• Title/Summary/Keyword: Cone Beam

Search Result 961, Processing Time 0.025 seconds

Alveolar bone thickness and lower incisor position in skeletal Class I and Class II malocclusions assessed with cone-beam computed tomography

  • Baysal, Asli;Ucar, Faruk Izzet;Buyuk, Suleyman Kutalmis;Ozer, Torun;Uysal, Tancan
    • The korean journal of orthodontics
    • /
    • v.43 no.3
    • /
    • pp.134-140
    • /
    • 2013
  • Objective: To evaluate lower incisor position and bony support between patients with Class II average- and high-angle malocclusions and compare with the patients presenting Class I malocclusions. Methods: CBCT records of 79 patients were divided into 2 groups according to sagittal jaw relationships: Class I and II. Each group was further divided into average- and high-angle subgroups. Six angular and 6 linear measurements were performed. Independent samples t-test, Kruskal-Wallis, and Dunn post-hoc tests were performed for statistical comparisons. Results: Labial alveolar bone thickness was significantly higher in Class I group compared to Class II group (p = 0.003). Lingual alveolar bone angle (p = 0.004), lower incisor protrusion (p = 0.007) and proclination (p = 0.046) were greatest in Class II average-angle patients. Spongious bone was thinner (p = 0.016) and root apex was closer to the labial cortex in high-angle subgroups when compared to the Class II average-angle subgroup (p = 0.004). Conclusions: Mandibular anterior bony support and lower incisor position were different between average- and high-angle Class II patients. Clinicians should be aware that the range of lower incisor movement in high-angle Class II patients is limited compared to average- angle Class II patients.

Relationship between chin deviation and the position and morphology of the mandible in individuals with a unilateral cleft lip and palate

  • Kim, Kyung-Seon;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.43 no.4
    • /
    • pp.168-177
    • /
    • 2013
  • Objective: In this study, we aimed to examine the relationship between chin deviation and the positional and morphological features of the mandible and to determine the factors that contributed to chin deviation in individuals with a unilateral cleft lip and palate (UCLP). Methods: Cone-beam computed tomography (CBCT) images of 28 adults with UCLP were analyzed in this study. Segmented three-dimensional temporomandibular fossa and mandible images were reconstructed, and angular, linear, and volumetric parameters were measured. Results: For all 28 individuals, the chin was found to deviate to the cleft side by 1.59 mm. Moreover, among these 28 individuals, only 7 showed distinct (more than 4 mm) chin deviation, which was toward the cleft side. Compared to the non-cleft side, the mandibular body length, frontal ramal inclination, and vertical position of the condyle were lower and inclination of the temporomandibular fossa was steeper on the cleft side. Furthermore, the differences in inclination of the temporomandibular fossa, mandibular body length, ramus length, and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. Conclusions: UCLP individuals show mild chin deviation to the cleft side. Statistical differences were noted in the parameters that represented positional and morphological asymmetries of the mandible and temporomandibular fossa; however, these differences were too small to indicate clinical significance.

Correlation between Radiographic Findings, Clinical Findings and Joint Sounds of Temporomandibular Joint Osteoarthritis Patients

  • Shin, Jung-Youn;Ahn, Jong-Mo
    • Journal of Oral Medicine and Pain
    • /
    • v.42 no.2
    • /
    • pp.35-43
    • /
    • 2017
  • Purpose: This study aims to evaluate the correlation between joint sounds and radiographic bone change patterns along with clinical symptoms of temporomandibular joint osteoarthritis (TMJ OA) patients. Methods: The patients for this study were over 19 years of age, diagnosed tentatively with TMJ OA. The patients were examined with temporomandibular disorders analysis test and all three radiographs, including panoramic radiography, transcranial radiography, and cone beam computed tomography (CBCT). Information of the patients' age, pain status, joint sound and mouth opening range were collected. And bone change pattern was examined by reviewing panoramic radiography, transcranial radiography and CBCT images. Results: The patients with crepitus had a higher average active mouth opening (AMO) range than patients without crepitus, and the group with bilateral crepitus had a higher average AMO range than the group with unilateral crepitus (p<0.001). And the patient with pain during mastication was increased in the group with clicking than the group without clicking, and the group with bilateral clicking showed a statistically significant increase in the patient with pain during mastication than the group with unilateral clicking (p<0.05). The analytical results of the relevance of crepitus showed a high correlation with bone change observed from each of the three radiographs. And the agreement in bone change findings from 3 groups of paired radiographs showed high agreement (p<0.001). Meanwhile, 77.2% of CBCT findings showed bone change of condyle without crepitus (p<0.001). Conclusions: This study presented significant results in the evaluation of the correlation with crepitus and bone change of TMJ OA patients from panoramic radiography or transcranial projection. However, the accurate assessment is required through CBCT for the patient with complains of persistent pain, limitation of mouth opening, and occlusal change even if the crepitus does not exist.

Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study

  • Lee, Du-Hyeong;An, Seo-Young;Hong, Min-Ho;Jeon, Kyoung-Bae;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.207-213
    • /
    • 2016
  • PURPOSE. A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS. For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (${\alpha}=.05$). RESULTS. The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION. The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance.

Adhesion improvement between metals and fluoropolymers by ion assisted reaction (이온보조반응에 의한 금속과 불소계 고분자의 접착력 증진)

  • Han, Sung;Cho, Jun-Sik;Choi, Sung-Chang;Yoon, Ki-Hyun;Koh, Seok-Keun
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.37-43
    • /
    • 2001
  • Polyvinylidenefluoride and Polytetrafluoroethylene have been irradiated by 1 keV Ar+ ion beam in an $O_2$ environment. Hydrophilic functional groups (such as -(C-O)-,-(C=O)-,-(C=O)-O- and so on) were formed on fluoropolymers. Contact angles of water to PVDF were reduced from $75^{\circ}$ to $31^{\circ}$. Re-increase of contact angle was originated from carbonization phase in case of high dose irradiation above $1{\times}10^{16} Ar^+cm^2$. Contact angles to PTFE decreased at low dose irradiation and were exaggerated to about $140^{\circ}$ due to cone type surface at high dose irradiation. Hydrophilic functional groups have played an important role on adhesion between metal and fluoropolymers by acid-base interaction and chemical bond formation. Adhesion of Pt/PVDF was enhanced by acid-base interaction because Pt is inert metal. Chemical bond formation between Cu and PTFE could enlarge the adhesion strength of Cu/PTFE.

  • PDF

Healing pattern of the mucous membrane after tooth extraction in the maxillary sinus

  • Yoo, Ji-Young;Pi, Sung-Hee;Kim, Yun-Sang;Jeong, Seong-Nyum;You, Hyung-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.1
    • /
    • pp.23-29
    • /
    • 2011
  • Purpose: To investigate the healing pattern of the mucous membrane after tooth extraction necessitated by periodontal disease in the maxillary sinus. Methods: One hundred and three patients with 119 maxillary sinuses were investigated. Before implant placement, cone-beam computed tomography (CT) scanning was performed. The causes of extraction, the time elapsed since extraction, smoking, periodontal disease in adjacent teeth, and gender were recorded. In addition, the thickness of the mucous membrane of the maxillary sinus and the height of residual alveolar bone at the extracted area were calculated from CT images. Results: The thickness of the mucous membrane in the periodontal disease group ($3.05{\pm}2.71\;mm$) was greater than that of the pulp disease group ($1.92{\pm}1.78\;mm$) and the tooth fracture group ($1.35{\pm}0.55\;mm$; P<0.05). The causes of extraction, the time elapsed since extraction, and gender had relationships with a thickening of the mucous membrane of the maxillary sinus (P<0.05). In contrast, the height of the residual alveolar bone at the extracted area, periodontal disease in adjacent teeth, and smoking did not show any relation to the thickening of the mucous membrane of the maxillary sinus. Conclusions: The present study revealed distinct differences in healing patterns according to the causes of extraction in the maxillary sinus, especially periodontal disease, which resulted in more severe thickening of the mucous membrane.

Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging (소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발)

  • Park, Jeong-Jin;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

Characterization and predictive value of volume changes of extremity and pelvis soft tissue sarcomas during radiation therapy prior to definitive wide excision

  • Gui, Chengcheng;Morris, Carol D.;Meyer, Christian F.;Levin, Adam S.;Frassica, Deborah A.;Deville, Curtiland;Terezakis, Stephanie A.
    • Radiation Oncology Journal
    • /
    • v.37 no.2
    • /
    • pp.117-126
    • /
    • 2019
  • Purpose: The purpose of this study was to characterize and evaluate the clinical significance of volume changes of soft tissue sarcomas during radiation therapy (RT), prior to definitive surgical resection. Materials and Methods: Patients with extremity or pelvis soft tissue sarcomas treated at our institution from 2013 to 2016 with RT prior to resection were identified retrospectively. Tumor volumes were measured using cone-beam computed tomography obtained daily during RT. Linear regression evaluated the linearity of volume changes. Kruskal-Wallis tests, Mann-Whitney U tests, and linear regression evaluated predictors of volume change. Logistic and Cox regression evaluated volume change as a predictor of resection margin status, histologic treatment response, and tumor recurrence. Results: Thirty-three patients were evaluated. Twenty-nine tumors were high grade. Prior to RT, median tumor volume was 189 mL (range, 7.2 to 4,885 mL). Sixteen tumors demonstrated significant linear volume changes during RT. Of these, 5 tumors increased and 11 decreased in volume. Myxoid liposarcoma (n = 5, 15%) predicted decreasing tumor volume (p = 0.0002). Sequential chemoradiation (n = 4, 12%) predicted increasing tumor volume (p = 0.008) and corresponded to longer times from diagnosis to RT (p = 0.01). Resection margins were positive in three cases. Five patients experienced local recurrence, and 7 experienced distant recurrence, at median 8.9 and 6.9 months post-resection, respectively. Volume changes did not predict resection margin status, local recurrence, or distant recurrence. Conclusion: Volume changes of pelvis and extremity soft tissue sarcomas followed linear trends during RT. Volume changes reflected histologic subtype and treatment characteristics but did not predict margin status or recurrence after resection.

Comparison of postoperative changes in the distal and proximal segments between conventional and sliding mini-plate fixation following mandibular setback

  • Kim, Seong-Sik;Kwak, Kyoung-Ho;Ko, Ching-Chang;Park, Soo-Byung;Son, Woo-Sung;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.46 no.6
    • /
    • pp.372-378
    • /
    • 2016
  • Objective: The purpose of the present study was to evaluate the postoperative three-dimensional (3D) changes in the proximal segments after mandibular setback sagittal split ramus osteotomy and to compare the changes between the conventional mini-plate fixation and semi-rigid sliding plate fixation. Methods: Cone-beam computed tomography (CBCT) images were used to evaluate the postoperative 3D changes in the proximal segments during the healing process. CBCT images were superimposed using the symphysis and the lower anterior mandible as references. Results: There were no statistically significant differences between the conventional mini-plate and semi-rigid sliding plate groups (p > 0.05). With respect to the distribution of changes greater than 2 mm in the landmarks, the right condylion, right coronoid process, and left condylion showed ratios of 55.6%, 50.0%, and 44.4%, respectively, in the semi-rigid sliding plate group; however, none of the landmarks showed ratios greater than 30% in the conventional mini-plate group. Conclusions: There were no statistically significant differences in postoperative changes in the segments between the conventional mini-plate and semi-rigid sliding plate groups. Nevertheless, while selecting the type of fixation technique, clinicians should consider that landmarks with greater than 2 mm changes were higher in the semi-rigid sliding plate group than in the conventional mini-plate group.

A STUDY ON BONE-CONTACT TO INTER-SEGMENTAL LENGTH RATIO OF RIGID FIXATION SCREWS USED IN BSSRO FOR MANDIBULAR SETBACK (하악지 시상절단술시 견고 고정 나사의 골편간/골내 길이 및 비율에 대한 연구)

  • Cho, Sung-Min;Kim, Seong-Hun;Park, Je-Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.329-334
    • /
    • 2009
  • Objective: To evaluate the ratio between bone-contact length and inter-segmental length of the rigid fixation screw used in bilateral sagittal split ramus osteotomy (BSSRO) for mandibular setback. Material and Methods: Records of 40 patients with Class III malocclusion were selected. 20 of them had BSSRO, while the other 20 had BSSRO with maxillary LeFort I osteotomy. All of the patients had three noncompressive bicortical screws inserted at the gonial angle through transcutaneous approach. Two screws were inserted antero-posteriorly above inferior alveolar nerve and one screw was inserted below. The lengths of bone-contact and that of inter-segmental part were measured using cone-beam computed tomography. Ratio between these two measured lengths was calculated. Results: Both bone-contact and inter-segmental lengths were longer in BSSRO group than in BSSRO with maxillary LeFort I osteotomy group. Ratio of bone-contact to inter-segmental length was lower in BSSRO group than in BSSRO with Lefort I group. Both bone-contact and inter-segmental lengths were longer at the antero-superior position than at the inferior position. However, their ratio showed little difference. Conclusion: This study suggest that stability of screws in BSSRO group was greater than in BSSRO with Lefort I group. Stability of screws at the antero-superior position was greater than at the inferior position. Ratio of bone-contact to inter-segmental lengths was 0.2 in average.