• 제목/요약/키워드: Concentric annulus

검색결과 67건 처리시간 0.025초

안쪽축이 회전하는 환형관내 비뉴튼 유체의 천이 유동 연구 (Transitional Flow study on non-newtonian fluid in a Concentric Annulus with Rotating Inner Cylinder)

  • 김영주;황영규;권혁정;서병택;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.324-329
    • /
    • 2001
  • This experimental study concerns the characteristics of a transitional flow in a concentric annulus with a diameter ratio of 0.52, whose outer cylinder is stationary and inner one rotating. The pressure losses and skin-friction coefficients have been measured for the fully developed flow of $0.1\sim0.4%$ aqueous solution of sodium carbomethyl cellulose (CMC), respectively at inner cylinder rotational speed of $0\sim600rpm$. The transitional flow has been examined by the measurement of pressure losses to reveal the relation of the Reynolds and Rossby numbers with the skin-friction coefficients. The present results show that the skin-friction coefficients have the significant relation with the Rossby numbers, only for laminar regime. The occurrence of transition has been checked by the gradient changes of pressure losses and skin-friction coefficients with respect to the Reynolds numbers. The increasing rate of skin-friction coefficients due to the rotation in uniform for laminar flow regime, whereas it is suddenly reduced for transitional flow regime and, then, is gradually declined for turbulent flow regime. Consequently, the critical(axial-flow) Reynolds number decrease as the rotational speed increases. Thus, the rotation of inner cylinder promotes the early occurrence of transition due to the onset of taylor vortices.

  • PDF

회전하고 있는 바깥쪽 실린더를 갖고 있는 수평 원주형 환형 내에서의 공기의 혼합 대류 (Mixed convection of air in a horizontal cylindrical annulus with rotating outer cylinder)

  • 유주식
    • 대한기계학회논문집B
    • /
    • 제21권4호
    • /
    • pp.551-561
    • /
    • 1997
  • Mixed convection of air in a horizontal concentric cylindrical annulus is investigated numerically. Isothermal boundary conditions are prescribed at the inner and outer cylinders, with the inner cylinder being warmer. The forced flow is induced by the outer cylinder which is rotating slowly with constant angular velocity with its axis at the center of the annulus. The effect of the forced flow on the flow pattern and heat transfer of natural convection is investigated for the annulus of (inner-cylinder radius/gap width) = 1. There appear two eddies, one eddy or no eddy according to the Rayleigh and Reynolds numbers. Map of the three flow regimes is constructed on the Ra-Re plane. (author). 28 refs., 9 figs., 2 tabs.

안쪽축이 회전하는 동심환형관내 고-액 2상 유동연구 (Solid-liquid 2phase flow in a concentric annulus with rotation of the inner cylinder)

  • 김영주;한상목;우남섭;황영규
    • 에너지공학
    • /
    • 제18권2호
    • /
    • pp.87-92
    • /
    • 2009
  • 본 논문은 안쪽축이 회전하는 동심환형관 물과 비뉴튼유체의 고-액 2상 유동연구를 수행하였다. 점탄성유체의 유변학은 굴착구멍의 청결, 입자의 밖으로 수송하는 등 여러 가지 응용에 중요하다. 연구에서 투명한 아크릴관은 고체입자의 이동을 관찰하기 위하여 사용하였다. 환형관 속도는 0.3m/s에서 2.0m/s로 변한다. 머드시스템은 물과 CMC 수용액을 혼합하여 사용하였다. 연구에서 고려된 주요 변수들은 축회전속도, 유체 유동영역과 입자 주입율이다. 입자이송속도와 압력강하는 유체유량(Q, LPM)이 5~30의 범위에서 측정하였다. 물과 0.2% CMC 수용액에서 고체입자의 농도가 높을수록 압력손실이 커짐을 알 수 있었다.

2개의 수직휜이 부착된 내관으로부터 환상공간내의 자연대류 열전달 (Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins)

  • 정태현;정한식;권순석
    • 대한기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.654-660
    • /
    • 1991
  • Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins has been studied for the effects of dimensionless fin length and Rayleigh number. The maximum local Nusselt number of inner tube was obtained at .theta. = 145.deg. and that of outer cylinder at .theta. = 0.deg. for the case of $l_{F}$=0.3 Local Nusselt number distributions for the lower fins show higher values than that of the upper fins. The mean Nusselt number of inner tube was increased with the values of dimensionless fin length. The mean Nusselt number can be represented in an exponential function of Grashof number at various fin lengths. As compared with experimental and numerical results, isotherms and local Nusselt number show good agreement.t.

Slim hole 환형관내 고-액 2상 유동에 관한 연구 (Solid-liquid two phase helica l flow in a Rotating Annulus)

  • 한상목;우남섭;황영규;김영주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.369-372
    • /
    • 2008
  • An experimental study is carried out to study two-phase vertically upward hydraulic transport of solid particles by water in a vertical and inclined (0${\sim}$60 degree) concentric annulus with rotation of the inner cylinder. Rheology of particulate suspensions in shear-thinning fluids is of importance in many applications such as particle removal from surfaces, transport of proppants in fractured reservoir and cleaning of drilling holes, and so on. Annular fluid velocities varied from 0.2 m/s to 1.5 m/s for the actual drilling operational condition. Macroscopic behavior of solid particles, averaged flow rate, and particle rising velocity are observed. Main parameters considered in this study were radius ratio, inner-pipe rotary speed, fluid flow regime, and particle injection rate. For both water and CMC solutions, the higher the concentration of the solid particles is, the larger the pressure gradients become

  • PDF

대체냉매 관내 열전달특성 시험을 위한 동심이중원관의 환상유로의 열전달계수 (Heat Transfer Coefficients of Concentric Annuli for Testing Heat Transfer Characteristics of Alternative Refrigerants in Tubes)

  • 김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제32권1호
    • /
    • pp.63-67
    • /
    • 2021
  • Accurate measurements of the heat transfer coefficients of concentric annular space for the test section is important to measure the tube-side heat transfer coefficients of working fluids. This paper presents the annular side heat transfer coefficients of concentric annuli with variation of tube diameter ratios using Wilson plot method. The test facility has a straight, horizontal test section with an active length of 3.0 m. Inner/outer diameters of test tubes are 7.0/7.5 and 8.0/8.56 mm, respectively. An outer diameter of annulus side is 16.0 mm. The test results show that convective heat transfer coefficients in annuli increase with annular diameter ratio. The correlations for convective heat transfer coefficients in annuli are also developed.

동심환내에서 회전하는 실린더에 작용하는 유체동하중 (Fluid-dynamic Forces Acting on the Rotating Inner Cylinder In Concentric Annulus)

  • 심우건
    • 소음진동
    • /
    • 제11권3호
    • /
    • pp.428-436
    • /
    • 2001
  • The rotating inner cylinder executes a periodic translational motion in concentric annulus while the outer one is stationary. In the study of flow-induced vibrations and relaxed instabilities, it is of interest to evaluate the fluid-dynamic forces acting on the rotating inner cylinder. In the present work, the governing equations for the confined flow are expressed as Navier-Stokes equations, including the steady and unsteady terms. The fluid parameters for steady flow generated by the rotating cylinder are determined analytically while the unsteady ones by the oscillatory motion are evaluates by a numerical method based on the spectral collocation method. In order to validate the numerical approach, the numerical results are compared wish the analytical ones given by existing theories, for simple cases where the both approaches are applicable. Good agreement was found between the results. It is found the effects of the Reynolds number, defined by rotating velocity, on the fluid-dynamic forces are important for the case of relatively low oscillatory Reynolds number, defined by oscillatory frequency : j.e., in case of $Re_\omega\gg Re_S$.

  • PDF

뉴튼 및 비뉴튼 유체의 헬리컬 유동에 관한 연구 (A Study on the Helical Flow of Newtonian and non-Newtonian fluid)

  • 김영주;김철수;황영규
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.8-15
    • /
    • 2005
  • This study concerns the characteristics of helical flow in a concentric and eccentric annulus with a diameter ratio of 0.52 and 0.9, whose outer cylinders are stationary and inner ones are rotating. Pressure losses and skin friction coefficients have been measured for fully developed flows of water and $0.2\%$ aqueous of sodium carboxymethyl cellulose(CMC), respectively, when the inner cylinder rotates at the speed of $0\~500$ rpm. The effect of rotation on the skin friction coefficient is significantly dependent on the flow regime. In all flow regimes, the skin friction coefficient is increased by the inner cylinder rotation. This study shows the change of skin friction coefficient and wall shear stress corresponding to the variation of rotating speed of the inner cylinder, radius ratio, eccentricity, and working fluids.

동심원내에서 진동하는 내부 실린더에 작용하는 유체유발력의 근사적 해법 (An Approximate Analytical Method for Hydrodynamic Forces on Oscillating Inner Cylinder in Concentric Annulus)

  • 심우건
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.861-869
    • /
    • 1997
  • An approximate analytical method has been developed for estimating hydrodynamic forces acting on oscillating inner cylinder in concentric annulus. When the rigid inner cylinder executes translational oscillation, fluid inertia and damping forces on the oscillating cylinder are generated by unsteady pressure and viscous skin friction. Considering the dynamic-characteristics of unsteady viscous flow and the added mass coefficient of inviscid fluid, these hydrodynamic forces including viscous effect are dramatically simplified and expressed in terms of oscillatory Reynolds number and the geometry of annular configuration. Thus, the viscous effect on the forces can be estimated very easily compared to an existing theory. The forces are calculated by two models developed for relatively high and low oscillatory Reynolds numbers. The model for low oscillatory Reynolds number is suitable for relatively high ratio of the penetration depth to annular space while the model for high oscillatory Reynolds number is applicable to the case of relatively low ratio. It is found that the transient ratio between two models is approximately 0.2~0.25 and the forcea are expressed in terms of oscillatory Reynolds number, explicity. The present results show good agreements with an existing numerical results, especially for high and low penetration ratios to annular gap.

  • PDF