• 제목/요약/키워드: Concentrating Solar Energy System

Search Result 54, Processing Time 0.019 seconds

A Survey of Direct Normal Insolation Resources for the Construction of Solar Concentrating Power Generation Sites in Korea (국내 고집광 태양에너지 발전단지 건설을 위한 법선면 직달일사량 자원조사)

  • Jo, Dok-Ki;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.209-214
    • /
    • 2008
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean 2.67 kWh/$m^2$/day of the direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were 2.91 kWh/$m^2$/day and 2.23 kWh/$m^2$/day, and for fall and winter their values were 2.78 kWh/$m^2$/day and 2.77 kWh/$m^2$/day respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value

  • PDF

Design and Construction Experiences of 10kWe Dish-type Solar Thermal Power Generation System (Dish형 집광장치 이용 10kWe급 태양열 발전시스템 설계 및 시공 사례)

  • Lee, Sang-Nam;Kang, Yong-Heack;Jo, Dok-Ki;Yu, Chang-Kyun;Yoon, Hwan-Ki;Kim, Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.684-687
    • /
    • 2005
  • KIER has been running a demonstration project for 10kWe solar thermal power generation. the project is to build and operate the first solar thermal power generation system in Korea. For concentrating solar thermal energy $40m^2$ dish type concentrator was adapted and a stirling engine is going to be integrated to the system for power production. At the moment building the dish concentrator including mirror and sun tracking system was completed and it's performance are being closely evaluated. This paper will introduce some detailed designs and construction procedures which we have experienced so far.

  • PDF

An Experimental Study on the Thermal Characteristics of Hybrid Solar Receiver for Dish/Stirling System (Dish/Stirling 시스템 적용을 위한 Hybrid 태양열 흡수기의 열특성에 관한 실험 연구)

  • Kang, Myeong-Cheol;Kim, Jin-Soo;Kang, Yong-Heack;Kim, Nack-Joo;Yoo, Seong-Yeon;Kim, Jin-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.7-13
    • /
    • 2007
  • A Dish type solar concentrating system consists of a parabolic concentrator and a cavity receiver. In order to achieve high temperatures from solar energy, it is essential to efficiently reflect the solar rays in the concentrator and to minimize thermal losses in the cavity receiver. Improving the economical efficiency of a solar power system required the stirling unit to be operated continuously. For continuous operation of the stilting unit, the receiver must be continuously provided with thermal energy from solar as well as additional combustion heat. It is possible for a hybrid solar receiver system equipped with an additional combustion to be operated 24 hrs/day. A hybrid solar receiver was designed and manufactured for a total thermal load of 35 kW in the operating temperature range $700^{\circ}C$ to $800^{\circ}C$. The hybrid receiver system was tested in gas-only mode by gas-fired heat to investigate thermal characteristics at inclination angle varying from 0 deg to 30 deg(cavity facing down) and the aperture to cavity diameter ratios of 0(closed cavity) and 1.0(open cavity). This paper has been conducted to measure temperature distribution in cavity surface and to analyze thermal resistances, and the evaporation and condensation heat transfer coefficient in all cases(open and closed cavity).

Analysis of Direct Normal Insolation Resources in Korea (국내 직달일사량 자원 분석)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.130.1-130.1
    • /
    • 2011
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $2.67kWh/m^2/day$ of the all day's direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were $2.91kWh/m^2/day$ and $2.23kWh/m^2/day$, and for fall and winter their values were $2.78kWh/m^2/day$ and $2.77kWh/m^2/day$ respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value.

  • PDF

Design and Construction Experiences of Solar Thermal Chemical Reaction Hybrid Power Generation (태양열 화학반응 복합발전시스템의 설계 및 시공 사례)

  • Lee, Sang-Nam;Kang, Yong-Heack;Kim, Jin-Soo;Yoon, Hwan-Ki;Yu, Chang-Kyun;Kim, Jong-Kyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.688-692
    • /
    • 2007
  • Solar thermal power generation allows additional benefits of cheap thermal storage and easy hybridization with other fossil fuel-driven power generation. KIER has been performing the project for solar thermal chemical reaction hybrid power generation. The project is to build and operate the first solar thermal chemical reaction hybrid power generation system in Korea. For concentrating solar thermal energy $m^2$ dish type concentrator was adapted and a heliostat is installed for reflecting horizontal insolation to the dish concentrator. At the moment building the dish concentrator including mirror and heliostat with sun tracking system was completed and it's performance are being closely evaluated. This paper will introduce some detailed designs and construction procedures which we have experienced so far.

  • PDF

Design of Concentrating System for Solar Side-pumped Slab Laser

  • Fan, Wentong;Liu, Yan;Guo, Pan;Deng, Rui;Li, Nan;Ding, Fukang;Li, Yasha;Zhou, Jun;Xie, Shiwei
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.50-56
    • /
    • 2020
  • The design of a concentration system for a solar side-pumped slab laser was investigated. The side size of the slab laser medium is 2 mm × 20 mm. Based on the principle of the edge ray, a secondary concentrating system consisting of a rectangular parabolic mirror (RPM) and a rectangular dielectric-filled compound parabolic concentrator (RDCPC) was demonstrated. The focal length of RPM is 1200 mm and the size is 734 mm × 2000 mm. The outlet size of the RDCPC is 2 mm × 20 mm. The concentration effect was analyzed by using Tracepro optical software. The results showed that the concentration efficiency reached 81.3% and the uniformity of the spot was 91.4% after optimization. This design of concentration system is of great reference value for a solar side-pumped slab laser.

A Survey of Direct Normal Insolation Resources for the Construction of Solar Thermal Power Generation Sites in Korea (국내 태양열발전단지 건설을 위한 법선면 직달일사량 자원조사)

  • Jo, Dok-Ki;Kang, Young-Heack;Auh, Chung-Moo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.11-18
    • /
    • 2005
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1990 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research's new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $5.4kWh/m^2/day$ of the direct normal insolation was evaluated for clear day all over 16 areas in Korea. 2) Clear day's direct normal insolation of spring and summer were $5.53kWh/m^2/day$ and $5.84kWh/m^2/day$, and for fall and winter their values were $5.3kWh/m^2/day$ and $4.94kWh/m^2/day$ respectively. So, spring and summer were higher, and fall and winter were lower than the yearly mean value.

A Feasibility Study of using Mini-dish Systems for Solar Power Generation (소형 태양 반사경 Cluster를 이용한 태양열 발전에 대한 타당성 연구)

  • Oh, Seung-Jin;Hyun, Joon-Ho;Chun, Won-Gee;Han, Hyun-Joo;Kim, Jeong-Tai
    • New & Renewable Energy
    • /
    • v.2 no.4 s.8
    • /
    • pp.39-45
    • /
    • 2006
  • This paper introduces a preliminary work for the design of a mini-dish cluster system for power generation. Each mini-dish [typically has a 20 to 30 cm in diameter] is designed with a simple parabolic profile concentrating sun light [after the glass glazing cover to avoid dust deposition on the reflector and facilitate cleaning] onto a centrally located small plane[or concave] mirror which is placed on the bottom side of a transparent glass cover. The mirror with a mini-dish concentrator is designed to focus beam radiation onto a focal point before it enters a bundle of optical fibers connected to a remote receiver for power generation. Different options are considered in designing a mini-dish concentrator to maximize its effectiveness for the collection and use of solar energy.

  • PDF

A Survey of Direct Normal Insolation Resources in Korea (Focused on All days Analysis) (국내 법선면 직달일사량 자원조사 (전일 분석을 중심으로))

  • Jo, Dok-Ki;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.51-56
    • /
    • 2008
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $2.67\;kWh/m^2/day$ of the direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were $2.91\;kWh/m^2/day$ and $2.23\;kWHm^2/day$, and for fall and winter their values were $2.78\;kWh/m^2/day$ and $2.77\;kWh/m^2/day$ respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value.

An Experimental Study on the Characteristics of Flux Density Distributions produced by Solar Concentrating System (태양열 집광기의 플럭스 밀도 분포 특성에 관한 연구)

  • Kang Myeongcheol;Kang Yongheack;Yoon Hwanki;Yu Changkyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.422-426
    • /
    • 2005
  • This experimental study represents the results of an analysis on the characteristics of flux density distribution in the focal region of solar concentrator. The characteristics of flux density distributions are investigated to optimally design and position a cavity receiver. This was deemed very useful to find and correct various errors associated with a dish concentrator. We estimated the flux density distribution on the target placed along with focal lengths from the dish vertex to experimentally determine the focal length. It is observed that the actual focal point exists when the focal length is 2.17m. The total integrated power and percent power was 2467W and $85.8\%$, respectively, in the case of small dish, and also 2095W and $79\%$, respectively, in the case of KIERDISH II. As a result of the percent power within radius, approximately $90\%$ of the incident radiation is intercepted by about 0.06 m radius. The minimum radius of receiver in KIERDISH II is found to be 0.15m and approximately $90\%$ of the incident radiation is intercepted by receiver aperture.

  • PDF