• 제목/요약/키워드: Concrete Maturity

검색결과 149건 처리시간 0.025초

열량계와 겉보기 활성화 에너지를 이용한 콘크리트의 압축강도 예측에 관한 실험적 연구 (A Experimental Study on Prediction of Compressive Strength of Concrete Based on Maturity Using Apparent Activation Energy)

  • 김한솔;장종민;김영관;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.73-74
    • /
    • 2020
  • Predicting the compressive strength of concrete is important for shortening construction time and reducing construction costs. In this study, the coefficients required for maturity method and compressive strength prediction equation were calculated by measuring the cement hydration reaction rate, concrete setting time and ultimate strength. The experiment was conducted in an isothermal environment of 10℃, 20℃ and 30℃ using a normal Portland cement, and the experiment was conducted with a total of 9 levels of W/C (40%, 50%, 60%) of 3 levels for each temperature. As a result of comparing the predicted strength and the measured strength for each blend, only an error of less than 5% was found for all blending and curing periods.

  • PDF

적산온도 방식을 이용한 고강도 콘크리트의 강도 예측 (Prediction of Strength of High-Strength Concrete by the Maturity Method)

  • 길배수;김태근;한장현;권영진;남재현;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.259-264
    • /
    • 1999
  • The aim of this study of to compare the development of compressive strength of high-strength concrete with maturity and investigate the applicability the strength prediction models. An experiment was attempted on the high-strength concrete mixes using portland cement replaced by silica fume of 10% by weight of cement, the water-binder ratios of mixes being 0.30 and 0.35, the curing temperatures being 30, 20, 10, 5$^{\circ}C$. Test results of mixes are statistically analyzed to infer the correlation coefficient between the maturity and the compressive strength of high-strength concrete. The constant of strength prediction equation were determined from test results, and the equation was adopted to predict the strength of slab(W80$\times$D100$\times$H20cm). The slab was cast in the laboratory from the same batch water-binder ratio of 0.30, and cores were cut from slab in order to estimate the actual strength. These values are used to compare with predicted value. The present study allows more realistic determination of early age compressive strength of high-strength concrete and can be efficiently used to control the quality in actual construction.

  • PDF

양생온도 이력이 콘크리트 강도발현에 미치는 영향 (The Effect of Curing Temperature History on Concrete Strength Development)

  • 고훈범;양은익;음성우
    • 콘크리트학회지
    • /
    • 제10권5호
    • /
    • pp.89-100
    • /
    • 1998
  • 본 연구는 양생온도이력이 콘크리트 강도에미치는 영향을 평가하기 위한 것으로 물 시멘트비가 60%, 45%, 26%인 3종류의 콘크리트에대하여 5$^{\circ}C$부터 5$0^{\circ}C$까지의 항온양생과 초기재령에 고온도이력을 변수로 한 변동온도양생을 실시한 공시체의 압축강도를 측정하였다. 또한 그 실험결과에 강도평가 방법의 하나인 Maturity 개념을 도입하여 강도평가에 미치는 재령, w/c, 온도이력 등에 대한 영향을 평가하였다. 항온양생 실험결과에 따르면 물시멘트비가 낮을수록 초기재령에서의 강도발현은 높게 나타나며 양생온도 5$0^{\circ}C$인 경우를 제외하고 재령7일까지의 강도발현은 양생온도가 높을수록 크게 나타나고 있다. 한편, 변동온도양생실험결과에 의하면 초기재령에서 고온양생한 콘크리트의 강도발현은 물시멘트비의 영향을 크게 받으며, 1주 이후의 양생온도가 강도발현에 미치는 영향은 1주까지의 고온도이력에 대한 영향에 비교해 2차적이다. 기존의 Maturity개념인 Saul-Bergstrom의 함수와 Ooi의 함수를 가지고 항온 및 변동온도 양생실험결과를 분석한 결과, 전체적으로 Saul-Bergstrom식에 의한 경우가 실험값과의 차이가 작게 나타났으나 두 식 모두 Maturity 가 큰 경우에는 계산에 의한 값이 실험에 의한 값보다 크게 나타나고 있어 장기 재령시 강도평가는 한계강도 개념을 고려한 새로운 Matruity함수를 제안할 필요가 있다.

2성분계 콘크리트의 구조체 보정강도(mSn) 산정을 위한 적산온도 기반 콘크리트의 압축강도 예측 연구 (A Study on the Prediction of Concrete Strength Based on Maturity Method for Calculating the Concrete Strength Correction Value (mSn) of Two-Component Concrete)

  • 김한솔;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.129-130
    • /
    • 2023
  • The compressive strength of concrete is greatly affected by the temperature inside the concrete at the initial age immediately after pouring. In the KCI Concrete Standard Specification, only the temperature correction strength (Tn) according to the curing temperature is applied in the mixing strength calculation formula, and mSn is not considered. The formula based on the Chrino model of the blast furnace slag concrete was calculated, and the strength of the structural concrete and the strength of the water cured specimen in the same mixture were compared with the predicted strength. As a result, the error between the predicted strength and the measured strength was greater in the structural concrete than in the concrete specimen.

  • PDF

양생온도변화에 따른 고로슬래그 시멘트를 사용한 콘크리트의 강도증진 성상 (Strength Development of Concrete Using Blast-Furnace Slag Cement under Various Curing Temperatures)

  • 윤기원;유호범;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.163-166
    • /
    • 1999
  • In this paper, strength development of concrete using blast-furnace slag cement(BSC) and ordinary portland cement(OPC) are discussed under varius W/C and curing temperatures. According to the experimental results, strength development of BSC concrete is lower than that of OPC concrete in low temperature at early age and maturity. In high curing temperature, BSC concrete has higher strength development than that of low temperature regardless of the elapse of age and maturity. BSC has much effect on the strength development of concrete at the condition of mass concrete, hot weather concreting and the concrete products with the steam curing, which is influenced by high temperature.

  • PDF

플라이애쉬를 혼입한 현장타설 매스콘크리트의 압축강도 추정에 관한 실험적 연구 (An Experimental Study on Prediction of Compressive Strength of the In situ Mass Concrete with Fly-ash)

  • 길배수;채영석;남재현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권1호
    • /
    • pp.163-169
    • /
    • 1999
  • The object of this study is to compare properties of massive fly-ash concrete with plain concrete. Two concrete mixtures comprising two batch each $1.0m^3$ in volume, were made from ready mixed concrete batch plant. The water-to-cementitious materials ratio was kept constant at 51.4%. Therefore, massive concrete specimen($W800{\times}D800{\times}H800mm$) was cast from ready mixed concrete to analyze history of temperature and core strength properties. Bleeding, time of slump loss and time of setting of the fresh concrete were measured. In order to estimate the properties of massive fly-ash concrete in hardened concrete, non-destructive tests such as rebound hardness, ultrasonic pulse velocity and maturity were performed and analyzed.

  • PDF

양생온도에 따른 콘크리트의 역학적 특성에 관한 연구 (The Effect of Curing Temperature on the Mechanical Property of Concrete)

  • 김진근;김훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.93-98
    • /
    • 1994
  • The property of concrete at different places in mass concrete is affected by the age under the same curing temperature. For more accurate analysis of thermal stress in mass cocnrete, it is necessary to obtain the property of concrete with age and curing temperature. In this study, the effects of curing temperature and age (Maturity) on the development of the property of concrete were investigated by using concrete specimens made with type I cement. The curing temperatures are 23$^{\circ}C$, 5$0^{\circ}C$, and 8$0^{\circ}C$, respectively. As the maturity increases, the strength of concrete was increased. The results obtained experimentlly was compapred with the previous models, and good agreements was obtained.

  • PDF

한중콘크리트의 부재 단면별 온도범위와 강도변화특성에 관한 실험적 연구 (An experimental study on the difference of temperature and strength according to member size for cold weather concrete)

  • 김명원;박광수;조영권;이준구;김관호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.421-424
    • /
    • 2005
  • Discusses the results of an investigation of the relationship between maturity in field-cured specimens and that from the thinner dimension structure to thick, particularly at cold weather concrete. Tests were carried out on two different concrete mixes with 28 day compressive strengths ranging approximately 30MPa. Ready-mixed concrete was used, and test specimens were the conventional field-cured 10$\times$20cm concrete cylinder with insulating materials and without them, and test structures were the thinner(width 20cm), the general(width 40cm), the thick dimension(width 60cm), respectively. Tests were performed at age of 3, 7, 14, 28 day. Analyses of test results show that the maturity of concrete for require compressive strength was suggested to be keep higher than $164D^{circ}D$ until at least from 8day to 10day

  • PDF