• 제목/요약/키워드: Concrete confinement

검색결과 650건 처리시간 0.024초

횡방향 구속철근비에 따른 교각요소부재의 응력-변형 거동 (Stress-Strain Behavior of Confined Concrete Columns according to Transverse Reinforcement Volumetric Ratio)

  • 오병환;김기완;최승원;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.37-40
    • /
    • 2004
  • An experimental study was conducted to investigate the stress-strain behavior of confined concrete columns according to transverse reinforcement volumetric ratio. Uniaxial loading tests of eleven column specimens$(250\times100\times500mm)$ with rectangular section were conducted to study effect of confinement. The main variables in this test are transverse reinforcement volumetric ratio and cross tie arrangement. the results indicate that the strength and the ductility of confined concrete columns are subjected to transverse reinforcement volumetric ration and cross tie arrangement.

  • PDF

Seismic performance of RC bridge piers subjected to moderate earthquakes

  • Chung, Young Soo;Park, Chang Kyu;Lee, Dae Hyoung
    • Structural Engineering and Mechanics
    • /
    • 제24권4호
    • /
    • pp.429-446
    • /
    • 2006
  • Experimental investigation was conducted to evaluate the seismic ductility of earthquake-experienced concrete columns with an aspect ratio of 2.5. Eight circular concrete columns with a diameter of 600 mm were constructed with three test parameters: confinement ratio, lap-splice of longitudinal bars, and retrofitting with Fiber Reinforced Polymer (FRP) materials. The objective of this research is to examine the seismic performance of RC bridge piers subjected to a Quasi static test (QST), which were preliminary tested under a series of artificial earthquake motions referred to as a Pseudo dynamic test (PDT). The seismic enhancement effect of FRP wrap was also investigated on these RC bridge piers. Six specimens were loaded to induce probable damage by four series of artificial earthquakes, which were developed to be compatible with earthquakes in the Korean peninsula by the Korea Highway Corporation (KHC). Directly after the PDT, six earthquake-experienced columns were subjected to inelastic cyclic loading under a constant axial load of $0.1{f_c}^{\prime}A_g$. Two other reference specimens without the PDT were also subjected to similar quasi-static loads. Test results showed that specimens pre-damaged by moderate artificial earthquakes generally demonstrated good residual seismic performance, which was similar to the corresponding reference specimen. Moreover, RC bridge specimens retrofitted with wrapping fiber composites in the potential plastic hinge region exhibited enhanced flexural ductility.

Experimental study and modelling of CFRP-confined damaged and undamaged square RC columns under cyclic loading

  • Su, Li;Li, Xiaoran;Wang, Yuanfeng
    • Steel and Composite Structures
    • /
    • 제21권2호
    • /
    • pp.411-427
    • /
    • 2016
  • While the cyclic behaviour of fiber-reinforced polymer (FRP)-confined columns is studied rather extensively, the cyclic response especially the energy dissipation of FRP-confined damaged and undamaged square RC columns is not yet fully understood. In this paper, an experimental and numerical investigation was conducted to study the cyclic behavior of two different types of Carbon FRP (CFRP)-confined square RC columns: strengthened and repaired. The main variables investigated are initial damage, confinement of CFRP, longitudinal steel reinforcement ratio. The experimental results show that lower initial damage, added confinement with CFRP and longitudinal reinforcement enhance the ductility, energy dissipation capacity and strength of the columns, decrease the stiffness and strength degradation rates of all CFRP-confined square RC columns. Two hysteretic constitutive models were developed for confined damaged and undamaged concrete and cast into the non-linear beam-column fiber-based models in the software Open System for Earthquake Engineering Simulation (OpenSees) to analyze the cyclic behavior of CFRP-confined damaged and undamaged columns. The results of the numerical models are in good agreement with the experiments.

Experimental behavior of eccentrically loaded RC slender columns strengthened using GFRP wrapping

  • Elwan, S.K.;Omar, M.A.
    • Steel and Composite Structures
    • /
    • 제17권3호
    • /
    • pp.271-285
    • /
    • 2014
  • This paper aims to examine the behavior of slender reinforced concrete columns confined with external glass fiber reinforced polymers (GFRP) sheets under eccentric loads. The experimental work conducted in this paper is an extension to previous work by the author concerning the behavior of eccentrically loaded short columns strengthened with GFRP wrapping. In this study, nine reinforced concrete columns divided into three groups were casted and tested. Three eccentricity ratios corresponding to e/t = 0, 0.10, and 0.50 in one direction of the column were tested in each group. The first group was the control one without confinement with slenderness ratio equal 20. The second group was the same as the first group but fully wrapped with one layer of GFRP laminates. The third group was also fully wrapped with one layer of GFRP laminates but having slenderness ratio equal 15. The experimental results of another two groups from the previous work were used in this study to investigate the difference between short and slender columns. The first was control one with slenderness ratio equal 10 and the second was fully wrapped and having the same slenderness ratio. All specimens were loaded until failure. The ultimate load, axial deformation, strain in steel bars, and failure mechanisms of each specimen were generated and analyzed. The results show that GFRP laminates confining system is less effective with slender columns compared with short one, but this solution is still applied and it can be efficiently utilized especially for slender columns with low eccentric ratio.

Numerical simulation on the cyclic behavior of ultra-high performance concrete filled steel tubular column

  • Heng Cai;Fangqian Deng
    • Structural Engineering and Mechanics
    • /
    • 제85권5호
    • /
    • pp.693-707
    • /
    • 2023
  • In order to deeply reveal the working mechanism of ultra-high performance concrete (UHPC) filled steel tubular columns (UHPCFSTs) under cyclic loading, a three-dimension (3D) macro-mesoscale finite element (FE) model was established considering the randomness of steel fibers and the damage of UHPC. Model correctness and reliability were verified based on the experimental results. Next, the whole failure process of UHPC reinforced with steel fibers, passive confinement effect and internal force distribution laws were comprehensively analyzed and discussed. Finally, a simplified and practical method was proposed for predicting the ultimate bending strengths of UHPCFSTs. It was found that the non-uniform confinement effect of steel tube occurred when the drift ratio exceeded 0.5%, while the confining stress increased then decreased afterwards. There was preferable synergy between the steel tube and UHPC until failure. Compared with experimental results, the ultimate bending strengths of UHPCFSTs were undervalued by the current code provisions such as AISC360-10, EC4 and GB50936 with computed mean values (MVs) of 0.855, 0.880 and 0.836, respectively. The proposed practical method was highly accurate, as evidenced by a mean value of 1.058.

비내진 철근콘크리트 건축물의 FRP 재킷에 대한 내진보강 설계 전략 (Seismic Retrofit Scheme of FRP Column Jacketing System for Non-Seismic RC Building Frame)

  • 황희진;김혜원;오근영;신지욱
    • 한국지진공학회논문집
    • /
    • 제27권6호
    • /
    • pp.293-301
    • /
    • 2023
  • Existing reinforced concrete buildings with seismically deficient details have premature failure under earthquake loads. The fiber-reinforced polymer column jacket enhances the lateral resisting capacities with additional confining pressures. This paper aims to quantify the retrofit effect varying the confinement and stiffness-related parameters under three earthquake scenarios and establish the retrofit strategy. The retrofit effects were estimated by comparing energy demands between non-retrofitted and retrofitted conditions. The retrofit design parameters are determined considering seismic hazard levels to maximize the retrofit effects. The critical parameters of the retrofit system were determined by the confinement-related parameters at moderate and high seismic levels and the stiffness-related parameters at low seismic levels.

Effect of Confined High-Strength Concrete Columns

  • Van, Kyung-Oh;Yun, Hyun-Do;Hwang, Sun-Kyoung
    • 콘크리트학회논문집
    • /
    • 제15권5호
    • /
    • pp.747-758
    • /
    • 2003
  • The moment-curvature envelope describes the changes in the flexural capacity with deformation during a nonlinear analysis. Therefore, the moment-curvature analysis for reinforced concrete columns, indicating the available flexural strength and ductility, can be conducted providing the stress-strain relation for the concrete and steel are known. The moments and curvatures associated with increasing flexural deformations of the column may be computed for various column axial loads by incrementing the curvature and satisfying the requirements of strain compatibility and equilibrium of forces. Clearly it is important to have accurate information concerning the complete stress-strain curve of confined high-strength concrete in order to conduct reliable moment-curvature analysis that assesses the ductility available from high-strength concrete columns. However, it is not easy to explicitly characterize the mechanical behavior of confined high-strength concrete because of various parameter values, such as the confinement type of rectilinear ties, the compressive strength of concrete, the volumetric ratic and strength of rectangular ties. So a stress-strain model is developed which can simulate complete inelastic moment-curvature relations of high-strength concrete columns.

경량콘크리트를 사용한 프리캐스트 바닥판에서 스터드 전단연결재의 거동 (Behavior of Stud Shear Connectors in Precast Deck using Lightweight Concrete)

  • 조선규;이종민;윤석구;최연왕
    • 한국강구조학회 논문집
    • /
    • 제20권2호
    • /
    • pp.227-236
    • /
    • 2008
  • 강합성 교량에서 일반적으로 사용되는 콘크리트는 단위질량이 ${2,300kg/m^{3}}$인 일반콘크리트이다. 그러나 강합성 교량에서 경량콘크리트를 사용한다면 바닥판 자중에 의한 단면력을 감소시킬 수 있어 더욱 경제적인 교량설계가 가능할 것이다. 경량콘크리트를 사용한 강합성 거더 교량에서 적용될 수 있는 바닥판 형식은 크게 현장타설 콘크리트 바닥판과 프리캐스트 바닥판으로 구분할 수 있다. 이 두형식의 바닥판은 시공측면이나 구조적 거동 측면에서 다소 차이가 있어, 바닥판과 강거더를 연결하는 전단연결부도 사용되는 바닥판의 형식에 따라 구조적 거동 특성이 위하여 Push-out 실험을 수행하였다. 또한 베딩층이 있는 프리캐스트 부재에 대해서는 강도감소의 주요한 원인이 되는 베딩층의 균열을 방지하기 위하여 프리캐스트 바닥판과 베딩층 사이에 전단키를 설치하고 베딩층을 횡방향으로 구속시킨 실험체에 대해 실험을 수행하여 그 영향을 평가하였다.

철계 형상기억합금 스트립으로 보강된 콘크리트 기둥의 반복이력거동 평가 (Hysteretic Behavior Evaluation of Reinforced Concrete Columns Retrofitted with Iron-based Shape Memory Alloy Strips)

  • 정새벽;정동혁
    • 한국전산구조공학회논문집
    • /
    • 제35권5호
    • /
    • pp.287-297
    • /
    • 2022
  • 본 논문에서는 철계형상기억합금(Fe SMA) 스트립으로 능동구속된 콘크리트 기둥의 실험적, 해석적 연구결과를 제시한다. Fe SMA과 탄소섬유보강시트(CFRP)로 각각 구속된 콘크리트 공시체의 압축실험을 통해 형상기억합금 기반 능동구속기법의 효과성을 평가하였다. 실험결과, Fe SMA 스트립으로 구속된 콘크리트 공시체가 낮은 구속력에도 불구하고 CFRP 시트로 구속된 공시체에 비해 더 우수한 변형능력을 가지는 것으로 밝혀졌다. 실험을 통해 얻은 구속된 콘크리트의 압축거동 결과를 이용해 소성힌지 영역이 각각 Fe SMA 스트립과 CFRP 시트로 보강된 콘크리트 기둥의 유한요소모델을 구축하였다. 기존 수행된 콘크리트 기둥의 수평반복가력 실험결과를 바탕으로 구축된 기둥 모델을 검증하였고, 각각의 기둥 모델에 대한 수평반복가력 해석을 수행하였다. 해석결과, Fe SMA 스트립으로 보강된 콘크리트 기둥이 CFRP 시트로 보강된 기둥모델에 비해 변형, 에너지 소산능력 향상에 효과적임을 확인하였다.

Experimental behavior of eccentrically loaded R.C. short columns strengthened using GFRP wrapping

  • Elwan, S.K.;Rashed, A.S.
    • Structural Engineering and Mechanics
    • /
    • 제39권2호
    • /
    • pp.207-221
    • /
    • 2011
  • This paper aims to study the behavior of short reinforced concrete columns confined with external glass Fiber Reinforced Polymers (GFRP) sheets under eccentric loads. The experimental part of the study was achieved by testing 9 specimens under eccentric compression. Three eccentricity ratios corresponding to e/t = 0, 0.10, 0.50 in one direction of the column were used. Specimens were divided into three groups. The first group was the control one without confinement. The second group was fully wrapped with GFRP laminates before loading. The third group was wrapped under loading after reaching 75% of failure loads of the control specimens. The third group was investigated in order to represent the practical case of strengthening a loaded column with FRP laminates. All specimens were loaded until failure. The results show that GFRP laminates enhances both failure load and ductility response of eccentrically loaded column. Moreover, the study also illustrates the effect of confinement on the first crack load, lateral deformation, strain in reinforcement and failure pattern. Based on the analysis of the experimental results, a simple model has been proposed to predict the improvement of load carrying capacity under different eccentricity ratios. The predicted equation takes into consideration the eccentricity to cross section depth ratio, the ultimate strength of GFRP, the thickness of wrapping laminate, and the time of wrapping (before loading and under loading). A good correlation was obtained between experimental and analytical results.