• Title/Summary/Keyword: Conditioners

Search Result 312, Processing Time 0.026 seconds

Active Control of Noise Transmitted through Ventilation Openings of the Machinery Room of Refrigerator (무부하 압축기에 의한 냉장고 기계실 소음의 능동제어)

  • Koo, Jung Mo;Jeong, Weui Bong;Kim, Tae Hoon;Hong, Chinsuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.475-482
    • /
    • 2016
  • The active control of noise generated by the compressor and transmitted out of the machine room through the windows is implemented based on the FIR filter. The machine room contains most of noise sources of electric home appliances, air-conditioners and refrigerators, for example. To actively reduce the noise from the machinery room. In this paper, the transfer function of the controller for minimization of the acoustic power transmitted through the windows is mathematically formulated. The transfer functions required for implementation of the active controller are the measured. The measurements are conducted in this initial stage under the operation of the compressor with no load. For improvement of the reliability of the transfer function of the compressor to the acoustic power, additional operational measurements are performed. The real time controller is implemented based on the FIR filter using the measured transfer functions and the performance of the active controller is estimated. Control performance is measured about 3 dB ~ 10 dB in reduction of the sound power at the peaks of the compressor noise.

The Development Program of the Collection for Korean Classical Materials in the University Library - With emphasis on the library of Pusan National University (대학도서관에서의 고전자료 개발방안 -부산대학교 도서관을 중심으로-)

  • Song Jung-Sook
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.25
    • /
    • pp.215-232
    • /
    • 1993
  • The Long-Term Development Plan of the Pusan National University(PNU) has announced on 1991 in order to reach its roles and levels as an University with international standards, a Graduate School research-oriented and a core university in its community through accomplishment of this Plan. University libraries would be planned to support their universities' goals. Therefore the Library of PNU is facing on the task for supporting the Plan. The Collection for Korean Classical Materials (CKCM) is not limited in Korean Literature, Korean History, Korean Philosophy fields but covered the academic fields except a hightech science : Humanities, social science. pure science, applied science and arts etc. However, the Library of PNU does not have the organization, special librarian and budget for CKCM. Under this notion organization, budget and librarian for the collection would be followed. The CKCM contains the original editions, photography editions, copied issues. microform reproductions with comprehensive subjects in the fields of studies. Especially for the collection of treasure books the role of the Library of PNU induce to open individuals' collections or families' collections to public through the Library. The equipments for preserving rare books and treasure books are the conditioners for humidity and temperature, automatic extinguishment system. The reference materials, copy machine and reading room are requested for the user service of CKCM. The materials would be one of the most important thing in study and research. Therefore the Library of PNU need to pay attention to develop and preserve CKCM.

  • PDF

Effect of Conditioning Methods and Tedding Frequency on the Drying Rate and Quality in Italian Ryegrass Hay (컨디셔닝 방법 및 반전횟수가 이탈리안 라이그라스 건초의 건조 및 품질에 미치는 영향)

  • Park, Hyung Soo;Kim, Ji Hye;Seo, Sung;Jung, Jong Sung;Lee, Sang Hack;Lee, Ki Won;Choi, Gi Jun
    • Journal of Animal Environmental Science
    • /
    • v.19 no.1
    • /
    • pp.69-74
    • /
    • 2013
  • A field experiment was carried out to determine the effects of conditioning methods and tedding frequency on the drying rate and quality of Italian ryegrass hay. Italian ryegrass was cut with three types of mower conditioners (un conditioned, impeller, roller) and tedded with rake-tedder once or twice daily during field curing. The field drying rate of Italian ryegrass hay was the highest in roller conditioner. Conditioning treatment shorten the date from 1 to 1.5 compare with unconditioned. Drying rate of Italian ryegrass plant had been affected by tedding frequency within 3 days after it was cut, but it was ineffective after 3 days. There is no effect on acid detergent fiber (ADF) and neutral detergent fiber (NDF) but effect crude protein (CP) and relative feed value (RFV) by conditioning treatment in nutritive value of Italian ryegrass hay.

Development of Variable Duty Cycle Control Method for Air Conditioner using Artificial Neural Networks (신경회로망을 이용한 에어컨의 가변주기제어 방법론 개발)

  • Kim, Hyeong-Jung;Doo, Seog-Bae;Shin, Joong-Rin;Park, Jong-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.399-409
    • /
    • 2006
  • This paper presents a novel method for satisfying the thermal comfort of indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. Korea Electric Power Corporation (KEPCO) use the fixed duty cycle control method regardless of the indoor thermal environment. However, this method has disadvantages that energy saving depends on the set-point value of the Air-Conditioner and direct load control (DLC) has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. In this paper, the variable duty cycle control method is proposed in order to compensate the weakness of conventional fixed duty cycle control method and improve the satisfaction of residents and the reduction of peak demand. The proposed method estimates the predict mean vote (PMV) at the next step with predicted temperature and humidity using the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. To verify the effectiveness of the proposed variable duty cycle control method, the case study is performed using the historical data on Sep. 7th, 2001 acquired at a classroom in Seoul and the obtained results are compared with the fixed duty cycle control method.

Sensorless Control Algorithm of a Surface Mounted PM Synchronous Motor Under Naturally Rotating by Load (외부부하에 의해 회전중인 표면부착형 영구자석동기전동기의 센서리스 제어 알고리즘)

  • Lee, Han-Sol;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.16-23
    • /
    • 2018
  • PM synchronous motor may be rotated to an arbitrary direction and speed by outside wind under natural condition in cases where the fan is applied outside, such as in vehicle radiators and outdoor air-conditioners. Sensorless controls that cannot detect rotor position requires additional sensorless control algorithm because a rotor is rotated by an external load. In this study, the sensorless control of a PM synchronous motor under naturally rotating condition is proposed. The natural rotation conditions are classified as forward high-speed rotation, reverse high-speed rotation, and low-speed rotation. Experiment results verify the performance of the sensorless control, including the rotor speed and position detection at natural rotation mode and switch to the closed-loop sensorless control.

A Numerical Study on Flow through a Cross Flow Fan: Effect of Blade Shapes on Fan Performance (직교류 홴의 유동 해석: 깃 형상 변화가 성능에 미치는 영향)

  • Hur, Nahm-Keon;Kim, Wook;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.96-102
    • /
    • 1999
  • Cross flow fans are used in various applications, especially in industrial ventilation applications and in room air conditioners, due to their superior performance characteristics. Unlike radial and/or axial fans, the design of cross flow fans have been mostly based on earlier experiences and experiments. In the present study, numerical computations of flow fields through a cross flow fan used in room air conditioner are performed to investigate the detailed flow fields and to study the effect of the blade shape on performance curves to aid better design of the fan. Despite some discrepancies between the two results, it is seen from the present study that the computational results agree quite well with the qualitative experimental results. It is also shown from the present study that by having a different shape of blade, it is possible to achieve about $15\%$ increase in flow rates. The stimulating results of the present study can be used in the design of high performance cross flow fans with the use of optimal design algorithm and experimental verifications.

  • PDF

Prediction of the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners used in the Field (실공간 사용 공기조화가용 열교환기의 공기측 파울링 특성 예측)

  • Hwang, Yu-Jin;Kim, Gil-Tae;Jeong, Seong-Il;Lee, Jae-Geun;Ahn, Young-Chull
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.306-310
    • /
    • 2005
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. An empirical modeling equation is derived from the experimental results using accelerated tests and it shows good predictions of the fouling characteristics of the slitted finned tube heat exchangers. However the modeling equation predicts only the fouling characteristics of new heat exchangers and it can not predicts fouling characteristics obtained from actual field data. The purpose of this study is to modify the previous modeling equation using the actual field data Therefore an modified modeling equation is proposed and it shows good predictions of the actual fouling characteristics of finned-tube heat exchangers.

  • PDF

A Development of Heat Exchanger by using Small Bore Two-Port Tube (연결세경관을 이용한 열교환기의 개발)

  • Lee, Sangmu;Park, Byung-Duck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.63-68
    • /
    • 2015
  • The fin and tube type heat exchangers widely used in air conditioners have been developed to improve on the heat transfer performance and compactness. This study presents the new type of tube for the heat exchanger to improve the heat transfer performance by increasing the heat transfer area per unit volume in the air-conditioner heat exchanger. The new type tube can be used for mechanical expansion facility, due to the two-port copper tube. Numerical calculation shows that the heat exchanger using the two-port copper tube outperforms the conventional heat-exchanger using a circular copper tube, in terms of the increased heat transfer coefficient and higher pressure drop. The calculation results were experimentally validated and are in agreement with the experimental results. Compared to the heat exchanger using a conventional circular tube, the heat exchanger with a two-port tube increased the heat transfer coefficient up to 21%, and the pressure dropped up to 16%.

A Subjective Evaluation on the Noise Environment of the Low-rise Multifamily House in Athens, U. S. A (미국 저층 공동주택 거주자의 소음 환경에 대한 주관적 평가 - Athens시를 중심으로 -)

  • 곽경숙
    • Korean Journal of Human Ecology
    • /
    • v.1 no.2
    • /
    • pp.61-74
    • /
    • 1998
  • The purpose of this study is to investigate residents subjective opinion of the noise on the low-rise multifamily house in U.S.A. The results of this study can be applied for the prevention of noise when planning cities, roads, and multifamily houses in Korea. The subjects of this study are three kinds of multifamily houses and their 109 residents in Athens, U.S.A. The results of this study are as follows. The residents felt the noise from lawn mowers and the sound from filter fans of air conditioners were higher than in the other external noise. The residents daily activities were disturbed a little by the external noise. Of the internal noise, the air home sound was recognized a little by residents. They only felt a moderate sound level from the building services of the solid borne sound. They suffered worse from noise in the summer and they felt worse from 16∼20 o'clock due to noise. The residents who were living in town houses felt better than those in the other multifamily houses. (Korean J Human Ecology 1(2):61∼74. 1998)

  • PDF

Study on the Collector Efficiency of an Air Heater in a Solar Air Conditioning System (태양열 이용 냉난방 공조시스템 중 공기식 집열기의 집열효율에 관한 연구)

  • Kim, B.C.;Shin, H.J.;Choi, K.H.;Kum, J.S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.1-8
    • /
    • 2000
  • The suggested year round solar air conditioning system has been developed for cooling and heating. In particular, this system focused on cooling and dehumidification and it could reduce a peak time owing to the use of air conditioners in summer. This study was performed to find out how much heating loads could be saved and furthermore whether this suggested system would be possible to do heating without a switch of system in real situations. Through model house experiments, the following conclusions were obtained. 1) The collector efficiency was 36% at maximum, but more improved structure of suggested collector could increase its efficiency. 2) The temperature of outlet air was about $30^{\circ}C$ and it could reduce heating loads. 3) Measured temperature and calculated one agreed well within ${\pm}1.5^{\circ}C$.

  • PDF