• 제목/요약/키워드: Concentric Tube

검색결과 86건 처리시간 0.02초

Hardy-Cross법을 이용한 $CO_2$ 냉동기용 내부열교환기의 열전달 특성 연구 (Analysis of Heat Transfer Characteristics of Internal Heat Exchanger for $CO_2$ Refrigerator using the Hardy-Cross Method)

  • 강희동;김욱중;서태범
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.1-7
    • /
    • 2005
  • The heat transfer characteristics of an internal heat exchanger for $CO_2$ refrigeration cycle are numerically investigated. The numerical model is verified using the published experimental results for the concentric tube type internal heat exchanger. The Hardy-Cross Method gives very good agreement between the calculation and experimental results on the heat transfer rates and exit temperatures. Also, appropriate combination of heat transfer correlations is found. The operating parameters of the heat exchanger are calculated at transcritical region of $CO_2.$ The heat transfer rate of the counter flow type heat exchanger shows the $32\%$ greater than that of the parallel flow type heat exchanger. The increase of heat exchanger length enhances the heat transfer rate. The thermodynamic characteristics and heat transfer coefficient of $CO_2$ in the internal heat exchanger are estimated.

R134a, R152a, R22/142b를 이용한 냉동기의 성능실험 (Performance of Refrigerator Using R134a, R152a and R22/142b)

  • 장영수;신지영;노승탁
    • 설비공학논문집
    • /
    • 제6권1호
    • /
    • pp.39-46
    • /
    • 1994
  • Experiments on the performance of refrigeration system using alternatives to R12 are carried out. The condenser and the evaporator are concentric-tube heat exchangers of counter-flow type and the compressor is driven by a variable speed motor. In this study, R134a, R152a, R22/142b(50 : 50 by mass) are adopted as alternatives to R12. Tests are performed by varying the inlet and outlet temperatures of secondary fluids of evaporator and condenser under the condition of constant compressor speed, degree of superheating and degree of subcooling. Results show that R134a has refrigeration capacity close to that of R12 and requires the greatest compressor power compared with that of others. And the system using R152a shows the best performance from the viewpoint of refrigeration capacity, compressor power and coefficient of performance. R22/142b is superior to R12 in the above points.

  • PDF

광섬유 대량생산용 인출퍼니스 내 유리섬유 인출공정의 전산해석 (COMPUTATIONAL STUDY OF GLASS FIBER DRAWING PROCESS IN A DRAW FURNACE OF OPTICAL FIBER MASS MANUFACTURING SYSTEM)

  • 김경진;곽호상;김동주
    • 한국전산유체공학회지
    • /
    • 제18권4호
    • /
    • pp.69-73
    • /
    • 2013
  • Mass manufacturing of optical fiber includes the process of very thin glass fiber drawing by heating and softening the high purity silica preform and applying the draw tension on the softened tip of preform neck-down profile in a draw furnace. In this computational study, this process is numerically modeled with simplified geometry of the draw furnace which is comprised of essential parts such as concentric graphite heater, muffle tube, and insulation surrounding the heater. The iterative computational scheme is employed between one-dimensional model of neck-down profile prediction and two-dimensional axisymmetric thermo-fluid CFD computation of radiative heating and working gas convection. The computational results show the experimentally observed neck-down profile in heated section of preform, while yielding the reasonable values of draw tension and heater wattage. Also, this study analyzes and discusses the effects of heating conditions such as heater length and temperature on several important aspects of glass fiber drawing process.

실내설정온도에 따른 태양열 하이브리드 열펌프 시스템 운전특성에 대한 실험적 연구 (Experimental Study on the Operating Characteristics of a Solar Hybrid Heat Pump System according to Indoor Setting Temperature)

  • 김원석;조홍현
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.50-58
    • /
    • 2010
  • Experimental study on the operating characteristics of a solar hybrid heat pump system according to indoor setting temperature were carried out during spring and winter season. The system was consisted of a concentric evacuated tube solar collector, heat medium tank, heat storage tank, and heat pump. As a result, the heating load was increased by 21.1% when the indoor setting temperature rose by 2oC for the same ambient temperature. Besides, the spring season had good outdoor conditions compared to the winter season, therefore the heating load was reduced and heat gain by collector increased, relatively. In case of the winter season, the solar fraction was shown less than 10% because the heat losses of system and space increased considerably. The solar fraction decreased significantly as the indoor setting temperature increased.

그루브형 히트파이프를 갖는 이중진공관형 태양열 집열기의 열전달특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Characteristics of a Grooved Heat Pipe for Solar Collector)

  • 김병기;정경택;장환영;서정세
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.965-969
    • /
    • 2006
  • This study investigated heat transfer characteristics between absorber and heat pipe used to extract heat from concentric evacuated tubular collectors. In order to experiment, T-type thermocouples are attached to a evaporator of heat pipe and absorber of inner tube. A wall temperature distribution of absorber and heat pipe were carried out by experimental method under actual various ir-radiance and outdoor conditions. As a result, As to increase an irradiance, a wall temperature of absorber and heat pipe is gradually increased. The heat pipe was required about 20min to obtain steady state operation after start up and operates stable during various irradiance conditions. And the collector efficiency was about $50{\sim}70%$ when a mass flow rate is about $1.3{\ell}/min$.

  • PDF

고강도콘크리트충전 각형강관장주의 내력에 관한 실험적 연구 (An Experimental Study on Stength of Slender Square Tube Columns Filled with High Strength Concrete)

  • 서성연;정진안
    • 한국강구조학회 논문집
    • /
    • 제14권4호
    • /
    • pp.471-479
    • /
    • 2002
  • 본 논문에서는 고강도콘크리트충전 각형강관장주에 대한 실험결과와 탄소성해석결과를 비교분석했다. 실험체는 모두 고강도콘크리트 충전 각형강관장주로 18개를 제작하였으며, 편심비에 따라 중심 및 편심가력하였다. 본 연구의 주요 파라메타는 단면폭에 대한 유효좌굴 길이의 비($L_K$/D)= 4, 8, 12, 24, 30와 가력편심비(e)=0, k, 3k이다. 본 논문에서 고강도콘크리트 충전 각형강관장주의 내력에 관한 해석 및 실험을 통하여 다음과 같은 결과를 얻었다. $L_K$/D=12 이하의 고강도콘크리트충전 각형강관단주는 콘크리트 감소계수 $c{\gamma}u=0.85$를 고려한 전소성내역에 도달했으나, $L_K$/D=18 이상의 장주실험체는 콘크리트 감소계수를 고려한 전소성내력에 도달하지 않았다. 실험에 의한 고강도콘크리트충전 각형강관장주의 탄소성거동은 제안된 해석치의 종국내력$N_{ASSUMED}$과 비교적 양호한 접근을 보여주었다. 콘크리트 압축강도의 감소계수 $c{\gamma}u=0.85$를 고려하지 않은 CFT설계기준과 고강도 콘크리트를 충전한 각형강관기둥의 실험결과치는 비교적 잘 일치함을 알 수 있었다.