• 제목/요약/키워드: Concentration Map

검색결과 280건 처리시간 0.03초

Study on the Development and Functional Characteristics of Salted Egg with Liquid Smoke

  • Putri Widyanti Harlina;Tri Yuliana;Fetriyuna;Raheel Shahzad;Meihu Ma
    • 한국축산식품학회지
    • /
    • 제43권3호
    • /
    • pp.471-490
    • /
    • 2023
  • In this study, the duck eggs were salted with none or 2.5% and 5.0% (v/v) of liquid smoke (LS), respectively. As a control, samples salted without LS were used. The 2-thiobarbituric acid (TBA) values, 1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging ability, and reducing power of the three groups were tested at 0, 7, 14, and 21 and 28 days to determine the effects of LS on the antioxidant activity of treated eggs. In addition, gas chromatography-mass spectrometry (GC-MS) and electronic nose (E-Nose) were used to analyze the volatile flavor components of fresh duck eggs, LS, control, and salted duck eggs enriched with 2.5% (v/v) LS after 28 days of salting. The TBA value considerably increased with an increase in salting period, and the treated egg's TBA value significantly associated with LS concentration. The TBA value decreased as the LS concentration increased. The amount of LS present was highly associated with their capacity to scavenge DPPH radicals. The reducing power of the samples was substantially correlated with the LS concentration, and the reducing power increased with increasing LS concentration. The GC-MS data revealed that phenols and ketones were the predominant chemicals present in the LS, and they were also found in the eggs added to the LS even though they were absent in the fresh eggs and control. The flavor of the control group and treated eggs with LS differed significantly, according to the principal component analysis and radar map of the E-nose. The texture study results revealed that the LS significantly impacted the hardness, cohesiveness, and chewiness of eggs.

고등어 필렛의 품질유지에 미치는 변형기체포장의 효과 (Effect of Modified Atmosphere Packaging on Quality Preservation of Mackerel Fillets)

  • 박어진;김수찬;안덕순
    • 한국포장학회지
    • /
    • 제30권2호
    • /
    • pp.131-139
    • /
    • 2024
  • MAP(변형기체포장)가 고등어 필렛의 품질유지에 미치는 효과를 5℃에서 10일 동안 저장하면서 확인하였다. 포장내 CO2 농도가 높은 CO2(60):O2(30):N2(10), CO2(60):O2(5):N2(35), CO2(60):O2(0):N2(40)의 MA 조건에 포장된 고등어 필렛에서 총 호기성균 증식 억제 효과가 있었다. 포장내 CO2 농도가 높으면서 O2를 함유하고 있는 CO2(60):O2(30):N2(10)와 CO2(60):O2(5):N2(35)의 MA 조건에서 총 휘발성 염기질소 함량이 낮았다. 지질의 산패도를 나타내는 POV와 TBARS 함량은 포장 내 O2 함량이 높은 CO2(60):O2(30):N2(10)의 MA 조건에서 높은 수치를 보였으며, 이때 고등어의 외관적 색변화도 빨라지는 것으로 확인되었다. 종합적으로 검토해 본 결과, CO2(60):O2(5):N2(35)과 CO2(60):O2(0):N2(40)의 MAP 조건이 고등어 필렛의 품질유지에 효과가 있는 것으로 보인다.

위성영상과 음영기복도를 이용한 오대산 지역 진앙의 위치와 선구조선의 관계 분석 (The Relationship Analysis between the Epicenter and Lineaments in the Odaesan Area using Satellite Images and Shaded Relief Maps)

  • 차성은;지광훈;조현우;김은지;이우균
    • 한국지리정보학회지
    • /
    • 제19권3호
    • /
    • pp.61-74
    • /
    • 2016
  • 본 연구에서는 LANDSAT 8호, KOMPSAT 2호 위성영상과 1/25,000 수치지형도를 기반으로 작성된 음영기복도를 이용하여 2007년 1월 20일 오대산 지역에서 발생한 약 4.8의 중규모 지진과 선구조선의 관계를 분석하였다. 대부분의 선행연구는 지체구조와 관련된 선구조선 분석 연구를 하였으며, 주로 2차원의 위성영상과 음영기복도를 활용하였기에 지형의 기복 등에 대한 판독이 어려워 선구조선 추출이 제한적이었다. 본 연구에서는 이를 보완하기 위해 수치표고모델(Digital Elevation Model; DEM)을 기반으로 작성한 3차원 입체 영상과 수계망 분석을 통해 지형의 기복, 수계의 연결성 등을 판독해 선구조선을 추출하여, 2차원 영상에서 나타나는 시각적인 판독에 의한 오류를 최소화한 선구조선 판독도를 작성하였다. 또한 진앙에 대한 선구조선의 통계 요소별 밀도를 추정하기 위해 spline 내삽법을 이용하여 선구조선의 빈도, 교차점, 길이에 대한 밀도를 계산하였다. 그리고 진앙에서의 선구조선 밀도가 얼마나 밀집되어 있는지 정량적으로 표현하기 위하여 각 격자 내의 선구조선 밀도에 대해 최대 선구조선 밀도로 나누는 상대밀도 값(Value of the Relative Density; VRD)을 계산하는 알고리즘을 개발하여 밀도도(density map)를 작성하였다. 각 영상의 진앙에서의 VRD는 최소 약 0.60에서 최대 약 0.90으로 나타났지만, 각 영상별 광원의 고도각과 방위각이 차이가 있어 영상별 VRD보다 통계 요소별 VRD의 평균치를 사용하였다. 그 결과, 빈도의 평균 VRD는 약 0.85로 교차점과 길이의 평균 VRD보다 약 21% 높게 나타나, 선구조선의 빈도 요소가 진앙의 위치와의 관계가 가장 밀접함을 확인하였다. 이와 같이 3차원 영상의 선구조선 추출을 통한 밀도 분석 기술은 향후 지진 발생 가능 지역 분석에 기초자료로써의 의미가 있을 것으로 기대된다.

Doping-Concentration and Annealing Effects on Photoluminescence Profile of Eu(III)-doped CeO2 nanorods

  • Lee, Juheon;Park, Yohan;Joo, Sang Woo;Sohn, Youngku
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권11호
    • /
    • pp.3319-3325
    • /
    • 2014
  • Eu(III)-doped $CeO_2$ nanorods were prepared by a co-precipitation method at room temperature, and their photoluminescence profiles were examined with different Eu(III)-doping concentrations and thermal annealing temperatures. Scanning electron microscopy, X-ray diffraction crystallography and UV-Vis absorption spectroscopy were employed to examine the morphology, crystal structure and photon absorption profiles of the nanorods, respectively. Additionally, their 2D and 3D-photoluminescence profile maps were obtained to fully understand the photoluminescence mechanism. We found that the magnetic dipole $^5D_0{\rightarrow}^7F_1$ and the electric dipole $^5D_0{\rightarrow}^7F_2$ transitions of Eu(III) were highly dependent on the doping concentration, annealing temperature and excitation wavelength, which was explained by the presence of different Eu(III)-doping sites (with and without an inversion center) in the $CeO_2$ host with a cubic crystal structure.

A Study on Runoff Characteristics of Combined Sewer Overflow(CSO) in Urban Area Using GIS & SWMM

  • Kim, Jae-Hoon;Paik, Do-Hyeon
    • 한국환경보건학회지
    • /
    • 제31권6호
    • /
    • pp.467-474
    • /
    • 2005
  • The runoff characteristics of combined sewer overflow(CSO) in the urban area of Jeonju were investigated and analyzed by using the SWMM (Storm Water Management Model) and GIS. From August to November 2004, investigations on two rainfall events were performed and flowrate, pH, BOD, COD, SS, T-N and T-P were measured. these data were used for model calibration. Using GIS technique, watershed characteristics of study area were calculated. that is, divide into sub_basin, total width, slope, make soil map etc. On the basis of the measured data and the simulation results by SWMM, it could be known that the $80-90\%$ of pollution load are discharged in early-stage storm runoff. SMC(site mean Concentration) for combined sewer system area were BOD 28.1, COD 31.5, SS 186 ppm etc. this is shown that during the rain fall, high concentration of waste was loaded to receiving water. Unit loads of combined sewer system area were BOD 306, COD 410, SS 789, T-N 79, T-P 6.8 kg/ha/yr.

Comparison of Four Different Ordination Methods for Patterning Water Quality of Agricultural Reservoirs

  • Bae, Mi-Jung;Kwon, Yong-Su;Hwang, Soon-Jin;Park, Young-Seuk
    • 생태와환경
    • /
    • 제41권spc호
    • /
    • pp.1-10
    • /
    • 2008
  • We patterned water quality of agricultural reservoirs according to the differences of six physico-chemical environmental factors (TN, TP, DO, BOD, COD, and SS) using four different ordination methods: Principal Components Analysis (PCA), Detrended Correspondence Analysis (DCA), Nonmetric Multidimensional Scaling (NMS), and Isometric Feature Mapping (Isomap). The data set was obtained from the water quality monitoring networks operated by the Ministry of Agriculture and Forestry and the Ministry of Environments. Chlorophyll-${\alpha}$ displayed the highest correlation with COD, followed by TP, BOD, SS, and TN (p<0.01), while negatively correlated with altitude and bank height of the reservoirs (p<0.01). Although four different ordination methods similarly patterned the reservoirs according to the gradient of nutrient concentration, PCA and NMS appeared to be the most efficient methods to pattern water quality of reservoirs based on the explanation power. Considering variable scores in the ordination map, the concentration of nutrients was positively correlated with Chl-${\alpha}$, while negatively correlated with altitude and bank height. These ordination methods may help to pattern agricultural reservoirs according to their water quality characteristics.

전력선통신 기반 저압원격검침 시스템의 공간 정보를 활용한 지능형 배전망 지리정보시스템 구축에 관한 연구 (A Study on the Implementation of Geographic Information System for an Intelligent Power Distribution Network with Location Informations of Power Line Communication-based Automatic Meter Reading System)

  • 서충기;이승걸
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.365-369
    • /
    • 2015
  • In this paper, geographic information system(GIS) for an intelligent power distribution network was implemented with location informations acquired from automatic meter reading system, where the location informations of power line communication(PLC) modems installed at customer side were collected at data concentration units(DCUs) of headend equipment via PLC and then were transmitted to front end processor server. By displaying the connection status of the power distribution network on GIS map, operation of advanced metering infrastructure(AMI) or management of power grid system could be performed intuitionally and in real time, because the configuration state of the power grid could be easily monitored. The feasibility of the proposed system was confirmed with the especially constructed laboratory-level test bed and the verification test of the system will be carried out for a real power distribution network.

서울지역 지하철역의 라돈농도 분포 특성 (Distribution of $^{222}Rn$ Concentration in Seoul Subway Stations)

  • 전재식;김덕찬
    • 대한환경공학회지
    • /
    • 제28권6호
    • /
    • pp.588-595
    • /
    • 2006
  • 본 연구는 서울지역 지하철역 실내 공기 중 라돈분포를 조사하여 그 발생원을 추적 확인하기 위하여 수행되었다. 1998년부터 2004년까지 232개 역사를 대상으로 알파비적검출기를 사용하여 실내 공기 중 장기라돈을 측정하였으며 지하수중 라돈농도는 알파입자계수법에 의하여 측정하였다. 라돈의 주 발생원을 추적하기 위하여 8개 역사를 선정하여 각 역사의 승강장과 인접터널에 대한 공기 중 라돈농도를 조사하였다. 전체역사에 대한 라돈농도 분석결과 기하평균 및 산술평균은 각각 $1.40{\pm}1.94pCi/L,\;1.65{\pm}1.07$였으며, 승강장과 매표소의 기하평균은 각각 $1.54{\pm}1.96pCi/L,\;1.23{\pm}1.88pCi/L$로 승강장에서의 라돈농도가 매표소의 농도보다 더 높게 나타났다. 지질구조와 지하역사의 라돈분포는 밀접한 상관성을 보였으며 터널내부와 지하수중의 라돈농도는 역사 승강장의 라돈농도에 크게 영향을 미치고 있었다. 또한 역사의 승강장이 위치하고 있는 깊이 정도에 따라 라돈농도의 차이를 보였다(p<0.05).

Gallic acid가 Lipopolysaccharide로 활성화된 마우스 대식세포의 인터루킨 생성에 미치는 영향 (Inhibitory Effect of Gallic acid on Production of Interleukins in Mouse Macrophage Stimulated by Lipopolysaccharide)

  • 박완수
    • 대한약침학회지
    • /
    • 제13권3호
    • /
    • pp.63-71
    • /
    • 2010
  • Objectives: Gallic acid (GA) is the major component of tannin which could be easily founded in various natural materials such as green tea, red tea, grape juice, and Corni Fructus. The purpose of this study is to investigate the effect of Gallic acid (GA) on production of interleukin (IL) in mouse macrophage Raw 264.7 cells stimulated by lipopolysaccharide (LPS). Methods: Productions of interleukins were measured by High-throughput Multiplex Bead based Assay with Bio-plex Suspension Array System based on $xMAP^{(R)}$ (multi-analyte profiling beads) technology. Firstly, cell culture supernatant was obtained after treatment with LPS and GA for 24 hour. Then, it was incubated with the antibody-conjugated beads for 30 minutes. And detection antibody was added and incubated for 30 minutes. And Strepavidin-conjugated Phycoerythrin (SAPE) was added. After incubation for 30 minutes, the level of SAPE fluorescence was analyzed on Bio-plex Suspension Array System and concentration of interleukin was determined. Results: The results of the experiment are as follows. 1. GA significantly inhibited the production of IL-3, IL-10, IL-12p40, and IL-17 in LPS-induced mouse macrophage RAW 264.7 cells at the concentration of 25, 50, 100, 200 uM (p<0.05). 2. GA significantly inhibited the production of IL-6 in LPS-induced mouse macrophage RAW 264.7 cells at the concentration of 50, 100, 200 uM (p<0.05). 3. GA diminished the production of some cytokine such as IL-4, IL-5, and IL-13 in LPS-induced mouse macrophage RAW 264.7 cells. 4. GA did not show the inhibitory effect on the production of IL-$1{\alpha}$ and IL-9 in LPS-induced mouse macrophage RAW 264.7 cells. Conclusions: These results suggest that GA has anti-inflammatory activity related with its inhibitory effects on the production of interleukins such as IL-3, IL-10, IL-12p40, IL-17, and IL-6 in LPS-induced macrophages.

지리정보시스템(GIS)을 이용한 토양지질도 분포와 실내라돈 상관성 연구 : 화천 및 장수의 사례를 근거로 (The Research for Relationships between Concentration of Indoor Radon and Distribution of Soil Geological Map using GIS : Based on the Hwacheon and Jangsu Areas)

  • 권명희;이재원;김성미;이정섭;정준식;유주희;이규선;송석환
    • 한국산업보건학회지
    • /
    • 제27권4호
    • /
    • pp.333-351
    • /
    • 2017
  • Objectives: This study examines the relationships between indoor radon concentrations and distribution from soil geological mapping in the Hwacheon and Jangsu areas. Methods: GIS and a pivot table were used for inquiries about indoor radon contents, soil characteristics, and geological differences. Results: The Hwacheon area was characterized by the presence of normal and reverse faults as a passage of runoff for radon, sufficient occurrences of minerals containing uranium within granite as a radon source, a high concentration of radon within the granite area and clear differences of radon concentrations between granitic and metamorphic areas. The Jangsu area was characterized by the presence of normal faults, wide distributions of alluvium, and ambiguities on radon concentrations indoors among areas of geological differences. Considering the granite area and alluvium surrounded with granite areas, the characteristics of radon concentrations within soils and indoors in the Jangsu area are similar to those of the Hwacheon area. High concentrations are found with entisol and inceptisol in the Hawcheon area, but with entisol, inceptisol, and ultisol in the Jangsu area. High radon concentrations are found in sandy loam and/or loam. High concentrations are found in recently constructed or brick buildings, but low concentrations in traditional or prefabricated houses showing a high possibility of outward flow. Conclusions: The overall results suggest that radon concentrations in the Hwacheon and Jangsu area are dominantly influenced by geological characteristics with additional artificial influences.