• Title/Summary/Keyword: Concrete confinement

Search Result 650, Processing Time 0.021 seconds

Improvement of bond strength and durability of concrete incorporating high volumes of class F fly ash

  • Wu, Chung-Hao;Chen, Chien-Jung;Lin, Yu-Feng;Lin, Shu-Ken
    • Advances in concrete construction
    • /
    • v.12 no.5
    • /
    • pp.367-375
    • /
    • 2021
  • This study experimentally investigated the improvement of bond strength and durability of concrete containing high volume fly ash. Concrete mixtures made with 0%, 25% and 60% replacement of cement with class F fly ash were prepared. Water-binder ratios ranged from 0.28 to 0.72. The compressive, flexural and pullout bond strength, the resistance to chloride-ion penetration, and the water permeability of concrete were measured and presented. Test results indicate that except for the concretes at early ages, the mechanical properties, bond strength, and the durability-related chloride-ion permeability and water permeability of concrete containing high volume (60% cement replacement) fly ash were obviously superior to the concrete without fly ash at later ages of beyond 56 days. The enhanced bond strength for the high volume fly-ash concrete either with or without steel confinement is a significant finding which might be valuable for the structural application.

Improved Transmission of UHSC Column Loads by Puddling of Fiber Reinforced UHSC (강섬유 보강 초고강도 콘크리트의 확대 타설을 통한 기둥 하중 전달 성능 향상)

  • Lee, Joo-Ha;Yang, Jun-Mo;Lee, Seung-Hoon;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.209-216
    • /
    • 2007
  • This study reports on the structural characteristics of slab-column connections using fiber-reinforced ultra-high-strength concrete (UHSC). Compression tests were performed on two slab-column and four isolated column specimens. In the column load tests, slab loads were also applied on the slab-column specimens so that the actual confinement condition at the slab-column joint was considered. The main parameter investigated was the "puddling" of fiber-reinforced UHSC. This paper also investigates the effects of some parameters, such as confinement of slab concrete, steel fibers, and concrete strength of the joint, related to the ability of the slab-column specimens and isolated column specimens without the surrounding slab to transmit axial loads from the UHSC columns through slab-column connections. Furthermore, the ACI Code (2005) and the CSA Standard (2004) are compared to the experimental results. The beneficial effects of the puddling of fiber-reinforced UHSC on the transmission of column loads through slab-column connections are demonstrated.

Confinement models for high strength short square and rectangular concrete-filled steel tubular columns

  • Aslani, Farhad;Uy, Brian;Wang, Ziwen;Patel, Vipul
    • Steel and Composite Structures
    • /
    • v.22 no.5
    • /
    • pp.937-974
    • /
    • 2016
  • While extensive efforts have been made in the past to develop finite element models (FEMs) for concrete-filled steel tubular columns (CFSTCs), these models may not be suitable to be used in some cases, especially in view of the utilisation of high strength steel and high strength concrete. A method is presented herein to predict the complete stress-strain curve of concrete subjected to tri-axial compressive stresses caused by axial load coupled with lateral pressure due to the confinement action in square and rectangular CFSTCs with normal and high strength materials. To evaluate the lateral pressure exerted on the concrete in square and rectangular shaped columns, an accurately developed FEM which incorporates the effects of initial local imperfections and residual stresses using the commercial program ABAQUS is adopted. Subsequently, an extensive parametric study is conducted herein to propose an empirical equation for the maximum average lateral pressure, which depends on the material and geometric properties of the columns. The analysis parameters include the concrete compressive strength ($f^{\prime}_c=20-110N/mm^2$), steel yield strength ($f_y=220-850N/mm^2$), width-to-thickness (B/t) ratios in the range of 15-52, as well as the length-to-width (L/B) ratios in the range of 2-4. The predictions of the behaviour, ultimate axial strengths, and failure modes are compared with the available experimental results to verify the accuracy of the models developed. Furthermore, a design model is proposed for short square and rectangular CFSTCs. Additionally, comparisons with the prediction of axial load capacity by using the proposed design model, Australian Standard and Eurocode 4 code provisions for box composite columns are carried out.

Effects of Bar Deformation on Bond between Reinforcing Steel and Concrete Subjected In Cyclic Loading (반복하중시 철근의 마디형태에 따른 부착특성)

  • 최완철;이재열;이웅세
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.244-250
    • /
    • 2001
  • One of the reasons for brittle failure in reinforced concrete structures subjected to severe earthquake is due to large slip between reinforcing steel and concrete. This study aims to evaluate effects of deformation patterns of ribbed reinforcing bars on bond under cyclic loading. Bond test specimens were constructed with machined bars to test the newly developed reinforcing bars with high relative rib areas. The degree of confinement is also another key parameter in this bond test. From the test results under monotonic and cyclic loading, bond strength and stiffness were evaluated. Bond strength and bond stiffness increase as relative rib areas under cyclic loading for specimens highly confined by transverse reinforcement. The increase rates of the bond performance under cyclic loading are larger than those of specimens under monotonic loading. The developed bars with high relative rib areas will contribute for better bond performance for reinforced concrete structures subjected to severe seismic loadings.

Prediction of ultimate moment anchorage capacity of concrete filled steel box footing

  • Bashir, Muhammad Aun;Furuuchi, Hitoshi;Ueda, Tamon;Bashir, M. Nauman
    • Steel and Composite Structures
    • /
    • v.15 no.6
    • /
    • pp.645-658
    • /
    • 2013
  • The objective of the study is to predict the moment anchorage capacity of the concrete filled steel box (CFSB) as footing by using the 3D finite element program CAMUI developed by authors' laboratory. The steel box is filled with concrete and concrete filled steel tube (CFT) column is inserted in the box. Numerical simulation of the experimental specimens was carried out after introducing the new constitutive model for post peak behavior of concrete in compression under confinement. The experimental program was conducted to verify the reliability of the simulation results by the FE program. The simulated peak loads agree reasonably with the experimental ones and was controlled by concrete crushing near the column. After confirming the reliability of the FEM simulation, effects of different parameters on the moment anchorage capacity of concrete filled steel box footing were clarified by conducting numerically parametric study.

Study on Strengthening Effect and Failure Behavior of CFS Strengthened High Strength RC Columns after Cross -sectional Shape Modification (4각기둥의 단면형상 변형 후 CFS로 보강한 고강도 철근 콘크리트 기둥의 보강효과 및 파괴거동 연구)

  • Jun Kyung-Suk;Kim Jang-Ho;Park Seok-Kyun;Kim Jin-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.259-262
    • /
    • 2005
  • Numerous studies showed that safety and serviceability of many concrete infrastructures and buildings built in 1970's have capacity less than their design capacities and thereby require immediate retrofitting. Currently, these aged concrete structure are being repaired using many repair and strengthening methods developed in the past. Therefore, in this study, a repairing and strengthening method for retrofitting high strength concrete columns that can effectively improve the performance of high strength concrete columns is developed. The square high strength concrete column's cross-sectional shape is modified to octagonal shape by attaching precast members on the surface of the column. Then, the octagonal column surface is wrapped using Carbon Fiber Sheets (CFS). The method allowed the maximum usage of confinement effect of externally wrapped CFS, which resulted in improved strength and ductility of repaired high strength concrete columns.

  • PDF

Size effect in concrete blocks under local pressure

  • Ince, R.;Arici, E.
    • Structural Engineering and Mechanics
    • /
    • v.19 no.5
    • /
    • pp.567-580
    • /
    • 2005
  • Numerous tests on concrete structure members under local pressure demonstrated that the compressive strength of concrete at the loaded surface is increased by the confinement effect provided by the enveloping concrete. Even though most design codes propose specific criteria for preventing bearing failure, they do not take into consideration size effect which is an important phenomenon in the fracture mechanics of concrete/reinforced concrete. In this paper, six series of square prism concrete blocks with three different depths (size range = 1:4) and two different height/depth ratios of 2 and 3 are tested under concentrated load. Ultimate loads obtained from the test results are analysed by means of the modified size effect law (MSEL). Then, a prediction formula, which considers effect of both depth and height on size effect, is proposed. The developed formula is compared with experimental data existing in the literature. It is concluded that the observed size effect is in good agreement with the MSEL.

A Study on Seismic Capacity of Circular Spiral Reinforced Concrete Bridge Piers used in High Strength Concrete (고강도 원형나선철근기둥의 내진성능에 관한 연구)

  • 김광수;김민구;배성용;이재훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.547-552
    • /
    • 2001
  • This research was conducted to investigate the seismic behavior and capacity assessment of circular spiral reinforcement concrete bridge piers used in high strength concrete. The displacement ductility, response modification factor(R), effective stiffness and plastic hinge region etc. was used to assess the seismic behavior and capacity of circular spiral reinforcement concrete bridge piers. The experimental variables of bridge piers test consisted of amount and spacing, different axial load levels. From the quasi-static tests on 9 bridge piers and analysis, it is found that current seismic design code specification of transverse confinement steel requirements and details may be revised.

  • PDF

The Investigation of Blocks on High Strength Concrete (고강도 콘크리트 부재의 응력블록에 관한 검토)

  • 신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.2
    • /
    • pp.93-99
    • /
    • 1990
  • The object of this study was to investigate the flexural stress blocks of High Strength Concrete Members under monotonic loading. Such a stress block should be clearly idealized before High Strength Concrete can be used with confidence in Structural Members. The principal test variables were the Compressive Strength of Concrete, the percentage of longitudinal reinforcement and the spacing of confinement reinforcement. The rectangular stress block of the present ACI Building Code was found to give acceptably conservative flexural strength predictions over the entire range of concrete strength from 280kg/crd (4Ksi)to 1050kg/crd( 15Ksi)

Seismic Performance Assessment of Circular Reinforced Concrete Bridge Piers with Confinement Steel (중실원형 철근콘크리트 교각의 횡방향 철근에 따른 내진성능평가)

  • Kim Tae Hoon;Kang Sang Gyu;Rhee Ji Young;Kim Young Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.85-88
    • /
    • 2005
  • The purpose of this study is to assess the seismic performance of reinforced concrete bridge piers using inelastic finite element analysis. The accuracy and objectivity of the assessment process may be enhanced by the use of sophisticated nonlinear finite element analysis program. A computer program, named RCAHEST(Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures was used. The proposed numerical method for the seismic performance assessment of reinforced concrete bridge piers is verified by comparison with the reliable experimental results.

  • PDF