• Title/Summary/Keyword: Condition check

Search Result 804, Processing Time 0.027 seconds

Design of FPGA-based Wearable System for Checking Patients (환자 체크를 위한 FPGA 기반 웨어러블 시스템 설계)

  • Kang, Sungwoo;Ryoo, Kwangki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.477-479
    • /
    • 2017
  • With the recent advances in medical technology and health care, the prevention and treatment of diseases has developed. Accordingly aging has rapidly progressed. In this life span and aging society, demand for diagnostic centered medical care is increasing rapidly. In this paper, we propose a wearable patient check system based on FPGA that can be controlled by sensors. In the existing hospital, a doctor or nurse visited the patient every hour to check the condition. However, in this paper, patients, doctors and nurses can check the patient's condition at the desired time using patient check system. In addition, the tilt sensor is used for the patient who is uncomfortable to easily control. The proposed FPGA-based hardware architecture consists of an algorithm for enlarged image processing, a TFT-LCD Controller, a CIS Controller, and a Memory Controller to output the patient's status image. Implemented and validated using the DE2-115 test board with Cyclone IV EP4CE115F29C7 FPGA device and its operating frequency is 50MHz.

  • PDF

High Speed Korean Morphological Analysis based on Adjacency Condition Check (인접 조건 검사에 의한 초고속 한국어 형태소 분석)

  • 심광섭;양재형
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.1
    • /
    • pp.89-99
    • /
    • 2004
  • This paper proposes a morphological analysis method that enables morphological analysis by checking conditions between two adjacent morphemes. These conditions are fed from a dictionary. This method eliminates a code conversion module and the application of transformational rules for candidate generation. The method claims that very high speed morphological analysis is attainable through simple bit operations for adjacency condition check. MACH, an implementation of the proposed method, is a supersonic Korean morphological analyzer which is able to analyze a document of 1 GB in 5 minutes on a PC with 1.13 GHz Pentium III CPU. The analysis accuracy of MACH is 99.2 %.

Evaluation of Thermal Comfort during Sleeping in Summer - Part I : On Results of Questionnaire Before and After Sleep - (여름철 수면시 온열쾌적감 평가 - 제1보 : 수면 전후 설문에 관하여 -)

  • Kim Dong-Gyu;Kum Jong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.404-409
    • /
    • 2005
  • This study is to investigate effects of thermal conditions on sleep. Five female university students participated in the sleep experiment. Three temperature levels (22, 26, and $30^{\circ}C$) were given, and relative humidity was maintained to $50\%$. When as subject arrived in the chamber at 9 o'clock in the evening, questionnaire was given to check physical and psychological conditions. After checking conditions, subjects went to bed till 07 : 30 in the morning. Body movement was checked during sleeping. After sleep in the chamber, questionnaire was given to the subject in order to check sleep quality. Subjects evaluated sleep quality by themselves by answering the time they fall asleep and wake up, frequency of wake during sleep, causes of each waking, and feeling after sleep. Sleep quality was rated with 7-point scale. At $30^{\circ}C$ condition, body movement was significantly higher than of other thermal conditions. The best sleep quality was obtained at the $26^{\circ}C$ condition, while the worst sleep was taken at the $30^{\circ}C$ condition.

A SURVEY OF REPEATED DENTAL TREATMENT UNDER GENERAL ANESTHESIA FOR DISABILITIES (장애인 환자의 전신마취 하 반복된 치과치료에 대한 조사)

  • Choi, Hyojung;Nam, Soonhyeun;Kim, Hyunjung
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.13 no.2
    • /
    • pp.73-79
    • /
    • 2017
  • The purpose of this study was to analyze the dental treatment of patients with disabilities, especially according to the frequency of general anesthesia, and to propose the improvements in oral care. The subjects of the present study were 85 patients including age, sex, medical condition, dental treatment and the number of general anesthesia. The patients were divided into regular and irregular check groups according to their follow-up patterns. These two groups were compared for the frequency of general anesthesia and the type of repeated treatment. The results showed that restorative treatment was superior in numbers under first visit of general anesthesia. And more general anesthesia was performed in the irregular recall check group compared with the regular recall check group. This survey suggest that easy access to a dental clinic and the convenience of treatment is needed. On the other hand, there is a time limit on the dental care for disabilities by the dentist. Therefore oral care training program should be simultaneously provided for parents to improve the efficiency of dental care at home. In conclusion, efforts should be made for more comprehensive and effective dental care including regular recall check and preventive home care for disabilities.

Solidification Analysis Characteristics of Back Flow Prevention Check Valve (역류방지 체크밸브의 응고해석 특성)

  • Yoon, Jung-In;Moon, Jung-Hyun;Son, Chang-Hyo;Lee, Jung-Jin
    • Journal of Power System Engineering
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2015
  • Check valves used in vessels include shock-release function on piping system, aside from basic back flow prevention. However, proper and enough protection of system is not obtainable due to use of high-pressure and bulk fluids, resulting from enlargement of vessels. In this study, casting analysis of check valves protecting systems in flow path from water hammering or back flow is conducted, using Z-CAST program. Also, molten metal filling, flow analysis, solidification analysis and shrinkage cavity analysis are conducted. The main results are as following. Regarding filling of each risering, molten metal showed stable supply condition without being isolated. It was identified that the final solidification exists on risering, but shrinkage cavity possibly might happens at the point of isolation solidification.

Pollution investigation of ventilated system in super market and hotel's air condition in Kunming city

  • Zhang, Liang;Wang, Xin;Liu, Xinhai
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.12a
    • /
    • pp.12-14
    • /
    • 2004
  • Objective to know about pollution of ventilated system in super market and hotel's air condition in Kunming. Methods to take out 28 ventilated system from super markets and hotels in Kunming in march 2004. To check dirt amount in pipelines and microorganism in dirt. Testing result is appraised under 'Public hygiene standard of ventilated system in air condition'. Results pollution problem exist in different degree in all the super markets and hotels that have been investigated. There is 32.14% which means 8 hotels and 1 super market, pollution is serious, The others (67.86%) is medium. Conclusion pollution problems exist in air condition system in all super markets and hotels of Kunming. Discussion aim at Kunming's special weather, and present condition of public ventilated system, discussing ways of management in hygiene of air condition system.

  • PDF

Development and Assessment of Real-Time Quality Control Algorithm for PM10 Data Observed by Continuous Ambient Particulate Monitor (부유분진측정기(PM10) 관측 자료 실시간 품질관리 알고리즘 개발 및 평가)

  • Kim, Sunyoung;Lee, Hee Choon;Ryoo, Sang-Boom
    • Atmosphere
    • /
    • v.26 no.4
    • /
    • pp.541-551
    • /
    • 2016
  • A real-time quality control algorithm for $PM_{10}$ concentration measured by Continuous Ambient Particulate Monitor (FH62C14, Thermo Fisher Scientific Inc.) has been developed. The quality control algorithm for $PM_{10}$ data consists of five main procedures. The first step is valid value check. The values should be within the acceptable range limit. Upper ($5,000{\mu}g\;m^{-3}$) and lower ($0{\mu}g\;m^{-3}$) values of instrument detectable limit have to be eliminated as being unrealistic. The second step is valid error check. Whenever unusual condition occurs, the instrument will save error code. Value having an error code is eliminated. The third step is persistence check. This step checks on a minimum required variability of data during a certain period. If the $PM_{10}$ data do not vary over the past 60 minutes by more than the specific limit ($0{\mu}g\;m^{-3}$) then the current 5-minute value fails the check. The fourth step is time continuity check, which is checked to eliminate gross outlier. The last step is spike check. The spikes in the time series are checked. The outlier detection is based on the double-difference time series, using the median. Flags indicating normal and abnormal are added to the raw data after quality control procedure. The quality control algorithm is applied to $PM_{10}$ data for Asian dust and non-Asian dust case at Seoul site and dataset for the period 2013~2014 at 26 sites in Korea.

Analysis of Performance according to LDPC Decoding Algorithms (저밀도 패리티 검사부호의 복호 알고리즘에 따른 성능 비교 분석)

  • Yoon, Tae Hyun;Park, Jin Tae;Joo, Eon Kyeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.11
    • /
    • pp.972-978
    • /
    • 2012
  • LDPC (low density parity check) code shows near Shannon limit performance by iterative decoding based on sum-product algorithm (SPA). Message updating procedure between variable and check nodes in SPA is done by a scheduling method. LDPC code shows different performance according to scheduling schemes. The conventional researches have been shown that the shuffled BP (belief propagation) algorithm shows better performance than the standard BP algorithm although it needs less number of iterations. However the reason is not analyzed clearly. Therefore the reason of difference in performance according to LDPC decoding algorithms is analyzed in this paper. 4 cases according to satisfaction of parity check condition are considered and compared. As results, the difference in the updating procedure in a cycle in the parity check matrix is considered to be the main reason of performance difference.

AN EKELAND TYPE VARIATIONAL PRINCIPLE ON GAUGE SPACES WITH APPLICATIONS TO FIXED POINT THEORY, DROP THEORY AND COERCIVITY

  • Bae, Jong-Sook;Cho, Seong-Hoon;Kim, Jeong-Jin
    • Bulletin of the Korean Mathematical Society
    • /
    • v.48 no.5
    • /
    • pp.1023-1032
    • /
    • 2011
  • In this paper, a new Ekeland type variational principle on gauge spaces is established. As applications, we give Caristi-Kirk type fixed point theorems on gauge spaces, and Dane$\check{s}$' drop theorem on seminormed spaces. Also, we show that the Palais-Smale condition implies coercivity on semi-normed spaces.

On Strict Stationarity of Nonlinear Time Series Models without Irreducibility or Continuity Condition

  • Lee, Oe-Sook;Kim, Kyung-Hwa
    • Journal of the Korean Data and Information Science Society
    • /
    • v.18 no.1
    • /
    • pp.211-218
    • /
    • 2007
  • Nonlinear ARMA model $X_n\;=\;h(X_{n-1},{\cdots},X_{n-p},e_{n-1},{\cdots},e_{n-p})+e_n$ is considered and easy-to-check sufficient condition for strict stationarity of {$X_n$} without some irreducibility or continuity assumption is given. Threshold ARMA(p, q) and momentum threshold ARMA(p, q) models are examined as special cases.

  • PDF