• Title/Summary/Keyword: Concrete air permeability

Search Result 106, Processing Time 0.025 seconds

The Prediction Model of Carbonation Process by CO2 Diffusion Using the Air Permeability Coefficient for Concrete (콘크리트의 투기계수를 이용한 CO2확산 탄산화진행 예측모델)

  • Kang, Suk-Pyo;Kim, Young-Sun;Song, Ha-Won;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.209-217
    • /
    • 2010
  • Recently, some mathematical models for the prediction on progress of carbonation of concrete were reported. These models take account for $CO_2$ diffusion and chemical reaction between $Ca(OH)_2$ and $CO_2$. Based on the assumption that $CO_2$ diffuses in the carbonation zone and reacts with $Ca(OH)_2$ at the outer face of carbonation zone and non-carbonation zone. In this study, a mathematical model to predict the progress of carbonation of concrete has been established based on the reducing concentration of $Ca(OH)_2$ in the carbonation progress zone, where $Ca(OH)_2$ reacts with $CO_2$ and $Ca(OH)_2$ and $CaCO_3$ coexist. Also, the prediction model of carbonation progress rate of concrete using the air permeability coefficient regarding to $CO_2$ diffusion is developed. As a result of this study, an expression, the model equation is obtained for the prediction of carbonation based on the time and interaction velocity between $CO_2$ and Ca(OH)$_2$ dependent air permeability coefficient. The prediction by the model satisfied the experimental data of the accelerated carbonation for painted concrete. Consequently, the model can predict the rate of carbonation and the potential service life of concrete structure exposed to atmosphere.

Prediction of Long-Term Carbonation Depth by Measurement of the Air Permeability Coefficient of Coating on Concrete (콘크리트에 도포된 도막의 투기계수 측정을 통한 장기 중성화 깊이 예측)

  • Park, Dong-Cheon;Nam, Min-Seok;Kim, Yong-Ro;Ko, Hyo-Jin;Ryu, Dong-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.113-114
    • /
    • 2023
  • This study measured the thickness and speculation coefficient of the coating for existing buildings and calculated the diffusion coefficient of the coating to predict the depth of carbonation through numerical analysis in order to evaluate the impact of the external finish and local environment. As a result, it was possible to predict the short-term and long-term carbonation depth of reinforced concrete buildings coated with coating film with considerable reliability.

  • PDF

The Chloride Diffusion Properties of Concrete with Mineral Admixtures (혼화재를 사용한 콘크리트의 염소이온 확산 특성)

  • Park, Jung-Jun;Koh, Kyoung-Taek;Kim, Do-Gyeum;Kim, Sung-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.239-246
    • /
    • 2004
  • To improve the durability of concrete structure, we usually consider the reduction of water-cement ratio, the increase of concrete cover depth and the use of mineral admixtures. The use of admixtures make concrete more durable and tighten against water in recent papers so it is needed to study more about the relationship between the admixtures and the chloride ion diffusion. Therefore we analyzed the correlation between chloride ion diffusion and physical properties such as compressive strength, void ratio, air permeability of the concrete, and tried to use them as fundamental data for analyzing chloride ion diffusion mechanism of the concrete mixed with mineral admixtures.

Proposal of Plane Spacing Factor for Analyzing Air Void System in Concrete (콘크리트 공극 분석을 위한 평면간격계수의 제안)

  • Jeong, Won-Kyong;Choi, Sung-Yong;Kim, Sung-Hwan;Yun, Kyong-Ku
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.39-47
    • /
    • 2005
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance. Linear traverse method and point count method described at ASTM are the routine analysis of the air void system that have been widely used to estimate the spacing factor in hardened concrete. Recently, many concretes often have a spacing factor higher than the generally accepted $200-250{\mu}m$ limit for the usual range of air contents. This study is proposed to estimate the plane spacing factor by calculation of simplicity. The plane spacing factor need two parameters that are air content and numbers of air voids in the hardened concrete. Those obtained from the standard air-void system analysis of the ASTM C 457. The equation is valid for all values of paste-to-air ratio because the estimation of paste content is unnecessary at the using ASTM C 457. The plane spacing factor yields a similar estimate of the standard spacing factor.

  • PDF

Air-tightness Evaluation of Tube Structures for Super-speed Tube Railway Systems: II. System Test and Parametric Analysis (초고속 열차 시스템을 위한 튜브 구조물의 기밀성 평가 : II. 시스템 실험 및 파라메터 해석)

  • Park, Joo-Nam;Kim, Lee-Hyeon;Nam, Seong-Won
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.2
    • /
    • pp.151-159
    • /
    • 2011
  • This study performed an experimental study for air-tightness performance evaluation of concrete tube structures with joints. The test specimens consist of a continuous concrete tube, a concrete tube with a joint in the middle, and a segmented concrete tube. The test is performed in such a way that the inner pressure of the tube is dropped down to 0.1atm and the increase of the pressure is monitored with time. An equivalent air permeability is then calculated based on the test results. The results show that, as expected, a structure with more joints or bonds tends to be less air-tight. A sensitivity study shows that the system air-tightness performance level becomes higher as either the diameter or the thickness of the tube increases. Moreover, the increase in the diameter or the thickness of the tube makes an effort to enhance the air-tightness more effective.

Basic Properties of Latex-Modified Concrete Using Fly-ash (플라이애쉬를 이용한 라텍스개질 콘크리즈의 기초물성 연구)

  • Hong, Chang-Woo;Jeong, won-Kyong;Kim, Kyong-jin;Yun, Kyong-ku
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.205-211
    • /
    • 2006
  • The purpose of this study was to evaluate the effects of fly-ash on strength development and durability of latex-modified concrete (LMC) and ordinary portland cement concrete (OPC). Main experimental variables were latex contents (0%, 10%, 15%) and fly-ash content (0, 10%, 20%, 30%). Air content and slump tests were performed to check the basic properties of fresh concretes, and compressive strength, flexural strength, rapid chloride ion permeability and chemical resistance were measured to analyze the basic properties of hardened concretes. The test results showed that air contents of LMC with fly ash decreased as fly-ash contents increased from 0% to 30%. Compressive and flexural strength developments of LMC with fly ash were quite similar to those of LMC without fly ash. However, the long-term flexural strength development of LMC with fly ash after 90 days were bigger than that of LMC without fly ash. Chloride ion permeability and chemical resistance decreased rapidly as the content of fly ash increased. Thus, fly ash could be used at LMC in order to reduce water permeability.

An Experimental study on the Fundamental Properties of Restorative Mortar Spread with Liquefied Antibiotics for Repair of Sewer Concrete (액상 항균제를 도포한 단면복구용 모르타르의 기초물성에 관한 실험적 연구)

  • Lee Dong-Heck;Jang Jae Bong;Cho Bong-Suk;Kim Jae-Hwan;Lee Byoung-Ky;Kim Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.305-308
    • /
    • 2005
  • The sulfuric acid may react with the hardened cement paste and originate expansive products which can induce swelling and disaggregation of concrete. The purpose of this study is to estimate the antibacterial performance of antibiotics and the effect of absorbed condition of restorative mortar, the number of coating times and coating contents with antibiotic on the fundamental properties of restorative mortar spead with antibiotics. Also, testing items such as bonding strength, abrasion contents, contents of water absorption, contents of air permeability was tested to estimate the fundamental properties in this study. In results, the novellus bacillus inhabiting in sewer concrete structures was restrained by antibiotics developed in this study. And bonding strength of restorative mortar spread with antibiotics was similla to that of plain mortar. But, resistance to abrasion, water absorption and air permeability of restorative mortar spread with antibiotics was superior to that of plain mortar.

  • PDF

A Study on improving Effect of Durability Performance Using Penetration waterproofing Agent of Ceramic nano materials (세라믹계 나노물질을 이용한 침투성 방수제의 내구성능 개선효과 연구)

  • Ryu Gum-Sung;Park Jung-Jun;Koh Kyoung-Taek;Kim Do-Gyeum;Lee Jang-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.176-179
    • /
    • 2004
  • The latest concrete structure has showed that the deterioration of durability has been increased by the damage from salt, carbonization, freezing & thawing and the others. Therefore, the measures for the concrete which has deteriorated durability have been taken. Among them, it has been often used that surface treatment which cuts off the deterioration factors of durability by protecting the surface of concrete. This study was evaluated the surface improving agent for permeability, watertightness, air-permeability, chemical resistance and elution resistance.

  • PDF

Development of Mixing Model for High Durability Creek Concrete Having 300kgf/$\textrm{cm}^2$ Compressive Strength (압축강도 300kgf/$\textrm{cm}^2$ 내외의 하수암거용 고내구성 콘크리트 배합모텔 개발)

  • 이창수;윤인석;이규동;고석봉
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.271-274
    • /
    • 2001
  • Recently, we are facing with the trend of demanding high durability concrete for creek structures. When creek structures are deteriorated, it is very difficult to repair them. The objective of this paper is to develop a mixing model for high durability creek concrete having 300kg/$\textrm{cm}^2$ compressive strength. According to the result of durability experiment, high durability concrete for creek structures has high resistance of air permeability, absorption, chloride diffusion, and chemical attack.

  • PDF

An Experimental Study on Manufacturing Permeable Concrete Blocks from Recycled Industrial By-Products of Oyster Shell and Blast Furnace Slag (굴패각 및 고로슬래그 산업부산물을 재활용한 콘크리트 투수블록의 제조에 대한 실험적 연구)

  • Seok-Hong Eo;Won-Seok Huh;Sang-Hoon Ha;Chang-Ryeol Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1135-1144
    • /
    • 2023
  • In this paper, bending strength and permeability tests were conducted on concrete permeable blocks manufactured by recycling industrial by-products of oyster shell and blast furnace slag to measure and compare bending strength and permeability coefficient, and present experimental research results. To this end, a total of 54 specimens with a size of 200x200x60mm for surface layer and base layer were manufactured, and bending strength and permeability test were carried ourt accoridng to KS F 4419. Eighteen types of mixing designs were implemented by varying the mixing and replacement rates of oyster shells and blast furnace slag. As a result of the experiment, the higher the mixing ratio of oyster shell, the lower the bending strength and the permeability coefficient. Thereafter, a total of three permeable blocks with dimensions of 200x200x60mm were manufactured and subjected to bending strength and permeability tests according to KS F 4419. As a result of the test, the bending strength satisfies the standard of KS F 4419, and the permeability coefficient is 12 times higher than the standard of KS F 4419. It seems that the proper mixing of oyster shells and blast furnace slag increases the amount of air, and further research on durability and economic feasibility of materials used to manufacture permeable blocks is required.