Establishment of Valve Replacement Registry and Risk Factor Analysis Based on Database Application Program (데이터베이스 프로그램에 기반한 심장판막 치환수술 환자의 레지스트리 확립 및 위험인자 분석)

  • Kim, Kyung-Hwan;Lee, Jae-Ik;Lim, Cheong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.209-216
    • /
    • 2002
  • Background: Valvular heart disease is still the most common health problem in Korea. By the end of the year 1999, there has been 94,586 cases of open heart surgery since the first case in 1958. Among them, 36,247 cases were acquired heart diseases and 20,704 of those had valvular heart disease. But there was no database system and every surgeon and physician had great difficulties in analysing and utilizing those tremendous medical resources. Therefore, we developed a valve registry database program and utilize it for risk factor analysis and so on. Material and Method: Personal computer-based multiuser database program was created using Microsoft AccessTM. That consisted of relational database structure with fine-tuned compact field variables and server-client architecture. Simple graphic user interface showed easy-to-use accessability and comprehensibility. User-oriented modular structure enabled easier modification through native AccessTM functions. Infinite application of query function aided users to extract, summarize, analyse and report the study result promptly. Result: About three-thousand cases of valve replacement procedure were performed in our hospital from 1968 to 1999. Total number of prosthesis replaced was 3,700. The numbers of cases for mitral, aortic and tricuspid valve replacement were 1600, 584, 76, respectively. Among them, 700 patients received prosthesis in more than two positions. Bioprosthesis or mechanical prosthesis were used in 1,280 and 1,500 patients respectively Redo valve replacements were performed in 460 patients totally and 40 patients annually Conclusion: Database program for registry of valvular heart disease was successfully developed and used in personal computer-based multiuser environment. This revealed promising results and perspectives in database management and utilization system.

Use of deep learning in nano image processing through the CNN model

  • Xing, Lumin;Liu, Wenjian;Liu, Xiaoliang;Li, Xin;Wang, Han
    • Advances in nano research
    • /
    • v.12 no.2
    • /
    • pp.185-195
    • /
    • 2022
  • Deep learning is another field of artificial intelligence (AI) utilized for computer aided diagnosis (CAD) and image processing in scientific research. Considering numerous mechanical repetitive tasks, reading image slices need time and improper with geographical limits, so the counting of image information is hard due to its strong subjectivity that raise the error ratio in misdiagnosis. Regarding the highest mortality rate of Lung cancer, there is a need for biopsy for determining its class for additional treatment. Deep learning has recently given strong tools in diagnose of lung cancer and making therapeutic regimen. However, identifying the pathological lung cancer's class by CT images in beginning phase because of the absence of powerful AI models and public training data set is difficult. Convolutional Neural Network (CNN) was proposed with its essential function in recognizing the pathological CT images. 472 patients subjected to staging FDG-PET/CT were selected in 2 months prior to surgery or biopsy. CNN was developed and showed the accuracy of 87%, 69%, and 69% in training, validation, and test sets, respectively, for T1-T2 and T3-T4 lung cancer classification. Subsequently, CNN (or deep learning) could improve the CT images' data set, indicating that the application of classifiers is adequate to accomplish better exactness in distinguishing pathological CT images that performs better than few deep learning models, such as ResNet-34, Alex Net, and Dense Net with or without Soft max weights.

Computer-Aided Diagnosis Parameters of Invasive Carcinoma of No Special Type on 3T MRI: Correlation with Pathologic Immunohistochemical Markers (3T 자기공명영상에서 비특이 침윤성 유방암의 컴퓨터보조진단 인자들과 병리적 면역조직화학 표지자들과의 상관성)

  • Jinho Jeong;Chang Suk Park;Jung Whee Lee;Kijun Kim;Hyeon Sook Kim;Sun-Young Jun;Se-Jeong Oh
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.149-161
    • /
    • 2022
  • Purpose To investigate the correlation between computer-aided diagnosis (CAD) parameters in 3-tesla (T) MRI and pathologic immunohistochemical (IHC) markers in invasive carcinoma of no special type (NST). Materials and Methods A total of 94 female who were diagnosed with NST carcinoma and underwent 3T MRI using CAD, from January 2018 to April 2019, were included. The relationship between angiovolume, curve peak, and early and late profiles of dynamic enhancement from CAD with pathologic IHC markers and molecular subtypes were retrospectively investigated using Dwass, Steel, Critchlow-Fligner multiple comparison analysis, and univariate binary logistic regression analysis. Results In NST carcinoma, a higher angiovolume was observed in tumors of higher nuclear and histologic grades and in lymph node (LN) (+), estrogen receptor (ER) (-), progesterone receptor (PR) (-), human epidermal growth factor 2 (HER2) (+), and Ki-67 (+) tumors. A high rate of delayed washout and a low rate of delayed persistence were observed in Ki-67 (+) tumors. In the binary logistic regression analysis of NST carcinoma, a high angiovolume was significantly associated with a high nuclear and histologic grade, LN (+), ER (-), PR (-), HER2 (+) status, and non-luminal subtypes. A high rate of washout and a low rate of persistence were also significantly correlated with the Ki-67 (+) status. Conclusion Angiovolume and delayed washout/persistent rate from CAD parameters in contrast enhanced breast MRI correlated with predictive IHC markers. These results suggest that CAD parameters could be used as clinical prognostic, predictive factors.

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.