• Title/Summary/Keyword: Computer assisted image processing

Search Result 42, Processing Time 0.029 seconds

The accuracy of reformatted images using a new virtual 3-dimensional dental implant system (국내에서 개발된 3차원 임플란트 가상시술 시스템에 의한 영상재구성상의 정확도)

  • Choi Jin-Seok;Kim Eun-Kyung;Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.33 no.3
    • /
    • pp.187-193
    • /
    • 2003
  • Purpose: To compare the measurements of the mandible and the detectability of the mandibular canal on reformatted images using a newly developed 3-dimensional implant simulation program with traditionally used CT multiplanar reconstruction program and true measurements. Materials and Methods: Ten dry dog mandibles were used in this study. Occlusal templates for CT examination were fabricated and marked with gutta perch a at ten sites. Axial CT scans were taken and reconstructed using DentaScan (D group) and Vimplant program (V group), and each mandible was sectioned at the previously marked sites (R group). Maximum vertical height (H) and maximum width (W) of the mandible, the distances from buccal border of the mandibular canal to the most buccal aspect of the mandible (X), and the distance from the superior border of the mandibular canal to the alveolar crest (Y) were measured, and the mandibular measurements in each group were compared. Detectability of mandibular canal was evaluated using a 3-point scale in both V and D groups by three oral radiologists and compared. Results: H in the V group was slightly greater than that in the D group, and Wand X in the V group was slightly less than those in the D group. H in the V group was less than that in the R group, and Wand X in the V group was larger than those in the R group. The detectability of the mandibular canal did not show statistically significant differences between V and D groups. Conclusion: The results of the experiment show that the newly developed, inexpensive Vimplant/TM/ simulation program can be used as an alternative to the traditionally used, and more expensive CT multiplanar reconstruction program.

  • PDF

Effects of Imagery Tennis Training on Cerebral Activity

  • Jung, Seokwon;Choi, Min-sun;Kim, Min-uk;An, Hye-jin;Shin, Min-gyeong;Kwon, Oh-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.1
    • /
    • pp.46-50
    • /
    • 2015
  • The previous studies showed that the visual imagery activated the occipital and posterior inferior temporal area of the brain, and the damage to the occipital cortex impaired the visual mental imagery. We studied current-source distribution of electroencephalography (EEG) to observe neuronal activity during imagery tennis playing. Eleven healthy volunteers were enrolled. All volunteers were right-handed males and novices for tennis playing. The mean age of them was 24.9 years. The EEGs were recorded on the scalp electrodes located according to the International 10~20 System. The number of electrodes was 25 channels including subtemporal electrodes. The EEG recording session was 13 min including 5 segments: resting-I, scenery-slide show, resting-II, watching tennis-game video, and imagery-tennis playing. The recoding durations were 3, 2, 3, 2, and 3 min respectively. Five 'artifact free 3-sec segments' were selected in each segment of 'imagery-tennis playing' and 'resting-II'. We did the frequency domain analysis with the EEG segments using a distributed model of current-source analysis. The statistical-nonparametric maps (SnPMs) were obtained between the segments of 'imagery-tennis playing' and the segments of 'resting-II' (p<0.01). The significant change of current-source density was observed only in alpha-2 frequency band (10~12 Hz). The current-sourcedensity was increased in the hippocampus, parahippocampus, and occipital fusiform gyrus in the right cerebral hemisphere (p<0.01). Imaginary-tennis playing may activate the hippocampal-occipital alpha networks of nondominant hemisphere.

Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

  • Kang, Sung-Won;Lee, Woo-Jin;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.7-13
    • /
    • 2015
  • Purpose: We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). Materials and Methods: The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. Results: VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). Conclusion: It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

Morphological analysis of maxillary sinus septum using computed tomography (컴퓨터단층촬영을 이용한 상악동 중격의 형태학적 분석)

  • Chae, Jong-Beom;Lee, Sang-Han;Kim, Chin-Soo;Kim, Jong-Bae;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.1
    • /
    • pp.36-42
    • /
    • 2011
  • Introduction: The current study examined the morphological characteristics of maxillary sinus septum by computed tomography (CT). Materials and Methods: Two hundred and four patients (408 maxillary sinuses) who visited dental clinic were evaluated. CT were examined. The height of the septum measured from the sinus floor to the apex of the septum more than 3 mm was defined as "sinus septum". Results: The prevalence of sinus septa was 21.3% (87/408), and 31.4% (64/204) of patients had more than 1 sinus septum. Females showed higher and thinner sinus septa than males. The anatomic location of the septa were distributed in the 2nd molar region (43.7%), 1st molar region (31.0%), 2nd premolar region (21.8%) and 1st premolar region (3.5%). In 57 patients with chronic disease, there was no significant difference between sinus disease and the presence of sinus septa. The loss of remaining teeth and teeth adjacent to the sinus septum area was not related to the presence of sinus septa. Older subjects showed a reduced height and length of the septum, and a thicker septum. Conclusion: These results show that the maxillary sinus septum undergoes atrophy with age.

Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

  • Oliveira, Matheus L.;Tosoni, Guilherme M.;Lindsey, David H.;Mendoza, Kristopher;Tetradis, Sotirios;Mallya, Sanjay M.
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.279-285
    • /
    • 2014
  • Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of $K_2HPO_4$ were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the $K_2HPO_4$ solutions were measured. The relationship between CT number and $K_2HPO_4$ concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between $K_2HPO_4$ concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study

  • Fattouh, Mohamed;Kenawi, Laila Mohamed Mohamed;Fattouh, Hesham
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.399-406
    • /
    • 2021
  • Purpose: This in vitro study measured and compared 3 intraoral scanners' accuracy (trueness and precision) with different span lengths. Materials and Methods: Three master casts were prepared to simulate 3 different span lengths (fixed partial dentures with 3, 4, and 5 units). Each master cast was scanned once with an E3 lab scanner and 10 times with each of the 3 intraoral scanners (Trios 3, Planmeca Emerald, and Primescan AC). Data were stored as Standard Tessellation Language (STL) files. The differences between measurements were compared 3-dimensionally using metrology software. Data were analyzed using 1-way analysis of variance with post hoc analysis by the Tukey honest significant difference test for trueness and precision. Statistical significance was set at P<0.05. Results: A statistically significant difference was found between the 3 intraoral scanners in trueness and precision (P<0.05). Primescan AC showed the lowest trueness and precision values(36.8 ㎛ and 42.0 ㎛;(39.4 ㎛ and 51.2 ㎛; and 54.9 ㎛ and 52.7 ㎛) followed by Trios 3 (38.9 ㎛ and 53.5 ㎛; 49.9 ㎛ and 59.1 ㎛; and 58.1 ㎛ and 64.5 ㎛) and Planmeca Emerald (60.4 ㎛ and 63.6 ㎛; 61.3 ㎛ and 69.0 ㎛; and 70.8 ㎛ and 74.3 ㎛) for the 3-unit, 4-unit, and 5-unit fixed partial dentures, respectively. Conclusion: Primescan AC had the best trueness and precision, followed by Trios 3 and Planmeca Emerald. Increasing span length reduced the trueness and precession of the 3 scanners; however, their values were within the accepted successful ranges.

Ideal Nasal Preferences: A Quantitative Investigation with 3D Imaging in the Iranian Population

  • Kiarash Tavakoli;Amir K. Sazgar;Arman Hasanzade;Amir A. Sazgar
    • Archives of Plastic Surgery
    • /
    • v.50 no.4
    • /
    • pp.340-347
    • /
    • 2023
  • Background Though in facial plastic surgery, the ideal nasal characteristics are defined by average European-American facial features known as neoclassical cannons, many ethnicities do not perceive these characteristics as suitable. Methods To investigate the preferences for nasofrontal angle, nasolabial angle, dorsal height, alar width, and nasal tip projection, manipulated pictures of one male and one female model were shown to 203 volunteer patients from a tertiary university hospital's facial plastic clinic. Results The most aesthetically preferred nasofrontal angles were 137.64 ± 4.20 degrees for males and 133.55 ± 4.53 degrees for females. Acute nasofrontal angles were more desirable in participants aged 25 to 44. The most preferred nasolabial angles were 107.56 ± 5.20 degrees and 98.92 ± 4.88 degrees, respectively. Volunteers aged 19 to 24 preferred more acute male nasolabial angles. A straight dorsum was the most desirable in both genders (0.03 ± 0.78 and 0.26 ± 0.75 mm, respectively). The ideal male and female alar widths were -0.51 ± 2.26 and -1.09 ± 2.18 mm, respectively. More 45- to 64-year-old volunteers preferred alar widths equal to intercanthal distance. The ideal female and male tip projections were 0.57 ± 0.01 and 0.56 ± 0.01, respectively. Conclusion Results indicate that the general Iranian patients prefer thinner female noses with wider nasofrontal angles for both genders. However, the ideal nasolabial angles, dorsal heights, and tip projections were consistent with the neoclassical cannons. Besides ethnic differences, the trend of nasal beauty is also affected by gender, age, and prior history of aesthetic surgery.

Texture analysis in cone-beam computed tomographic images of medication-related osteonecrosis of the jaw

  • Polyane Mazucatto Queiroz;Karolina Castilho Fardim;Andre Luiz Ferreira Costa;Ricardo Alves Matheus;Sergio Lucio Pereira Castro Lopes
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.109-115
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate changes in the trabecular bone through texture analysis and compare the texture analysis characteristics of different areas in patients with medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: Cone-beam computed tomographic images of 16 patients diagnosed with MRONJ were used. In sagittal images, 3 regions were chosen: active osteonecrosis(AO); intermediate tissue (IT), which presented a zone of apparently healthy tissue adjacent to the AO area; and healthy bone tissue (HT) (control area). Texture analysis was performed evaluating 7 parameters: secondary angular momentum, contrast, correlation, sum of squares, inverse moment of difference, sum of entropies, and entropy. Data were analyzed using the Kruskal-Wallis test with a significance level of 5%. Results: Comparing the areas of AO, IT, and HT, significant differences (P<0.05) were observed. The IT and AO area images showed higher values for parameters such as contrast, entropy, and secondary angular momentum than the HT area, indicating greater disorder in these tissues. Conclusion: Through texture analysis, changes in the bone pattern could be observed in areas of osteonecrosis. The texture analysis demonstrated that areas visually identified and classified as IT still had necrotic tissue, thereby increasing the accuracy of delimiting the real extension of MRONJ.

Comparison of instrumental methods for color change assessment of Giomer resins

  • Luiza de Almeida Queiroz Ferreira;Rogeli Tiburcio Ribeiro da Cunha Peixoto ;Claudia Silami de Magalhaes;Tassiana Melo Sa;Monica Yamauti ;Francisca Daniele Moreira Jardilino
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.8.1-8.9
    • /
    • 2022
  • Objectives: The aim of this study was to compare the color change of the Giomer resin composite (Beautifil-Bulk) by using photographs obtained with a smartphone (iPhone 6S) associated with Adobe Photoshop software (digital method), with the spectrophotometric method (Vita Easyshade) after immersion in different pigment solutions. Materials and Methods: Twenty resin composite samples with a diameter of 15.0 mm and thickness of 1.0 mm were confectioned in A2 color (n = 5). Photographs and initial color readings were performed with a smartphone and spectrophotometer, respectively. Then, samples were randomly divided and subjected to cycles of immersion in distilled water (control), açai, Coke, and tomato sauce, 3 times a day, 20 minutes for 7 days. Later, new photographs and color readings were taken. Results: The analysis (2-way analysis of variance, Holm-Sidak, p < 0.05) demonstrated no statistical difference (p < 0.005) between the methods in all groups. Similar color changes were observed for all pigment solutions when using the spectrophotometric method. For the digital method, all color changes were clinically unacceptable, with distilled water and tomato sauce similar to each other and with statistical differences (p < 0.005) for Coke and açai. Conclusions: Only the tomato sauce produced a color change above the acceptability threshold using both methods of color assessment. The spectrophotometric and digital methods produce different patterns of color change. According to our results, the spectrophotometric method is more recommended in color change assessment.

A study of trabecular bone strength and morphometric analysis of bone microstructure from digital radiographic image (디지털방사선영상에서 추출한 해면질골의 강도와 미세구조의 형태계측학적 분석에 대한 연구)

  • Han Seung-Yun;Lee Sun-Bok;Oh Sung-Ook;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.113-119
    • /
    • 2003
  • Purpose : To evaluate the relationship between morphometric analysis of bone microstructure from digital radiographic image and trabecular bone strength. Materials and Methods : One hundred eleven bone specimens with 5 mm thickness were obtained from the mandibles of 5 pigs. Digital images of specimens were taken using a direct digital intraoral radiographic system. After selection of ROI (100 × 100 pixel) within the trabecular bone, mean gray level and standard deviation were obtained. Fractal dimension and the variants of morphometric analysis (trabecular area, periphery, length of skeletonized trabeculae, number of terminal point, number of branch point) were obtained from ROI. Punch sheer strength analysis was performed using Instron (model 4465, Instron Corp., USA). The loading force (loading speed 1 mm/min) was applied to ROI of bone specimen by a 2 mm diameter punch. Stress-deformation curve was obtained from the punch sheer strength analysis and maximum stress, yield stress, Young's modulus were measured. Results: Maximum stress had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). Yield stress had a negative linear correlation with mean gray level, periphery, fractal dimension and the length of skeletonized trabeculae significantly (p < 0.05). Young's modulus had a negative linear correlation with mean gray level and fractal dimension significantly (p < 0.05). Conclusions : The strength of cancellous bone exhibited a significantly linear relationship between mean gray level, fractal dimension and morphometric analysis. The methods described above can be easily used to evaluate bone quality clinically.

  • PDF