• Title/Summary/Keyword: Condensate

Search Result 190, Processing Time 0.028 seconds

Protein Removal by a Foam Fractionator in Simulated Seawater Aquaculture System

  • Peng, Lei;Oh, Sung-Yong;Jo, Jae-Yoon
    • Ocean and Polar Research
    • /
    • 제25권3호
    • /
    • pp.269-275
    • /
    • 2003
  • Effects of different operating factors including superficial air velocity (SAV), hydraulic residence time (HRT), protein concentration, and foam overflow height on protein removal by a foam fractionator in simulated seawater aquaculture system were investigated. This experiment was conducted on batch and consecutive modes at different combinations of the affecting factors. The foam fractionator had a diameter of 20cm and a height of 120cm and the experiment was conducted with synthetic wastewater. In 5 consecutive trials, protein concentrations in culture tank water decreased faster when the foam fractionator was operated at higher SAVs and lower HRTs. In batch trials, protein removal rates increased with an increase in SAV but decreased with an increase in URT. Higher protein concentrations in the bulk solution resulted in higher protein removal rates. Protein concentrations in the collected foam condensates increased but the foam overflow rates decreased with the increase of foam overflow heights. The results of this experiment indicate that foam fractionation would be an effective way for protein removal in seawater aquaculture systems and the performance of the foam fractionator depends largely on the operating parameters, especially SAV.

일체형 원자로의 공랭식 열교환기 개념 연구 (A Conceptual Study of an Air-cooled Heat Exchanger for an Integral Reactor)

  • 문주형;김우식;김영인;김명준;이희준
    • 한국유체기계학회 논문집
    • /
    • 제19권2호
    • /
    • pp.49-54
    • /
    • 2016
  • A conceptual study of an air-cooled heat exchanger is conducted to achieve the long-term passive cooling of an integral reactor. A newly designed air-cooled heat exchanger is introduced in the present study and preliminary thermal sizing is demonstrated. This study mainly focuses on feasibility of an innovative air-cooled heat exchanger to extend the cooling period of the passive residual heat removal system(PRHRS) only in passive manners. A vertical shell-and-tube air-cooled heat exchanger is installed at the top of the emergency cooldown tank(ECT) to collect evaporated steam into condensate, which enables water inventory of the ECT to be kept. Finally, thermal sizing of an air-cooled heat exchanger is presented. The length and the number of tubes required, and also the height of a stack are calculated to remove the designated heat duty. The present study will contribute to an enhancement of the passive safety system of an integral reactor.

원전 급수가열기 동체 응력 해석 (A Stress Analysis of Feeedwater Heater Shell in Nuclear Power Plant)

  • 송석윤;김형남
    • 한국압력기기공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.1-11
    • /
    • 2015
  • Feedwater Heaters are important components in a nuclear power plant. As the age of heater increases, the maintenance cost required for continuous operation also increases. Most heaters have the carbon steel shells, tube support plates and flow baffles. The carbon steel is susceptible to flow-accelerated corrosion. This is especially true if the flow has a two-phase mixture of steam and condensate. The wall thinning around the wet steam entrance area of the shell is inevitable during some long term operation. The structural integrity of the feedwater heater shell affects the safe operation of the nuclear power plant. Therefore, it is needed for the thinned shell to be repaired. The maintenance method for preventing failure of the shell should be determined by investigating various factors including the stress distribution of thinned area. The stress analysis of the shell including the steam entrance region is studied in this paper. The results of thinned shell is compared with that of intact shell.

전자스핀공명에 의한 담배연기 중 자유라디칼 측정 (Determination of Free Radicals in Mainstream Cigarette Smoke by Electron Spin Resonance)

  • 이정민;이존태;박진원;황건중
    • 한국연초학회지
    • /
    • 제29권2호
    • /
    • pp.146-151
    • /
    • 2007
  • Gas phase and particulate phase radicals in mainstream cigarette smoke were determined Electron Spin Resonance(ESR) spectroscopy. The free radicals in particulate phase have been investigated by benzene extract of Cambridge Filter Pad containing the smoke condensate. Spin trapping method in conjunction with ESR was used to investigate free radicals in the gas phase of cigarette smoke. Several analytical experiments were conducted in order to determine the optimal conditions for maximum signal intensities and reproducibility of results. All the tests were optimized and normalized using the University of Kentucky 2R4F reference cigarette. The optimal conditions were 0.6 mL for analysis volume of ESR, $4{\sim}5\;mL$ for collection volume of spin-adducts, and PBN for quantification of free radicals in gas phase. The radical levels of Kentucky 2R4F cigarettes were found $2.18{\times}10^{14}\;spins/cig.$ and $2.10{\times}10^{15}\;spins/cig.$ in gas phase.

A Study on the High-Flowing Concrete with Low Unit Weight of Cement

  • Si Woo Lee;Hong Shik Choi;Sang Chel Kim;Gweon Heo
    • The Korean Journal of Ceramics
    • /
    • 제6권3호
    • /
    • pp.318-321
    • /
    • 2000
  • Most compressive strengths commonly used in the construction field are in a range of 240 to 300 kgf/$\textrm{cm}^2$ at 28 days. To get this rage of strengths, however, high-flowing concrete requires cementitious binders more than 400 to 450 kg/$\textrm{cm}^2$ for preventing segregation and sedimentation of aggregates. This amount of cementitious binder generates a large emission of excessive hydration heat, which may consequently induce harmful cracks in concrete structure. In order to reduce excessive hydration heat, thus, this paper aims at fabricating a high-flowing concrete under the condition that cement content is kept as low as 350kg/$\textrm{cm}^3$ by using viscose agents. In a parametric study, effects of cement types such as a ternary blended cement and Type V on he physical characteristics of high-flowing concrete were evaluated. In addition, the influence of viscosity was also investigated by applying two different viscose agents, one in a range of 6,000 to 10,000 cps and the others of 10,000 to 14,000 cps. In terms of chemical admixtures used in concrete mixture, the superplasticizer was Sulfonated Melamine-Formaldehyde Condensate with about 30,000 of molecular weight, and main component of viscose agent was HPMC (Hydroxy Propyl Methyl Cellulose). Slump flow was fixed at 50cm with different dosages of superplasticizer in weight.

  • PDF

Monitoring of the Content of Imidazoline-Containing Corrosion Inhibitor

  • Zadorozhny, P.A.;Sukhoverkhov, S.V.;Markin, A.N.;Savin, K.I.;Prokuda, N.A.
    • Corrosion Science and Technology
    • /
    • 제16권4호
    • /
    • pp.161-166
    • /
    • 2017
  • The qualitative composition of active components of the corrosion inhibitor CGW-85567 was studied. It was found that С18:2 and С18:1 imidazolines and the corresponding imidazolin-amides are the major components. The HPLC/MS technique was developed for their determination in the water solutions of monoethylene glycol (MEG). Industrial application of the inhibitor showed that MEG solution retained high concentration of the inhibitor for a long time after ceasing its addition into pipelines. Low values of the partition coefficients (0.010-0.014) of imidazolines in the system "water solution of MEG (concentration of MEG 62-85% v/v) - gas condensate" have allowed to pass on from the technology of continuous pumping of the inhibitor into protected pipelines to the periodic dosing technology. Taking into account a long time of circulation in the system and high temperatures during MEG regeneration process possible degradation products of the inhibitor were studied. N, N-dimethyl-dodecanamine-1, and N, N-dimethyl-tetradecanamine-1 were identified as major degradation products of the corrosion inhibitor CGW-85567.

Application of Flow Network Models of SINDA/FLUIN $T^{TM}$ to a Nuclear Power Plant System Thermal Hydraulic Code

  • Chung, Ji-Bum;Park, Jong-Woon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.641-646
    • /
    • 1998
  • In order to enhance the dynamic and interactive simulation capability of a system thermal hydraulic code for nuclear power plant, applicability of flow network models in SINDA/FLUIN $T^{™}$ has been tested by modeling feedwater system and coupling to DSNP which is one of a system thermal hydraulic simulation code for a pressurized heavy water reactor. The feedwater system is selected since it is one of the most important balance of plant systems with a potential to greatly affect the behavior of nuclear steam supply system. The flow network model of this feedwater system consists of condenser, condensate pumps, low and high pressure heaters, deaerator, feedwater pumps, and control valves. This complicated flow network is modeled and coupled to DSNP and it is tested for several normal and abnormal transient conditions such turbine load maneuvering, turbine trip, and loss of class IV power. The results show reasonable behavior of the coupled code and also gives a good dynamic and interactive simulation capabilities for the several mild transient conditions. It has been found that coupling system thermal hydraulic code with a flow network code is a proper way of upgrading simulation capability of DSNP to mature nuclear plant analyzer (NPA).

  • PDF

수평 원형전열관의 핀효과에 의한 응축 및 비등 열전달촉진에 관한 연구 (2)-튜브외부 응축- (A Study on the Improement of Condensation and Boiling Heat Transfer on Horizontal Tube by Fin Effect(ll)-Shellside Condensation-)

  • 한규일;조동현
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1275-1287
    • /
    • 1994
  • Heat transfer performance improvement by fin and grooves is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapezoidal shaped integral-fins having fin densities from 748 to 1654 fpm and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also tested for comparison. R-11 condenses at saturation state of $32^{\circ}C$ on the outside tube surface cooled by inside water flow. All of test data ate taken at steady state. Beatty and Katz's, Rudy's and Webb's theoretical models are used to predict the R-11 condensation coefficient of tubes having 748, 1024 and 1299 fpm. The predicted value by Betty and Katz's model is within 10% of experimental values in this study at fpm<1024 and Rudy's model predicted the experimental data at fpm>1024 within 15%. The tube having fin density of 1299 fpm and 30 grooves has the best overall heat transfer performance. This tube shows the overall heat transfer coefficient of 11500 $W/m^{2}K$,/TEX> at coolant velocity of 3.0m/s.

담배연기 농축액 처리에 의해 유도된 사람 기관지 상피세포주의 Hypoxia-Reoxygenation에 대한 민감성 (Susceptibility of Cigarette Smoke Condensate-Exposed Human Bronchial Epithelial Cells to Hypoxia-Reoxygenation)

  • 이인자;최은미
    • Environmental Analysis Health and Toxicology
    • /
    • 제24권1호
    • /
    • pp.53-61
    • /
    • 2009
  • 사람 기관지상피세포주인 BEAS-2B에 담배연기농축액(CSC)을 처리하여 유도된 1198 세포주는 대조군 세포주인 1799에 비해 현저하게 낮은 glutathione 농도와 낮은 glutamate-cysteine ligase(GCL), glutathione peroxidase(GPx), glucose-6-phosphate dehydrogenase(G6PD), catalase 효소활성을 보였다. 두 세포주를 포도당 존재 하에서 4시간 hypoxia 처리 후 reoxygenation 하면서 시간에 따른 세포의 항산화계 활성을 측정한 결과, 1799 세포주에서는 의미 있는 변화가 관찰되지 않은 반면, 1198 세포주에서는 hypoxia 처리에 의해 glutathione의 농도 및 GSH/GSSG 비와 G6PD 활성이 감소되었고, reoxygenation 기에는 GPx, glutathione reductase(GRd), G6PD, superoxide dismutase 활성이 감소되었다. 그러나 reoxygenation 2시간 이후에는 GRd와 G6PD 활성의 회복이 관찰되었으며, 그 결과 GSH/GSSG 비율이 회복되었다. 이 실험 결과는 CSC가 능력을 현저히 저하시킬 수 있음을 보여준다. Glutathione은 hypoxia-reoxygenation에 의한 산화적 스트레스 하에서 항산화제로서의 역할뿐 아니라, 세포 내 GSH/GSSG 비의 변화를 통해 산화적 스트레스에 대한 항산화계의 적응 반응 여부를 결정하는 중요한 인자로 작용할 것으로 보여진다.

제지공정 건조 실린더의 모델링 및 모사 (Modeling and Simulation of Drying Cylinders in Paper Processes)

  • 이은호;곽기영;여영구
    • Korean Chemical Engineering Research
    • /
    • 제45권1호
    • /
    • pp.17-24
    • /
    • 2007
  • 본 연구의 목적은 제지공정에서 건조 실린더의 모델을 규명하고 입력변수들에 대한 공정의 응답 특성을 분석하는 것이다. 모델의 규명은 실제 공장의 운전 데이터에 근거하였는데 건조공정에서는 실린더로 공급되는 수증기의 압력이 주요 변수가 된다. 수증기 응축액으로부터 캔버스로의 열전달 계수는 실린더 및 웹과 펄프의 열 전도도와 운전 데이터에 근거하는 실험식으로 나타낼 수 있음이 밝혀졌다. 실린더 모델은 측정되는 수분함량과 웹 온도를 이용하여 검증하였으며 건조 공정의 안정성은 실린더 모델로부터 얻은 전달함수로부터 확인하였다.