• 제목/요약/키워드: Cone Beam

검색결과 966건 처리시간 0.02초

In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

  • Han, Gaofeng;Li, Jing;Wang, Shuo;Liu, Yan;Wang, Xuedong;Zhou, Yanheng
    • 대한치과교정학회지
    • /
    • 제49권2호
    • /
    • pp.97-105
    • /
    • 2019
  • Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic tooth-movement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

Use of an anatomical mid-sagittal plane for 3-dimensional cephalometry: A preliminary study

  • Vernucci, Roberto Antonio;Aghazada, Huseynagha;Gardini, Kelly;Fegatelli, Danilo Alunni;Barbato, Ersilia;Galluccio, Gabriella;Silvestri, Alessandro
    • Imaging Science in Dentistry
    • /
    • 제49권2호
    • /
    • pp.159-169
    • /
    • 2019
  • Purpose: Cone-beam computed tomography (CBCT) is widely used for 3-dimensional assessments of cranio-maxillo-facial relationships, especially in patients undergoing orthognathic surgery. We have introduced, for reference in CBCT cephalometry, an anatomical mid-sagittal plane (MSP) identified by the nasion, the midpoint between the posterior clinoid processes of the sella turcica, and the basion. The MSP is an updated version of the median plane previously used at our institution for 2D posterior-anterior cephalometry. This study was conducted to test the accuracy of the CBCT measures compared to those obtained using standard posterior-anterior cephalometry. Materials and Methods: Two operators measured the inter-zygomatic distance on 15 CBCT scans using the MSP as a reference plane, and the CBCT measurements were compared with measurements made on patients' posterior-anterior cephalograms. The statistical analysis evaluated the absolute and percentage differences between the 3D and 2D measurements. Results: As demonstrated by the absolute mean difference (roughly 1 mm) and the percentage difference (less than 3%), the MSP showed good accuracy on CBCT compared to the 2D plane, especially for measurements of the left side. However, the CBCT measurements showed a high standard deviation, indicating major variability and low precision. Conclusion: The anatomical MSP can be used as a reliable reference plane for transverse measurements in 3D cephalometry in cases of symmetrical or asymmetrical malocclusion. In patients who suffer from distortions of the skull base, the identification of landmarks might be difficult and the MSP could be unreliable. Becoming familiar with the relevant software could reduce errors and improve reliability.

Influence of the anterior arch shape and root position on root angulation in the maxillary esthetic area

  • Petaibunlue, Suweera;Serichetaphongse, Pravej;Pimkhaokham, Atiphan
    • Imaging Science in Dentistry
    • /
    • 제49권2호
    • /
    • pp.123-130
    • /
    • 2019
  • Purpose: This study was conducted to characterize the relationship of the angulation between the tooth root axis and alveolar bone axis with anterior alveolar(AA) arch forms and sagittal root position (SRP) in the anterior esthetic region using cone-beam computed tomography (CBCT) images. Materials and Methods: CBCT images that met the inclusion and exclusion criteria were categorized using a recent classification of AA arch forms and a SRP classification. Then, the angulation of the root axis and the alveolar bone axis was measured using mid-sagittal CBCT images of each tooth. The relationships of the angulation with each AA arch form and SRP classification were evaluated using 1-way analysis of variance and a linear regression model. Results: Ninety-eight CBCT images were included in this study. SRP had a greater influence than the AA arch form on the angulation of the root axis and the alveolar bone axis(P<0.05). However, the combination of AA arch form and SRP was more predictive of the angulation of the root axis and the alveolar bone axis than either parameter individually. Conclusion: The angulation of the root axis and alveolar bone axis demonstrated a relationship with the AA arch form and SRP in teeth in the anterior esthetic region. The influence of SRP was greater, but the combination of both parameters was more predictive of root-to-bone angulation than either parameter individually, implying that clinicians should account for both the AA arch form and SRP when planning implant placement procedures in this region.

Determination of the optimal diabetes duration for bone regeneration experiments in an alloxan-induced diabetic rabbit calvarial defect model

  • Jeong, Sang-Hun;Jung, Bo Hyun;Yoo, Ki-Yeon;Um, Heung-Sik;Chang, Beom-Seok;Lee, Jae-Kwan;Choi, Won-Youl
    • Journal of Periodontal and Implant Science
    • /
    • 제48권6호
    • /
    • pp.383-394
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the optimal diabetes duration for bone regeneration experiments in an alloxan monohydrate (ALX)-induced diabetic rabbit calvarial defect model by evaluating the association between diabetes duration and bone healing capacity. Methods: Twenty-four New Zealand white rabbits were used. Twenty-two rabbits were injected with 100 mg/kg of ALX to induce experimental diabetes. These rabbits were divided into 4 groups, including a control group and groups with diabetes durations of 1 week (group 1), 2 weeks (group 2), and 4 weeks (group 3). Calvarial defects were created at 1, 2, and 4 weeks after ALX injection and in the control rabbits. Cone-beam computed tomography (CBCT) scanning was performed on the day of surgery and at 2 and 4 weeks after surgery. The rabbits were sacrificed 4 weeks after surgery, followed by histological and immunofluorescence analysis. Results: The diabetic state of all diabetic rabbits was well-maintained throughout the experiment. Reconstructed 3-dimensional CBCT imaging showed more rapid and prominent bone regeneration in the control group than in the experimental groups. Histological staining showed notable bone regeneration in the control group, in contrast to scarce bone formation in the experimental groups. The appearance and immunoreactivity of receptor activator of nuclear factor-kappa B and osteoprotegerin did not show notable differences among the groups. Conclusion: ALX administration at 100 mg/kg successfully induced experimental diabetes in rabbits. The effect of diabetes on bone healing was evident when the interval between diabetes induction and the intervention was ${\geq}1$ week.

Pattern of buccal and palatal bone density in the maxillary premolar region: an anatomical basis of anterior-middle superior alveolar (AMSA) anesthetic technique

  • Ahad, Abdul;Haque, Ekramul;Naaz, Sabiha;Bey, Afshan;Rahman, Sajjad Abdur
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권6호
    • /
    • pp.387-395
    • /
    • 2020
  • Background: The anterior-middle superior alveolar (AMSA) anesthetic technique has been reported to be a less traumatic alternative to several conventional nerve blocks and local infiltration for anesthesia of the maxillary teeth, their periodontium, and the palate. However, its anatomic basis remains controversial. The present study aimed to determine if the pattern of cortical and cancellous bone density in the maxillary premolar region can provide a rationale for the success of the AMSA anesthetic technique. Method: Cone-beam computed tomography scans of 66 maxillary quadrants from 34 patients (16 men and 18 women) were evaluated using a volumetric imaging software for cortical and cancellous bone densities in three interdental regions between the canine and first molar. Bone density was measured in Hounsfield units (HU) separately for the buccal cortical, palatal cortical, buccal cancellous, and palatal cancellous bones. Mean HU values were compared using the Mann-Whitney U test and one-way ANOVA with post-hoc analysis. Results: Cancellous bone density was significantly lower (P ≤ 0.001) in the palatal half than in the buccal half across all three interdental regions. However, there was no significant difference (P = 0.106) between the buccal and palatal cortical bone densities at the site of AMSA injection. No significant difference was observed between the two genders for any of the evaluated parameters. Conclusions: The palatal half of the cancellous bone had a significantly lower density than the buccal half, which could be a reason for the effective diffusion of the anesthetic solution following a palatal injection during the AMSA anesthetic technique.

Positioning errors of dental implants and their associations with adjacent structures and anatomical variations: A CBCT-based study

  • Ribas, Beatriz Ribeiro;Nascimento, Eduarda Helena Leandro;Freitas, Deborah Queiroz;Pontual, Andrea dos Anjos;Pontual, Maria Luiza dos Anjos;Perez, Danyel Elias Cruz;Ramos-Perez, Flavia Maria Moraes
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.281-290
    • /
    • 2020
  • Purpose: The objective of the present study was to evaluate the prevalence of dental implants positioning errors and their associations with adjacent structures and anatomical variations by means of cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of 207 patients (584 dental implants) were evaluated by 2 oral radiologists. The distance between the implant and the adjacent teeth/implants was measured and classified as adequate (≥1.5 mm and ≥3 mm, respectively) or inadequate. The presence of thread exposure, cortical perforation, implant dehiscence, implant penetration into adjacent structures, and anatomical variations was also recorded. The incisor canal diameter and the depth of the concavity of the submandibular fossa were measured in order to evaluate their correlations with the frequency of implant penetration in these structures. Descriptive analyses, the Fisher exact test, and Spearman correlation analysis were performed (α=0.05). Results: The overall prevalence of positioning errors was 82.9%. The most common error was the inadequate distance between the implant and the adjacent teeth/implants. The presence of anatomical variations did not significantly influence the overall prevalence of errors (P>0.05). There was a positive correlation between the diameter of the incisor canal and the frequency of implant penetration in this structure (r=0.232, P<0.05). Conclusion: There was a high prevalence of dental implant positioning errors, and positioning errors were not associated with the presence of anatomical variations. Professionals should be aware of the space available for implant placement during the preoperative planning stage.

Morphometric analysis of the inter-mastoid triangle for sex determination: Application of statistical shape analysis

  • Sobhani, Farshad;Salemi, Fatemeh;Miresmaeili, Amirfarhang;Farhadian, Maryam
    • Imaging Science in Dentistry
    • /
    • 제51권2호
    • /
    • pp.167-174
    • /
    • 2021
  • Purpose: Sex determination can be done by morphological analysis of different parts of the body. The mastoid region, with its anatomical location at the skull base, is ideal for sex identification. Statistical shape analysis provides a simultaneous comparison of geometric information on different shapes in terms of size and shape features. This study aimed to investigate the geometric morphometry of the inter-mastoid triangle as a tool for sex determination in the Iranian population. Materials and Methods: The coordinates of 5 landmarks on the mastoid process on the 80 cone-beam computed tomographic images(from individuals aged 17-70 years, 52.5% female) were registered and digitalized. The Cartesian x-y coordinates were acquired for all landmarks, and the shape information was extracted from the principal component scores of generalized Procrustes fit. The t-test was used to compare centroid size. Cross-validated discriminant analysis was used for sex determination. The significance level for all tests was set at 0.05. Results: There was a significant difference in the mastoid size and shape between males and females(P<0.05). The first 2 components of the Procrustes shape coordinates explained 91.3% of the shape variation between the sexes. The accuracy of the discriminant model for sex determination was 88.8%. Conclusion: The application of morphometric geometric techniques will significantly impact forensic studies by providing a comprehensive analysis of differences in biological forms. The results demonstrated that statistical shape analysis can be used as a powerful tool for sex determination based on a morphometric analysis of the inter-mastoid triangle.

CBCT imaging and histopathological characteristics of osteoradionecrosis and medication-related osteonecrosis of the jaw

  • Ogura, Ichiro;Minami, Yoshiyuki;Ono, Junya;Kanri, Yoriaki;Okada, Yasuo;Igarashi, Kensuke;Haga-Tsujimura, Maiko;Nakahara, Ken;Kobayashi, Eizaburo
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.73-80
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the cone-beam computed tomographic (CBCT) imaging and histopathological characteristics of osteoradionecrosis(ORN) and medication-related osteonecrosis of the jaw(MRONJ). Materials and Methods: Ten surgical specimens from segmental mandibulectomy (3 ORN and 7 MRONJ) were analyzed using CBCT. The CBCT parameters were as follows: high-resolution mode (tube voltage, 90.0 kV; tube current, 4.00 mA; rotation time, 16.8 s; field of view, 56 mm×56 mm; thickness, 0.099 mm). Histopathological characteristics were evaluated using histological slides of the surgical specimens. The Pearson chi-square test was used to compare ORN and MRONJ in terms of CBCT findings(internal texture, sequestrum, periosteal reaction and cortical perforation) and histopathological characteristics(necrotic bone, inflammatory cells, reactive bone formation, bacteria, Actinomyces, and osteoclasts). A P value less than 0.05 was considered to indicate statistical significance. Results: MRONJ showed periosteal reaction on CBCT more frequently than ORN (7 of 7 [100%] vs. 0 of 3 [0%], P<0.05). Regarding histopathological characteristics, MRONJ showed osteoclasts more frequently than ORN (6 of 7 [85.7%] vs. 0 of 3 [0%], P<0.05). Conclusion: This study evaluated the CBCT imaging and histopathological characteristics of ORN and MRONJ, and the findings suggest that CBCT could be useful for the evaluation of ORN and MRONJ.

Correlation analysis of periodontal tissue dimensions in the esthetic zone using a non-invasive digital method

  • Kim, Yun-Jeong;Park, Ji-Man;Cho, Hyun-Jae;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • 제51권2호
    • /
    • pp.88-99
    • /
    • 2021
  • Purpose: Direct intraoral scanning and superimposing methods have recently been applied to measure the dimensions of periodontal tissues. The aim of this study was to analyze various correlations between labial gingival thickness and underlying alveolar bone thickness, as well as clinical parameters among 3 tooth types (central incisors, lateral incisors, and canines) using a digital method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomography images and intraoral scanned files were obtained. Measurements of labial alveolar bone and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. Clinical parameters including the crown width/crown length ratio, keratinized gingival width, gingival scallop, and transparency of the periodontal probe through the gingival sulcus were examined. Results: Gingival thickness at the alveolar crest level was positively correlated with the thickness of the alveolar bone plate (P<0.05). The central incisors revealed a strong correlation between labial alveolar bone thickness at 1 and 2 mm, respectively, inferior to the alveolar crest and the thickness of the gingiva at the alveolar crest line (G0), whereas G0 and labial bone thickness at every level were positively correlated in the lateral incisors and canines. No significant correlations were found between clinical parameters and hard or soft tissue thickness. Conclusions: Gingival thickness at the alveolar crest level revealed a positive correlation with labial alveolar bone thickness, although this correlation at identical depth levels was not significant. Gingival thickness, at or under the alveolar crest level, was not associated with the clinical parameters of the gingival features, such as the crown form, gingival scallop, or keratinized gingival width.

Influence of CBCT metal artifact reduction on vertical radicular fracture detection

  • Oliveira, Mariana Rodrigues;Sousa, Thiago Oliveira;Caetano, Aline Ferreira;de Paiva, Rogerio Ribeiro;Valladares-Neto, Jose;Yamamoto-Silva, Fernanda Paula;Silva, Maria Alves Garcia
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.55-62
    • /
    • 2021
  • Purpose: This study evaluated the influence of a metal artifact reduction (MAR) tool in a cone-beam computed tomography (CBCT) device on the diagnosis of vertical root fractures (VRFs) in teeth with different root filling materials. Materials and Methods: Forty-five extracted human premolars were classified into three subgroups; 1) no filling; 2) gutta-percha; and 3) metallic post. CBCT images were acquired using an Orthopantomograph 300 unit with and without a MAR tool. Subsequently, the same teeth were fractured, and new CBCT scans were obtained with and without MAR. Two oral radiologists evaluated the images regarding the presence or absence of VRF. Receiver operating characteristic (ROC) curves and diagnostic tests were performed. Results: The overall area under the curve values were 0.695 for CBCT with MAR and 0.789 for CBCT without MAR. The MAR tool negatively influenced the overall diagnosis of VRFs in all tested subgroups, with lower accuracy (0.45-0.72), sensitivity (0.6-0.67), and specificity (0.23-0.8) than were found for the images without MAR. In the latter group, the accuracy, sensitivity, and specificity values were 0.68-0.77, 0.67-083, and 0.53-087, respectively. However, no significant difference was found between images with and without MAR for the no filling and gutta-percha subgroups (P>0.05). In the metallic post subgroup, CBCT showed a significant difference according to MAR use (P<0.05). Conclusion: The OP 300 MAR tool negatively influenced the detection of VRFs in teeth with no root canal filling, gutta-percha, or metallic posts. Teeth with metallic posts suffered the most from the negative impact of MAR.