• 제목/요약/키워드: Condensation Prevention

검색결과 46건 처리시간 0.025초

시뮬레이션을 통한 바닥복사냉방 시스템의 공급유량 및 냉수온도 제어에 관한 연구 (A Study on the Control of Water Flow and Water Temperature in the Radiant Cooling System through Simulations)

  • 김용이;윤혜림;여명석
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.532-540
    • /
    • 2001
  • The objectives of this study are to analyze the control variables according to condensation occurrence, to find the range in floor surface temperature and frequency of condensation, and to evaluate the control methods through simulations when the radiant heating system is used for cooling. Through the simulation analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The results show that the lowest floor surface temperature is around $23^{\circ}C$, the surface condensation can be prevented by controlling indoor humidity within 20g/kg(DA0, and that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

화물선의 결로 방지에 대한 연구 (A Study on the Condensation Prevention of Bulk Carrier)

  • 오세진;김원욱;김성환;이성근;김종수
    • 해양환경안전학회지
    • /
    • 제17권4호
    • /
    • pp.429-434
    • /
    • 2011
  • 선박에 적재된 곡류, 철강재 등의 산적화물에 여러 가지 이유로 손상이 발생될 수 있다. 본 논문에서는 코일 운반선의 화물손상 원인 중 특히, 결로에 의한 손상과 그에 대한 방지대책에 대해 분석하고자 한다. 결로란 주위 온도가 이슬점 이하로 떨어져 물체 표면에 공기 중의 수증기가 물방울로 맺히는 현상을 말하며 일반적으로 실내외 온도차가 큰 건축물이나 선박의 화물창에서 많이 발생한다. 특히, 비슷한 시기에 기온차가 있는 전 세계를 운항하는 선박에서 흔히 발생할 수 있는 현상이다. 본 연구에서는 코일 운반선의 결로에 의한 화물손상 방지 대책에 대해 고찰하고 화물손상을 방지하기 위해 제습장치와 가열온풍장치를 병용하는 새로운 방법의 제안과 습도, 습기량, 제습장치 용량, 결로수량, 화물 및 공기와 외기의 온도 차이에 따른 화물창 내 공기와 화물 가열에 필요한 열량, 가열장치 용량 등의 산정법을 제시한다.

제습기능이 통합된 바닥복사 냉방시스템의 용 가능성에 관한 실험적 연구 (An Experimental Study for Evaluating Performance of Radiant Floor Cooling System Integrated with Dehumidification)

  • 이상엽;황석호;김가현;이승복
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.143-152
    • /
    • 2002
  • It is critical for radiant floor cooling system using Ondol to cause condensation on a floor surface. To solve this problem, a radiant floor cooling system integrated with dehumidification was proposed and evaluated in terms of its applicability and prevention of condensation. Therresults show that the proposed system of radiant floor cooling integrated with dehumidification properly maintained the indoor setpoint temperatures and prevented the condensation on a floor surface. To achieve more stable indoor temperatures and humidity control, a further study for the operation of dehumidification panel will be needed.

근광충전방법에 따른 post space형성후의 근관폐쇄성에 관한 실험적 연구 (CORONAL DYE PENETRATION OF THE APICAL FILLING MATERIALS AFTER POST SPACE PREPARATION)

  • 윤수한;권오양
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.812-817
    • /
    • 1995
  • Endodontically treated teeth are usually restored for crown protection, aesthetics, and prevention of root canal recontamination. Restoration of these teeth, however, often requires intracanal posts. Various depths and techniques have been recommended for the preparation of post space. Therefore the purpose of this study was to evaluate the effect that pst preparation has on the coronal seal by linear dye penetration of root canals obturated by lateral condensation, vertical condensation, and thermafil techniques. Forty canals of roots of incisors and canines were cleaned and shaped with the use of a step-back technique. Thirty canals were obturated, 10 each with lateral, vertical, and thermafil techhniques. Five root canals were obturated without a root canal sealer and served as positive controls. Another five root canals were obturated, and their coronal half was sealed with sticky wax and served as negative controls. The apical 5 to 6mm of the filling materials were exposed to india ink for 48 hours. The depth of dye penetration was measured in all groups and statistically analyzed (ANOVA). The results were as follows. 1. The apical plugs in the thermafil groups had the highest degree of coronal dye leakage. 2. The group filled by vertical condensation technique had the lowest degree of coronal dye leakage. 3. No significant statistical difference was found in the amount of coronal dye leakage in canals filled by lateral condensation versus those filled by the veritcal condensation technique. 4. Significant statistical differences in coronal dye penetration were found between the canals filled by thermafil and those filled by the lateral or vertical condensation techniques (p<0.05).

  • PDF

열펌프를 이용한 슬러리 돈분뇨 증발건조처리시스템 개발 (Development of Heat Pump Use Slurry Pig Manure Evaporation Drying System)

  • 김현태;최홍림
    • Journal of Biosystems Engineering
    • /
    • 제30권1호
    • /
    • pp.32-37
    • /
    • 2005
  • This study was conducted the slurry pig manure treatment by condensation drying of liquid from the slurry manure with a heat-pump and electric heater combined with air flow channel system. The system was designed as liquid and solid matters separation of slurry manure, and it can doing continuous input of slurry manure from a pig house, and it can operated year round use for pig farms. The separation of liquid and solid matters from slurry manure needed the prevention of solid accumulation in the system. The system was designed as closed space from outside air space for maximized evaporation of liquid and the condensation of liquid from slurry manure. The system can be operated the pig slurry manure treatment regardless of seasons in a yew. The separated evaporation water from the pig slurry manure by the heat-pump was satisfactorily pure water that can be used as washing water in livestock farms. The system can applicate to about 100 heads of pig, and the proper area of evaporation plate system was considered around $10\;m^2$. The input electrical energy of about 15 kWh which the cost equal to 250,000 won per month.

동절기 2중버블시트로 단열처리된 옹벽의 온도이력 특성 (Temperature History of the Concrete for Retaining Wall Insulated with Double Layered Bubble Sheet in Winter)

  • 정은봉;손호정;장덕배;경영혁;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.269-270
    • /
    • 2012
  • This study discussed the applicability of double layered bubble sheet(BS) to the concrete for retaining wall to verify the insulation effect as well as prevention of condensation. The BS was applied to the surface of retaining wall, which is contacted with ground. Temperature profile was monitored since placement of concrete. As expected, the application of BS helps the concrete keeping favorable heat insulating, preventing condensation.

  • PDF

EXPLOSION HAZARDS IN TANKS OF HIGH FLASH POINT LIQUIDS

  • Zalosh, Robert
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.203-210
    • /
    • 1997
  • Reports of explosions in cargo and storage tanks of high flash point liquids such as residual fuel oil, asphalt, and oily waste water have shown that these explosions have occurred even when the liquid temperatures are well below the liquid nominal flash point. The reasons for these seemingly paradoxical explosions are reviewed and results of recent laboratory tests are presented to better define the conditions leading to flammable vapor atmospheres in these tanks. The potential effectiveness of various prevention measures are discussed including inerting, monitoring tank vapor concentrations, and periodic cleaning of condensation and deposits on the tank walls and roof.

  • PDF

실측실험과 3차원 정상상태 열전달 해석을 통한 발열유리의 온도 및 전열량 분석 (Analysis of Temperature and Total Heat of Heated Glass through Experimental Measurement and Three-Dimensional Steady-State Heat Transfer Analysis)

  • 이도형;윤종호;오명환
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.111-116
    • /
    • 2015
  • Heat loss from windows and condensation occuring on its surface due to its lower insulation value causes much discomfort to occupants. In this study, Heated glass was used to make a basic study on prevention of condensation on glass surface for its heating functionality through experimental measurement and simulation analysis of total heat flux on the interior and exterior surface of glass. Error between experimental results and three dimensional steady-state heat transfer analysis were caused firstly, beacuse in the experimental chambers, cold chamber and steady temperature and humidity chamber, air temperature setting was not constant but rather ON/OFF control, and secondly, due to error rate in heat flux meter due to heat flux direction even in stable conditions.

컨테이너형 ESS 화재방지를 위한 내부 응결점 개선 관한 연구 (Study on Improvement of Dew Point within ESS Container for Fire Prevention)

  • 김운학;강석원;신기석
    • 한국재난정보학회 논문집
    • /
    • 제15권2호
    • /
    • pp.165-174
    • /
    • 2019
  • 연구목적: 본 연구에서는 제안되는 ESS 컨테이너 화재사고의 원인들에 대한 상관관계를 확인하였다. 연구방법: 이들의 개선에 필요한 컨테이너 내부의 환경개선을 통하여 컨테이너 화재사고의 저감 가능성에 대한 조사를 시행하였다. 연구결과: 본 연구를 통해 내 외부 온도차에 발생되는 수분응결 조건의 개선과 이를 통한 BMS board의 절연 내력의 변화가 있음을 확인하였다. 연구결론: BMS Board 응결과 절연 내력저하와의 상관 관계를 확인하였다.

이층커튼 온풍난방 플라스틱온실의 겨울철 포차 및 결로량 변화 (Variation of Vapor Pressure Deficit and Condensation Flux of Air Heating Plastic Greenhouse Installed with Two Layers Thermal Curtain in Winter)

  • 이현우;김영식;심상연;이종원
    • 생물환경조절학회지
    • /
    • 제22권1호
    • /
    • pp.35-41
    • /
    • 2013
  • 본 연구는 우리나라 온실 피복재의 결로 발생을 억제하는데 필요한 기초자료를 제공하기 위하여 토마토 재배용 실험온실의 포차변화 및 피복재에 발생하는 결로량의 변화를 분석하였으며 결과를 요약하면 다음과 같다. 실험온실의 경우 포차가 병 발생을 유발하기 쉬운 한계포차인 0.2kPa보다 더 크게 유지되어 온습도환경이 양호한 것으로 판단되었고 제습여부 결정을 위한 임계포차인 0.5kPa보다는 작게 나타나 제습은 필요한 것으로 판단되었다. 내부피복재의 표면온도는 외부온도와 커튼상부온도의 평균값 보다 약간 더 큰 것으로 나타났으며, 대체로 외부온도의 변화에 비례하여 변화하는 것으로 나타났다. 외부의 온도 및 습도 변화에 상관없이 커튼 상부의 습도는 거의 100%에 가까운 상대습도를 유지하여 결로 발생이 용이한 조건인 것으로 나타났다. 커튼하부의 습도는 내부습도의 큰 변화에도 불구하고 75~90% 정도로 안정된 값을 유지하였으며, 이는 온풍난방을 실시하여 온도를 $15^{\circ}C$로 유지하였기 때문으로 판단된다. 실험조건 및 피복재의 종류에 따라 결로 발생량은 많은 차이가 있는 것으로 알려져 있다. 실험온실의 결로 발생량은 Seginer와 Kantz(1986)의 연구결과와 가장 잘 일치하는 것으로 나타났으나 다른 온실실험 결과들과는 약간의 차이를 보여주고 있기 때문에 앞으로 실험을 통해서 더 자세한 검증을 거친다면 우리나라 온실 피복재에 발생하는 결로량을 분석하는데 유용하게 활용될 수 있을 것으로 기대된다.