• Title/Summary/Keyword: Concentration Characteristics

Search Result 9,696, Processing Time 0.038 seconds

Characteristics of Photovoltaic Power Generation by Concentration and Tracking (집광추적형 PV발전의 특성에 관한 연구)

  • Kim, B.R.;Park, S.G.;Oh, H.G.;Yu, Y.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.39-40
    • /
    • 2005
  • Photovoltaic Power Generation system occupies an important position as an alternative energy source, converting directly sunlight into electricity,using a photovoltaic cell. The Purpose of this research is to present and confirm the effectiveness of concentration and tracking of sun in photovoltaic power generation. Comparative experiments were carried outwith two rating 75 watt solar modules in $25^{\circ}$ under condition of various times concentration, tracking and plain normal measuring generated voltages, currents and temperatures of back sheet of modules by internet monitoring system to find out which is best in economic sense. The experiments show that output power of concentration and tracking photovoltaic power generation is over 180% more then that of plain normal system.

  • PDF

A Study on Dust Explosion Characteristics of Hydroxypropyl Methyl Cellulose (Hydroxypropyl Methyl Cellulose의 분진 폭발특성에 관한 연구)

  • 임우섭;목연수
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.95-100
    • /
    • 2000
  • This study was performed in Hartmann type dust explosion apparatus in order to research the dust explosion characteristics of hydroxypropyl methyl cellulose(HPMC): minimum explosive limit, minimum ignition energy, limiting oxygen concentration, maximum explosion pressure, rate of pressure rise, etc. The samples of HPMC dust were distributed into 120-140 mesh, 170-230 mesh and 325 under, and the gap distance of the discharge electrode was setted up at 5mm. The experimental results were obtained as follows: (1) The minimum explosive limit for HPMC dust was founded at 180g/㎥. the minimum ignition energy at 9.8mJ and the limiting oxygen concentration at 12%. (2) The maximum explosion pressure of HPMC dust was $8.1kg/cm^2\;{\cdot}\;$abs at the concentration of $500g/m^3$ and the maximum rate of pressure rise was 203.98 bar/sec at the concentration of $480g/m^3$ for 325 under.

  • PDF

Photovoltaic Characteristics of Low-density Concentration GaAs Solar Cells with/without Anti-reflective Coating

  • Noh, Sam Kyu;Kim, Jong Soo;Kim, Jin Soo;Yu, Jae Su
    • Applied Science and Convergence Technology
    • /
    • v.23 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • We have studied photovoltaic characteristics of single-junction GaAs solar cells with/without an $MgF_2/ZnS$ anti-reflective coating (ARC) illuminated by low-density concentration (<10 suns). By the ARC deposition, the short-circuit current density ($J_{SC}$) and the fill factor (FF) are increased by $5mA/cm^2$ and 5% at a standard illumination (1 sun), respectively, and the resulted conversion efficiency is enhanced by 45%. In contrast with the cell with no ARC showing a rapid degradation with increasing concentration power, the efficiency of ARC-deposited cell remains almost constant as ($17.7{\pm}0.3$)% regardless of the concentration. It informs that ARC treatment is very effective in GaAs concentrator solar cells.

Study on the Characteristics of Crevice Corrosion Prevention of SS 400 in Marine Environment (해양환경 중에서 SS400강재의 간극부식방지 특성에 관한 연구)

  • 임우조;정기철;구영필;윤병두
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.152-157
    • /
    • 2001
  • This paper was studied on the characteristics of crevice corrosion prevention of SS 400 in marine environment. In NaCl solution, polarization behavior under the crevice corrosion was investigated. And Weight loss rate of SS 400 applied cathodic protection and non cathodic protection was measured according to the NaCl concentration. The main results obtained are as follows : The weight loss rate of Al-alloy galvanic anode was increased as the concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5%, that of Al-alloy galvanic anode become decreased. The protective potential of SS 400 used Al-alloy galvanic anode becomes more cathodic polarization with increasing concentration of NaCl solution. Effects of oxygen on the weight loss rate of Al-alloy sacrificial anode for cathodic protection as the concentration of 3.5% NaCl solution become sensitive than that of 0% NaCl solution.

  • PDF

Effects of Alkali Concentration on Fiber Characteristics of SwBKP during Alkali Treatment in Cosolvent System (알칼리 공용매 팽윤처리 시 알칼리 농도가 SwBKP 섬유 특성에 미치는 영향)

  • Seo, Ji-Hye;Choi, Kyoung-Hwa;Cho, Byoung-Uk
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.48 no.3
    • /
    • pp.37-43
    • /
    • 2016
  • Various mechanical and chemical pretreatment methods including alkali treatment, pre-beating, enzyme treatment and oxidation treatment have been used to reduce the production energy of the microfibrillated cellulose (MFC). Among them, alkali swelling can be helpful to reduce the energy consumption because the internal bonding between fibrils could be weakened. In this study, dimethyl sulfoxide (DMSO) was used as a cosolvent to improve alkali pretreatment efficiency and the effects of NaOH concentration during NaOH-DMSO swelling on changes in fiber characteristics of softwood bleached kraft pulp (SwBKP) were elucidated. For alkali treatment in H2O-DMSO solvents, fiber length were decreased with increasing NaOH concentration while fiber width, curl and WRV were increased. WRV began to increase at 8% NaOH solution. In addition, above 8% concentration of NaOH, crystalline structure of pulp fibers converted from cellulose II to cellulose III by DMSO cosolvent. Comparing the previous results with this study, it was shown that DMSO cosolvent could promote swelling of pulp fibers and thus reduce NaOH concentration for the maximum swelling of fibers.

Combustion Characteristics of a Turbulent Non-premixed Flame Using High Preheated Air (고온 예열 공기에 의한 난류 비예혼합 화염의 연소 특성)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.561-568
    • /
    • 2003
  • An experiment using high preheated air in a turbulent non-premixed flame was performed to investigate the effects of high preheated air on the combustion characteristics. Combustion using high preheated and diluted air with flue gas is a new technology which enables NO emission to be reduced. In this study, Na was used as diluent and propane as fuel. Combustion characteristics, especially the distributions of the flame temperature, NO concentration and OH radical intensity were examined under the condition of 300 K, 600 K, 1000 K in terms of the combustion air temperature, and also under the condition of the dilution level from 21% to 13% in terms of oxygen concentration. As the preheated air temperature increased, it appeared that the flame length became shorter, maximum flame temperature increased, the reaction region moved to upstream, and NO concentration increased, but the flame temperature's fluctuation was reduced. In opposite, it was shown with decrement of oxygen concentration at the maximum temperature that both maximum value and the gradient of the flame temperature decreased, and NO emission also decreased considerably, but its fluctuation became larger, being inclined to be unstable.

A Comparison of Nutrients Removal Characteristics by the Variation of Organics in $A_{2}O$ SBR and $A_{2}O$ SBBR for the Small Sewerage System (소규모 오수처리를 위한 $A_{2}O$ SBR과 $A_{2}O$ SBBR에서 유입 유기물 농도변화에 따른 염양염류 제거 특성 비교)

  • Park, Young-Seek;Jeong, No-Sung;Kim, Dong-Seog
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.451-461
    • /
    • 2006
  • Laboratory scale experiments were conducted to study the conversion of sludge from conventional activated sludge to nitrogen-phosphorus removal sludge using two types of sequencing batch reactor (SBR) systems, a conventional SBR and sequencing batch biofilm reactor (SBBR). The nitrogen and phosphorus removal characteristics were similar between SBR and SBBR and the removal efficiencies were very low when the influent TOC concentrations were low. The nitrogen and phosphorus removal efficiencies in SBR were 96% and 77.5%, respectively, which were higher than those in SBBR (88% and 42.5%) at the high influent TOC concentration. In SBBR, the simultaneous nitrification-denitrification was occurred because of the biofilm process. The variations of pH, DO concentration and ORP were changed as the variation of influent TOC concentration both in SBR and SBBR and their periodical characteristics were cleary shown at the high influent TOC concentration. Especially, the pH, DO concentration and ORP inflections, were cleary occurred in SBR compared with SBBR.

A Study on the Characteristics of the High Concentration Ozone Generator for the Semiconductor Wafer Cleaning with the Ozone Dissolved De-ionized Water (반도체 웨이퍼의 오존 수(水) 세정을 위한 고농도 오존발생장치 특성 연구)

  • 손영수;함상용;문세호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.579-585
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DI-O3 water) in semiconductor wet cleaning process to replace the conventional RCA methods has been studied. In this paper, we propose the water-electrode type ozone generator which has the ozone gas characteristics of the high concentration and high purity to produce the high concentration DI-O3 water for the silicon wafer surface cleaning process. The ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. We investigate the performance of the proposed ozone generator which has the design goal of the concentration of 7[wt%] and ozone generation quantity of 6[g/hr] at flow rate of 1[$\ell$/min). The experiment results show that the water electrode type ozone generator has the characteristics of 8.48[wt%] of concentration, 8.08[g/hr] of generation quantity and 76.2[g/kWh] of yield and it's possible to use the proposed ozone generator for the DI-O3 water cleaning process of silicon wafer surface.

Comparison of High Concentration Prediction Performance of Particulate Matter by Deep Learning Algorithm (딥러닝 알고리즘별 미세먼지 고농도 예측 성능 비교)

  • Lee, Jong-sung;Jung, Yong-jin;Oh, Chang-heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.348-350
    • /
    • 2021
  • When predicting the concentration of fine dust using deep learning, there is a problem that the characteristics of a high concentration of 81㎍/m3 or more are not well reflected in the prediction model. In this paper, a comparison through predictive performance was conducted to confirm the results of reflecting the characteristics of fine dust in the high concentration area according to the deep learning algorithm. As a result of performance evaluation, overall, similar levels of results were shown, but the RNN model showed higher accuracy than other models at concentrations of "very bad" based on AQI. This confirmed that the RNN algorithm reflected the characteristics of the high concentration better than the DNN and LSTM algorithms.

  • PDF

Analysis of Energy Concentration Characteristics of Heliostat used in 200kW Tower Type Solar Thermal Power Plant (200kW 탑형 태양열발전시스템에서 사용되는 Heliostat의 집열특성 분석)

  • Park, Young-Chil
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.80-88
    • /
    • 2011
  • Heliostat in the tower type solar thermal power plant is a sun tracking mirror system to reflect the solar energy to the receiver and the optical performance of it affects to the efficiency of whole power plant most significantly. Thus a solid understanding of heliostat's energy concentration characteristics is the most important step in designing of the heliostat field and the whole power plant. The work presented here is the analysis of energy concentration characteristics of heliostat used in 200kW solar thermal power plant, where the receiver located at 43m high in tower has $2{\times}2$m rectangular shape. The heliostat reflective surface is formed by 4 of $1{\times}1$m flat plate mirror facet and the mirror facet is mounted on the spherical frame. The direct normal incident radiation models in vernal equinox, summer solstice, autumnal equinox and winter solstice are first derived from the actually measured data. Then the intercept ratio, heat flux distribution and total energy collected at the receiver for the heliostats located in the various places of the heliostat field are investigated. Finally the effect of mirror facet installation error on the optical performance of the heliostat is analyzed.