• Title/Summary/Keyword: Concentration device

Search Result 971, Processing Time 0.023 seconds

Synthesis of Flake Type Micro Hollow Silica Using Mg(OH)2 Inorganic Template

  • Lee, Ji-Seon;Noh, Kyeong-Jae;Moon, Seong-Cheol;Lee, Young-Chul;Lee, Seong-Eui
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.3
    • /
    • pp.222-227
    • /
    • 2017
  • Flake-type micro hollow silica was synthesized by precipitation method using an $Mg(OH)_2$ inorganic template and sodium silicate and ammonium sulfate as the silica precursors. We investigated the effects of the silica precursor concentration on the shape, shell thickness, and surface of the hollow silica. When the concentration of the silica precursor was 0.5 M, the hollow silica had a smooth and translucent thin shell, but the shell was broken. On the other hand, the shell thickness of the hollow silica changed in the range of 12 nm to 18 nm with the increase of the precursor concentration from 0.7 M to 1.1 M. Simultaneously, unintended spherical silica satellites were created on the shell surface. The number of satellites and the size rose according to the increased concentration of silica precursor. The reason for the formation of spherical silica satellites is that the $NH_4OH$ nucleus generated in the synthesis of hollow silica acted as another silica reaction site.

The Luminescent Characteristics of C545T Doped OLED Devices (C545T가 첨가된 OLED 소자의 발광특성)

  • Ju, Sung-Hoo;Yang, Jae-Woong
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.2
    • /
    • pp.77-81
    • /
    • 2007
  • To investigate the characteristics of green light-emitting OLED device, C545T material with $Alq_3$ was doped in the OLED device of $ITO(1500)/2-TNATA(400{\AA})/NPB(80{\AA})/Alq_3:C545T(160{\AA})/Alq_3(240{\AA})/LiF(3{\AA})/Al(2400{\AA})$ structure, which was used as a activator at the respective concentration of 0.5 vol.%, 1 vol.%, 2 vol.% and 3 vol.%. It was observed from the experiments that the device efficiency firstly increased with the increase of C545T concentration and the maximum efficiency of 10.9 cd/A and 4.28 lm/W was obtained at C545T concentration of 1 vol.%, and then the device efficiency decreased as the C545T activator concentration increased above 2 vol.% contents, while the longest lifetime of over 750 hours was obtained at C545T concentration of 1 vol.%.

Device Development of Mixture Concentration of Ethylene Glycol Antifreeze Coolant for Vehicles (자동차 에틸렌글리콜 부동액의 혼합 농도 측정 장치 개발)

  • Lee, Dae-Woong;Lee, Eun-Woung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.331-336
    • /
    • 2016
  • This study presents a coolant density calculation device and its corresponding method by using a mass flowmeter and the LabVIEW program. The method can be easily measured with a mixture of coolant and by calculating the percentage of ethylene-glycol without additional investment. The cooling water is very important in a vehicle to protect the engine, and the cooling performance is affected by the mixture concentration and coolant density. The coolant density calculation device measures the mixed concentration in the anti-freeze cooling mixture made from distilled water and ethylene-glycol in real time with the mass flowmeter that is commonly attached to the radiator or heater core. The calculation program for the mixture concentration percentage was developed using the LabVIEW software. The correlation between experimental results and the calculation was conducted for a range of temperature from 40 to $90^{\circ}C$ and by varying the mixture ratio of distilled water and ethylene-glycol. As a result, the anti-freeze coolant concentration in the volume percentage is able to monitor the coolant density in a timely basis by implementing a mixture concentration calculation program without the need for additional equipment investment. The results of the calculation for the mixture concentration level show a maximum 2.7% deviation compared to the experimental results.

Measurement of Gas Concentration and flow Rate Using Hot Wire (열선을 이용한 혼합기체의 농도와 유량의 측정)

  • Kim, Young-Han;Park, Jong-Jueng
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.5
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

Reduction of Particulate Matters Levels in Railway Cabins in Korea

  • Park, Duck-Shin;Kwon, Soon-Bark;Cho, Young-Min;Park, Eun-Young;Jeong, Woo-Tae;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.51-56
    • /
    • 2012
  • Objectives: High concentrations of airborne particulate matters (PM) can affect the health of passengers using public transportation. The objectives of this research were to develop a PM control system for a railway cabin and to evaluate the performance of the device under conditions of an actual journey. Methods: This study measured the concentrations of $PM_{10}$ and $PM_{2.5}$ simultaneously in a reference cabin and a cabin with the PM control device. Results: The average $PM_{10}$ concentration in the reference cabin was 100 ${\mu}g/m^3$, and the $PM_{10}$ concentration in the cabin with the control device was 79 ${\mu}g/m^3$. While the overall control efficiency of the control device was 15.4%, reduction was more effective for peak $PM_{10}$ concentration. However, $PM_{2.5}$ levels did not differ greatly between the reference cabin and the cabin with the control device. The ratio of $PM_{2.5}$ to $PM_{10}$ was 0.37. $PM_{10}$ concentrations in cabins were not associated with ambient concentrations, indicating that the main sources of $PM_{10}$ were present in cabins. Additionally, average $CO_2$ concentration in the cabins was 1,359 ppm, less than the maximum of 2,000 ppm set out by the Korean Ministry of Environment's guideline. The $CO_2$ concentration in cabins was significantly associated with the number of passengers: the in-cabin concentration = $23.4{\times}N+460.2$, where N is the number of passengers. Conclusions: Application of the PM control device can improve $PM_{10}$ concentration, especially at peak levels but not $PM_{2.5}$ concentration.

The Fabrication and Characterization of CODE MOSFET (CODE MOSFET 소자의 제작 및 특성)

  • 송재혁;김기홍;박영준;민홍식
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.6
    • /
    • pp.895-900
    • /
    • 1990
  • With the MOS device scailing down, the substrate concentration must increase in order to avoid punchthrough leakage current due to the DIBL(Drain Induced Barrier Lowering) effect. However the enhancement of the substrate concentration increases source, drain juntion capacitances and substrate current due to hot elelctron, degrading the speed characteristics and reliability of the MOS devices. In this paper, a new device, called CODE(Channel Only Dopant Enhancement) MOS, an its fabrication are proposed. By comparing the fabricated CODE MOSFET with the conventional device, the improvements on DIBL, substrate current and source, drain juntion capacitances are realized.

  • PDF

The development of a portable MO4- (M = 188Re or 99mTc) concentration device for extending the lifetime of RI generators

  • Choi, Kang-Hyuk;Park, Ul Jae;Kim, Jong Bum;Jang, Beom-Su
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.3-10
    • /
    • 2019
  • The activities per volume of $^{188}Re$ and $^{99m}Tc$ from their generators are dependent on the specific activity of their mother nuclides $^{188}W$ and $^{99}Mo$ respectively. After a particular lapse of time, the eluted RI activity is exponentially reduced and thus cannot satisfy the needs of clinical application. The purpose of this study is to develop a $^{188}Re$ and $^{99m}Tc$ concentration device with a compact size that can extend the period of use as well as conveniently concentrate the RI. We designed the concentration module by including two-different check valves that do not required any manual on-off operations. In these concentration process, cation exchange resin embedded with Ag and anion exchange resins were used. After completing the concentrating step, the recovering yield was identified to be more than 93% for $^{188}Re$ generators and 88% for $^{99m}Tc$ generators. Moreover, all these procedures were done within 5 min.

Comparison and Evaluation of Real Industry Color(RIC) Device and Spectrophotometer for the Colors of Dyed Fabrics (염색물의 Color에 따른 Real Industry Color(RIC) Device와 측색기의 비교분석 및 평가)

  • Bin, Soyoung;Hwang, Hyejin;Kim, Dongkwon;Park, Yooncheol;Park, Soonyoung;Jang, Eun-Hye;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.26 no.1
    • /
    • pp.39-44
    • /
    • 2014
  • To confirm the performance and benefit of the developed online E-commerce Real Industrial Color(RIC) device, cotton and polyester were dyed with selected 39 colors. The captured images of dyed cotton and polyester by using RIC device were compared with original samples and confirmed ${\Delta}E$ using a spectrophotometer and RIC device. Overall, visual comparison of the captured images was similar to the real dyed samples. In high concentration of dyeings, the color consistency between real samples and captured images was better than in lower color concentration of dyeings. Similarly, the result was almost the same when the developed RIC device was used since ${\Delta}E$ values of RIC device were smaller compared with spectrophotometer. In this regards, the RIC device developed up to date can be assumed that it is more influenced by the color rather than fabric materials.

A study on the influence of luminecent center on luminance in SrS:Ce electroluminescent devices (SrS:Ce EL소자에 있어서 발광중심이 휘도에 미치는 영향에 관한 연구)

  • Lee, Sang-tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.613-616
    • /
    • 2001
  • The effect of codopants on the electroluminescent properties for SrS-Ce based thin films was studied. The active layer was deposited by electron beam with sulfur The wavelength of eletroluminecence shifted with codopants and their concentrations. The intensity ratio of blue to green were found In the CeP-doped device, but the highest total intensity of luminance showed about 850cd/$m^2$ in the CeCl$_3$+KCL-doped device, which indicates that codopants are playing an important role of luminance. At any device, the luminance was the strongest at 0.2 mol% concentration among the concentration studied, suggesting the existence of optimum concentration. By post-annealing Luminance of most devices was improved, but the shift of wavelength was not observed.

  • PDF

Analysis of Breakdown Voltages of Double Gate MOSFET Using 2D Potential Model (이차원 전위분포모델을 이용한 이중게이트 MOSFET의 항복전압 분석)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1196-1202
    • /
    • 2013
  • This paper have analyzed the change of breakdown voltage for channel doping concentration and device parameters of double gate(DG) MOSFET using two dimensional potential model. The low breakdown voltage becomes the obstacle of power device operation, and breakdown voltage decreases seriously by the short channel effects derived from scaled down device in the case of DGMOSFET. The two dimensional analytical potential distribution derived from Poisson's equation have been used to analyze the breakdown voltage for device parameters such as channel length, channel thickness, gate oxide thickness and channel doping concentration. Resultly, we could observe the breakdown voltage has greatly influenced on device dimensional parameters as well as channel doping concentration, especially the shape of Gaussian function used as channel doping concentration.