• Title/Summary/Keyword: Concrete repair

Search Result 808, Processing Time 0.026 seconds

Structural Characteristics of Reinforced Concrete Beam-Column Joints Repaired and Restrengthening (재보수-보강된 철근콘크리트 보-기둥 접합부의 구조특성)

  • Cho, Chang-Ho;Kim, Jeong-Sup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.231-238
    • /
    • 2003
  • Reinforced concrete buildings damaged by earthquake which can be reused can ensure the stability in its structure by repair-restrengthening, but when such a repair-restrengthening is conducted inappropriately or its structural strength is greatly reduced by earthquake again, it should have repair-restrengthening. This study selects beam-column joints which are vulnerable to earthquake as the object of experiment, performs repair-restrengthening after applying the first and the second dynamic loading to the objects of experiment, examines the capacity of restrengthening according to structural characteristics and loading velocity and verifys the validity of repair-restrengthening.

A Study on the Evaluation of Deterioration Properties of Reinforced Concrete Applied Repair Material and Method System by Long Term Exposure Experiment (장기폭로실험에 의한 철근콘크리트 보수재료공법 시스템의 열화특성 평가에 관한 연구)

  • Choi, Hyeong-Gil;Shin, Kwan-Soo;Shin, Seung-Bong;Na, Chul-Sung;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.129-132
    • /
    • 2007
  • In this study, for the establishment of the performance evaluation methods of repair material and method for reinforced concrete structure and the quality control standards of durability recovery method, the quantitative exposure data by exposure experiment under the coastal and normal atmosphere environment is accumulated and analyzed. Investigating and evaluating the result of exposure experiment during 54 months of exposure age under the coastal and normal atmosphere environment, Micro crack, swelling and spatting of surface coating material, crack of repair boundary parts and the great potential difference between repair part and non-repair part were somewhat generated. And the result shown that exposure specimen of coastal environment had lower electrode potential than exposure specimen of normal atmosphere environment.

  • PDF

An Experimental Study for Establishment of On-Site Quality Control of Repair Material by the mechanized construction (기계화시공에 의한 보수재료의 현장품질관리확립을 위한 실험적 연구)

  • Cho Bong Suk;Jang Jae Bong;Kim Yong Ro;Kang Suk Pyo;Hong Sung Yun;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.160-163
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation, chemical decay et. developed and applied. However, on-site quality control of various repair materials and method systems isn't achieved desirably because it is depend completely on a men of experience' opinions above all else regardless of various on-site environments. In this background, mock up test with due regard to real on-site environments was performed to secure fundamental data for establishment of desirable on-site quality control. Mock up test using repair mortar analyzed from angles of construction methods, mechanical spraying pressures, W/M. Construction methods were designed manpower method and spraying method, spraying pressures were designed 32, 42, 52 psi, W/M were designed 14.4, 15.4, $16.4\%$. And compressive strength, Chloride ion diffusion coefficient, bond strength, SEM. of mock up test specimens were evaluated. In conclusion, we confirmed excellency of mechanical spraying pressures, fined extremely excellency of condition of spraying pressure 42 ps, W/M $14.4\%$ within this study. therefore the results of this study will be useful to provide fundamental data for establishment of desirable on-site quality control.

  • PDF

A Study on the Corrosion Properties of Reinforcing bar and Performance Evaluation of Repair Material and Method for Reinforced Concrete Structure by Exposure Experiment under the Coastal and Normal Atmosphere Environment (해양 및 일반대기환경의 폭로실험에 의한 철근콘크리트구조물 보수재료.공법의 성능평가 및 철근의 부식특성에 관한 연구)

  • Nam Jeong-Soo;Roh Kyung-Min;Shin Seung-Bong;Kim Young-Sun;kim Gyu-Yong;Kim Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.167-171
    • /
    • 2006
  • In this study, for the establishment of the performance evaluation methods of repair material and method for reinforced concrete structure and the quality control standards of durability recovery method, the quantitative exposure data by exposure experiment under the coastal and normal atmosphere environment is accumulated and analyzed. Investigating and evaluating the result of exposure experiment during 30 months of exposure age under the coastal and normal atmosphere environment, carbonation depth and chlorideion penetration depth very little penetrated than cover depth. It seems reasonable to conclude that main cause of corrosion of reinforcing bar are inner chloride-ion and macro cell from the result of corrosion area and corrosion velocity. Accordingly, it is considered that fundamental data on the performance evaluation and quality control standards of repair material and method could be presented through continuous exposure test in the future.

  • PDF

AHP Based-Optimal Selection of Concrete Patching Repair Materials Considering Qualitative Evaluation Criteria (정성적 평가항목을 고려한 콘크리트 보수용 단면복구재료의 AHP 기반 최적선정 모델링)

  • Do, Jeong-Yun;Song, Hun;Soh, Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.965-968
    • /
    • 2008
  • This study is interested in modeling the selection of optimal repair materials in view of the qualitative evaluation. In order to architecting the evaluation model of various repair alternatives, Analytical hierarchy process techniques was applied to this study. It is composed of aesthetics, easy-to-application, economical efficiency, and environment-friendly properties in upper level. Among the qualitative evaluation items, Environment-friendly properties and execution cost included in economical efficiency is highly weighted. It was concluded that the evaluation model by this study is very useful to choose the best alternative among various repair materials.

  • PDF

Investigation of shear transfer mechanisms in repaired damaged concrete columns strengthened with RC jackets

  • Achillopoulou, D.V;Karabinis, A.I
    • Structural Engineering and Mechanics
    • /
    • v.47 no.4
    • /
    • pp.575-598
    • /
    • 2013
  • The study presents the results of an experimental program concerning the shear force transfer between reinforced concrete (RC) jackets and existing columns with damages. In order to investigate the effectiveness of the repair method applied and the contribution of each shear transfer mechanism of the interface. It includes 22 concrete columns (core) (of 24,37MPa concrete strength) with square section (150mm side, 500 mm height and scale 1:2). Ten columns had initial construction damages and twelve were subjected to initial axial load. Sixteen columns have full jacketing at all four faces with 80mm thickness (of 31,7MPa concrete strength) and contain longitudinal bars (of 500MPa nominal strength) and closed stirrups spaced at 25mm, 50mm or 100mm (of 220MPa nominal strength). Fourteen of them contain dowels at the interface between old and new concrete. All columns were subjected to repeated (pseudo-seismic) axial compression with increasing deformation cycles up to failure with or without jacketing. Two load patterns were selected to examine the difference of the behavior of columns. The effects of the initial damages, of the reinforcement of the interface (dowels) and of the confinement generated by the stirrups are investigated through axial- deformation (slip) diagrams and the energy absorbed diagrams. The results indicate that the initial damages affect the total behavior of the column and the capacity of the interface to shear mechanisms and to slip: a) the maximum bearing load of old column is decreased affecting at the same time the loading capacity of the jacketed element, b) suitable repair of initially damaged specimens increases the capacity of the jacketed column to transfer load through the interface.

Field Application of High Strength Concrete by Cement Types Using Maturity (적산온도를 이용한 시멘트 종류별 고강도 콘크리트의 현장 적용성)

  • Kim, Dong Baek
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.472-478
    • /
    • 2020
  • Purpose: The purpose of the study is to help economic and safe construction by accurately predicting the initial strength of high-strength concrete (70MPa) for each type of cement, securing reliability of concrete quality, and drawing accurately the timing of form deformed, tensioning time of PS concrete, and openning of traffic after road repair with maturity. Method: Calculate the maturity by measuring the hydration heat with cement type for each age, and measure the strength of concrete with age to predict the strength corresponding to the any maturity. Result: In estimating the time required for traffic opening in road repair, ASTM C1074 was theoretically estimated at 16.4 hours for high-strength concrete, but in this study, maturity was calculated at 307, 14.4 hours for OPC and maturity at 2700, 34 hours for LHPC and maturity 200, 8 hours for ESPC. Conclusion: The timing of form deformed of structures using high-strength concrete and the opening of traffic of road repair may be much faster than in the case of concrete using OPC below the design basis strength 40MPa applied by ACI Committee 347.

Evaluation of Chemical Resistance Performance of Synthetic Rubber and Cement Based Injection Repair Materials Used in Underground Concrete Structures (지하 콘크리트 구조물에 적용되는 합성고무계 및 시멘트계 주입형 보수재료의 화학 저항성능평가)

  • Kim, Soo-Yeon;Lee, Yeon-Sil;Song, Je-Young;Kim, Byoungil;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.148-155
    • /
    • 2017
  • In this study, by using the international standards ISO TS 16774, Part 2 Test method for chemical resistance as a quality control method of injection type repair material used for leakage crack of underground concrete structure, the performance requirement against of chemical environment of underground concrete structures for repair materials was tested. For this testing 3 types for each of the 2 classes of repair materials(synthetic rubber, cement), with a total of 9 types repair materials, were selected and examined. As a result, the test results showed that the smallest performance deterioration by the change in the mass was with the synthetic rubber(RG) type as opposed to the cement type system, showing that the synthetic rubber type had the strongest relative resistance to chemical exposure. Furthermore, it is necessary to investigate the material with high resistance to chemical substances and to examine the material which can increase resistance to sodium hydroxide and sodium chloride in cement system. These results can be used as a basic index for the selection of repair materials with the strongest resistance to chemical environment found in concrete structures. In addition, it is expected that the test results derived in this study can be used as reference data that can be reflected in the quality improvement of the maintenance material to be developed later.