• 제목/요약/키워드: Conditioners

검색결과 312건 처리시간 0.023초

가전기기 에너지소비효율 기준설정에 관한 연구 (Study on Appliance Energy Efficiency Standards)

  • 이선근;최수현
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 춘계학술발표회 초록집
    • /
    • pp.144-150
    • /
    • 1996
  • The Energy Efficiency Standards and Labelling Act, as amended by the Rational Energy Utilization Act, provides energy efficiency standards and labellings for six equipment categories(viz, refrigerators, air-conditioners, fluorescent lamps and ballasts, incandescent lamps, cars) authorizes the Ministry of Trade. Industry and Energy (MOTIE) to prescribe amended or new energy efficiency standards and labelling standards. This study was initiated by the KIER(Korea Institute of Energy Research) in 1992. KIER's assessment of the appliance energy efficiency standards is designed to evaluate their statistical and engineering analysis according to Korean Industrial Standards(KS). And to make didtinction between the poor efficiency and good efficiency models. 5 grades are classified depending on their tested energy efficiency. This year, based on our analysis, MOTIE mandated updated standards for refrigerators, air-conditioners, Incandescent lamps, and fluorescent lamps.

  • PDF

VRF 응용 Hybrid 공조시스템 Case Study (Case Study of Hybrid HVAC system Applied VRF)

  • 김성실;박완규;허인구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.357-362
    • /
    • 2008
  • The present study has been conducted variable refrigerant flow system applied building. Multi air-conditioning system has some benefits : easier building management and maintenance and energy saving. Recently, the system heat pump has been employed in medium-sized and tall buildings. However, the performance data and design method for system heat pump are limited in literature due to complicated system parameters and operating conditions. In the present study, case study of a system heat pump applied various building. The aim of this paper is to application multi air-conditioners and to inform the benefits of multi air-conditioners.

  • PDF

The In-situ Dressing of CMP Pad Conditioners with Novel Coating Protection

  • Sung, James-C.;Kan, Ming-Chi
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1142-1143
    • /
    • 2006
  • Kinik Company pioneered diamond pad conditioners protected by DLC barrier ($DiaShield^{(R)}$ Coating) back in 1999 (Sung & Lin, US Patent 6,368,198). Kink also evaluated Cermet Composite Coating (CCC or $C^3$, patent pending) with a composition that grades from a metallic (e.g. stainless steel) interlayer to a ceramic (e.g. $Al_2O_3$ or SiC) exterior. The metallic interlayer can form metallurgical bond with metallic matrix on the diamond pad conditioner. The ceramic exterior is both wear and corrosion resistant. The gradational design of $C^3$ coating will assure its strong adherence to the substrate because there is no weak boundary between coating and substrate.

  • PDF

An Experimental Study for Noise Reduction of the Cross-Flow Fan of the Room Air-Conditioners

  • Koo, Hyoung-Mo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.89-100
    • /
    • 2000
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectra of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed, which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared with and without the bounding fence for various flow rates.

  • PDF

에어컨용 직교류홴의 저소음화를 위한 실험적 연구 (An experimental study for noise reduction of the cross-flow fan of the room air-conditioners)

  • 구형모
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.871-879
    • /
    • 1999
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectrums of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared of the experimental rig with and without the bounding fence for various flow rates.

  • PDF

흐름성 개선제가 건조 마늘 분말의 유동성에 미치는 효과 (Effect of Some Anti-caking Conditioners on the Flowability of Dried Garlic Powder)

  • 이영수;강희호;장규섭;장영일
    • 한국식품과학회지
    • /
    • 제30권6호
    • /
    • pp.1357-1361
    • /
    • 1998
  • It has been shown that the physical properties of three anti-caking conditioners added garlic powders can be monitored and evaluated by some tests. The test parameters obtained are all quantifiable for powders fundamental properties. It is clear that cellulose powder and calcium carbonate are not attributed to the particle surface improvement effects. When SSA added 2% (w/w) for garilic powder which is improved flow ability and attractive index. Bulk density and compressibility were more sensitive indices to changes occurring in some conditioner added garlic powders.

  • PDF

천장형 시스템 에어컨의 음향 특성 (Acoustical Characteristics of System Air Conditioners Installed in the Ceiling)

  • 김수연;유진;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.662-665
    • /
    • 2005
  • In this study acoustical characteristics of system air conditioner in different ceiling systems was investigated in anechoic and real conditions. Same Types of air conditioners were installed in two different rooms. The results showed that motor's tonal component was emphasized at near fart of air blast blower in the exposed type while fan's harmonic component is emphasized rather in the enclosed type. This confirms tile result of acoustical intensity mapping which showed that Intensity level of 125Hz octave band increased in the exposed type while there was no noticeable difference at the frequency band in the enclosed type.

  • PDF

유기물의 토양 개량 효과 측정 (The Measurement of Soil Conditioning Effects of Organic Materials)

  • 주영규
    • 아시안잔디학회지
    • /
    • 제7권1호
    • /
    • pp.13-18
    • /
    • 1993
  • Much attention has been given recently to solve the environmental contamination in golf courses Changing to culture practice rather than chemical practice that depends on pesticides and fertilizers is a hot issue in golf courses or grasslands. Organic soil conditioners improve soil-plant envirormental conditions rich in physical properties. In this study, measuring systems to evaluate soil conditioning effects were set up for on-site purpose. After establishing the methodology for evaluating soil conditioner effects, 2 kinds of organic conditioners were rested for examination. The systems for the methodology included a set of simulating equipment for field capacity, an impact type soil column compactor, and an infiltration-percolation system. Test results using the systems showed bulk density and infiltration rate of mixed soil were decreased at highter rates of conditioner, but total porocities were increased. Increased porocities were most capillary pore space which has a positive effect on soil water potential. The systems and methodology in this study seem to have an efficiency to measure the effects of soil conditioner on site purpose.

  • PDF

타원관 열교환기의 열전달 특성 (Heat Transfer Characteristics of Oval-Tube Heat Exchanger)

  • 윤점열;이욱용
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.292-301
    • /
    • 2000
  • This study experimentally investigates an air-side performance of oval tube heat exchanger against round tube heat exchanger using scaled-up model experiment for home air conditioners. A plain fin and round tube heat exchanger with 21 FPI(fins per inch) was used as a reference heat exchanger, and these were applied equally to 4 oval tube heat exchangers. Oval tube samples were designed with the same perimeter as 7.5mm diameter round tube, and their aspect ratios were 1:2, 1:3, respectively. In this study, the heat transfer and pressure drop characteristics of oval tube heat exchangers against round tube heat exchanger were also compared to one another, and an optimal samples for home air conditioners was recommended. And, general performance characteristics for an optimum oval tube samples chosen in this work was compared with round tube heat exchanger.

  • PDF