• Title/Summary/Keyword: Cone Beam

Search Result 966, Processing Time 0.025 seconds

Three-dimensional evaluation of lingual split line after bilateral sagittal split osteotomy in asymmetric prognathism

  • Song, Jae Min;Kim, Yong Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.11-16
    • /
    • 2014
  • Objectives: The aim of this study was to evaluate the pattern of lingual split line when performing a bilateral sagittal split osteotomy (BSSO) for asymmetric prognathism. This was accomplished with the use of cone-beam computed tomography (CBCT) and three-dimensional (3D) software program. Materials and Methods: The study group was comprised of 40 patients (20 males and 20 females) with asymmetric prognathism, who underwent BSSO (80 splits; n=80) from January 2012 through June 2013. We observed the pattern of lingual split line using CBCT data and image analysis program. The deviated side was compared to the contralateral side in each patient. To analyze the contributing factors to the split pattern, we observed the position of the lateral cortical bone cut end and measured the thickness of the ramus that surrounds the mandibular lingula. Results: The lingual split patterns were classified into five types. The true "Hunsuck" line was 60.00% (n=48), and the bad split was 7.50% (n=6). Ramal thickness surrounding the lingual was $5.55{\pm}1.07$ mm (deviated) and $5.66{\pm}1.34$ mm (contralateral) (P =0.409). The position of the lateral cortical bone cut end was classified into three types: A, lingual; B, inferior; C, buccal. Type A comprised 66.25% (n=53), Type B comprised 22.50% (n=18), and Type C comprised 11.25% (n=9). Conclusion: In asymmetric prognathism patients, there were no differences in the ramal thickness between the deviated side and the contralateral side. Furthermore, no differences were found in the lingual split pattern. The lingual split pattern correlated with the position of the lateral cortical bone cut end. In addition, the 3D-CT reformation was a useful tool for evaluating the surgical results of BSSO of the mandible.

An evaluation of curve of Spee using cone beam computerized tomography in Korean (한국인에서 콘빔형 전산화단층영상을 이용한 스피만곡 평가)

  • Oh, Sang-Chun;Kim, Seul-Gi;Kim, Yu-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.93-101
    • /
    • 2014
  • Purpose: The aim of this study is to investigate the typical shape of the curve of Spee in Korean and analyze the curve of Spee according to gender, age, and left and right. Materials and Methods: Among the patient of Wonkwang University Sanbon Dental Hospital taking cone beam computerized tomography, the images of 500 Koreans (311 males and 189 females) who qualifies the criteria of this study were selected and their curve of Spee were analysed in sagittal plane. Results: The mean radius of curve of Spee in Korean was 91.4 mm. There was statistically significant difference between male (94.6 mm) and female (86.1 mm) by gender, but not significant differences by age and between right and left side. Conclusion: Within the limitation of this study, the smaller radius (91.4 mm) of Korean than the 4-inch (101.6 mm) value advocated by Monson was meaned that it would be need to reconsider the application of the curve of Spee in all cases when occlusal plane is reconstructed in Korean.

Three-dimensional morphological evaluation of the hard palate in Korean adults with mild-to-moderate obstructive sleep apnea

  • Yu, Chen;Ahn, Hyo-Won;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.48 no.3
    • /
    • pp.133-142
    • /
    • 2018
  • Objective: The purpose of this study was to evaluate differences in three-dimensional (3D) morphology of the hard palate between Korean adults with and without mild-to-moderate obstructive sleep apnea (OSA) using cone-beam computed tomographic (CBCT) data. Methods: The protocol for the two-dimensional (2D) and 3D mathematical modeling was established by analyzing CBCT images of 30 adults with OSA and 30 matched controls without OSA, using MIMICS software. The linear and angular measurements were also determined using this software. The measurements were repeated for 30 palates, by the same operator, to assess reliability. Results: The palates of OSA patients were higher in the posterior part and narrower in the anterior-superior part than those of the control group (p < 0.05). The nasal cavities of patients with OSA were narrower (p < 0.05) than those of controls. The increasing angle of the first molar palatal root is a compensation of the upper dental arch to improve occlusion. However, for most palatal measurements, there were no significant differences between the OSA and control groups (p > 0.05). The results of 2D and 3D mathematical models were consistent for linear and angular measurements, indicating that 2D and 3D mathematical modeling of the palate is a reliable methodology. Conclusions: OSA is a multifactorial disease; the palates of adults with mild-to-moderate OSA do not have specific morphological features distinct from those of healthy controls.

Comparison of three midsagittal planes for three-dimensional cone beam computed tomography head reorientation

  • Lee, Eon-Hwa;Yu, Hyung-Seog;Lee, Kee-Joon;Han, Sang-Sun;Jung, Hwi-Dong;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.3-12
    • /
    • 2020
  • Objective: This study compared three prominent midsagittal planes (MSPs) to identify the MSP that best approximates the true symmetrical MSP. Methods: Forty-three patients (mean age, 23.0 ± 8.20 years) were grouped as follows: group 1 consisted of 10 patients with skeletal Class I and a menton (Me) deviation of < 2 mm; group 2, 11 patients with skeletal Class III and a Me deviation < 2 mm; group 3, nine patients with skeletal Class III and a Me deviation of 2 to less than 4 mm; and group 4, 13 patients with skeletal Class III and an Me deviation ≥ 4 mm. The candidate MSPs were established by three-dimensional (3D) cone beam computed tomography (CBCT) reorientation methods (RMs): (1) the MSP perpendicular to the Frankfort horizontal (FH) plane while passing through the crista galli and basion; (2) the MSP including the nasion, incisive foramen, and basion; (3) the MSP including the nasion, anterior nasal spine, and posterior nasal spine. The mean absolute distances (MADs) to the MSPs were calculated from the coordinates of 1,548 points on 129 CBCT images. The differences in the values of the 3D coordinates among RMs were compared. Results: The MADs of the three RMs showed significant differences (p < 0.05). Most of the differences in values of the coordinates were not significant among RMs. Conclusions: Although the differences in distance among the three MSPs were minor, the MSP perpendicular to the FH plane while passing through the crista galli and basion best approximated the true symmetrical MSP.

Evaluation of effective dose in panorama, cone beam CT and the usefulness of x-ray protective (치과방사선검사에서 방사선방어용구 사용 전, 후의 유효선량에 대한 평가)

  • Kim, Jae In;Choi, Won Keun;Lee, So La;Lee, Jung Hwa;Lee, Kwan Sub
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.15-22
    • /
    • 2012
  • The purpose of this study was to measure the absorbed dose and calculate the effective dose for cone beam computed tomography (CBCT) and panorama units and to estimate usefulness of x-ray protective. Rando phantom and glass dosimeters were used for dosimetry. The absorbed doses were measured at 15 organs and 14 remainder from correspond to ICRP 2007 recommendations. The absorbed dose was highest in salivary glands as measured CBCT 2.420mGy, panorama 0.307mGy. Absorbed dose in another organs were high in order of thyroid, brain, skin, esophagus. The effective dose was CBCT 0.100mSv, panorama 0.011mSv and effective dose of panorama was higher than that of CBCT by 10 times. In case of wearing x-ray protective, reducing effective dose of CBCT by 0.066mSv (66%) and panorama by 0.008mSv (72%). Effective dose were reduced by radiological shielding but it needs further optimization studies, where dosimetric data are analyzed in combination with image quality with keep the patients' exposure as low as possible.

  • PDF

CBCT study of mandibular first molars with a distolingual root in Koreans

  • Kim, Hee-Ho;Jo, Hyoung-Hoon;Min, Jeong-Bum;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.3
    • /
    • pp.33.1-33.8
    • /
    • 2018
  • Objectives: This study aimed to investigate the prevalence of a separate distolingual root and to measure the thickness of the buccal cortical bone in mandibular first molars in Koreans using cone-beam computed tomography (CBCT) images. Materials and Methods: High-quality CBCT data from 432 patients were analyzed in this study. The prevalence of a separate distolingual root of the mandibular first molar was investigated. The distance from the distobuccal and distolingual root apices to the outer surface of the buccal cortical bone was measured. We also evaluated the thickness of the buccal cortical bone. Results: The prevalence of a separate distolingual root (2 separate distal roots with 1 canal in each root; 2R2C) was 23.26%. In mandibular first molars with 2R2C, the distance from the distobuccal root apex to the outer surface of the buccal cortical bone was 5.51 mm. Furthermore, the distance from the distolingual root apex to the outer surface of the buccal cortical bone was 12.09 mm. In mandibular first molars with 2R2C morphology, the thickness of the buccal cortical bone at the distobuccal root apex of the mandibular first molar was 3.30 mm. The buccal cortical bone at the distobuccal root apex was significantly thicker in the right side (3.38 mm) than the left side (3.09 mm) (p < 0.05). Conclusions: A separate distolingual root is not rare in mandibular first molars in the Korean population. Anatomic and morphologic knowledge of the mandibular first molar can be useful in treatment planning, including surgical endodontic treatment.

Diagnostic methods for assessing maxillary skeletal and dental transverse deficiencies: A systematic review

  • Sawchuk, Dena;Currie, Kris;Vich, Manuel Lagravere;Palomo, Juan Martin;Flores-Mir, Carlos
    • The korean journal of orthodontics
    • /
    • v.46 no.5
    • /
    • pp.331-342
    • /
    • 2016
  • Objective: To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods: An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results: Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions: Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority.

Quantitative evaluation of midpalatal suture maturation via fractal analysis

  • Kwak, Kyoung Ho;Kim, Seong Sik;Kim, Yong-Il;Kim, Yong-Deok
    • The korean journal of orthodontics
    • /
    • v.46 no.5
    • /
    • pp.323-330
    • /
    • 2016
  • Objective: The purpose of this study was to determine whether the results of fractal analysis can be used as criteria for midpalatal suture maturation evaluation. Methods: The study included 131 subjects aged over 18 years of age (range 18.1-53.4 years) who underwent cone-beam computed tomography. Skeletonized images of the midpalatal suture were obtained via image processing software and used to calculate fractal dimensions. Correlations between maturation stage and fractal dimensions were calculated using Spearman's correlation coefficient. Optimal fractal dimension cut-off values were determined using a receiver operating characteristic curve. Results: The distribution of maturation stages of the midpalatal suture according to the cervical vertebrae maturation index was highly variable, and there was a strong negative correlation between maturation stage and fractal dimension (-0.623, p < 0.001). Fractal dimension was a statistically significant indicator of dichotomous results with regard to maturation stage (area under curve = 0.794, p < 0.001). A test in which fractal dimension was used to predict the resulting variable that splits maturation stages into ABC and D or E yielded an optimal fractal dimension cut-off value of 1.0235. Conclusions: There was a strong negative correlation between fractal dimension and midpalatal suture maturation. Fractal analysis is an objective quantitative method, and therefore we suggest that it may be useful for the evaluation of midpalatal suture maturation.

Evaluation of stability after pre-orthodontic orthognathic surgery using cone-beam computed tomography: A comparison with conventional treatment

  • Ann, Hye-Rim;Jung, Young-Soo;Lee, Kee-Joon;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.46 no.5
    • /
    • pp.301-309
    • /
    • 2016
  • Objective: The aim of this study was to evaluate the skeletal and dental changes after intraoral vertical ramus osteotomy (IVRO) with and without presurgical orthodontics by using cone-beam computed tomography (CBCT). Methods: This retrospective cohort study included 24 patients (mean age, 22.1 years) with skeletal Class III malocclusion who underwent bimaxillary surgery with IVRO. The patients were divided into the preorthodontic orthognathic surgery (POGS) group (n = 12) and conventional surgery (CS) group (n = 12). CBCT images acquired preoperatively, 1 month after surgery, and 1 year after surgery were analyzed to compare the intergroup differences in postoperative three-dimensional movements of the maxillary and mandibular landmarks and the changes in lateral cephalometric variables. Results: Baseline demographics (sex and age) were similar between the two groups (6 men and 6 women in each group). During the postsurgical period, the POGS group showed more significant upward movement of the mandible (p < 0.05) than did the CS group. Neither group showed significant transverse movement of any of the skeletal landmarks. Moreover, none of the dental and skeletal variables showed significant intergroup differences 1 year after surgery. Conclusions: Compared with CS, POGS with IVRO resulted in significantly different postsurgical skeletal movement in the mandible. Although both groups showed similar skeletal and dental outcomes at 1 year after surgery, upward movement of the mandible during the postsurgical period should be considered to ensure a more reliable outcome after POGS.

The accuracy of linear measurements of maxillary and mandibular edentulous sites in conebeam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

  • Ganguly, Rumpa;Ramesh, Aruna;Pagni, Sarah
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view ($13cm{\times}16cm$) and small field of view ($5cm{\times}8cm$) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.