• Title/Summary/Keyword: Cone Angle

Search Result 380, Processing Time 0.022 seconds

Implementation of 3D Video using Time-Shortening Algorithm (시간단축 알고리즘을 통한 3D 동영상 구현)

  • Shin, Jin-Seob;Jeong, Chan-Woong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.123-128
    • /
    • 2020
  • In this paper, we presents a new cone beam computerized tomography (CBCT) system for the reconstruction of 3 dimensional dynamic images. The system using cone beam has less the exposure of radioactivity than fan beam, relatively. In the system, the reconstruction 3-D image is reconstructed with the radiation angle of X-ray in the image processing unit and transmitted to the monitor. And in the image processing unit, the Three Pass Shear Matrices, a kind of Rotation-based method, is applied to reconstruct 3D image because it has less transcendental functions than the one-pass shear matrix to decrease a time of calculations for the reconstruction 3-D image in the processor. The new system is able to get 3~5 3-D images a second, reconstruct the 3-D dynamic images in real time. And we showed the Rotation-based method was good rather than existing reconstruction technique for 3D images, also found weakness and a solution for it.

Comparison of data mining algorithms for sex determination based on mastoid process measurements using cone-beam computed tomography

  • Farhadian, Maryam;Salemi, Fatemeh;Shokri, Abbas;Safi, Yaser;Rahimpanah, Shahin
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.323-330
    • /
    • 2020
  • Purpose: The mastoid region is ideal for studying sexual dimorphism due to its anatomical position at the base of the skull. This study aimed to determine sex in the Iranian population based on measurements of the mastoid process using different data mining algorithms. Materials and Methods: This retrospective study was conducted on 190 3-dimensional cone-beam computed tomographic (CBCT) images of 105 women and 85 men between the ages of 18 and 70 years. On each CBCT scan, the following 9 landmarks were measured: the distance between the porion and the mastoidale; the mastoid length, height, and width; the distance between the mastoidale and the mastoid incision; the intermastoid distance (IMD); the distance between the lowest point of the mastoid triangle and the most prominent convex surface of the mastoid (MF); the distance between the most prominent convex mastoid point (IMSLD); and the intersecting angle drawn from the most prominent right and left mastoid point (MMCA). Several predictive models were constructed and their accuracy was compared using cross-validation. Results: The results of the t-test revealed a statistically significant difference between the sexes in all variables except MF and MMCA. The random forest model, with an accuracy of 97.0%, had the best performance in predicting sex. The IMSLD and IMD made the largest contributions to predicting sex, while the MMCA variable had the least significant role. Conclusion: These results show the possibility of developing an accurate tool using data mining algorithms for sex determination in the forensic framework.

Evaluation of mandibular buccal shelf characteristics in the Colombian population: A cone-beam computed tomography study

  • Escobar-Correa, Natalia;Ramirez-Bustamante, Maria Antonia;Sanchez-Uribe, Luis Alejandro;Upegui-Zea, Juan Carlos;Vergara-Villarreal, Patricia;Ramirez-Ossa, Diana Milena
    • The korean journal of orthodontics
    • /
    • v.51 no.1
    • /
    • pp.23-31
    • /
    • 2021
  • Objective: To evaluate the mandibular buccal shelf (MBS) in terms of the angulation and bone depth and thickness according to sex, age, and sagittal and vertical skeletal patterns in a Colombian population using cone-beam computed tomography (CBCT). Accordingly, the optimal site for miniscrew insertion in this area was determined. Methods: This descriptive, retrospective study included 64 hemi-arches of 34 patients. On CBCT images, the angulation, buccal bone depth (4 and 6 mm from the cementoenamel junction [CEJ] of MBS), and buccal bone thickness (6 and 11 mm from the CEJ of MBS) were measured at the mesial and distal roots of the mandibular first and second molars. Results: There were no statistically significant differences in the angulation, depth, and thickness of MBS between male and female patients. The values for the bone around the distal root of the mandibular second molar were significantly greater than the other values. The osseous characteristics were significantly better in participants aged 16-24 years. Class III patients exhibited the best osseous characteristics, with the bone depth at 6 mm being significantly different from that in Class I and Class II patients. Although values tended to be greater in patients with low angles, the difference was not statistically significant. Conclusions: MBS provides an optimal bone surface for miniscrew insertion, with better osseous characteristics at the distal root of the mandibular second molar, 4 mm from CEJ. Adolescent patients, Class III patients, and patients with a low angle exhibit the most favorable osseous characteristics in the MBS area.

Relationship of the maxillary posterior teeth and maxillary sinus floor in different skeletal growth patterns: A cone-beam computed tomographic study of 1600 roots

  • Shrestha, Biken;Shrestha, Rachana;Lu, Hongfei;Mai, Zhihui;Chen, Lin;Chen, Zheng;Ai, Hong
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.19-25
    • /
    • 2022
  • Purpose: This study evaluated the distance from the posterior root apices to the maxillary sinus floor (MSF) and the frequency of roots touching or protruding through the MSF using cone-beam computed tomography (CBCT). Materials and Methods: This study included 100 subjects divided into different vertical and anteroposterior skeletal growth patterns. On CBCT images, the distance from the posterior root apices to MSF was measured and the frequency of roots touching or protruding through the MSF was evaluated using NNT software (version 5.3.0.0; ImageWorks, Elmsford, NY, USA). Results: No statistically significant differences were found in the distance from the posterior root apices to the MSF among vertical skeletal groups (P>0.05). The palatal roots of the first molar and the palatal, mesio-buccal and disto-buccal roots of the second molars had significantly less distance from MSF in skeletal class II than in class III (P<0.05). The high-angle group had the highest frequencies of roots touching or protruding into the maxillary sinus (49.8%); the lowest proportion of these roots was found in skeletal class III (28.3%) and the highest proportion in class II (50.3%). Males had shorter distances from the posterior root apices to the MSF and higher frequencies of roots protruding through or touching the MSF than females. Conclusion: Anteroposterior skeletal growth patterns and sex affected the distances from the maxillary posterior roots to the MSF. The frequency of roots protruding into or touching the sinus was affected by both vertical and anteroposterior skeletal groups and sex. These findings have implications for dental practice.

Controlled Surface Functionalities of metals using Femtosecond Laser-induced Nano- and Micro-scale Surface Structures (펨토초 레이저 유도 나노 및 마이크로 구조물을 활용한 금속 표면 기능성 제어)

  • Taehoon Park;Hyo Soo Lee;Hai Joong Lee;Taek Yong Hwang
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.55-61
    • /
    • 2023
  • With femtosecond (fs) laser pulse irradiation on metals, various types of nano- and micro-scale structures can be naturally induced at the surface through laser-matter interaction. Two notable structures are laser-induced periodic surface structures (LIPSSs) and cone/spike structures, which are known to significantly modify the optical and physical properties of metal surfaces. In this work, we irradiate fs laser pulses onto various types of metals, cold-rolled steel, pickled & oiled steel, Fe-18Cr-8Ni alloy, Zn-Mg-Al alloy coated steel, and pure Cu which can be useful for precise molding and imprinting processes, and adjust the morphological profiles of LIPSSs and cone/spike structures for clear structural coloration and a larger range of surface wettability control, respectively, by changing the fluence of laser and the speed of raster scan. The periods of LIPSSs on metals used in our experiments are nearly independent of laser fluence. Accordingly, the structural coloration of the surface with LIPSSs can be optimized with the morphological profile of LIPSSs, controlled only by the speed of the raster scan once the laser fluence is determined for each metal sample. However, different from LIPSSs, we demonstrate that the morphological profiles of the cone/spike structures, including their size, shape, and density, can be manipulated with both the laser fluence and the raster scan speed to increase a change in the contact angle. By injection molding and imprinting processes, it is expected that fs laser-induced surface structures on metals can be replicated to the plastic surfaces and potentially beneficial to control the optical and wetting properties of the surface of injection molded and imprinted products.

Punching Shear Strength of RC Slabs by Simple Truss Model (단순 트러스 모델에 의한 철근콘크리트 교량 바닥판의 펀칭전단강도)

  • Lee, Yongwoo;Hwang, Hoonhee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.187-196
    • /
    • 2008
  • The punching shear strength of RC slabs is estimated analytically by the simple truss model. To avoid intrinsic difficulties in punching shear analysis of reinforced concrete slabs, the slabs were divided into three sub-structures as the punching cone and the remaining parts. The strength of the punching cone was evaluated by the stiffness of inclined strut. The stiffness of springs which control lateral displacement of the roller supports consists of the steel reinforcement which passed through the punching cone. Initial angle of struts was determined by curve fitting method of the experimental data with variable reinforcement ratio in order to compensate for uncertainties in the slab's punching shear, the simplification errors and the stiffness of the remaining sub-structures. The validity of computed punching shear strength by simple truss model was shown by comparing with experimental results. The punching shear strength, which was determined by snap-through critical load of shallow truss, can be used effectively to examine punching shear strength of RC slabs.

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

Anthropometric analysis of maxillary anterior buccal bone of Korean adults using cone-beam CT

  • Lee, Seung-Lok;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.92-96
    • /
    • 2010
  • PURPOSE. The aim of this study was to evaluate the thickness of buccal and palatal alveolar bone and buccal bony curvature below root apex in maxillary anterior teeth of Korean adults using Cone-beam CT images. MATERIALS AND METHODS. The 3D image was reconstructed with dicom file obtained through CBCT from 20 - 39 year old Korean subjects (n = 20). The thickness of buccal and palatal plate, root diameter, the buccal bony curvature angle below root apex and the distance from root apex to the deepest point of buccal bony curvature were measured on maxillary anterior teeth area using OnDemand3D program. RESULTS. Mean thickness of buccal plate 3 mm below CEJ was $0.68{\pm}0.29\;mm$ at central incisor, $0.76{\pm}0.59\;mm$ at lateral incisor, and $1.07{\pm}0.80\;mm$ at canine. Mean thickness of palatal plate 3 mm below CEJ was $1.53{\pm}0.55\;mm$ of central incisor, $1.18{\pm}0.66\;mm$ of lateral incisor, $1.42{\pm}0.77\;mm$ of canine. Bucco-lingual diameter 3 mm below CEJ was $5.13{\pm}0.37\;mm$ of central incisor, $4.58{\pm}0.46\;mm$ of lateral incisor, and $5.93{\pm}0.47\;mm$ of canine. Buccal bony curvature angle below root apex was $134.7{\pm}17.5^{\circ}$ at central incisor, $151.0{\pm}13.9^{\circ}$ at lateral incisor, $153.0{\pm}9.5^{\circ}$ at canine. Distance between root apex and the deepest point of buccal bony curvature of central incisor was $3.67{\pm}1.28\;mm$ at central incisor, $3.90{\pm}1.51\;mm$ at lateral incisor, and $5.13{\pm}1.70\;mm$ at canine. CONCLUSION. Within the limitation of this study in Korean adults, the thickness of maxillary anterior buccal plate was very thin within 1mm and the thickness of palatal plate was thick, relatively. The buccal bony curvature below root apex of maxillary central incisor was higher than that of lateral incisor and canine and it seems that the buccal bony plate below root apex of central incisor is most curved.

Experimental study on the spray characteristics of a dual-manifold liquid-centered swirl coaxial injector

  • Lee, Ingyu;Yoon, Jungsoo;Park, Gujeong;Yoon, Youngbin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.4
    • /
    • pp.444-453
    • /
    • 2014
  • A throttleable rocket engine enables operational possibilities such as the docking of spacecraft, maneuvering in a certain orbit and landing on a planet's surface, altitude control, and entrance to atmosphere-less planets. Thus, throttling methods have long been researched. However, dual-manifold injectors, which represent one throttling method, have been investigated less than others. In this study, dual-manifold and single-manifold injectors were compared to determine the characteristics of dual-manifold injectors. Also, the effects of gas injection were investigated with various F/O ratios. To investigate the characteristics, mass flow rate, spray pattern, spray angle, and droplet size were measured. The spray angle and droplet size were captured by indirect photography. About 30 images were taken to assess the spray patterns and spray angle. Also, 700 images were analyzed to understand the droplet distribution and targeting area, moving to the right from the centerline with 1.11-cm intervals. The droplet size was obtained from an image processing procedure. From the results, the spray angle showed two transition regions, due to swirl momentum in the swirl chamber regardless of the F/O ratio. The droplet size showed similar trends in both dual-manifold and single-manifold injectors except in the low mass flow rate region. In the case of the dual- manifold injector, the spray cone was not fully developed in the low mass flow rate region due to low angular momentum in the swirl chamber.

The Optimization of Fuel Injection Nozzles for the Reduction of NOx Emissions in a Large Diesel Engine (대형 디젤엔진의 NOx 저감을 위한 연료분사노즐 최적화 연구)

  • Yoon, Wook-Hyeon;Kim, Byung-Seok;Kim, Dong-Hun;Kim, Ki-Doo;Ha, Ji-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.60-65
    • /
    • 2004
  • Numerical simulations and experiments have been carried out to investigate the effect of fuel injection nozzles on the combustion and NOx formation processes in a medium-speed marine diesel engine. Spray visualization experiment was performed in the constant-volume high-pressure chamber to verify the numerical results on the spray characteristics such as spray angle and spray tip penetration. Time-resolved spray behaviors were captured by high-speed digital camera and analyzed to extract the information on the spray parameters. Spray and combustion phenomena were examined numerically using FIRE code. Wave breakup and Zeldovich models were adopted to describe the atomization characteristics and NOx formation processes. Numerical results were verified with experimental data such as cylinder pressure, heat release rate and NOx emission. Finally, the effects of fuel injection nozzles on the engine performance were investigated numerically to find the optimum nozzle parameters such as fuel injection angle, nozzle hole diameter and number of nozzle holes. From this study, the optimum fuel injection nozzle (nozzle hole diameter, 0.32 mm, number of nozzle holes, 8 and fuel injection angle, $148^{\circ}$) was selected to reduce both the fuel consumption and NOx emission. The reason for this selection could be explained from the highest fuel-air mixing in the early phase of injection due to the longest spray tip penetration and the highest heat release rate after $19^{\circ}$ ATDC due to the increased injection duration.