• Title/Summary/Keyword: Conditioning diagnosis

Search Result 80, Processing Time 0.026 seconds

Development of Software For Machinery Diagnostics by Adaptive Noise Cancelling Method (1St: Cepstrum Analysis)

  • Lee, Jung-Chul;Oh, Jae-Eung;Yum, Sung-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.836-841
    • /
    • 1987
  • Many kinds of conditioning monitoring technique have been studied, so this study has investigated the possibility of checking the trend in the fault diagnosis of ball bearing, one of the elements of rotating machine, by applying the cepstral analysis method using the adaptive noise cancelling (ANC) method. And computer simulation is conducted in oder to identify obviously the physical meaning of ANC. The optimal adaptation gain in adaptive filter is estimated, the performance of ANC according to the change of the signal to noise ratio and convergence of LMS algorithm is considered by simulation. It is verified that cepstral analysis using ANC method is more effective than the conventional cepstral analysis method in bearing fault diagnosis.

  • PDF

Pediatric Dysphagia (기질적 섭식장애)

  • Kim, Min-Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.12 no.sup1
    • /
    • pp.77-84
    • /
    • 2009
  • Pediatric dysphagia comes from disturbances in swallowing process, which has 'preparatory phase', 'oral phase', 'pharyngeal phase', and 'esophageal phase', and mainly the causes are neuro-muscular discoor-dination. It is necessary to recognize clinical manifestation if they have accompanied organic disorder and diagnose accurately. Videofluoroscopic study evaluation is a valuable method to find out abnormal swallowing mechanism at each phases. Treatment should be diagnosis specific, and multidisciplinary team approach is desirable. We can use various behavioral techniques to facilitate normal swallowing mechanism including conditioning of oral and pharyngeal structures, bolus manipulation, postural compensation, and adaptive feeding utensils. Important point is that the diagnosis and treatment for pediatric dysphagia should not be delayed because children are under development.

A Study of Rule-based Fault Detection Algorithm in the HVAC System (규칙기반 고장진단 알고리즘의 실험적 연구)

  • Cho, Soo;Tae, Choon-Seob;Jang, Cheol-Yong;Yang, Hoon-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.241-246
    • /
    • 2005
  • The objective of this study is to develop a rule-based fault detection and diagnosis algorithm and an experimental verification using air handling unit. To develop an analytical algorithm which precisely detects a faulted component, energy equations at each control volume of AHU were applied. An experimental verification was conducted in the AHU at Green Building in KIER. In the experiment conducted in hot summer condition, the rule based FDD algorithm isolated a faulted sensor from HVAC components.

  • PDF

Real-time steady state identification technology of a heat pump system to develop fault detection and diagnosis system (열펌프의 고장감지 및 진단시스템 구축을 위한 실시간 정상상태 진단기법 개발)

  • Kim, Min-Sung;Yoon, Seok-Ho;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.282-287
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF

A Study on Steady-State Criterion based on COV and a Fault Detection Method during GHP Operation (GHP 운전시 COV에 의한 정상상태 판별 및 이상검출 방법 연구)

  • Shin, Young-Gy;Oh, Se-Jae;Jeong, Jin-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.705-710
    • /
    • 2011
  • Fault detection has to be proceeded by steady state filtering to get rid of transient effect associated with thermal capacity. Coefficient of variance (COV), ratio of standard deviation devided by moving average, was employed as steady-state filter. Engine speed and refrigerant pressures were selected as parameters representing system dynamics. The filtered values were registered as members of steady-state DB. They were found to show good functional relationship with ambient temperature. The relationship was fitted with a second order polynomial and the distribution bounds of the data around the fitted curve were expressed by visual inspection because of varying average and random data interval. Fault data were compared with the steady-state data obtained during normal operation. The fault data were easily isolated from the fault-free one. To make such isolation reliable, tests to construct good DB should be designed in a systematic way.

Selecting of the Energy Performance Diagnosis Items through the Sensitivity Analysis of Existing Buildings (민감도 분석을 통한 기존건축물의 에너지성능 진단항목 선별)

  • Kong, Dong-Seok;Chang, Yong-Sung;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.354-361
    • /
    • 2015
  • The building energy audit is an important process when collecting basic information for improving the energy performance of existing buildings. Audit parameters should be associated with the energy performance of the building. Such audit parameters will vary according to an individual building's characteristics and energy consumption patterns, but most building energy audits are performed in the same way. The sensitivity analysis (SA) is a statistical method to quantify the correlation between inputs and outputs that can determine which input is influential to which output. Therefore, an SA can identify influential parameters when applied to building energy analysis. In this paper, we adopted the Morris method to identify building energy audit parameters and performed a Monte Carlo simulation for uncertainty analysis. As a result, this method was able to identify an influential parameter for building energy audits and reduce uncertainty in energy consumption in buildings.

A Development of the On-line Maintenance and Management System for the HVAC Systems and the Evaluation of Its Effects (공조설비 온라인 유지관리시스템 개발 및 효과분석)

  • Lee, Tae-Won;Kim, Yong-Ki;Woo, Nam-Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.11
    • /
    • pp.591-598
    • /
    • 2009
  • The service quality with the various building equipments tends to depend on the individual superintendent's capability and efforts generally and this often lead to poor maintenances and managements of them. N-BMS(Networked Building Management System), proposed in this study, is a new type of building management method, which links principal equipments within many buildings into a communication network and carries out several significant missions such as fault detection, deterioration diagnosis and control the equipments and so on, as well as monitoring which is the main and unique purpose of the conventional BMS. How to construct the N-BMS was considered to keep performance of equipments high and thus to save energy and resource. LCC(Life Cycle Cost) based analysis was also performed in order to verify the effects of some maintenance and management works for the building HVAC systems.

Measurement and Analysis of Energy Consumption of HVAC Equipment of a Research Building (연구용 건물의 열원 및 공조기기의 에너지 소비량 측정 및 분석)

  • Kim Seong-Sil;Kim Youngil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.914-922
    • /
    • 2004
  • In this study, measurement and analysis of energy consumption of a research building have been conducted. The energy audit procedure includes monitoring of electricity and LNG consumption over a period of three yews from 2000 to 2002. Data acquisition system for collecting energy consumption data of HVAC equipment such as chillers, fan filter units, AHUs, cooling towers, boilers, pumps, fan coil units, air compressors and etc. has been installed in a building located in Seoul. Data collected at an interval of 1 minute are analyzed for studying the energy consumption pattern of a research building. Percentage of energy consumption of all HVAC equipment is $51.0\%$ in 2000, $55.4\%$ in 2001, and $62.3\%$ in 2002, respectively. Electricity consumption of chillers accounts for $17.6\%$ of the total energy consumption, which is the largest. Annual energy consumption-rate per unit area is $840.5Mcal/m^2{\cdot}y$ in 2000, $1,064.8Mcal/m^2{\cdot}y$ in 2001, and $1,393.0Mcal/m^2{\cdot}y$ year 2002, respectively.

Development of Diagnosis of Trouble Model for Effective Operation of Air-compressor (효율적인 공기압축기 운영을 위한 이상진단모델 연구)

  • Im, Sang Don;Jung, Young Deuk;Kim, Jong Rae
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.239-248
    • /
    • 2014
  • Most systems used in industrial sites, actually have non-linearity and uncertainty. Therefore there are a lot of difficulties in evaluating conditions of these systems. Generally, the quantitative analysis and expression are found hard because the general public cannot easily make an accurate interpretation on the systems. Thus development of a system that utilizes an expertise from skilled analysts is required. In this research, a real-time sensor signal conditioning system and Fuzzy-expert system have been separately set up into an inference algorithm. So that it ensures a fast, accurate, objective and quantitative operational condition value provided to the manager. Therefore, FE_AFCDM is suggested in this literature, as an effective system for diagnosing the problems related to the air compressor. It can quantify the uncertain and absurd condition to operate the air compressor facilities safely and financially.