• 제목/요약/키워드: Computer-aided design and computer-aided manufacturing (CAD-CAM)

검색결과 215건 처리시간 0.026초

Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing

  • Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.2.1-2.7
    • /
    • 2018
  • With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

전치부 개방교합을 보이는 법랑질형성부전증 환자의 CAD/CAM system을 이용한 전악 수복 증례 (Full-mouth rehabilitation in an amelogenesis imperfecta patient with anterior open bite using CAD/CAM system)

  • 이상훈;이양진;조득원
    • 대한치과보철학회지
    • /
    • 제55권4호
    • /
    • pp.410-418
    • /
    • 2017
  • 법랑질 형성 부전증은 유전적인 결함으로 인해 구조적으로 약한 법랑질이 형성되는 질환이다. 이들 환자들은 이른 나이부터 진행되는 법랑질 마모에 의한 시린 증상과 비심미적인 치아를 주소로 치과에 내원하게 되며, 성장기 이후에는 전악 보철 수복을 통해 치아의 기능성과 심미성을 회복해 주게 된다. 법랑질 형성 부전증 환자에서 보여지는 전치부 개방 교합은, 구치의 교합면 마모 및 보상성 맹출에 의한 수직적 수복 공간 문제와 결부되어 보철 치료를 어렵게 하는 요인이 된다. 따라서 전치 길이의 결정 및 교합 고경의 거상 여부, 전방유도의 설정은 신중히 결정되어야 한다. 근래에는 Computer aided design-computer aided manufacturing (CAD/CAM) 기술을 이용하여 진단 및 최종 수복으로의 이행이 용이해 졌다. 본 증례에서는 전치부 개방교합을 가지고 있는 법랑질 형성 부전증 환자에서, CAD/CAM을 이용한 전악 수복을 시행한 후, 양호한 경과를 보이고 있기에 이를 보고하고자 한다.

적층가공을 이용한 임시의치 제작 및 기존방식의 임시의치와의 비교 증례 (Fabrication of additive manufacturing interim denture and comparison with conventional interim denture: A case report)

  • 김현아;임현필;강현;양홍서;박상원;윤귀덕
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.483-489
    • /
    • 2019
  • 디지털치의학의 발달과 함께 computer-aided design and computer-aided manufacturing (CAD/CAM)을 이용한 3D 제작산업이 최근 급격한 성장을 하고 있다. 디지털 방식을 이용한 의치 제작 또한 최근의 디지털치의학 기술의 발전으로 증가하는 추세에 있다. CAD/CAM 제작방법은 크게 두가지 타입으로 나눌 수 있다: 절삭가공, 적층가공, 밀링과 같은 절삭가공은 블록 형태의 재료를 깎아 제조하는 기술을 토대로 하며, 3D printing과 같은 적층가공은 재료를 적층 방식으로 쌓아 올려 제조하는 기술을 토대로 한다. 적층가공은 밀링이 어려운 복잡한 구조의 제작에 적용할 수 있다. 본 증례에서, 적층가공방법이 레진상 총의치 제작에 이용되었다. 디지털방식을 적용한 의치의 사용기간동안 기능적, 심미적으로 만족할 만한 결과를 보여주었다.

구치부 지지 소실 및 무너진 교합관계를 보이는 환자에서 Dental CAD-CAM system을 활용한 완전 구강 회복 증례 (Full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion utilizing dental CAD-CAM system)

  • 정지원;허성주;김성균;곽재영
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.44-54
    • /
    • 2022
  • 다수 치아의 상실 상태로 장시간 지속시 구치부 지지의 부족 및 치아들의 과정출이 발생되어 교합 부조화, 수직고경 상실 및 기능 장애 등의 심각한 문제가 초래된다. 본 증례는 장기간 다수치아 결손으로 인하여 대합치가 정출하면서 교합평면의 붕괴가 일어난 환자의 완전 구강 회복에 관한 증례이다. 상기 환자는 서울대학교 치과병원 치과보철과로 내원한 68세 남환으로 오래된 상악 의치를 빼다가 치아가 함께 발거되었으며, 하악 전치부가 상악 전치부와 강하게 닿아서 불편함을 호소하며 내원하였다. 여러가지 평가를 통해 수직고경을 4 mm 거상하였으며, 무치악부는 진단 및 치료계획시 설계한 최종 보철 수복물 제작을 고려하여 정확한 임플란트 식립을 위해 CAD-CAM (Computer-aided design-computer-aided manufacturing) 기술을 이용한 Computer guided implant surgery를 시행하고, 임플란트 고정성 보철 수복으로 진행하였고, 환자는 저작, 기능 및 심미 모두 큰 개선에 만족하였다.

Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses

  • Barbin, Thais;Silva, Leticia Del Rio;Veloso, Daniele Valente;Borges, Guilherme Almeida;Presotto, Anna Gabriella Camacho;Barao, Valentim Adelino Ricardo;Groppo, Francisco Carlos;Mesquita, Marcelo Ferraz
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.329-337
    • /
    • 2020
  • PURPOSE. To verify the influence of computer-aided design/computer-aided manufacturing (CAD/CAM) implant-supported prostheses manufactured with cobalt-chromium (Co-Cr) and zirconia (Zr), and whether ceramic application, spark erosion, and simulation of masticatory cycles modify biomechanical parameters (marginal fit, screw-loosening torque, and strain) on the implant-supported system. MATERIALS AND METHODS. Ten full-arch fixed frameworks were manufactured by a CAD/CAM milling system with Co-Cr and Zr (n=5/group). The marginal fit between the abutment and frameworks was measured as stated by single-screw test. Screw-loosening torque evaluated screw stability, and strain analysis was explored on the implant-supported system. All analyses were performed at 3 distinct times: after framework manufacturing; after ceramic application in both materials' frameworks; and after the spark erosion in Co-Cr frameworks. Afterward, stability analysis was re-evaluated after 106 mechanical cycles (2 Hz/150-N) for both materials. Statistical analyses were performed by Kruskal-Wallis and Dunn tests (α=.05). RESULTS. No difference between the two materials was found for marginal fit, screwloosening torque, and strain after framework manufacturing (P>.05). Ceramic application did not affect the variables (P>.05). Spark erosion optimized marginal fit and strain medians for Co-Cr frameworks (P<.05). Screw-loosening torque was significantly reduced by masticatory simulation (P<.05) regardless of the framework materials. CONCLUSION. Co-Cr and Zr frameworks presented similar biomechanical behavior. Ceramic application had no effect on the biomechanical behavior of either material. Spark erosion was an effective technique to improve Co-Cr biomechanical behavior on the implant-supported system. Screw-loosening torque was reduced for both materials after masticatory simulation.

심한 치아 마모와 수복 공간 부족을 보이는 환자에서 CAD/CAM 기술을 활용한 완전 구강 회복: 증례 보고 (Computer-aided design and manufacturing-based full mouth rehabilitation for a patient with excessive attrition and restricted vertical dimension: A case report)

  • 조준호;윤형인;여인성;한중석
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.495-505
    • /
    • 2019
  • 본 증례는 다수의 치아 상실과 심한 치아 마모로 인해 교합 고경(occlusal vertical dimension)의 감소 및 수복 공간 부족을 보이는 환자에 대한 computer-aided design and computer-aided manufacturing (CAD/CAM) 기술을 활용한 완전 구강 회복 치료이다. 진단 단계에서 교합 고경에 대한 여러 분석을 통해 교합 고경 증가를 통한 완전 구강 회복을 계획하였다. 새롭게 설정된 교합 고경을 반영한 임시 수복물을 환자에게 적용하여 적응시키고, 이중 스캔 방법을 통해 임시 수복물의 정보를 최종 수복물에 옮긴 후, 3D 프린팅을 통해 금속 코핑을 제작하여 최종 고정성 금속 도재 수복물을 완성하였다. 이후 전자 서베잉과 3D 프린팅을 통해 가철성 국소의치 금속 구조물을 제작, 최종 가철성 국소의치로 환자치료를 완료하였다. 이러한 디지털 기술을 활용한 완전 구강 회복 치료로 환자는 기능적, 심미적으로 만족하였고, 술자는 임상적으로 받아들일 만한 치료결과로 판단하였다.

Influence of different universal adhesives on the repair performance of hybrid CAD-CAM materials

  • Demirel, Gulbike;Baltacioglu, Ismail Hakki
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.23.1-23.9
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the microshear bond strength (${\mu}SBS$) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with a composite resin. Materials and Methods: Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The ${\mu}SBS$ of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at p < 0.05. Results: The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (p < 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (p < 0.05). Conclusions: The ${\mu}SBS$ values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The ${\mu}SBS$ values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.

CAD/CAM으로 제작된 지르코니아 코어의 지대치 형태에 따른 변연 및 내면 적합도에 관한 연구 (Marginal and internal fit according to the shape of the abutment of a zirconia core manufactured by computer-aided design/computer-aided manufacturing)

  • 김지수;류재경
    • 대한치위생과학회지
    • /
    • 제5권1호
    • /
    • pp.13-19
    • /
    • 2022
  • Background: In this study, zirconia copings were fabricated by setting clinically acceptable inner values for prostheses using computer-aided design/computer-aided manufacturing (CAD/CAM). The processed copings were evaluated for the marginal and internal fit of each abutment shape with a CAD program using the silicone replica technique. Methods A total of 20 copings was produced by selecting models commonly used in clinical practice. After injecting the sample, the minimum thickness, internal adhesion interval, and distance to the margin line were set to 0.5, 0.05, and 1.00 mm using a dental CAD program, respectively. It was measured using a 2D section function in a three-way program of the silicon replication technology. Although the positions and number of measurements of the anterior and posterior regions differed, nine parts of each pre-tube were designated and measured by referring to a previous study to compare the two samples. Results As a result, the average margin of the mesial, distal, and buccal (labial) surfaces was 59.90 ㎛ in the anterior region and 60.40 ㎛ in the posterior region. The mean axial wall margin was 67.25 ㎛ in the anterior region and 69.25 ㎛ in the posterior region. In occlusion, the anterior teeth (77.70 ㎛), posterior teeth (77.60 ㎛), and both anterior and posterior regions were within the clinically acceptable range. Conclusion The edge and inner fit of zirconia coping manufactured using the CAD/CAM system showed clinically applicable results. To reduce errors and increase accuracy, materials and machine errors that affect the manufacture of prosthetics should be investigated. Based on our results, the completeness of prosthetics could increase if the inner value and characteristics of the material are adjusted when applied in clinical practice.

CAE를 이용한 파인블랭킹 성형 해석 (Analysis of Fineblanking Forming using CAE)

  • 이관영;남기우
    • 동력기계공학회지
    • /
    • 제15권4호
    • /
    • pp.60-64
    • /
    • 2011
  • Computer-aided engineering (CAE) is the broad usage of computer software to aid in engineering tasks. It includes computer-aided design (CAD), computer-aided analysis (CAA), computer-integrated manufacturing (CIM), computer-aided manufacturing (CAM), material requirements planning (MRP), and computer-aided planning (CAP). In this study, the stress of mold analyzed using CAE technique. Punch loads were same difference between 0.5 % and 1.0 % of clearance, but punch load was decreased according to increasing of clearance. Punch load of pre-piercing process worked a little smaller than piercing process. Therefore, the hole of fine blanking process is also more efficient to manufacture the true size after pre-piercing.