• Title/Summary/Keyword: Concrete Bricks

Search Result 60, Processing Time 0.027 seconds

Properties of Mortar with Polysilicon Sludge Based Active Loess Cement (활성황토 시멘트 기반 폴리실리콘 슬러지를 사용한 모르타르의 특성)

  • Kang, Jeon-Uk;Kim, Dae-Yeon;Shin, Jin-Hyeon;Lee, Sang-Soo;Song, Ha-Young
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.275-282
    • /
    • 2018
  • This study examines the ways to address environmental issues by utilizing activated loess to reduce the amount of cements that emit a large amount of carbon dioxide during the process of manufacturing, and by reusing the polysilicon sludge produced as a result of manufacturing polysilicon, one of the components for solar power generation panels. The findings of the experiment showed that the optimal replacement ratio of the polysilicon sludge is 20%, 35% for W/B, and 20% for the ratio of the fine aggregate addition. As it is deemed that utilizing the polysilicon sludge for reinforced concrete may lead to rebar corrosion due to the $CI^-$ contained in the sludge, it can be considered to use for unreinforced concrete or bricks.

A Study on Estimating Recycling Potential of Demolition Waste Generated in End-of-Life of Buildings by Structural Type Considering Economic Efficiency (경제적 효율성 측면에서 건축물 구조를 고려한 해체폐기물의 재활용가능성에 관한 연구)

  • Cha, Gi-Wook;Kim, Jin Ho;Moon, Hyeun Jun;Kim, Young-Chan;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.4
    • /
    • pp.153-161
    • /
    • 2020
  • This study investigates the recycling potential of demolition waste (DW) according to building structure, while considering economic aspects. For that, this study surveyed 1,034 residential buildings to collect reliable information on demolition waste generation rates (DWGRs). This study suggested a method for operational cost calculation for each stage and carried out an inventory analysis. The economic value of recycled DW materials was also calculated. And then, the recycling potential(RP) was calculated by building structures and waste types. RP by building structure was low (27-40%), and RP was found in the order of masonry-block, wooden, RC and concrete-brick. By type of DWs, the RP of aggregates was considerably lower than 7%, and DWs such as wood, plastics, and metals showed more than 100% RP. Considering the results of this study, In order to improve the RP of buildings and DWs, the diversification of products that recycled waste like aggregates (i.e., mortar, concrete, bricks, blocks, tiles) and the development of high value-added products are considered to be the most urgent problems. Based on the above RP results, this study proposed a more advanced method for life cycle assessment of buildings and demolition waste.

A Study on the Structure Behavior of Dry-assembled Wall with Concrete Blocks subjected to Cyclic Lateral Load (콘크리트블록으로 건식조립된 벽체의 수평반복하중에 대한 구조거동 연구)

  • Lee, Joong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.440-447
    • /
    • 2020
  • Masonry structures are used as bearing walls in small buildings, but they are generally considered non-bearing walls. They are used as partition walls that divide the interior spaces of the frame structures of buildings. In addition, wetting techniques that use mortar as an adhesive between blocks or bricks in construction are vulnerable to climatic conditions, especially cracks in mortar, which can cause conduction collapse of the walls in seismic loading. The purpose of this research was to propose a dry concrete block construction method that complements the weak axial shear stiffness and improves the weakness of the wet construction method as well as to investigate its structural behavior. In this study, the material properties of concrete blocks were examined, and the seismic performance of the proposed dry assembly structure was verified by structural behavior tests on horizontal cyclic loads. First, in these study results, concrete blocks can be applied to the dry block construction method instead of wet construction methods because they secure more than C-type blocks in KS regulations. Second, the structural performance of the wall against a horizontal cyclic load indicates that the resisting force of the assembly block wall is increased by increasing the horizontal length of the wall, forming several diagonal cracks. Finally, the proposed dry block wall structure requires a seismic performance assessment considering that the ratio of the shape of the wall by height and length is considered a major influence variable on the structural behavior under a horizontal load.

A Study on the Materials and Techniques of Outdoor Biotop for Environment-friendly Community (친환경 주거단지 외부공간의 비오톱 조성을 위한 재료 및 기법 연구)

  • Cho, Dong-Gil;Cho, Tong-Buhm
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.1
    • /
    • pp.72-81
    • /
    • 2007
  • This study mainly aims at suggesting plans applicable to the outdoor of environment-friendly communities in Korea by leveraging more natural conditions and materials when creating an outdoor biotop for an environment-friendly community and generating material types and development techniques enabling a natural circulation system. To this end, materials used in the outdoor of environment-friendly communities and traditional residential areas in Korea and biotop materials found in natural areas were examined. First, when the case examples of environment-friendly communities were reviewed, biotop spaces and materials that may function as habitats were hardly found. Materials used in biotop were mainly man-made structures made of artificial or processed materials, such as concrete, stones, bricks, woods and steels. Meanwhile, the outdoor space of traditional Korean villages had stone walls, soil walls, rock piles and composite piles, which composed of natural materials such as rocks, soil and plants, that naturally formed porous spaces along with the introduction of plants and provided habitats for a variety of insects. In natural areas, naturally created biotop spaces, such as rock piles, log piles, old tree deployment, branch piles, hay stacks and defoliated leaves, were found. Meanwhile, when spaces and materials available for biotop creation were reviewed to create an environment-friendly residential complex, they were divided into fences and hedges, green spaces between parks and residential buildings, ponds and waterscape spaces, zones separating pedestrian walks and roadways, breast walls and slope boundary, plant box and pergola. For each space, materials used for creating biotops and that were found in traditional Korean residential areas and natural areas were applied and suggested.

Introduction of sand marble wastes in the composition of mortar

  • Hebhoub, H.;Belachia, M.;Djebien, R.
    • Structural Engineering and Mechanics
    • /
    • v.49 no.4
    • /
    • pp.491-498
    • /
    • 2014
  • During the past years, the protection of the environment has become a major concern out passing the state frontiers to reach a planetary dimension. Depository waste sites have become a serious problem in terms of their locations and costs. On the other hand, the construction industry has a leading place in terms of quantities of waste produced from the start to the end of each construction site, by the large amounts of raw materials used and their respective consequences on the environment. The recycling of quarry wastes products, of demolished concrete, bricks and large quantities of waste resulting from the transformation of marble blocks can provide ideal solutions and advantages for the preservation of the environment, to become a supplementary source of aggregates. The main purpose of this study is to show technically the possibility of recuperating the aggregates of marble wastes as a partial substitute or total in the mortars. The aggregates used in this study is a sand of marble wastes (excess loads of sand exposed to bad weather conditions) of the quarry derived from Fil-fila marble (Skikda, east of Algeria). To achieve this work, we have studied the effect of sand substitution of marble wastes in the mortar with rates of (25, 50, 75, 100%); comparing the results obtained with reference samples (0%), the properties when the samples are fresh, and the mechanical performances of mortars at solid state (loss and gain of weight, dimensional variations). The introduction of recycled sand in the mortars gives good results and can be used as granulates.

The Effect of Urban Shade Trees on the WBGT(Wet Bulb Globe Thermometer Index) (도심 녹음수의 체감온도지수(WBGT) 조절효과)

  • 주민진;이춘석;류남형
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.51-59
    • /
    • 2004
  • Focusing on WBGT(Wet Bulb Globe Thermometer Index) according to the LAI(Leaf Area Index) variation of trees, this study verifies the effects of urban shade trees on the outdoor thermal environment. As for methodology, air$.$globe temperature, air humidity and WBGT were measured under three shade trees whose LAIs were 2.1, 4.0 and 8.2 respectively at midday(12:00-13:00) of 14 sunny days from the 4th through the 29th day of September 2003. Those factors were also measured at the unshaded areas and compared with the values of shaded areas. The measured site was paved with interlocking concrete bricks. The measurements were analyzed through the ANCOV A(Analysis of Covariance) and the regression routines of SPSS11 for windows (SPSS Inc., 2001). The major findings were as follows. 1. The direct correlation between WBGT and LAI was very low. On the contrary, the WBGT showed close correlation with air$.$globe temperature and air humidity, and the LAI also showed very close correlation with globe temperature. These results tell that dominant shading effect by the tree is on the screening of direct solar radiation which lower the globe temperature and WBGT consequently. 2. While the average globe temperatures and WBGT at unshadowed area were 40.4$^{\circ}C$ and 26.2$^{\circ}C$ respectively, the former under the shade tree with LAI 2.1, 4.0 and 8.2 were 34.5$^{\circ}C$, 32.6$^{\circ}C$ and 30.2$^{\circ}C$, and the latter were 24.6$^{\circ}C$, 24$^{\circ}C$ and 23.4$^{\circ}C$ respectively. 3. The relationship between LAI(x) and WBGT(y) can be presented with the following equation: y = 24.23+1.53 $e^{-x}$+0.36x $e^{-x}$+0.46 $x^2$ $e^{-x}$ ($R^2$ =.98) =.98)

Strength, Absorption and Interfacial Properties of Mortar Using Waste Shells as Fine Aggregates (잔골재를 패각으로 치환한 모르터의 강도, 흡수율 및 계면 결합형태)

  • Moon, Hoon;Kim, Ji-Hyun;Lee, Jae-Yong;Chung, Chul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.523-529
    • /
    • 2014
  • Large amounts of waste shells have been produced each year from shellfish raising industries located in Korean costal areas. Due to the limited space for the waste shell disposal, the related environmental problem has been a serious issue. It is believed that using the waste shells as a source of aggregate for mortar, concrete or bricks can be a good solution. In this research, possibility of utilizing waste shells as an aggregate of mortar is investigated. Waste shells of manila clam, cockle, clam, sea mussel, and oyster were properly crushed, sieved, and sorted to meet the requirements of the grading of standard fine aggregate. After that, the waste shells were used as partial and total replacement of the fine aggregate, and their absorption and 28-day compressive strengths of mortar were measured. In general, replacement of waste shells increased the absorption and decreased the strength. However, one specimen with cockle increased compressive strength as replacement ratio increased. Mortar with cockle of 50% and 100% replacement showed higher compressive strength than that of control mortar. This increase of compressive strength was found to be affected by the strong interfacial bonding properties of the cockle and a cement matrix.

Shake-table study of plaster effects on the behavior of masonry-infilled steel frames

  • Baloevic, Goran;Radnic, Jure;Grgic, Nikola;Matesan, Domagoj
    • Steel and Composite Structures
    • /
    • v.23 no.2
    • /
    • pp.195-204
    • /
    • 2017
  • The effects of plaster on the behavior of single-story single-bay masonry-infilled steel frames under in-plane base accelerations have been experimentally investigated by a shake-table. Tested structures were made in a 1/3 scale, with realistic material properties and construction methods. Steel frames with high and low flexural rigidity of beams and columns were considered. Each type of frame was tested with three variants of masonry: (i) non-plastered masonry; (ii) masonry infill with conventional plaster on both sides; and (iii) masonry infill with a polyvinyl chloride (PVC) net reinforced plaster on both sides. Masonry bricks were made of lightweight cellular concrete. Each frame was firstly successively exposed to horizontal base accelerations of an artificial accelerogram, and afterwards, to horizontal base accelerations of a real earthquake. Characteristic displacements, strains and cracks in the masonry were established for each applied excitation. It has been concluded that plaster strengthens the infill and prevents damages in it, which results in more favorable behavior and increased bearing capacity of plastered masonry-infilled frames compared to non-plastered masonry-infilled frames. The load-bearing contribution of the adopted PVC net in the plaster was not noticeable for the tested specimens, probably due to relative small cross section area of fibers in the net. Behavior of masonry-infilled steel frames significantly depends on frame stiffness. Strong frames have smaller displacements than weak frames, which reduces deformations and damages of an infill.

Investigation of Seismic Performance of RC Wall-Slab Frames with Masonry Infill (조적채움벽을 갖는 RC 벽-슬래브 골조의 내진성능 연구)

  • Kim, Chan Ho;Lee, Seung Jae;Heo, Seok Jae;Eom, Tae Sung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.137-147
    • /
    • 2022
  • This study investigated the seismic performance of reinforced concrete (RC) wall-slab frames with masonry infills. Four RC wall-slab frames with or without masonry infill were tested under cyclic loading. The RC frames were composed of in-plane and out-of-plane walls and top and bottom slabs. For masonry infill walls, cement bricks were stacked applying mortar paste only at the bed joints, and, at the top, a gap of 50 mm was intentionally left between the masonry wall and top RC slab. Both sides of the masonry walls were finished by applying ordinary or fiber-reinforced mortars. The tests showed that despite the gap on top of the masonry walls, the strength and stiffness of the infilled frames were significantly increased and were different depending on the direction of loading and the finishing mortars. During repeated loading, the masonry walls underwent horizontal and diagonal cracking and corner crushing/spalling, showing a rocking mode inside the RC wall-slab frame. Interestingly, this rocking mode delayed loss of strength, and as a result, the ductility of the infilled frames increased to the same level as the bare frame. The interaction of masonry infill and adjacent RC walls, depending on the direction of loading, was further investigated based on test observations.

A Study on the Structural Characteristics and Estimation of Refrigerating. Load for the Fruit Storage (청과물저장고의 구조특성 및 냉각부하량 산정에 관한 연구)

  • 이석건;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.1
    • /
    • pp.4038-4051
    • /
    • 1976
  • This study was intended to provide the basic design creteria for the refrigerated storage, and to estimate the required optimum capacity of refrigerator for the different sizes and kinds of the existing fruit storage. The structural characteristics of the existing fruit storages in Pyungtaek-khun of Kyungki-do were surveyed. The average out-door air temperature during the expected storage life after harvesting, was obtained by analyzing the weather information. The heat transfer rates through the different models of storage walls were estimated. The refrigerating load required for different models of fruit storage was analyzed in the basis of out-door air temperature. The results obtained in this study are summarized as follows: 1. The fruit storages surveyed were constructed on-ground, under-ground and sub-ground type buildings. The majority of them being the on-ground buildings are mostly made of earth bricks with double walls. Rice hull was mostly used as the insulating materials for their walls and ceilings. About 42% of the buildings were with the horizontal ceiling, 22% with sloped ceiling, and about 36% without ceiling. About 60% of the storage buildings had floor without using insulated material. They were made of compacted earth. 2. There is no difference in heat transfer among six different types of double walls. The double wall, however, gives much less heat transfer than the single wall. Therefore, the double wall is recommended as the walls of the fruit storage on the point of heat transfer. Especially, in case of the single wall using concrete, the heat transfer is about five time of the double walls. It is evident that concrete is not proper wall material for the fruit storage without using special insulating material. 3. The heat transfer through the storage walls is in inverse proportion to the thickness of rice hull which is mostly used as the insulating material in the surveyed area. It is recommended that the thickness of rice hull used as the insulating material far storage wall is about 20cm in consideration of the decreasing rate of heat transfer and the available storage area. 4. The design refrigerating load for the on-ground storages having 20 pyung area is estimated in 4.07 to 4.16 ton refrigeration for double walls, and 5.23 to 6.97 ton refrigeration for single walls. During the long storage life, however, the average daily refrigerating load is ranged from 0.93 to 0.95 ton refrigeration for double walls, and from 1.15 to 1.47 ton refrigeration for single walls, respectively. 5. In case of single walls, 50.8 to 61.4 percent to total refrigerating load during the long storage life is caused by the heat transferred into the room space through walls, ceiling and floor. On the other hand, 39.1 to 40.7 percent is for the double walls. 6. The design and average daily refrigerating load increases in linear proportion to the size of storage area. As the size increases, the increasing rate of the refrigerating load is raised in proportion to the heat transfer rate of the wall. 7. The refrigerating load during the long storage life has close relationship to the out-door air temperature. The maximum refrigeration load is shown in later May, which is amounted to about 50 percent to the design refrigerating load. 8. It is noted that when the wall material having high heat transfer rate, such as the single wall made of concrete, is used, heating facilities are required for the period of later December to early February.

  • PDF