• 제목/요약/키워드: Concentration device

검색결과 971건 처리시간 0.027초

Synthesis of Flake Type Micro Hollow Silica Using Mg(OH)2 Inorganic Template

  • Lee, Ji-Seon;Noh, Kyeong-Jae;Moon, Seong-Cheol;Lee, Young-Chul;Lee, Seong-Eui
    • 한국세라믹학회지
    • /
    • 제54권3호
    • /
    • pp.222-227
    • /
    • 2017
  • Flake-type micro hollow silica was synthesized by precipitation method using an $Mg(OH)_2$ inorganic template and sodium silicate and ammonium sulfate as the silica precursors. We investigated the effects of the silica precursor concentration on the shape, shell thickness, and surface of the hollow silica. When the concentration of the silica precursor was 0.5 M, the hollow silica had a smooth and translucent thin shell, but the shell was broken. On the other hand, the shell thickness of the hollow silica changed in the range of 12 nm to 18 nm with the increase of the precursor concentration from 0.7 M to 1.1 M. Simultaneously, unintended spherical silica satellites were created on the shell surface. The number of satellites and the size rose according to the increased concentration of silica precursor. The reason for the formation of spherical silica satellites is that the $NH_4OH$ nucleus generated in the synthesis of hollow silica acted as another silica reaction site.

C545T가 첨가된 OLED 소자의 발광특성 (The Luminescent Characteristics of C545T Doped OLED Devices)

  • 주성후;양재웅
    • 한국표면공학회지
    • /
    • 제40권2호
    • /
    • pp.77-81
    • /
    • 2007
  • To investigate the characteristics of green light-emitting OLED device, C545T material with $Alq_3$ was doped in the OLED device of $ITO(1500)/2-TNATA(400{\AA})/NPB(80{\AA})/Alq_3:C545T(160{\AA})/Alq_3(240{\AA})/LiF(3{\AA})/Al(2400{\AA})$ structure, which was used as a activator at the respective concentration of 0.5 vol.%, 1 vol.%, 2 vol.% and 3 vol.%. It was observed from the experiments that the device efficiency firstly increased with the increase of C545T concentration and the maximum efficiency of 10.9 cd/A and 4.28 lm/W was obtained at C545T concentration of 1 vol.%, and then the device efficiency decreased as the C545T activator concentration increased above 2 vol.% contents, while the longest lifetime of over 750 hours was obtained at C545T concentration of 1 vol.%.

자동차 에틸렌글리콜 부동액의 혼합 농도 측정 장치 개발 (Device Development of Mixture Concentration of Ethylene Glycol Antifreeze Coolant for Vehicles)

  • 이대웅;이은웅
    • 설비공학논문집
    • /
    • 제28권8호
    • /
    • pp.331-336
    • /
    • 2016
  • This study presents a coolant density calculation device and its corresponding method by using a mass flowmeter and the LabVIEW program. The method can be easily measured with a mixture of coolant and by calculating the percentage of ethylene-glycol without additional investment. The cooling water is very important in a vehicle to protect the engine, and the cooling performance is affected by the mixture concentration and coolant density. The coolant density calculation device measures the mixed concentration in the anti-freeze cooling mixture made from distilled water and ethylene-glycol in real time with the mass flowmeter that is commonly attached to the radiator or heater core. The calculation program for the mixture concentration percentage was developed using the LabVIEW software. The correlation between experimental results and the calculation was conducted for a range of temperature from 40 to $90^{\circ}C$ and by varying the mixture ratio of distilled water and ethylene-glycol. As a result, the anti-freeze coolant concentration in the volume percentage is able to monitor the coolant density in a timely basis by implementing a mixture concentration calculation program without the need for additional equipment investment. The results of the calculation for the mixture concentration level show a maximum 2.7% deviation compared to the experimental results.

열선을 이용한 혼합기체의 농도와 유량의 측정 (Measurement of Gas Concentration and flow Rate Using Hot Wire)

  • 김영한;최종정
    • 제어로봇시스템학회논문지
    • /
    • 제8권5호
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

Reduction of Particulate Matters Levels in Railway Cabins in Korea

  • Park, Duck-Shin;Kwon, Soon-Bark;Cho, Young-Min;Park, Eun-Young;Jeong, Woo-Tae;Lee, Ki-Young
    • 한국환경보건학회지
    • /
    • 제38권1호
    • /
    • pp.51-56
    • /
    • 2012
  • Objectives: High concentrations of airborne particulate matters (PM) can affect the health of passengers using public transportation. The objectives of this research were to develop a PM control system for a railway cabin and to evaluate the performance of the device under conditions of an actual journey. Methods: This study measured the concentrations of $PM_{10}$ and $PM_{2.5}$ simultaneously in a reference cabin and a cabin with the PM control device. Results: The average $PM_{10}$ concentration in the reference cabin was 100 ${\mu}g/m^3$, and the $PM_{10}$ concentration in the cabin with the control device was 79 ${\mu}g/m^3$. While the overall control efficiency of the control device was 15.4%, reduction was more effective for peak $PM_{10}$ concentration. However, $PM_{2.5}$ levels did not differ greatly between the reference cabin and the cabin with the control device. The ratio of $PM_{2.5}$ to $PM_{10}$ was 0.37. $PM_{10}$ concentrations in cabins were not associated with ambient concentrations, indicating that the main sources of $PM_{10}$ were present in cabins. Additionally, average $CO_2$ concentration in the cabins was 1,359 ppm, less than the maximum of 2,000 ppm set out by the Korean Ministry of Environment's guideline. The $CO_2$ concentration in cabins was significantly associated with the number of passengers: the in-cabin concentration = $23.4{\times}N+460.2$, where N is the number of passengers. Conclusions: Application of the PM control device can improve $PM_{10}$ concentration, especially at peak levels but not $PM_{2.5}$ concentration.

CODE MOSFET 소자의 제작 및 특성 (The Fabrication and Characterization of CODE MOSFET)

  • 송재혁;김기홍;박영준;민홍식
    • 대한전자공학회논문지
    • /
    • 제27권6호
    • /
    • pp.895-900
    • /
    • 1990
  • With the MOS device scailing down, the substrate concentration must increase in order to avoid punchthrough leakage current due to the DIBL(Drain Induced Barrier Lowering) effect. However the enhancement of the substrate concentration increases source, drain juntion capacitances and substrate current due to hot elelctron, degrading the speed characteristics and reliability of the MOS devices. In this paper, a new device, called CODE(Channel Only Dopant Enhancement) MOS, an its fabrication are proposed. By comparing the fabricated CODE MOSFET with the conventional device, the improvements on DIBL, substrate current and source, drain juntion capacitances are realized.

  • PDF

The development of a portable MO4- (M = 188Re or 99mTc) concentration device for extending the lifetime of RI generators

  • Choi, Kang-Hyuk;Park, Ul Jae;Kim, Jong Bum;Jang, Beom-Su
    • 대한방사성의약품학회지
    • /
    • 제5권1호
    • /
    • pp.3-10
    • /
    • 2019
  • The activities per volume of $^{188}Re$ and $^{99m}Tc$ from their generators are dependent on the specific activity of their mother nuclides $^{188}W$ and $^{99}Mo$ respectively. After a particular lapse of time, the eluted RI activity is exponentially reduced and thus cannot satisfy the needs of clinical application. The purpose of this study is to develop a $^{188}Re$ and $^{99m}Tc$ concentration device with a compact size that can extend the period of use as well as conveniently concentrate the RI. We designed the concentration module by including two-different check valves that do not required any manual on-off operations. In these concentration process, cation exchange resin embedded with Ag and anion exchange resins were used. After completing the concentrating step, the recovering yield was identified to be more than 93% for $^{188}Re$ generators and 88% for $^{99m}Tc$ generators. Moreover, all these procedures were done within 5 min.

염색물의 Color에 따른 Real Industry Color(RIC) Device와 측색기의 비교분석 및 평가 (Comparison and Evaluation of Real Industry Color(RIC) Device and Spectrophotometer for the Colors of Dyed Fabrics)

  • 빈소영;황혜진;김동권;박윤철;박순영;장은혜;배진석
    • 한국염색가공학회지
    • /
    • 제26권1호
    • /
    • pp.39-44
    • /
    • 2014
  • To confirm the performance and benefit of the developed online E-commerce Real Industrial Color(RIC) device, cotton and polyester were dyed with selected 39 colors. The captured images of dyed cotton and polyester by using RIC device were compared with original samples and confirmed ${\Delta}E$ using a spectrophotometer and RIC device. Overall, visual comparison of the captured images was similar to the real dyed samples. In high concentration of dyeings, the color consistency between real samples and captured images was better than in lower color concentration of dyeings. Similarly, the result was almost the same when the developed RIC device was used since ${\Delta}E$ values of RIC device were smaller compared with spectrophotometer. In this regards, the RIC device developed up to date can be assumed that it is more influenced by the color rather than fabric materials.

SrS:Ce EL소자에 있어서 발광중심이 휘도에 미치는 영향에 관한 연구 (A study on the influence of luminecent center on luminance in SrS:Ce electroluminescent devices)

  • Lee, Sang-tae
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 추계종합학술대회
    • /
    • pp.613-616
    • /
    • 2001
  • 공 부활제로 KCI, Cl, S 및 P를 각각 첨가한 발광충을 전자 빔 방법에 의해 성장시킨 2중 절연구조의 SrS:Ce electroluminescent(EL) device를 제작하여, 공 부활제가 EL device의 휘도에 미치는 영향을 조사였다. 휘도 및 발광파장은 첨가되는 공 부활제 및 농도에 의하여 상당한 영향을 받고 있음을 알았다. 어느 공 부활제에서나 전체 휘도는 0.2 mol%에서 최고를 나타냈으며, CeCl$_3$+KCL를 첨가한 소자가 최고 850cd/$m^2$를 나타내었다. 또한 CeP를 첨가한 소자의 경우 전체 휘도는 낮았으나 청색 휘도의 비율은 가장 높았으며, 이 비율은 농도의 상승에 따라 증가했다.

  • PDF

이차원 전위분포모델을 이용한 이중게이트 MOSFET의 항복전압 분석 (Analysis of Breakdown Voltages of Double Gate MOSFET Using 2D Potential Model)

  • 정학기
    • 한국정보통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.1196-1202
    • /
    • 2013
  • 본 연구에서는 이중게이트 MOSFET에 대한 항복전압의 변화를 채널도핑 및 소자파라미터에 따라 이차원 전위분포모델을 이용하여 분석한 것이다. 낮은 항복전압은 전력소자동작에 저해가 되고 있으며 소자의 크기가 감소하면서 발생하는 단채널 효과에 의하여 이중게이트 MOSFET의 경우도 심각하게 항복전압이 감소하고 있다. 항복전압분석을 위하여 포아송방정식의 이차원 해석학적 전위분포모델을 이용하여 채널도핑농도와 소자 파라미터인 채널길이, 채널두께, 게이트산화막 두께 등에 대하여 항복전압의 변화를 관찰하였다. 분석결과 항복전압은 채널도핑 농도의 크기뿐만이 아니라 소자크기 파라미터에 대해서 커다란 변화를 보이고 있었으며 특히 채널도핑함수인 가우시안 함수의 형태에 따라서도 큰 변화를 보이고 있다는 것을 관찰할 수 있었다.