panoramic findings were evaluated by logistic regression analysis. Results: The diagnostic accuracy of ERR on panoramic images was 0.79 compared to CBCT images (P<0.05). Superimposition of M3s onto second molars (M2) was associated with an approximately 33 times higher risk of ERR than separated M3s(P<0.05). Impacted M3s showed a 5 times higher risk of ERR than erupted M3s(P<0.05). Conclusion: ERR related to M3s is a common clinical condition, and superimposition of M3 onto M2 on panoramic images was the most important risk factor for ERR. It seemed that CBCT examinations for maxillary M3s might be indicated for ERR diagnosis especially if panoramic radiographs show superimposition of M3 onto M2. Impaction itself was also a risk factor, and it should be carefully examined.

Follow-up Study of Condylar Bone Changes using Cone Beam Computed Tomography in Patients with Osteoarthritis (측두하악장애 골관절염 환자에서 cone-beam CT를 이용한 관절면의 변화 추적 연구)

  • Ko, Chul-Hee;Kim, Byeong-Soo;Ko, Myung-Yun;Jeong, Sung-Hee;Ok, Soo-Min;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.1
    • /
    • pp.33-45
    • /
    • 2012
  • This study was designed to assess follow-up study of condylar bone changes using cone beam computed tomography in patients with osteoarthritis. The author performed clinical examination for osteoarthritis patients who visited Orofacial Pain Clinic, Department of Oral Medicine, Pusan National University Hospital. CBCT(Cone beam computed tomography) was taken for 228 joints in 114 subjects. After average 10 months, CBCT was retaken. A Oral medicine and Oral radiologist evaluated CBCT each other. Condyle bone changes were classified by no bone change, flattening, erosion, osteophyte and sclerosis. The obtained results were as follow. 1. The condylar bone changes of osteoarthritis in temporomandibular disorder were as follow: 1) The transitions of each types of condylar bone changes was maintained at the initial state of the majority. 2) The transition of erosion was distributed erosion, flattening, sclreosis, osteohyte in order. 3) The transition of flattening was distributed flattening, osteohyte, normal, sclreosis in order. 4) The transition of osteohyte was distributed osteohyte, erosion, sclreosis, flattening in order. 5) The transition of sclreosis was distributed sclreosis, osteohyte, erosion, normal in order. 2. The signs and symptoms according to transition of each types of condylar bone changes were as follow 1) In the transition of condylar bone changes from erosin to erosion, pain, noise, LOM and MCO had symptomatic improvement. In the transition of condylar bone changes from erosin to flattening, pain, LOM, MCO had symptomatic improvement. In the transition of condylar bone changes from erosin to no bony change, pain, noise, LOM had symptomatic improvement. In the transition of condylar bone changes from erosion to flattening than the maintenance of eosion, MCO had symptomatic improvement. 2) In the transition of condylar bone changes from flattening to flattening, pain, noise and MCO had symptomatic improvement. In the transition of condylar bone changes from flattening to sclerosis, LOM had symptomatic improvement. 3) In the transition of condylar bone changes from osteophyte to osteophyte, pain, LOM and MCO had symptomatic improvement.

POSITIONAL RELATIONSHIP OF THE MANDIBULAR CANAL AND IMPACTED THIRD MOLARS BY USING DENTAL CONE BEAM COMPUTED TOMOGRAPHY (제3대구치와 하악관과의 위치 관계에서 치과용 Cone beam CT의 유용성)

  • Chu, Yeon-Gyu;Park, Young-In;Kim, Jin-Wook;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.492-498
    • /
    • 2009
  • We sought to evaluate the relationship between the mandibular canal and impacted mandibular third molars by using dental cone beam computed tomograph(CBCT) for third molar surgery. A total of 111 patients(177 teeth) offered the images through CBCT and panoramic radiography for the extraction of the mandibular third molars. In CBCT, the accurate relationship between the third molar and the mandibular canal were evaluated. In panoramic radiographies, we evaluated the impacted level and superimposition sign of the mandibular third molar with the mandibular canal, and also, the radiopacity of the white line in the canal. Data were statistically analyzed and estimated by $X^2$-test. In CBCT finding, high prevalence of contact between the mandibular canal and roots occured in the deep impacted third molars, narrowing mandibular canals, bending mandibular canals and cases where the radiopacity of white line of canals were "absence" on panoramic images. It showed statistical significance (P<0.05). When evaluating the mandibular canal and the roots through the panoramic radiography for third molar extraction, it could be difficult to diagnosis accurately. Thus, it is required to have an accurate diagnostic approach through CBCT that could evaluated the location between mandibular canal and root.

Mandibular canal branches supplying the mandibular third molar observed on cone beam computed tomographic images: Reports of four cases (콘빔형 전단화단층영상에서 관찰되는 하악관 분지 4 증례)

  • Lee, Jae-Seo;Yoon, Suk-Ja;Kang, Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.39 no.4
    • /
    • pp.209-212
    • /
    • 2009
  • Bifid mandibular canal can be an anatomic variation. This condition can lead to complication when performing mandibular anesthesia or during extraction of lower third molar, placement of implants and surgery in the mandible. Four patients underwent preoperative imaging for extraction of third molars using CBCT (CB Mercuray, Hitachi, Japan). The axial images were processed with CBworks program 2.1 (CyberMed Inc., Seoul, Korea). The branches for supplying the lower third molar were identified mainly on cross-sectional and panoramic images of CBCT. Since the location and configuration of mandibular canal variations are important in any mandibular surgical procedures, we report 4 cases of bifid mandibular canal with panoramic and the CBCT images.

  • PDF

Condylar jugular diverticulum: A report of 3 cases

  • Jagtap, Rohan;Wazzan, Taggreed;Hansen, Matthew;Kashtwari, Deeba
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.251-256
    • /
    • 2019
  • Jugular bulb diverticulum is an irregular extension of the jugular bulb into the temporal bone that may be symptomatic or asymptomatic. The jugular bulb has rarely been reported to extend into the occipital condyle; such extension is termed a condylar jugular diverticulum and is characterized as a defect in the occipital condyle contiguous with the jugular bulb. This report details 3 cases of condylar jugular diverticulum. Extension of the jugular bulb into the ipsilateral occipital condyle was noted as an incidental finding on cone-beam computed tomographic (CBCT) images of 3 patients. All 3 patients were asymptomatic, and this finding was unrelated to the initial area of interest. CBCT use is becoming ubiquitous in dentistry, as it allows 3-dimensional evaluation, unlike conventional radiography. Proper interpretation of the entire CBCT is essential, and recognition of the indicators of condylar jugular diverticulum may prevent misdiagnosis of this rare entity.

Cone-beam computed tomography of mandibular foramen and lingula for mandibular anesthesia

  • Ahn, Byeong-Seob;Oh, Song Hee;Heo, Chong-Kwan;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.125-132
    • /
    • 2020
  • Purpose: The positions of the mandibular foramen (MnF) and the lingula affect the success rate of inferior alveolar nerve block. The objective of this study was to investigate aspects of the MnF and the lingula relevant for mandibular block anesthesia using cone-beam computed tomography (CBCT). Materials and Methods: Fifty CBCT scans were collected from a picture archiving and communications system. All scans were taken using an Alphard Vega 3030 (Asahi Roentgen Co. Ltd., Kyoto, Japan). Fifty-eight MnFs of 30 subjects were included in the study. The position of the MnF, the size of the MnF, the position of the lingula, the size of the lingula, and the shape of the lingula were measured and recorded. All data were statistically analyzed at a significance level of P<0.05. Results: The position of MnF was 0.1 mm and 0.8 mm below the occlusal plane in males and females, respectively. The horizontal position of the MnF was slightly anterior to the center of the ramus in males and in the center in females (P<0.05). The vertical position of the MnF was lower in females than in males(P<0.05). The MnF was an oval shape with a longer anteroposterior dimension. The height of the lingula was 9.3 mm in males and 8.2 mm in females. The nodular type was the most common shape of the lingula, followed by the triangular, truncated, and assimilated types. Conclusion: CBCT provided useful information about the MnF and lingula. This information could improve the success rate of mandibular blocks.

Effects of various cone-beam computed tomography settings on the detection of recurrent caries under restorations in extracted primary teeth

  • Kamburoglu, Kivanc;Sonmez, Gul;Berktas, Zeynep Serap;Kurt, Hakan;Ozen, Dogukan
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.109-115
    • /
    • 2017
  • Purpose: The aim of this study was to assess the ex vivo diagnostic ability of 9 different cone-beam computed tomography (CBCT) settings in the detection of recurrent caries under amalgam restorations in primary teeth. Materials and Methods: Fifty-two primary teeth were used. Twenty-six teeth had dentine caries and 26 teeth did not have dentine caries. Black class II cavities were prepared and restored with amalgam. In the 26 carious teeth, recurrent caries were left under restorations. The other 26 intact teeth that did not have caries served as controls. Teeth were imaged using a $100{\times}90-mm$ field of view and a 0.2-mm voxel size with 9 different CBCT settings. Four observers assessed the images using a 5-point scale. Kappa values were calculated to assess observer agreement. CBCT settings were compared with the gold standard using a receiver operating characteristic analysis. The area under the curve (AUC) values for each setting were compared using the chi-square test, with a significance level of ${\alpha}=.05$. Results: Intraobserver kappa values ranged from 0.366 to 0.664 for observer 1, from 0.311 to 0.447 for observer 2, from 0.597 to 1.000 for observer 3, and from 0.869 to 1 for observer 4. Furthermore, interobserver kappa values among the observers ranged from 0.133 to 0.814 for the first reading and from 0.197 to 0.805 for the second reading. The highest AUC values were found for setting 5 (0.5916) and setting 3 (0.5886), and were not found to be statistically significant(P>.05). Conclusion: Variations in tube voltage and tube current did not affect the detection of recurrent caries under amalgam restorations in primary teeth.