• Title/Summary/Keyword: Conducted emission

Search Result 1,240, Processing Time 0.027 seconds

INFLUENCE OF OPERATION PATTERNS OF LIGHT-DUTY FREIGHT VEHICLES ON NOx POLLUTION AT LOCAL ROADSIDES

  • Saito, A.;Ueki, S.;Takada, Y.
    • International Journal of Automotive Technology
    • /
    • v.7 no.3
    • /
    • pp.269-276
    • /
    • 2006
  • Running tests on roads were conducted to clarify the influences of road infrastructure, traffic condition and vehicle's emission level to the amount of emission at local roadsides, and to reveal the operation patterns which can reduce the emission peaks. NOx emission peaks of two light duty freight diesel vehicles which have different emission levels were evaluated by using an on-board measurement system. Tests were carried out with various payload conditions and road conditions. As a result many NOx emission peaks were observed when the vehicles were starting or accelerating at intersections. The test vehicle which has higher emission level caused higher frequency and level of NOx emission peaks. Shifting up at lower engine speed in combination with lower acceleration brought out not only reduction of NOx emission peaks level but also of $CO_2$ mass emission.

Searching for the environmental management plans of Korea paper industry coping with the new climate regime (신 기후체제 협약에 따른 국내 제지산업의 환경경영 방안 모색)

  • Kim, Dong Seop;Sung, Yong Joo
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.48 no.2
    • /
    • pp.75-82
    • /
    • 2016
  • The new climate regime for practical reduction in green house gas(GHG) emissions was launched in Paris at Dec. 2015. The Korea government would make various policies and plans in order to achieve the BAU 37 % emission reduction goals by 2030. In this study, the current situation and the possible corresponding methodology to the GHG emission reduction of Korea paper industry were investigated. Although the GHG emission reduction in KOREA paper industry has been successfully conducted compared with other industries until now, the more efforts for controlling GHG emission would be required to meet the new climate regime. The efficiency of various GHG reduction projects conducted by Korea paper companies was evaluated to find efficient way for GHG reduction. The certified methodologies of the external project based offset systems in Korea GHG emission trading scheme were also reviewed for providing the possible way to develope tailored methodology to the Korea paper industry.

A Study on Estimation of NOx and CO Emission Factor from Industrial and Commercial LNG Boilers (천연가스 사용 난방 및 산업보일러의 NOx와 CO 배출계수 산정 연구)

  • Jang, Young-Kee;Choi, Sang-Jin;Kim, Kwan;Song, Ki-Pong;Kim, Ho-Jung;Jung, Bong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.615-623
    • /
    • 2004
  • This study was conducted for developing the emission factors of nitrogen oxide(NOx) and carbon monoxide (CO) from the combustion boilers burning liquefied natural gas (LNG). These emission factors were compared with those of U.S. EPA and European Environment Agency (EEA). NOx and CO concentration in the flow gas were measured using Kane-May, KM9106 and Thermo Environmental Instruments Inc., 42C-HL. Measurement were conducted at thirty industrial and commercial LNG boilers. Emission factors were calculated on the basis of fuel consumption (kg-pollutant/㎥-fuel burned). NOx concentration at industrial boiler was 14~125 ppm and it was measured as 35~125 ppm at commercial boiler. NOx emission factors of industrial boiler and commercial boiler were 1.84kg/$m^3$ and 2.09kg/$m^3$, respectively. NOx emission factor of commercial boiler was higher than that of industrial boiler. The NOx emission factors estimated in this study were lower than those of U.S. EPA and higher than those of EEA. Average CO emission factor of industrial boiler was 0.65 kg/$m^3$ and at commercial boiler it was 0.70kg/$m^3$, CO emission factor at industrial boiler was lower than that at commercial boiler.

Conducted Emission of Inverter Power Sources for Resistance Welding

  • Mecke H.;Doebbelin R.;Winkler T.;Fischer W.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.60-63
    • /
    • 2001
  • Investigating electromagnetic emissions of inverter power sources for resistance welding existing special aspects of EMI measurements in the field of resistance welding machines resulting from the power rating and intermittent operation mode of these machines have to be taken into account. The characteristics of the internal switching processes determined by the behavior of the applied power semiconductors, snubber circuits and constructional aspects exert a great influence on the conducted emission of resistance welding inverters.

  • PDF

A study on Emission Reduction by DOC on Heavy Duty Diesel Engine (대형디젤기관에서 DOC에 의한 배출가스 저감에 관한 연구)

  • 한영출;류정호;오용석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.16-21
    • /
    • 1999
  • The diesel vehicle is relatively superior to gasoline vehicle on the fuel consumption, durability and combustion efficiency. However, exhaust emission from diesel vehicle are known to be harmful to human health and environment. The treatment technologies for the diesel exhaust gases are classified as replacement of fuel, quality control of diesel fuel, improvement of engine and aftertreatment system. The most effective for the treatment technology is known to be aftertreatment system, and this research is continuously conducted by many groups. The DOC system has many advantages of reducing particulates and harmful gaseous substances such as CO. HC. Moreover, it is simple in device structure, relatively low cost, and easy to install witout retrofitting the vehicle. In this study, experiment were conducted to analyze the effects on factors of oxidation characteristics and conversion efficiency of DOC. In experiment, test was conducted to estimate engine emission in 11,000cc diesel engine which was equipped with DOC.

  • PDF

Studies of $VOC_s$ Emission Rate Calculation in the Kwang-ju Area (광주지역의 $VOC_s$ 배출량산정에 관한 연구)

  • 이영재;신대윤
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.103-110
    • /
    • 2000
  • This study was conducted from January to December in Kwang-ju city, 1999. Calculated methods were studied by emission factors in each industrial species. The results was that total emission rate of VOC was calculated at a mount of 12305 ton/year as coating(49.4) > vehicles(27.4) > gasoline vapors(6.1) > petroleum refineries(5.6) > graphic arts(4.4) > road covering(4.1) > dry cleang(3.0%) respectively. In vehicles emission rate, passenger car and taxi were about 2,700 ton/yr(60%) of total vehicle emission(3,300 ton/yr). The amount of building emission rate was about 1,900 ton/yr(30%) of total coating emission 6,083 ton/yr.

  • PDF

Comparison of Emission Characteristics from Euro V Diesel Engine by Standard measurement Cycle in the Construction Equipment (EURO V 대응 건설기계 엔진의 표준시험모드에 따른 배출량 비교)

  • Yu, Seunghun;Joo, Taeheun;Lee, Chang-Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.143-144
    • /
    • 2014
  • The demand of diesel engine on the construction equipment has been rapidly increased because of thermal efficiency and power. But some of the construction equipment is imported from other country, since the their demands are not so large as compared with the other construction equipment. The imported construction equipments will be tested for emission with standard measurement mode. This study was conducted to measure emission characteristics of the construction equipment with changed standard measurement experimentally.

  • PDF

Numerical Simulations for Combustion and NOx Emission Characteristics in Oscillating Combustion Burner (수치해석을 이용한 맥동연소과정 및 NOx 배출특성 해석)

  • Kim, Hoo-Joong;Cho, Han-Chang
    • Journal of the Korean Society of Combustion
    • /
    • v.14 no.3
    • /
    • pp.37-44
    • /
    • 2009
  • An experimental study was conducted to reduce NOx emission in RT(radiant tube)burner by using oscillating combustion processes in RIST. A solenoid valve gives the various oscillating conditions, such as oscillation frequency, duty ratio of fuel flow. In this study, we used commercial software, CFD-ACE+ to predict combustion and NOx emission characteristics for various experimental oscillation conditions. The effect of oscillation frequency and duty ratio on NOx emission will be discussed in terms of flow field, temperature and equivalence ratio distributions in detail.

  • PDF

Analysis of Emission Characteristics of DC/DC Converter by Component Placement (부품배치에 따른 DC/DC 컨버터의 Emission 특성분석)

  • Park, Jin-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.639-643
    • /
    • 2018
  • As electronic systems become smaller and more portable, the need for power conversion continues to increase. In addition, system stability must be ensured from switching noise due to power conversion efficiency and power conversion system miniaturization. Therefore, countermeasures to reduce switching noise during power conversion are essential. In this paper, a DC/DC buck converter circuit is constructed, and the characteristics of switching noise generated when changing the parts layout in a four-layer printed circuit board (PCB) structure with a reference plane are compared and analyzed. In addition, switching noise characteristics were compared and analyzed through simulations when the parts layout was different in a two-layer PCB structure from which the reference planes were removed. As a result, it was confirmed that the radiated emissions characteristic is reduced by 12dB and the conducted emissions characteristic decreased by 7dB to 8dB, according to the current return path in the four-layer PCB structure. Thus, it was confirmed that the noise characteristics can be improved according to the configuration of the current return path when the power conversion circuit is designed.

Uncertainty Assessment for CAPSS Emission Inventory by DARS (DARS에 의한 CAPSS 배출자료의 불확도 평가)

  • Kim, Jeong;Jang, Young-Kee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.1
    • /
    • pp.26-36
    • /
    • 2014
  • The uncertainty assessment is important to improve the reliability of emission inventory data. The DARS (Data Attribute Rating System) have recommended as the uncertainty assessment technic of emission inventory by U.S. EPA (Environmental Protection Agency) EIIP (Emission Inventory Improvement Program). The DARS score is based on the perceived quality of the emission factor and activity data. Scores are assigned to four attributes; measurement/method, source specificity, spatial congruity and temporal congruity. The resulting emission factor and activity rate scores are combined to arrive at an overall confidence rating for the inventory. So DARS is believed to be a useful tool and may provide more information about inventories than the usual qualitative grading procedures (e.g. A through E). In this study, the uncertainty assessment for 2009 CAPSS (Clean Air Policy Support System) emission inventory is conducted by DARS. According to the result of this uncertainty assessment, the uncertainty for fugitive dust emission data is higher than other sources, the uncertainty of emission factor for surface coating is the highest value, and the uncertainty of activity data for motor cycle is the highest value. Also it is analysed that the improvement of uncertainty for activity data is as much important as the improvement for emission factor to upgrade the reliability of CAPSS emission inventory.