• 제목/요약/키워드: Cone Beam

검색결과 966건 처리시간 0.029초

Cone-beam computed tomography in endodontics: from the specific technical considerations of acquisition parameters and interpretation to advanced clinical applications

  • Nestor Rios-Osorio;Sara Quijano-Guauque;Sandra Brinez-Rodriguez;Gustavo Velasco-Flechas;Antonieta Munoz-Solis;Carlos Chavez;Rafael Fernandez-Grisales
    • Restorative Dentistry and Endodontics
    • /
    • 제49권1호
    • /
    • pp.1.1-1.18
    • /
    • 2024
  • The implementation of imaging methods that enable sensitive and specific observation of anatomical structures has been a constant in the evolution of endodontic therapy. Cone-beam computed tomography (CBCT) enables 3-dimensional (3D) spatial anatomical navigation in the 3 volumetric planes (sagittal, coronal and axial) which translates into great accuracy for the identification of endodontic pathologies/conditions. CBCT interpretation consists of 2 main components: (i) the generation of specific tasks of the image and (ii) the subsequent interpretation report. A systematic and reproducible method to review CBCT scans can improve the accuracy of the interpretation process, translating into greater precision in terms of diagnosis and planning of endodontic clinical procedures. MEDLINE (PubMed), Web of Science, Google Scholar, Embase and Scopus were searched from inception to March 2023. This narrative review addresses the theoretical concepts, elements of interpretation and applications of the CBCT scan in endodontics. In addition, the contents and rationale for reporting 3D endodontic imaging are discussed.

Usefulness of Mobile Computed Tomography in Patients with Coronavirus Disease 2019 Pneumonia: A Case Series

  • Ji Young Rho;Kwon-Ha Yoon;Sooyeon Jeong;Jae-Hoon Lee;Chul Park;Hye-Won Kim
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.1018-1023
    • /
    • 2020
  • The coronavirus disease (COVID-19) outbreak has reached global pandemic status as announced by the World Health Organization, which currently recommends reverse transcription polymerase chain reaction (RT-PCR) as the standard diagnostic tool. However, although the RT-PCR test results may be found negative, there are cases that are found positive for COVID-19 pneumonia on computed tomography (CT) scan. CT is also useful in assessing the severity of COVID-19 pneumonia. When clinicians desire a CT scan of a patient with COVID-19 to monitor treatment response, a safe method for patient transport is necessary. To address the engagement of medical resources necessary to transport a patient with COVID-19, our institution has implemented the use of mobile CT. Therefore, we report two cases of COVID-19 pneumonia evaluated by using mobile cone-beam CT. Although mobile cone-beam CT had some limitations regarding its image quality such as scatter noise, motion and streak artifacts, and limited field of view compared with conventional multi-detector CT, both cases had acceptable image quality to establish the diagnosis of COVID-19 pneumonia. We report the usefulness of mobile cone-beam CT in patients with COVID-19 pneumonia.

Application of Cone-Beam Computed Tomography-Generated Cephalograms in Children and Adolescents

  • Wooju So;Ji Min Kim;Bumhee Park;Yon-joo Mah
    • 대한소아치과학회지
    • /
    • 제51권3호
    • /
    • pp.265-278
    • /
    • 2024
  • This study investigates the potential of cone-beam computed tomography (CBCT)-generated cephalograms as a replacement for conventional lateral cephalograms (LCs) in children and adolescents. This retrospective study included 60 individuals, equally divided into permanent and mixed dentition groups. Both groups underwent conventional LCs and CBCT scans on the same day. LCs were then derived from CBCT scans. The same examiner performed digital measurements twice, with a week's interval, identifying landmarks and obtaining 7 angular and 5 linear measurements. In the permanent dentition group, significant differences were observed between the two imaging modalities for 6 angular and 2 linear measurements. In the mixed dentition group, significant differences were observed for 3 angular and 2 linear measurements. However, none of these differences exceeded the clinically acceptable limit of 2.0° or 2.0 mm. No significant differences in any measurement were found between the two groups (p < 0.05). CBCT-generated LCs demonstrated comparable results with good reliability in both dentition groups, suggesting their potential as suitable alternatives for children and adolescents who require CBCT for clinical purposes.

시간단축 알고리즘을 통한 3D 동영상 구현 (Implementation of 3D Video using Time-Shortening Algorithm)

  • 신진섭;정찬웅
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권6호
    • /
    • pp.123-128
    • /
    • 2020
  • 본 논문에서는 3차원 동영상을 구현하기 위하여 인체에 유해한 방사능 피폭량이 부챗살 형태의 Fan Beam 보다 상대적으로 적은 원추형 Cone Beam CT 시스템을 설계하였다. 설계된 시스템은 X-ray가 조사된 각도에서 획득한 데이터를 영상처리부로 전송하고 영상을 구성하는 계산 속도를 빠르게 하기 위하여 초월함수가 보다 적은 3단계 회전 행렬을 이용하여 3차원 영상을 구현하는 회전 기반법을 사용하였다. 본 연구에서는 3차원 영상을 구성하는 시간단축을 통해 초당 3~5장의 영상을 얻음으로써 3차원 동영상을 실시간으로 구현하였으며 기존의 데이터 적층 방법에 비해 본 논문에서 사용한 회전 기반법이 우수함을 증명하였으며 단점 및 해결방법 제시하였다.

Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: An integrative review

  • Terrabuio, Bianca Rodrigues;Carvalho, Caroline Gomes;Peralta-Mamani, Mariela;da Silva Santos, Paulo Sergio;Rubira-Bullen, Izabel Regina Fischer;Rubira, Cassia Maria Fischer
    • Imaging Science in Dentistry
    • /
    • 제51권2호
    • /
    • pp.93-106
    • /
    • 2021
  • Purpose: This study was conducted to review the literature regarding the types of cone-beam computed tomography (CBCT) artifacts around dental implants and the factors that influence their formation. Materials and Methods: A search strategy was carried out in the PubMed, Embase, and Scopus databases to identify published between 2010 and 2020, and 9 studies were selected. The implants included 306 titanium, titanium-zirconium, and zirconia implants, as well as 5 titanium cylinders. Results: The artifacts around the implants were the beam-hardening artifact, the streaking artifact, and band-like radiolucent areas. Some factors that influenced the formation of artifacts were the implant material, bone type, evaluated regions, distance, type of CBCT, field of view (FOV) size, milliamperage, peak kilovoltage (kVp), and voxel size. The beam-hardening artifact was the most widely reported, and it was minimized in protocols with a smaller FOV, larger voxels, and higher kVp. Conclusion: The risk and benefit of these protocols in individuals with dental implants must be considered, and clinical examinations and complementary radiographs play an essential role in implantology.

Cone Beam CT를 이용한 하악 제 1대구치 맹출 양상에 관한 연구 (ERUPTION PATTERN OF THE MANDIBULAR FIRST MOLAR USING THE CONE BEAM CT)

  • 신정근;김재곤;백병주;양연미;정진우
    • 대한소아치과학회지
    • /
    • 제36권3호
    • /
    • pp.325-336
    • /
    • 2009
  • 건강한 정상 교합 어린이 83명(남자 42명, 여자 41명)을 대상으로 보호자 동의하에 cone beam CT 영상을 촬영하여, 하악 제 1대구치의 맹출 양상을 연구하였다. 대상을 발육 정도에 따라 Nolla stage(4-10단계)로 구분한 후 삼차원 기준 평면인 전두면(frontal), 시상면(sagittal), 수평면(horizontal)에서 각각 하악 제 1대구치의 맹출 양상을 관찰하였다. 1. 전두면과 수평면에서, 하악 제 1대구치간 폭경은 감소하였는데, stage 5에서 stage 8까지 가장 크게 감소했다가 약간 증가하였다. 2. 시상면과 전두면에서, 하악 제 1대구치 맹출량은 교합평면을 기준으로 stage 5에서 stage 7까지 가장 많은 맹출 이동을 보였다. 3. 수평면과 시상면에서, 하악 제 1대구치는 제 2유구치 원심면으로부터 stage 4에서 stage 6까지 원심으로 이동하였고 이후 큰 변화가 없었다. 4. 시상면에서, 교합 평면과 하악 제 1대구치의 근원심 치축이 이루는 각은 stage 4에서 stage 8까지 증가하였다. 5. 전두면에서, 교합 평면과 하악 제 1대구치의 협설측 치축이 이루는 각은 지속적으로 증가하였다. 6. 수평면에서, 정중 시상면과 하악 제 1대구치의 치축이 이루는 각은 stage 5부터 stage 8까지 증가하다 stage 8이후에는 다시 약간 감소하였다.

  • PDF

측두하악관절 골관절염 환자의 진단에서 Cone Beam 전산화 단층촬영의 유용성 (The Usefulness of Cone Beam Computed Tomography in Diagnosis of Temporomandibular Joint Osteoarthritis)

  • 노창세;정연화;태일호;고명연;안용우
    • Journal of Oral Medicine and Pain
    • /
    • 제34권1호
    • /
    • pp.81-90
    • /
    • 2009
  • 2005년부터 2007년까지 진주 OOO치과의원 턱관절/구강안면통증클리닉에 내원한 측두하악장애환자 95명, 190개의 관절을 대상으로 한 명의 검사자가 측두하악관절장애 분석검사와 파노라마영상검사를 엄격히 시행하고, CBCT영상을 촬영하여 구강내과 전문의와 치과방사선과 전문의가 각각 영상진단 하였으며, 임상적 진단과 CBCT영상의 결과를 비교하여 다음과 같은 결과를 얻었다. 1. 구강내과 전문의와 치과방사선과 전문의에 의한 CBCT의 영상진단의 일치도(Kappa: 0.681)가 높았다. 2. 파노라마영상과 CBCT의 영상진단과의 일치도(Kappa: 0.169)가 낮으며, 파노라마영상에서 골변화의 위음성이 높았다. 3. 임상적으로 비퇴행성골관절염으로 진단된 관절 중 CBCT의재진단시 54.2%에서 골변화가 관찰되었으며, 퇴행성골관절염으로 진단된 관절 중 CBCT의 재진단시 15.3%에서 골변화가 없는 것으로 관찰되었다. 4. 관절통은 침식성 골변화에서 높게 나타났으며, 골증식체의 골변화에서 염발음이 가장 많이 나타났으며 병력기간도 가장 길었다.

Cone-beam CT를 이용한 골격성 III급 부정교합자의 하악골 후퇴술 후 상기도 변화에 관한 연구 (Three dimensional cone-beam CT study of upper airway change after mandibular setback surgery for skeletal Class III malocclusion patients)

  • 김나리;김용일;박수병;황대석
    • 대한치과교정학회지
    • /
    • 제40권3호
    • /
    • pp.145-155
    • /
    • 2010
  • 악교정 수술은 안면골격형태 뿐만 아니라 상기도 공간에도 영향을 준다. 본 연구는 골격성 III급 부정교합자 중 하악골 후퇴술을 시행 받은 환자를 대상으로 상기도 공간의 부피변화를 관찰하기 위하여 시행되었다. 기존의 연구들이 측모두부방사선사진을 중심으로 시행하였으나 본 연구에서는 3차원 cone-beam computed tomography (CBCT)를 이용하여 영상을 재구성한 뒤 분석하였다. 연구 대상은 하악골 후퇴술을 시행 받은 20명(남성 12, 여성 8)이었으며, 수술 전 평균 1.8주(Baseline), 술 후 평균 2.3개월(T1) 그리고 술 후 평균 1년(T2) 시기에 CBCT를 촬영하였다. 상기도공간은 기준평면에 따라 비인두, 구인두, 하인두로 나누어 계측하고 Baseline, T1, T2를 각각 비교하였다. 결과로 수술 후 2.3개월(T1)시기에 상기도 공간은 상당히 감소하였으며 (p < 0.001), 술 후 1년 후(T2)에도 감소된 양은 증가하지 않았다. 구인두는 상기도 공간 중 가장 많은 감소폭을 보였다. 이러한 결과로 하악골후퇴술은 상기도 공간을 장 단기간동안 감소하는 것으로 나타났다.

Cone beam CT를 이용한 안면골격형태에 따른 상기도 공간 분석 (Pharyngeal airway analysis of different craniofacial morphology using cone-beam computed tomography (CBCT))

  • 김용일;김성식;손우성;박수병
    • 대한치과교정학회지
    • /
    • 제39권3호
    • /
    • pp.136-145
    • /
    • 2009
  • 상기도 공간은 3차원 입체 구조물로서 두부규격방사선사진 등으로 분석하기에는 평가의 한계가 존재하였다. 본 연구는 최근 방사선 피폭량 등의 감소로 그 활용도가 높아진 cone beam CT (CBCT)를 이용하여 안면골격형태에 따른 상기도 공간의 면적, 전후방 폭경 및 측방 폭경을 측정하고 그 관련성을 알아보았다. 102명을 대상으로 CBCT (VCT, Vatech, Seoul, Korea)를 촬영하였으며, FH plane에 평행하면서 aa point (the most anterior point on the anterior arch of atlas), $CV_{2ia}$, $CV_{3ia}$ point (most infero-anterior point on the body of the second & third cervical vertebra)를 지나는 평면을 기준으로 설정하였다. 각 항목의 계측치는 one-way ANOVA를 이용하여 통계처리하고 Duncan test로 사후검정하였다. 연구 결과, 안면 골격형태에 따른 측방 폭경에는 유의한 차이가 없었다. Group 2 (Class II) 집단은 aa plane, $CV_2$ plane, $CV_3$ plane에 의해 형성된 상기도 공간의 단면적이 좁았으며, 전후방 폭경도 Group 3 (Class III)에 비해 유의성 있게 좁았다. 수직 안면골격형태와 정상 안면골격 형태간의 유의성 있는 차이는 없었으나, aa plane에서 형성된 상기도 공간의 전후방 폭경은 Group 1V (Class I vertical)가 Group 1N (Class I normal)에 비해 유의성 있게 좁은 것으로 나타났다 (p < 0.05).

Cone-beam computed tomography를 이용한 미맹출 영구치의 계측 (ACCURACY OF CONE-BEAM COMPUTED TOMOGRAPHY IN PREDICTING THE DIAMETER OF UNERUPTED TEETH)

  • 김성희;김영종;김신;정태성
    • 대한소아치과학회지
    • /
    • 제39권2호
    • /
    • pp.139-144
    • /
    • 2012
  • 본 연구는 CBCT(Cone-beam computed tomography)영상에서 미맹출 치아 크기 측정의 재현성과 정확성을 평가하기 위해 시행되었다. 매복치를 주소로 부산대학교 치과병원 소아치과에 내원한 혼합치열기 환자 중 진단 목적으로 CBCT 채득에 동의한 환자의 미맹출 견치 및 소구치 69개를 대상으로 하였다. CBCT 영상에서 측정한 미맹출 치아의 최대 근원심 폭경 계측치와 동일한 치아가 구강 내로 완전히 맹출한 후 채득한 석고 모형에서 대상 치아를 digital caliper로 측정한 최대 근원심 폭경 계측치를 비교하여 다음과 같은 결론을 얻었다. 1. CBCT 영상에서 미맹출 치아를 계측하는 방법은 재현성이 높다(ICC=0.91). 2. CBCT 영상에서 측정한 미맹출 치아의 최대 근원심 폭경 계측치와 석고 모형에서 측정한 대상 치아의 최대 근원심 폭경 계측치는 높은 상관 관계가 있었다(r=0.91). 3. CBCT 영상에서 측정한 미맹출 치아 최대 근원심 폭경 계측치와 석고 모형에서 측정한 대상 치아의 최대 근원심 폭경 계측치는 통계적으로 유의한 차이가 있었다($p$ <0.05). CBCT 영상에서 측정한 미맹출 치아 최대 근원심 폭경의 계측치가 석고 모형에서 측정한 대상 치아의 최대 근원심 폭경 계측치보다 평균 0.2 mm 작게 측정되었다. 그러나 이러한 차이는 임상적으로 수용 가능한 수준이라 생각된다.