• Title/Summary/Keyword: Concept of Radiation

Search Result 212, Processing Time 0.023 seconds

Derivation of a Monte Carlo Estimator for Dose Equivalent (몬테칼로법을 위한 선량당량 산정법의 도출)

  • Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.2
    • /
    • pp.89-95
    • /
    • 1985
  • An alternative estimator for dose equivalent was derived. The original LET distribution concept was transformed into a charged particle fluence spectrum concept along with the definition of an average quality factor named slowing-down averaged quality factor by adopting the continuous slowing down approximation. With the alternative estimator, the dose equivalent delivered into a receptor located in a given radiation field can be directly and conveniently estimated in a Monte Carlo procedure. The slowing-down averaged quality factors for the energy range below 10 MeV were evaluated and tabulated for the charged particles which may be generated from the interactions of neutron with the nuclei composing soft tissue.

  • PDF

Radiation Hormesis: Incredible or Inevitable\ulcorner

  • Ducoff, Howard-S
    • Animal cells and systems
    • /
    • v.6 no.3
    • /
    • pp.187-193
    • /
    • 2002
  • It has long been recognized that exposure to low levels of toxic chemicals could have beneficial effects, such as increased resistance to related chemicals or stimulation of growth or development. The notion of radiation hormesis, that exposure to low levels of ionizing radiation could produce beneficial effects, developed seriously in the late 1950’s, and was, to most radiation scientists, incredible. This was due in pan to the then prevailing ideas of radiobiological mechanisms, in part to the sweeping generalizations made by the leading proponents of the radiation hormesis concept, and in pan to the many failures to confirm reports of beneficial effects. More recent understanding of the mechanisms of radiation damage and repair, and discoveries of induction of gene expression by radiation and other genotoxic agents [the adaptive response] make it seem inevitable that under suitable conditions, irradiation will produce beneficial effects.

A Dual Radiation Monitoring System Ror Robot Working in High Radiation Field (고방사선장내 작업 로봇용 이중 방사선 감지 시스템)

  • Lee Nam-Ho;Cho Jai-Wan;Kim Seung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.556-558
    • /
    • 2005
  • The effect of high irradiation on inspection systems in a nuclear power plant can be severe, especially to electronic components such as control hoards. The effect may lead to a critical malfunction or trouble to a underwater robot for inspection and maintenance of nuclear reactor. However, if information on the total accumulated dose on the sensitive parts of the robot is available, a prediction of robot's behavior in radiation environments becomes possible. To know how much radiation the robot has encountered, a dosimeter to measure the total accumulated dose is necessary. This paper describes the development effort of a dual radiation monitoring system using a SiC diode as a dose-rate meter and a p-type power MOSFET as a dose meter. This attempt using two sensors which detect same radiation improves reliability and stability at high intensity radiation detection in nuclear facilities. It uses the concept of diversity and redundancy.

A Study on Dose Sensitivity according to Position Variance in Extremities Radiation Therapy with Water Bolus (사지의 방사선 치료에 사용하는 water bolus의 적용 시 치료부위의 위치 변화에 따른 방사선 선량분포의 민감도 연구)

  • Seo, Jeong Min
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.199-206
    • /
    • 2015
  • The purpose of this study was to investigate radiation dose sensitivity due to displacement of human extremities in the water bolus box on radiation therapy. Water bolus box and human thigh with femur bone were constructed in computerized radiation therapy planning system to verify the absorbed dose. Two 6MV X-ray beams were irradiated bilaterally into water bolus box and then radiation dose were calculated each situation at displacement of middle axis of thigh from the center in water bolus box to right and left direction. Absorbed dose of thigh and femur bone increased by the distance of displacement. The maximum dose of thigh even increased 20% over than prescribed dose. This is in contrast to conventional concept of dose distribution in water bolus box. Based on this result, displacement of body site in the water bolus box have to be averted during radiation therapy.

The development of radiation lifetime measuring module for KAEROT/m2 (KAEROT/m2용 방사선 수명 측정모듈 개발)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.793-796
    • /
    • 2003
  • The electronics of a mobile robot ill nuclear facilities is required to satisfied the reliability to sustain survival in its radiation environment. To know how much radiation the robot has been encountered to replace sensitive electronic parts, a dosimeter to measure total accumulated dose is necessary. Among many radiation dosimeters or detectors, semiconductor radiation sensors have advantages in terms of power requirements and their sires over conventional detectors. This paper describes the use of the radiation-induced threshold voltage change of a commercial power pMOSFET as an accumulated radiation dose monitoring mean and that of the photo-current of a commercial PIN Diode as a dose-rate measurement mean. Commercial p-type power MOSFETs and PIN Diodes were tested in a Co-60 gamma irradiation facility to see their capabilities as radiation sensors. We found an inexpensive commercial power pMOSFET that shows good linearity in their threshold voltage shift with radiation dose and a PIN diode that shows good linearity in its photo-current change with dose-rate. According to these findings, a radiation hardened hybrid electronic radiation dosimeter for nuclear robots has been developed for the first time. This small hybrid dosimeter has also an advantage in the point of view of reliability improvement by using a diversity concept.

  • PDF

Modal Radiation Efficiency of Swaged Panels

  • Lee, Jong-Hwa;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.3E
    • /
    • pp.132-139
    • /
    • 2002
  • Swaging technique is frequently used to stiffen thin panels for reducing the vibration levels of the machine or vehicle structure. Because the internal constraints imposed by swages can distort the mode shapes of panels, they affect the sound radiation characteristics. In this paper, the radiated sound field generated by the idealized and baffled finite swaged panel is studied, in which the curved swage section is modeled as an incomplete cylindrical shell. The modal radiation efficiencies are predicted using the transfer matrix concept and compared with those of flat panels. It is observed that the radiation efficiencies of the swaged vibrational modes can increase slightly for frequencies below the critical frequency, while increase of radiation efficiency depends on the mode shapes and other related structural parameters.

Radiological Safety Perception Change after Spatial Dose Measurement of Radiology Department Students (방사선학과 학생들의 공간선량 측정 경험이 방사선 안전 인식에 미치는 영향)

  • Moon, Jae Mi;Park, Sang Tae;Yu, Ji Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.174-180
    • /
    • 2015
  • There are currently many research papers on the knowledge, perceptions and actions of radiation-related staff, but hardly any papers on radiation major students in college who are to be staff members of radiation related jobs in the future. It is of course important to understand the perceptions of staff working on the lines and change their knowledge and perceptions, but in the long term it seems more efficient to understand those who are in the stage of being educated to be staff members-their knowledge and perception of radiation so that ultimately they can attain the right kind of understanding. Therefore the aim of this study is to grasp the pre-radiation staff's basic concept of radiation and space dose, their understanding of radiation safety based on this, and whether there is a change in their perception before and after the space dose measurement experiment; in the end this is to see if the space dose measurement experiment is effective in changing perception on radiation safety. This study took as its subject 64 students majoring radiation in college, I.e. pre-radiation staff members, and gauged their basic conceptualization of radiation, understanding of space dose, and understanding of radiation safety; in the X-ray room within the department the students were asked to measure space dose for themselves, so as to see whether there was a change in their understanding of radiation safety before and after the experiment, according to their understanding of the basic concept of radiation and of space dose. As a result of the space dose measurement experiment, students' increased basic knowledge of concept of radiation and understanding of the dangers of space dose were noteworthy, and accordingly their understanding of radiation safety became stricter and more conservative. In spite of this, their work ethic stayed in the lead of their understanding of radiation safety; this implies the need of a more departmentalized safety education program. Therefore instead of safety education that simply uses visual-audial material in a kind of lecture, I suggest here that there be a more experiential safety education program that enables learners to try out space dose measurement experiments for themselves, a work ethic education that aims for a conventional point of view towards radiation safety as well as a stern attitude.

Gonadotrophin Releasing Hormone Analogues for Ovarian Function Preservation in Young Females Undergoing Chemotherapy

  • Bansal, Anshuma;Patel, Firuza Darius;Rai, Bhavana;Dhanireddy, Bhaswanth;Sharma, Suresh Chand
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2185-2190
    • /
    • 2014
  • Chemotherapy has significantly improved the prognosis of cancer patients with various malignancies. However, female patients, especially those whoich are premenopausal, suffer from significant chemotherapy induced ovarian function impairment, which decreases their quality of life. Many new techniques for ovarian preservation have been established in recent years. Although the use of gonadotrophin releasing hormone analogues (GnRHa) for this purpose is not a new concept, its effectiveness in protection of ovarian function is still debatable. This article deals with studies and metaanalyses which have been undertaken in the past, demonstrating the impact of GnRHa in ovarian function preservation, and whether their use can be implemented in routine practice.

Generation of a plane-wave field by point focusing of acoustic potential energy on the radiation sphere in the wavenumber domain (파수 영역의 방사 구면에서 음향 에너지 집중을 통한 평면파 생성 방법)

  • Chang, Ji-Ho;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.820-823
    • /
    • 2007
  • In the wavenumber domain, each point on a radiation sphere indicates a plane wave of the frequency corresponding to radius of the sphere and the position on the sphere shows propagating direction of the plane wave. This concept is extended from the research by Choi[1] where he focus acoustic potential energy at a point on a radiation sphere. Here we propose the method to focus the energy at a point on the radiation sphere, as a result, we can easily generate a plane wave which propagates to any direction that we want.

  • PDF