• Title/Summary/Keyword: Condensing

Search Result 407, Processing Time 0.033 seconds

The Comparison of Performance Characteristics in Refrigeration System using $NH_3$ and R22 ($NH_3$와 R22를 사용한 냉동장치의 성능특성 비교)

  • Ha Ok-Nam;Lee Kyu-Tae;Ha Kyung-Soo;Jeong Song-Tae;Kim Jin-Hyun;Hong Seong-In;Yun Kab-Sig;Kim Yang-Hyun;Kwon Il-Wook;Lee Jong-In
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.377-383
    • /
    • 2006
  • Recently, production and use of Freon substances are restrained due to destruction of ozone layer and grobal warming. In this aspect of environmental problems, the best solution is to use the natural refrigerant such as ammonia. Thus, this study apply the $NH_3$ and R22 to study the performance characteristic from the superheat control and compare the energy efficiency of two refrigerants from the high performance. The condensing pressure of refrigeration system is increased from 1,500 kPa to 1,600 kPa and degree of superheat is increased from 0 to $10^{\circ}C$ at each condensing pressure. As the result of experiment, when comparing the each COP, we knew the $NH_3$ is suitable as the alternative refrigerant of the R22.

A Study on Performance Characteristics due to the Degree of Superheat in Freon Refrigerating System - The Comparison of Heat Exchanger Types - (프레온 냉동장치의 과열도에 관한 성능 특성 연구 - 열교환기 타입별 비교 -)

  • Hong, Suck-Joo;Ha, Ok-Nam;Kwon, Il-Wook;Yun, Kab-Sig;Hong, Sung-In;Kim, Jin-Hyun;Kim, Yang-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.941-946
    • /
    • 2006
  • Nowadays heat exchangers that have been applied for freon refrigerating systems, a shell and tube type condenser, but because of their large size, large space for installation and more amount of refrigerants are needed. Therefore, in this study, we will find the most suitable operating condition through the comparison of performance between the shell & tube type and shell & disk type heat exchanger with R22. The experiments are carried out for the condensing pressure of refrigeration system from 1,500 kPa to 1,600 kPa and for the degree of superheat from 0 to $10^{\circ}C$ at each condensing pressure. As a result of experiment, if the shell & disk type heat exchanger is applied for R22 refrigerating systems, minimized input of refrigerants and space required for installation will be secured, which will have a great contribute to financial improvement for industry.

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

Spatial Evolution and Characteristics of Cultural Tourism Festivals in Chonnam Province of Korea (전남지역 문화관광축제의 공간적 전개과정과 특징)

  • Lee, Jeong-Rock;Woo, Youn-Sub
    • Journal of the Korean association of regional geographers
    • /
    • v.9 no.3
    • /
    • pp.233-247
    • /
    • 2003
  • The purpose of this study focuses on the spatial evolution and characteristics of cultural tourism festivals in Chonnam province of Korea. More than 58 community festivals functioned with hallmark events are held annually in the Chonnam province. Most of community festivals were mainly established since 1995, and more than 48 percents of festivals are held in October and May. Spatial diffusion process of festival are divided into three phases: a primary stage before 1995, a diffusion stage from 1995 to 1999, and a condensing stage since 2000 Cultural tourism festivals began at some areas such as Mokpo, Yesu, and Gurye in 1960's, and spread all over the counties of Chonnam province. During diffusion stage, 51.7 percent of all festivals were newly held. The themes and purposes of festival, and the typology of community festivals were transformed with diffusion stage. In festival purpose, community reconciliation and unity festivals were held in primary stage, tourism oriented festivals were held in diffusion and condensing stage. In the festival themes, community culture and folk arts festival were held in primary stage, however, community history and environment & ecological festivals are held in condensing stage. In addition, the typology of community festivals was transformed according to diffusion stage. Thus it was transformed from indigenous festivals of primary stage to commercialized indigenous festivals of condensing stage.

  • PDF

pH, Alkaline Earth Metal Ion Effects and Miscibility with Hexadecanol on the Monolayer of Palmitic Acid at the Air-Water Interface (기-액 계면에서 Palmitic Acid 단분자막에 대한 pH, 알칼리토금속 이온의 영향 및 Hexadecanol 분자와의 섞임성)

  • Jong-Jae Chung;Byung-Il Seo;Hai-Won Lee;Min-Young Ju
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.3
    • /
    • pp.294-301
    • /
    • 1993
  • ${\pi}$-A isotherms of the Palmitic acid(PA) with increasing pH shifted to the low area/molecule due to the dissociation of PA at the air-water interface. More condensation of PA monolayers occurred by the addition of Mg$^{2+}$, Ca$^{2+}$ and Ba$^{2+}$ ion in subphase. This condensing effect was increased with increasing the concentration of these ions. Due to the interaction with each ion, PA were formed Mg, Ca, Ba-Palmitate complex. The binding structure between alkaline earth ion and carboxylate ligand in PA has been identified by IR spectrometry. The order of condensing effect of alkaline earth ions at pH 8 was Ca$^{2+}$ > Ba$^{2+}$+ > Mg$^{2+}$. The condensing effect except for Mg$^{2+}$ decreased with increasing atomic number. Whereas, the condensing effect in pure water system decreased with decreasing atomic number in the sequence: Ba$^{2+}$ > Ca$^{2+}$ > Mg$^{2+}$. The miscibility of binary system of PA and hexadecanol in monolayer showed that the miscibility was good for the pure water system. But, in the buffered pH 8 system, bad miscibility was found.

  • PDF

An Experimental Study on Condensation Heat Transfer of Low-Finned Tubes (낮은 핀관 (low-fin tube)의 응축 열전달 성능에 관한 실험적 연구)

  • Kim, N.H.;Jung, I.K.;Kim, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.298-309
    • /
    • 1995
  • Low-fin tubes are widely used to enhance condensation heat transfer. In this study, condensation heat transfer experiment was conducted on the low-fin tube using R-11. Three different fin densities-787 fpm (fins per meter), 1102 fpm. 1378 fpm-were tested. The results show that low-fin tube enhances the condensation heat transfer considerablely. The enhancement increases as the fin density increases. It was also found that the fin shape and height have a significant effect on the condensation heat transfer coefficient. Slender or high fins showed a higher condensing heat transfer coefficient compared with fat, low fins. For the tube with 1378 fpm, however, excessive fin height decreased the condensing heat transfer coefficient. The reason may be attributed to the increasing condensate retention angle as the fin density increases. The experimental data are compared with existing prediction models. Results show that Webb's surface tension model predicted the data best (within ${\pm}20%$), which confirms that surface tension plays the major role in low-fin tube condensation.

  • PDF

ANALYSIS ON STEAM CONDENSING FLOW USING NON-EQUILIBRIUM WET-STEAM MODEL (비평형 습증기 모델을 적용한 증기 응축 유동 해석)

  • Kim, C.H.;Park, J.H.;Ko, D.G.;Kim, D.I.;Kim, Y.S.;Baek, J.H.
    • Journal of computational fluids engineering
    • /
    • v.20 no.3
    • /
    • pp.1-7
    • /
    • 2015
  • When the steam is used as working fluid in fluid machinery, different from other gases as air, phase transition (steam condensation) can occur and it affects not only the flow fields, but also machine performance & efficiency. Therefore, considering phase transition phenomena in CFD calculation is required to achieve accurate prediction of steam flow and non-equilibrium wet-steam model is needed to simulate realistic steam condensing flow. In this research, non-equilibrium wet-steam model is implemented on in-house code(T-Flow), the flow fields including phase transition phenomena in convergent-divergent nozzle are studied and compared to results of advance researches.

Characterization of Carbon Black and Oil from Positive Process of movable disc type for Waste Tires Pyrolysis (디스크 이동식 폐타이어 열분해 실증 설비로부터 생성된 Carbon Black, Oil의 특성 분석)

  • Ha, Hyun-Jung;Kim, Seong-Yeon;Kim, Ki-Kyeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.483-486
    • /
    • 2008
  • 본 연구에서는 디스크 이동식 열분해 실증 설비를 이용하여 폐타이어 열분해 반응을 수행하였고, 생성된 열분해 생성물들의 특성을 분석하였다. 폐타이어 열분해 반응은 약 $550^{\circ}C$에서 90분간 진행되었고, 반응 결과 Recovered Oil, Carbon Black, Non Condensing Gas(NC Gas)가 생성되었다. 폐타이어 열분해 생성물의 수율은 Recovered Oil $40{\sim}50%$, Carbon Black 30$\sim$35%, NC Gas 10$\sim$15%, Steel 10$\sim$15%로 나타났다. 폐타이어 열분해 반응 후 생성된 Recovered Oil은 비점 및 특성 분석 결과 상업용 중유와 비슷한 성질을 나타냈고, 폐타이어 열분해 반응의 또 다른 생성물인 Carbon Black은 특성 분석 결과 고정 탄소 비율이 낮은 반면 회분과 휘발분의 비율이 높아 상업용으로 사용하기 위해서는 적절한 정제 과정이 필요함을 알 수 있었다.열분해 과정 중에 생성된NC Gas는 GC/MS를 이용하여 성분 분석을 수행한 결과, $CO_2$, $CH_4$를 비롯하여 주로 탄화수소류로 이루어졌으며, 대부분이 연료 가스로 구성되어 있어 열분해 반응의 열원으로서 사용이 가능하였다.

  • PDF