• Title/Summary/Keyword: Concrete Ablation

Search Result 10, Processing Time 0.024 seconds

Analysis for the Coolability of the Reactor Cavity in a Korean 1000 MWe PWR Using MELCOR 1.8.3 Computer Code

  • Lee, Byung-Chul;Kim, Ju-Yeul;Chung, Chang-Hyun;Park, Soo-Yong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.669-674
    • /
    • 1996
  • The analysis for the coolability of the reactor cavity in typical Korean 1000 MWe Nuclear Unit under severe accidents is performed using MELCOR 1.8.3 code. The key parameters molten core-concrete interaction(MCCI) such as melt temperature, concrete ablation history and gas generation are investigated. Total twenty cases are selected according to ejected debris fraction and coolant mass, The ablation rate of concrete decreases as mass of the melt decreases and coolant mass increases. Heat loss from molten pool to coolant is comparable to total decay heat, so concrete ablation is delayed until water is absent and crust begins to remove. Also, overpressurization due to non-condensible gases generated during corium and concrete interacts can cause to additional risk of containment failure. It is concluded that flooded reactor cavity condition is very important to minimize the cavity ablation and pressure load by non-condensible gases on containment.

  • PDF

A Study on the Applicability of MELCOR to Molten Core-Concrete Interaction Under Severe Accidents

  • Kim, Ju-Youl;Chung, Chang-Hyun;Lee, Byung-Chul
    • Nuclear Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.425-432
    • /
    • 2000
  • It has been an essential part for the safety assessment of nuclear power plants to understand various phenomena associated with the molten core-concrete interaction(MCCI) under severe accidents. In this study, the severe accident analysis code MELCOR was used to simulate the MCCI experiments such as SWISS and SURC test series which had been performed in Sandia National Laboratories(SNL). The calculation results were compared with corresponding experimental data such as melt temperature, concrete ablation distance, gas generation rate, and aerosol release rate. Good agreements were observed between MELCOR calculation and experimental data. The melt pool was sustained within the range of high temperature and the concrete ablation occurred continuously. The gas generation and aerosol release were under the influence of melt temperature and overlying water pool, respectively.

  • PDF

CONTRIBUTIONS OF THE VULCANO EXPERIMENTAL PROGRAMME TO THE UNDERSTANDING OF MCCI PHENOMENA

  • Christophe, Journeau;Piluso, Pascal;Correggio, Patricia;Ferry, Lionel;Fritz, Gerald;Haquet, Jean Francois;Monerris, Jose;Ruggieri, Jean-Michel;Sanchez-Brusset, Mathieu;Parga, Clemente
    • Nuclear Engineering and Technology
    • /
    • v.44 no.3
    • /
    • pp.261-272
    • /
    • 2012
  • Molten Core Concrete Interaction (MCCI) is a complex process characterized by concrete ablation and volatile generation; Thermal and solutal convection in a bubble-agitated melt; Physico-chemical evolution of the corium pool with a wide solidification range (of the order of 1000 K). Twelve experiments have been carried out in the VULCANO facility with prototypic corium and sustained heating. The dry oxidic corium tests have contributed to show that silica-rich concrete experience an anisotropic ablation. This unexpected ablation pattern is quite reproducible and can be recalculated, provided an empirical anisotropy factor is assumed. Dry tests with oxide and metal liquid phases have also yielded unexpected results: a larger than expected steel oxidation and unexpected topology of the metallic phase (at the bottom of the cavity and also on the vertical concrete walls). Finally, VULCANO has proved its interest for the study of mitigation solutions such as the COMET bottom flooding core catcher.

Efficacy of ablation and sclerotherapy for the management of ovarian endometrioma: A narrative review

  • Jee, Byung Chul
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.2
    • /
    • pp.76-86
    • /
    • 2022
  • Ovarian cystectomy is the preferred technique for the surgical management of ovarian endometrioma. However, other techniques such as ablation or sclerotherapy are also commonly used. The aim of this review is to summarize information regarding the efficacy of ablation and sclerotherapy compared to cystectomy in terms of ovarian reserve, the recurrence rate, and the pregnancy rate. Several studies comparing ablation versus cystectomy or sclerotherapy versus cystectomy in terms of the serum anti-Müllerian hormone (AMH) decrement, endometrioma recurrence, or the pregnancy rate were identified and summarized. Both ablation and cystectomy have a negative impact on ovarian reserve, but ablation results in a smaller serum AMH decrement than cystectomy. Nonetheless, the recurrence rate is higher after ablation than after cystectomy. More studies are needed to demonstrate whether the pregnancy rate is different according to whether patients undergo ablation or cystectomy. The evidence remains inconclusive regarding whether sclerotherapy is better than cystectomy in terms of ovarian reserve. The recurrence rates appear to be similar between sclerotherapy and cystectomy. There is not yet concrete evidence that sclerotherapy helps to improve the pregnancy rate via in vitro fertilization in comparison to cystectomy or no sclerotherapy.

Transient Simulations of Concrete Ablation due to a Release of Molten Core Material (방출된 노심용융 물질에 의한 콘크리트 침식 천이 모의)

  • Kim, H.Y.;Park, J.H.;Kim, H.D.;Kim, S.W.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3491-3496
    • /
    • 2007
  • If a molten core is released from a reactor vessel into a reactor cavity during a severe accident, an important safety issue of coolability of the molten core from top-flooding and concrete ablation due to a molten core concrete interaction (MCCI) is still unresolved. The released molten core debris would attack the concrete wall and basemat of the reactor cavity, which will lead to inevitable concrete decompositions and possible radiological releases. In a OECD/MCCI project scheduled for 4 years from 2002. 1 to 2005. 12, a series of tests were performed to secure the data for cooling the molten core spread out at the reactor cavity and for the 2-D long-term core concrete interaction (CCI). The tests included not only separate effect tests such as a melt eruption, water ingression, and crust failure tests with a prototypic material but also 2-D CCI tests with a prototypic material under dry and flooded cavity conditions. The paper deals with the transient simulations on the CCI-2 test by using a severe accident analysis code, CORQUENCH, which was developed at Argonne National Laboratory (ANL). Similar simulations had been already per for me d by using MELCOR 1.8.5 code. Unlike the MELCOR 1.8.5, the CORQUENCH includes a melt eruption mode I and a newly developed water ingression model based on the water ingression tests under the OECD/MCCI project. In order to adjust the geometrical differences between the CCI-2 test (rectangular geometry) and the simulations (cylindrical geometry), the same scaling methodology as used in the MELCOR simulation was applied. For the direct comparison of the simulation results, the same inputs for the MELCOR simulation were used. The simulation results were compared with the previous results by using MELCOR 1.8.5.

  • PDF

Evaluation of MCCI Behaviors in the Calandria Vault of CANDU-6 Plants Using CORQUENCH Code (CORQUENCH 코드를 활용한 중수로 calandria vault에서의 MCCI 거동 분석)

  • Seon Oh YU
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.90-100
    • /
    • 2021
  • Molten corium-concrete interaction (MCCI) is one of the most important phenomena that can lead to the potential hazard of late containment failure due to basemat penetration during a severe accident. In this study, MCCI analytical models of the CORQUENCH code were prepared through verification calculations of several experiments, which had been performed using concrete types similar to those of the calandria vault floor in CANDU-6 plants. The behaviors of thermal-hydraulic variables related to MCCI phenomena were analyzed under the conditions of dry floor and water flooding during the severe accident stemming from a hypothetic station blackout. Uncertainty analyses on the ablation depth were also carried out. It was estimated that the concrete ablation was not interrupted due to the continuous MCCI process under the dry condition but was terminated within 24 hours under the water flooding condition. It was confirmed that the water flooding as a mitigating action was effective to achieve the quenching and thermal stabilization of the melt discharged from the calandria vessel, showing that the present models are capable of reasonably simulating MCCI phenomena in CANDU-6 plants. This study is expected to provide the technical bases to the accident management strategy during the late-phase severe accidents.

The influence of the water ingression and melt eruption model on the MELCOR code prediction of molten corium-concrete interaction in the APR-1400 reactor cavity

  • Amidu, Muritala A.;Addad, Yacine
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1508-1515
    • /
    • 2022
  • In the present study, the cavity module of the MELCOR code is used for the simulation of molten corium concrete interaction (MCCI) during the late phase of postulated large break loss of coolant (LB-LOCA) accident in the APR1400 reactor design. Using the molten corium composition data from previous MELCOR Simulation of APR1400 under LB-LOCA accident, the ex-vessel phases of the accident sequences with long-term MCCI are recalculated with stand-alone cavity package of the MELCOR code to investigate the impact of water ingression and melt eruption models which were hitherto absent in MELCOR code. Significant changes in the MCCI behaviors in terms of the heat transfer rates, amount of gases released, and maximum cavity ablation depths are observed and reported in this study. Most especially, the incorporation of these models in the new release of MELCOR code has led to the reduction of the maximum ablation depth in radial and axial directions by ~38% and ~32%, respectively. These impacts are substantial enough to change the conclusions earlier reached by researchers who had used the older versions of the MELCOR code for their studies. and it could also impact the estimated cost of the severe accident mitigation system in the APR1400 reactor.

Scoping Analysis of MCCI (Molten Core Concrete Interaction) at Plant Scale Using CORQUENCH Code (CORQUENCH 코드를 사용한 실규모 원자로의 노심용융물과 콘크리트 상호반응 해석)

  • Kim, Hwan-Yeol;Park, Jong-Hwa
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.268-271
    • /
    • 2008
  • If a reactor vessel is failed to retain a molten corium in a postulated severe accident, the molten corium is released outside the reactor vessel into a reactor cavity. The molten corium would attack the concrete wall and basemat of the reactor cavity, which may lead to inevitable concrete decompositions and possible radiological releases. In the OECD/MCCI project, a series of tests were performed to secure the data for cooling the molten corium spread out at the reactor cavity and for the long-term CCI (Core Concrete Interaction). Also, a MCCI (Molten Core Concrete Interaction) analysis code, CORQUENCH was upgraded at Argonne National Laboratory with embedding the new models developed for the tests. This paper deals with analyses of MCCI at plant scale under the conditions of top flooding using the upgraded CORQUENCH code. The modeling approach is briefly summarized first, followed by presentation of a validation calculation that illustrates the predicative capability of the modeling tool. With this background in place, the model is then used to carry out a parametric set of scoping calculations that define approximate coolability envelopes for the LCS (Limestone Common Sand) concrete that has been evaluated in the OECD/MCCI project.

  • PDF

Corium melt researches at VESTA test facility

  • Kim, Hwan Yeol;An, Sang Mo;Jung, Jaehoon;Ha, Kwang Soon;Song, Jin Ho
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1547-1554
    • /
    • 2017
  • VESTA (Verification of Ex-vessel corium STAbilization) and VESTA-S (-small) test facilities were constructed at the Korea Atomic Energy Research Institute in 2010 to perform various corium melt experiments. Since then, several tests have been performed for the verification of an ex-vessel core catcher design for the EU-APR1400. Ablation tests of an impinging $ZrO_2$ melt jet on a sacrificial material were performed to investigate the ablation characteristics. $ZrO_2$ melt in an amount of 65-70 kg was discharged onto a sacrificial material through a well-designed nozzle, after which the ablation depths were measured. Interaction tests between the metallic melt and sacrificial material were performed to investigate the interaction kinetics of the sacrificial material. Two types of melt were used: one is a metallic corium melt with Fe 46%, U 31%, Zr 16%, and Cr 7% (maximum possible content of U and Zr for C-40), and the other is a stainless steel (SUS304) melt. Metallic melt in an amount of 1.5-2.0 kg was delivered onto the sacrificial material, and the ablation depths were measured. Penetration tube failure tests were performed for an APR1400 equipped with 61 in-core instrumentation penetration nozzles and extended tubes at the reactor lower vessel. $ZrO_2$ melt was generated in a melting crucible and delivered down into an interaction crucible where the test specimen is installed. To evaluate the tube ejection mechanism, temperature distributions of the reactor bottom head and in-core instrumentation penetration were measured by a series of thermocouples embedded along the specimen. In addition, lower vessel failure tests for the Fukushima Daiichi nuclear power plant are being performed. As a first step, the configuration of the molten core in the plant was investigated by a melting and solidification experiment. Approximately 5 kg of a mixture, whose composition in terms of weight is $UO_2$ 60%, Zr 10%, $ZrO_2$ 15%, SUS304 14%, and $B_4C$ 1%, was melted in a cold crucible using an induction heating technique.

Comparison of Urine Iodine/Creatinine ratio between Patients following Stringent and Less Stringent Low Iodine Diet for Radioiodine Remnant Ablation of Thyroid Cancer (갑상선암의 방사성요오드치료를 위한 저요오드식이 방법 차이에 따른 소변 중 요오드/크레아티닌 비의 비교)

  • Roh, Jee-Ho;Kim, Byung-Il;Ha, Ji-Su;Chang, Sei-Joong;Shin, Hye-Young;Choi, Joon-Hyuk;Kim, Do-Min;Kim, Chong-Soon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.322-326
    • /
    • 2006
  • A low iodine diet (LID) for $1{\sim}2$ weeks is recommended for patients who undergoing radioiodine remnant ablation. However, the LID educations for patients are different among centers because there is no concrete recommendation for protocol of LID. In this investigation, we compared two representative types of LID protocols performed in several centers in Korea using urine iodine to creatinine ratio (urine I/Cr). Methods: From 2006, April to June, patients referred to our center for radioiodine remnant ablation of thyroid cancer from several local hospitals which had different LID protocols were included. We divided into two groups, stringent LID for 1week and less stringent LID for 2 weeks, then measured their urine I/Cr ratio with spot urine when patients were admitted to the hospital. Results: Total 27 patients were included in this investigation (M:F=1:26; 13 in one-week stringent LID; 14 in two-week less stringent LID. Average of urine I/Cr ratio was $127.87{\pm}78.52{\mu}g/g$ in stringent LID for 1 week, and $289.75{\pm}188.24{\mu}g/g$ in less stringent LID for 2 weeks. It was significantly lower in stringent LID for 1 week group (p=0.008). The number of patients whose urine I/Cr ratios were below $100{\mu}g/g$ was 6 of 13 in stringent LID for 1 week group, and 3 of 14 in less stringent LID for 2 weeks group. Conclusion: Stringent LID for 1 week resulted in better urinary I/Cr ratio in our investigation compared with the other protocol. However it still resulted in plenty of inadequate range of I/Cr ratio, so more stringent protocol such as stringent LID for 2 weeks is expected more desirable.