• Title/Summary/Keyword: Concentration Estimation

Search Result 944, Processing Time 0.031 seconds

제설제 살포에 따른 콘크리트 포장의 염화물 침투특성 (Characteristics of Chloride Penetration due to Sprinkle of the Deicing Salt on the Concrete Pavement)

  • 박진호;김명유;양은익;이성태;박해균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.475-478
    • /
    • 2005
  • Deicing salt has been generally used for traffic safety in winter, and the amount is increasing every year. However, deicing salt may induce the decrease of bond strength, surface scaling, and environmental pollution, etc. the purpose of this paper is to suggest the fundamental data on safety and durability for concrete structures through the estimation of chloride concentration profile and chloride diffusion coefficient. According to the test results, the critical chloride concentration($0.9\~1.2kg/m^3$)was measured at depth $23\~30mm$, and the limit chloride concentration($0.3kg/m^3$)was reached to depth 40mm. Also the surface chloride amount indicates 3.45kg per concrete unit weight, and the results showed the possibility of corrosion by deicing salt penetration.

  • PDF

탄소나노튜브/에폭시 복합소재의 감쇠특성 분석 (Damping Characterization of Carbon Nanotube/Epoxy Composites)

  • 신응수;이종화
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.497-502
    • /
    • 2003
  • This study intends to provide the analytical and experimental damping characterization of carbon nanotube/epoxy composites. A constitutive model based on continuum mechanics is employed to describe epoxy and the perfectly bonded and partially bonded nanotubes. An interfacial stick-slip between the nanotubes and epoxy is considered to characterize the damping of the composites. For experimental estimation, beam-type specimens are prepared with a variation of nanotube concentration from 0.5% to 2% in weight. An ultrasonic agitation method is employed for enhancing the nanotube dispersion within epoxy. Damping of the composites is characterized in terms of the strain and the nanotube concentration. Results show that the nanotube concentration significantly affects the damping characteristics of the nanocomposites. A good correlation is found between the analytical prediction based on the stick-slip and the experimental measurements.

  • PDF

농지-임야 유역의 비점원 발생 BOD 부하의 추정 (Estimation of BOD Loading of Diffuse Pollution from Agricultural-Forestry Watersheds)

  • 김건하;권세혁
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.617-623
    • /
    • 2005
  • Forestry and agricultural land uses constitute 85% of Korea and these land uses are typically mixed in many watersheds. Biological Oxygen Demand (BOD) concentration is a primary factor for managing water qualities of the water resources in Korea. BOD loadings from diffuse sources, however, not well monitored yet. This study aims to assess BOD loadings from diffuse sources and their affecting factors to conserve quality of water resources. Event Mean Concentration (EMC) of BOD was calculated based on the monitoring data of forty rainfall events at four agricultural-forestry watersheds. Exceedence cumulative probability of BOD EMCs were plotted to show agricultural activities in a watershed impacts on the magnitude of EMCs. Prediction equation for each rainfall event was proposed to estimate BOD EMCs: $EMC_{BOD}(mg/L)=EXP(0.413+0.0000001157{\times}$(discharged runoff volume in $m^3$)+0.018${\times}$(ratio of agricultural land use to total watershed area).

Estimation of Cell Concentration by Light Transmitter During the Culture of Methylotrophic Yeast Pichia pastoris

  • Choi, Du-Bok;Park, Enoch Y.S.;Lee, Yong-Bo;Na, Young-Hee;Lim, Chae-Kyu
    • Mycobiology
    • /
    • 제31권4호
    • /
    • pp.226-228
    • /
    • 2003
  • The multiple correlation coefficient between the values determined by dry weight and those determined by fluorometer was observed with r=0.96 and the standard error of calibration was 0.034. Using the best calibration data, in order to reconfirm the reliability of the fluorometer results in comparison with those obtained by dry weight on the cell concentration, fedbatch cultures were carried out. The results obtained by fluorometer measurements were in good agreement with those obtained by dry weight. The on-line monitoring of cell concentration by the fermentor system linked to a computer equipped with fluorometer was successfully carried out.

석면방직업 근로자의 석면노출 실태와 과거농도 추정에 관한 연구 (A Study on Exposure Among Asbestos Textile Workers and Estimation of their Historical Exposures)

  • 박정임;윤충식;백남원
    • 한국산업보건학회지
    • /
    • 제5권1호
    • /
    • pp.16-39
    • /
    • 1995
  • From July 8 to September 2 1994, asbestos exposure level among asbestos textile workers was surveyed. Six plants out of plants in Korea were selected for this study. In addition to the exposure level, the relationship between the level of exposure and some factors affecting exposure were studied. Also, using historical data of asbestos concentrations in asbestos textile plants plus current data, trend of asbestos exposure level could be introduced. Historical exposure level was estimated on the basis of these data. The main results of this study are follows. 1. Average concentration of all six plants surveyed was 1.54 f/cc, and range of those concentrations was 0.03 - 11.58 f/cc. The minimum average concentration was 0.32 f/cc and the maximum was 8.04 f/cc which is four times higher than the Korean standard. A wide difference of exposure level among the workers of different plants was observed. In three plants, the half of all the plants surveyed, their average concentrations exceeded the Korean standard, and those in all the plants exceeded the ACGIH TLV. 2. Among total 56 samples, 22 samples(39%) were in excess of the Korean standard, and 53 samples(95%) were above the ACGIH TLV. Among 32 personal samples, 15 samples(47%) exceeded the Korean standard, and 30 samples(94%) exceeded the ACGIH TLV. Among 24 area samples excluding a few samples collected in office area, seven samples exceeded the Korean standard, and 23 samples( 96%) exceeded the ACGIH TLV. 3. Distributions of concentrations were observed by processes. In weaving, the highest, average concentration was 4.29 f/cc, and range was 2.61 - 11.58 f/cc. In spinning, average concentration was 2.22 f/cc, and range was 0.41 - 8.93 f/cc. In carding, average concentration was 1.98 f/cc, and range was 0.23 - 10.93 f/cc, In twisting, average concentration was 1.65 f/cc, and range was 0.21 - 9.83 f/cc. In mixing, the lowest, average concentration was 0.48 f/cc, and range was 0.22 - 1.20 f/cc. 4. All the samples from basic processes of asbestos textile plants were above the ACGIH TLV. Nineteen samples(45%) out of all these 42 samples exceeded Korean standard. Fourteen samples(58%) of total 24 personal samples, and five samples(28%) of total 18 area samples exceeded the Korean standard. Considering processes, all the samples in weaving process exceeded the Korean standard and 50 did 54% of those in spinning, 40% in carding, and 27% in twisting. 5. Trend of decreasing asbestos concentrations in asbestos textile plants was observed by time. 6. Asbestos concentrations in asbestos textile plant in 1975 were estimated to be 11.0 - 92.4 f/cc.

  • PDF

대기 중 수은의 습식 침적 평가: 소양호를 중심으로 (Estimation of Atmospheric Mercury Wet-deposition to Lake So-yang)

  • 안명찬;한영지
    • 한국대기환경학회지
    • /
    • 제24권6호
    • /
    • pp.693-703
    • /
    • 2008
  • The important source of the mercury in water-column is the influx of atmosphere mercury, via dry and wet deposition. In this study, wet deposition of mercury was estimated to be $14.56{\mu}g/m^2$ during 15 months at the Lake Soyang, which is a little higher than those observed in the several rural US Mercury Deposition Network (MDN) sites with similar precipitation depth. The mercury concentration in precipitation did not show a positive correlation with atmospheric RGM (reactive gaseous mercury) concentration, while maintaining good correlation with atmospheric $PM_{2.5}$ at Soyang Dam. This result suggests that the contribution of particulate Hg to the total Hg wet deposition should be more significant than that of RGM. In this study, both precipitation depth and precipitation type affected the amount of wet deposition and the concurrent mercury levels in precipitation. There was generally an inverse relationship between precipitation depth and Hg concentration in precipitation. Precipitation type was another factor that exerted controls on the Hg concentration in precipitation. As a result, the highest concentration of Hg was observed in snow, followed by in mixture (snow+rain) and in rain.

고농도 암모니아성 질소 폐수의 효과적인 혐기성 처리를 위한 영향 인자 평가 (Estimation of influening factors for efficient anaerobic digestion of high strength ammonia-nitrogen wastewater)

  • 박세용;박정훈;나효성;김문일
    • 상하수도학회지
    • /
    • 제26권5호
    • /
    • pp.649-658
    • /
    • 2012
  • In this study, the influencing factors for efficient anaerobic digestion of high strength ammonia-nitrogen wastewater removal were investigated by testing biochemical methane potential test. In the influencing factors, the trace metals which could increase activity of anaerobic microorganisms, microbial concentration and types were evaluated. In the results, trace metals supplementation showed gas production amount higher than those without addition of trace metals. Among the tested trace metals, B, Ni, and Se were preferable to gas production. In the result of gas production according to the microbial concentration, the amount of gas production was proportional to the microbial concentration. In addition, the shortest lag time and the fastest gas production rate were achieved when the highest microbial concentration was tested. granule-type microorganism produced more gas than suspended-type microorganism. In conclusion, the efficient anaerobic digestion for high strength ammonia-nitrogen wastewater removal could be achieved by applying necessary trace metals injection and high concentration granule type microorganism.

Assessment of N-16 activity concentration in Bangladesh Atomic Energy Commission TRIGA Research Reactor

  • Ajijul Hoq, M.;Malek Soner, M.A.;Salam, M.A.;Khanom, Salma;Fahad, S.M.
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.165-169
    • /
    • 2018
  • An assessment for determining N-16 activity concentrations during the operation condition of Bangladesh Atomic Energy Commission TRIGA Research Reactor was performed employing several governing equations. The radionuclide N-16 is a high energy (6.13 MeV) gamma emitter which is predominately created by the fast neutron interaction with O-16 present in the reactor core water. During reactor operation at different power level, the concentration of N-16 at the reactor bay region may increase causing radiation risk to the reactor operating personnel or the general public. Concerning the safety of the research reactor, the present study deals with the estimation of N-16 activity concentrations in the regions of reactor core, reactor tank, and reactor bay at different reactor power levels under natural convection cooling mode. The estimated N-16 activity concentration values with 500 kW reactor power at the reactor core region was $7.40{\times}10^5Bq/cm^3$ and at the bay region was $3.39{\times}10^5Bq/cm^3$. At 3 MW reactor power with active forced convection cooling mode, the N-16 activity concentration in the decay tank exit water was also determined, and the value was $4.14{\times}10^{-1}Bq/cm^3$.

다변량 통계분석법을 이용한 대구지역 부유분진의 오염원 기여도 추정 (Estimation of Source Contribution of Particulate Matter in Taegu Area using Factor Analysis)

  • 최성우;송형도
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.1-8
    • /
    • 2000
  • The objective of this study was to identify the sources and to estimate the source contributions to the atmospheric TSP(total suspended particulate matter) and PM-10(particulate matter with aerodynamic diameters less than 10$\mu\textrm{m}$) concentration in Taegu area. A total of 84 samples was collected during the January to December 1999. TSP and PM-10 were collected on filters by portable air sampler, and heavy metals in TSP and PM-배 were analyzed by ICO(Inductively Coupled Plasma Spectrometery) after preliminary treatment. The results were follow as : First, annual average of TSP and PM-10 concentration was 123 and 69$\mu\textrm{g}$/㎥ respectively. The concentration of TSP and PM-10 were highest in winter season compared to other seasons. Second, the concentration of Al, Fe, Mn were higher in TSP than in PM-10, indicating that these heavy metals are generally associate with natural contributions. Third, metal combinations showed that a high correlation among concentrations of heavy metals were follows: As Al, Fe and Mn in TSP ; Ni, Cr, Cd and Pb in PM-10. Finally, Statistical analysis was performed using Principal Components Analysis(PCA) in order to find possible sources of the pollutants. The factor analysis was permitted to identify four major sources(soil/road dust resuspension, waste incineration, furl combustion, vehicular emission) in each fraction. These source accounted for at least 83, 85% of variance of TSP and PM-10 concentration in Taegu area.

  • PDF

장기 노출 $NO_2$ 간이 샘플러 개발에 관한 연구 (A Study on the Development of Long Term Exposure $NO_2$ Sampler)

  • 이동인;김윤선
    • 한국안전학회지
    • /
    • 제10권2호
    • /
    • pp.105-112
    • /
    • 1995
  • The concentrations of $NO_2$ were measured to estimate a new developed long term exposure $NO_2$ sampler at Pusan City considering the meteorological factors from May to July, in 1994. The monthly mean concentration of $NO_2$ was 15.9 PPb and 36.2 ${\mu}\ell$/day $NO_2$ and their high values were shown in the downtown of Pusan City which show potential pollution due to the increase of traffic activities and micrometeorological factors In and around the City. As a result of statistical correlation between $NO_2$ concentration by new sampling method and $NO_2$ concentration by the handy air sampler and chemiluminescent nitrogen oxides analyzer, 1994, correlation coefficients were high(r=0.93) and showed more than 0.88 value in the high concentration data set, which was arbitrarily divided into 30${\mu}\ell$ $NO_2$ concentration in an attempt to further investigate these relationships. Therefore, use of new developed long term exposure $NO_2$ sampler is good for $NO_2$ measurement and valuable for estimation of air quality in the urban and Industrial area.

  • PDF