• 제목/요약/키워드: Computer-aided design/computer-aided manufacturing (CAD/CAM)

검색결과 215건 처리시간 0.026초

Evaluation of the reproducibility of various abutments using a blue light model scanner

  • Kim, Dong-Yeon;Lee, Kyung-Eun;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.328-334
    • /
    • 2018
  • PURPOSE. To evaluate the reproducibility of scan-based abutments using a blue light model scanner. MATERIALS AND METHODS. A wax cast abutment die was fabricated, and a silicone impression was prepared using a silicone material. Nine study dies were constructed using the prepared duplicable silicone, and the first was used as a reference. These dies were classified into three groups and scanned using a blue light model scanner. The first three-dimensional (3D) data set was obtained by scanning eight dies separately in the first group. The second 3D data set was acquired when four dies were placed together in the scanner and scanned twice in the second group. Finally, the third 3D data set was obtained when eight dies were placed together in the scanner and scanned once. These data were then used to define the data value using third-dimension software. All the data were then analyzed using the non-parametric Kruskal-Wallis H test (${\alpha}=.05$) and the post-hoc Mann-Whitney U-test with Bonferroni's correction (${\alpha}=.017$). RESULTS. The means and standard deviations of the eight dies together were larger than those of the four dies together and of the individual die. Moreover, significant differences were observed among the three groups (P<.05). CONCLUSION. With larger numbers of abutments scanned together, the scan becomes more inaccurate and loses reproducibility. Therefore, scans of smaller numbers of abutments are recommended to ensure better results.

Microtensile bond strength and micromorphologic analysis of surface-treated resin nanoceramics

  • Park, Joon-Ho;Choi, Yu-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.275-284
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate the influence of different surface treatment methods on the microtensile bond strength of resin cement to resin nanoceramic (RNC). MATERIALS AND METHODS. RNC onlays (Lava Ultimate) (n=30) were treated using air abrasion with and without a universal adhesive, or HF etching followed by a universal adhesive with and without a silane coupling agent, or tribological silica coating with and without a universal adhesive, and divided into 6 groups. Onlays were luted with resin cement to dentin surfaces. A microtensile bond strength test was performed and evaluated by one-way ANOVA and Tukey HSD test (${\alpha}$=.05). A nanoscratch test, field emission scanning electron microscopy, and energy dispersive X-ray spectroscopy were used for micromorphologic analysis (${\alpha}$=.05). The roughness and elemental proportion were evaluated by Kruskal-Wallis test and Mann-Whitney U test. RESULTS. Tribological silica coating showed the highest roughness, followed by air abrasion and HF etching. After HF etching, the RNC surface presented a decrease in oxygen, silicon, and zirconium ratio with increasing carbon ratio. Air abrasion with universal adhesive showed the highest bond strength followed by tribological silica coating with universal adhesive. HF etching with universal adhesive showed the lowest bond strength. CONCLUSION. An improved understanding of the effect of surface treatment of RNC could enhance the durability of resin bonding when used for indirect restorations. When using RNC for restoration, effective and systemic surface roughening methods and an appropriate adhesive are required.

다층 지르코니아를 이용한 임플란트 전치부 수복 증례 (Restoration of anterior teeth with dental implant using multilayer zirconia)

  • 이성희;이영후;홍성진;백장현;노관태;배아란;권긍록;김형섭
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.469-477
    • /
    • 2021
  • 상악 전치부 임플란트의 성공적인 수복을 위해서는 pink esthetics와 white esthetics가 모두 충족되어야 한다. Pink esthetics 부분의 경우 적절한 임시보철물의 역할이 중요하고, white esthetics 부분의 경우에는 최종 보철물의 색상과 형태가 중요하다. 다층 지르코니아는 기존의 단일구조 지르코니아에 비해 절단 부위의 투명도가 높기 때문에 추가적인 도재 축성 없이 자연스러운 보철물 제작이 가능하다. 따라서 본 증례에서는 상악 전치를 상실한 환자에서 적절한 임시보철물을 통해 기능과 심미성을 충분히 회복한 후 다층 지르코니아를 통해 white esthetics를 달성하였다.

단일 치관 수복 시 구강스캐너를 이용한 교합평가 활용 증례보고 (A case report of single crown restoration using an intraoral scanner for occlusal evaluation)

  • 송준범;이종혁;하승룡;최유성;최선영
    • 대한치과보철학회지
    • /
    • 제59권3호
    • /
    • pp.341-349
    • /
    • 2021
  • 디지털 방식을 이용한 교합평가는 종래의 방식인 교합지와 occlusion foil 등에 비해 기록, 비교, 분석 등이 쉽고 간편하며 객관적 이라는 장점이 있다. 이에 본 증례보고에서는 교합평가에 디지털 기술을 활용하고자 단일 전장관 수복이 필요한 환자에서 구강스캐너(i500, Medit, Seoul, Korea)를 이용하여 매 내원시 교합을 평가하였으며, 비교를 위하여 교합지를 이용한 교합관계 확인과 디지털 교합분석장비(Dental prescale II, GC corporation, Tokyo, Japan)를 이용하여 교합관계를 평가하였다. 치료과정에서 구강스캐너를 이용한 방법과 기존의 교합지를 이용한 방법이 유사한 결과를 보여 향후 임상적으로 유용하게 사용될 수 있을 것으로 사료되었다.

Peri-implantitis 환자에서의 전악 재수복 증례 (Full mouth rehabilitation in a patient with peri-implantitis: A case report)

  • 최낙현;조영은;박은진
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.416-424
    • /
    • 2019
  • 임플란트 주위염(peri-implantitis)은 임플란트 치료를 받은 환자의 20%가량에서 발병하며, 시간이 지날수록 유병률이 증가한다. 경도 또는 중등도의 임플란트 주위염은 비수술적 또는 수술적 방법을 통해 치료될 수 있으나 심한 치조골 흡수를 동반한 경우 임플란트 제거(explanation)를 동반한 재건이 요구된다. 임플란트 주위염은 재발 가능성이 높아 치료계획 단계에서부터 임플란트 주위염의 재발을 방지하기 위한 고려가 필요하다. 본 증례는 임플란트 주위염과 만성치주염으로 진단된 환자의 증례로, 다수의 임플란트 제거 및 다수 치아 발치 후 상악은 임플란트 유지 피개의치, 하악은 임플란트 고정성 보철로 전악 수복하였다. 임플란트 주위염의 재발을 예방하기 위한 수술적, 보철적 방법을 통해 성공적으로 수복하였기에 이를 보고하고자 한다.

지르코니아의 거칠기 증가를 위한 다양한 표면처리방법이 레진 시멘트와의 전단결합강도에 미치는 영향 (Effects of various zirconia surface treatments for roughness on shear bond strength with resin cement)

  • 배강호;배지현;허중보;최재원
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.326-333
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effects of various zirconia surface treatment methods on shear bond strength with resin cements. Methods: We prepared 120 cylindrical zirconia specimens (⌀10 mm×10 mm) using computer-aided design/computer-aided manufacturing (CAD/CAM). Each specimen was randomly subjected to one of four surface treatment conditions: (1) no treatment (control), (2) airborne-particle abrasion with 50 ㎛ of Al2O3 (A50), (3) airborne-particle abrasion with 125 ㎛ of Al2O3 (A125), and (4) ZrO2 slurry (ZA). Using a polytetrafluoroethylene mold (⌀6 mm×3 mm), we applied three resin cements (Panavia F 2.0, Super-Bond C&B, and Variolink N) to each specimen. The shear bond strength tests were performed in a universal testing machine. The surfaces of representative specimens of each group were evaluated under scanning electron microscope. We used one-way analysis of variance (ANOVA), two-way ANOVA, and post hoc Tukey honest significant difference test to analyze the data. Results: In the surface treatment method, the A50 group showed the highest bond strength, followed by A125, ZA, and control groups; however, no significant difference was observed between A50 and A125, A125 and ZA, and ZA and control (p>0.05). Among the resin cements, Super-Bond C&B showed the highest shear bond strength, followed by Panavia F 2.0 and Variolink N (p<0.05). Conclusion: Within the limitations of this study, application of airborne-particle abrasion and ZrO2 slurry improved the shear bond strength of resin cement on zirconia.

과도한 구치부 마모를 보이는 환자에서 digital guided tooth preparation을 이용한 완전 구강 회복 증례 (Full mouth rehabilitation of a worn dentition using digital guided tooth preparation: a case report)

  • 김용규;여인성;윤형인;이재현;한중석
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.80-90
    • /
    • 2022
  • 디지털 치의학이 발전함에 따라 치과 치료 방식도 다양하게 변화하고 있다. 본 증례에서는 구치부의 병적인 마모로 수직 고경 소실을 보이는 환자에서 적절한 수직 고경을 설정한 후, 디지털 기술을 이용하여 최종 보철물을 사전에 디자인하였다. 이를 바탕으로 치질을 최대로 보존할 수 있도록 치아 삭제량을 계산하였으며, 구내에서 치아 삭제량을 나타내줄 수 있는 가이드를 디자인하였다. 본 가이드를 이용함으로써 복잡한 다수 치아의 삭제가 편리했으며 보다 정확하고 빠른 치아 형성이 가능하였다. 이후 이중 스캔으로 임시 보철물의 정보를 반영하여 전악 지르코니아 크라운으로 최종 보철물을 제작하였다. 디지털 기술을 이용하여 전악 수복 증례의 술 전 계획부터 최종 보철물 장착까지의 복잡한 과정을 빠르고 간편하게 해결할 수 있어, 환자와 술자가 모두 만족할 수 있었다.

가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교 (Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system)

  • 이완선
    • 구강회복응용과학지
    • /
    • 제40권2호
    • /
    • pp.72-81
    • /
    • 2024
  • 목적: 본 연구의 목적은 가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형을 이용해 치과용 캐드캠 시스템(CAD/CAM)으로 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내부 적합성을 평가하고자 하였다. 연구 재료 및 방법: 하악 우측 제1소구치와 하악 우측 제1대구치에 지르코니아 크라운을 위한 치아 삭제 프로토콜을 수행하고, 하악 우측 제2소구치가 없는 레퍼런스 모델을 만들었다. 레퍼런스 모델은 폴리비닐 실록산 인상체를 사용하여 복제되었고, 일반적인 치과 기공 절차에 따라 20개의 작업 모형이 제작되었다. 비교 분석을 위해, 10개의 지르코니아 3본 고정성 치과 보철물은 가철성 다이 시스템에서, 나머지 10개는 솔리드 작업 모형에서 제작되었다. 모든 작업 모형은 치과용 데스크탑 스캐너를 사용하여 디지털화되었고, 캐드 소프트웨어에서 보철물을 설계하였다. 최종 3본 고정성 치과 보철물은 밀링 과정을 통해 제작되었다. 변연 및 내부 적합도 평가는 레퍼런스 모델에 제작된 보철물을 위치시키고, 디지털 평가 방법으로 적합도가 측정되었다. 두 그룹 간의 통계 비교를 위해 Mann-Whitney U 검정이 적용되었다(α = 0.05). 결과: 가철성 다이 그룹은 솔리드 작업 모형 그룹에 비해 소구치와 대구치에서 유의하게 높은 적합도 차이를 보였으며(P < 0.05), 특히 변연 및 교합 간격에서 유의하게 높은 편차를 보였다. 색상 편차 맵에서도 가철성 다이 그룹이 변연 및 교합 영역에서 더욱 높은 편차를 보였다. 결론: 3본 고정성 치과 보철물의 적합도 차이는 가철성 다이 시스템의 작업 모형 상에서 제작된 치과 보철물에서 초래되었으며, 이를 통해 가철성 다이 제작 방법이 치과 고정성 보철물의 정확성에 영향이 있었음을 검증하였다.

완전 무치악 환자에서 임시 의치와 치과용 CAD-CAM을 활용한 전악 고정성 임플란트 회복 증례 (Complete mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and dental CAD-CAM)

  • 전솔;윤형인;이재현;여인성;한중석
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.100-109
    • /
    • 2022
  • 임플란트를 이용한 수복 치료에서 장기적인 안정을 얻기 위해서는 임플란트의 식립 시 보철 수복에 이상적인 위치와 각도로 식립하는 것이 중요하다. 이를 위해서는 정확한 치료계획에 따른 수술과 보철 치료가 이루어져야 한다. 본 증례에서는 캐드캠 기술을 이용해 수술 계획 수립, 고정성 임시 보철물 및 최종 보철물 제작을 진행하였다. 최종 보철물을 고려하여 제작한 수술용 가이드로 임플란트를 식립하였다. 임시 의치가 가진 환자의 심미적 정보를 고정성 임시 보철물과 최종 보철물의 제작에 활용하였다. 최종적으로 단일구조 지르코니아를 이용한 전악 임플란트 고정성 보철 수복으로 기능 및 심미적으로 환자가 만족할만한 결과를 얻을 수 있었다.

디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가 (Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner)

  • 이종원;박지만
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.210-217
    • /
    • 2016
  • 목적: 본 연구의 목적은 실제 환자에서 디지털 구강스캐너로 모형 없이 제작한 보철물의 변연 및 내면 적합도를 평가하는 것이다. 대상 및 방법: 전향적 임상시험으로 시행한 본 예비 연구는 총 11개의 수복물을 대상으로 하였다. 구강스캐너(TRIOS, 3shape, Copenhagen, Denmark)로 디지털 구강인상을 채득한 후, 캐드 디자인 및 밀링 가공 과정을 통해 전부지르코니아 수복물을 제작하였다. 완성된 지르코니아관을 환자 구강 내에 시적하였고, 레플리카 술식으로 보철물-지대치 복제물을 얻었다. 이를 근원심, 협설 방향으로 잘라 변연오차, 변연간극과 축벽부, 선각부, 교합면부의 내면간극을 측정하였다. 통계처리는 Kruskal-Wallis 검정과 Mann-Whitney U 검정을 이용하여 통계적 유의성을 분석하였다(${\alpha}=.05$). 결과: 복제물을 통한 적합도 분석 결과, 근원심, 협설 절편 사이에는 통계적으로 유의한 차이가 없었다(P>.05). 변연간극에 불일치가 있었으며, 변연 오차가 변연간극 보다 컸다(P<.01). 결론: 본 연구의 한계 내에서, 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 적합도는 임상적으로 허용할만한 결과를 보였다. 그러나 지르코니아관의 변연부위가 과풍융되는 경향이 있었으므로 주의 깊은 임상 적용 및 추적 연구가 요구된다.