• Title/Summary/Keyword: Computer Power Supply

Search Result 517, Processing Time 0.023 seconds

Implementation of inside the computer power supply with UPS (UPS 기능을 갖는 내장형 컴퓨터 전원장치의 구현)

  • Lee S. R.;Ko S. S.;Mun J. M.;Kwon H. D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.202-205
    • /
    • 2003
  • Recently, UPS(Uninterruptible Power Supply) have been largely used to improve power souse quality as well as to protect critical loads such as computer, industrial system, medical equipment, etc, against power outage by providing clean and uninterrupted power under power supply disturbance or interruptions. But UPS is bulky because used battery. So, UPS size issue have received attention in the power electronics industry. Therefore, this paper proposed a implementation of inside of the computer power supply with UPS by the one-chip microprocessor to minimize UPS size. To verify the proposed power supply, the detail simulation and experiment results indicate that high-frequency switching and operation UPS can be achieved.

  • PDF

Development of UPS System Embedded in Computer Power Supply Using GUI (GUI를 이용한 컴퓨터 Power Supply 내장형 UPS 시스템의 개발)

  • Roh, Inh-Bae;Park, Jee-Ho;Hwang, Gi-Hyun;Kim, Dong-Wan;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.4
    • /
    • pp.190-194
    • /
    • 2004
  • In this paper, UPS, which is embedded in computer power supply, is developed against the poor utility power system. In the developed system, PIC16C54 is used as the main controller, and UPS system consists of micom control module, power failure detecting module, charging module, power module, synchronous transfer module, and GUI module. Additionally, GUI module consists of battery charging state unit, power operating unit and operating state unit. The effectiveness of the developed system has been verified by the experimental results.

High-Efficiency Non-contact Power Supply System

  • Zheng, Bin;Kwan, Dae-Hwan;Lee, Dae-Sik
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.233-235
    • /
    • 2005
  • Non-contact power supply (NCPS), as a clean and safe energy supply concept has been applying wildly. Comparing with the conventional transformer the non-contact transformer has a large air gap between the long primary winding and the secondary winding. Due to it, the non-contact transformer has increased leakage inductance and reduced magnetizing inductance. So the high frequency series resonant converter has been widly used on the non-contact power supply system for transferring the primary power to the secondary one, from what a high influence voltage can be gained on the secondry coil even though the large air gap exists. However, it still has the disadvantages of the load sensitive voltage gain characteristics when load is changing. In this paper, we propose a fuzzy logic controller to adjust the frequency of the inverter to track the resonat which is changing when the load is change.

  • PDF

Clock Scheduling and Cell Library Information Utilization for Power Supply Noise Reduction

  • Kim, Yoo-Seong;Han, Sang-Woo;Kim, Ju-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.1
    • /
    • pp.29-36
    • /
    • 2009
  • Power supply noise is fundamentally caused by large current peaks. Since large current peaks are induced by simultaneous switching of many circuit elements, power supply noise can be minimized by deliberate clock scheduling which utilizes nonzero clock skew. In this paper, nonzero skew clock scheduling is used to avoid the large peak current and consequently reduce power supply noise. While previous approaches require extra characterization efforts to acquire current waveform of a circuit, we approximate it only with existing cell library information to be easily adapted to conventional design flow. A simulated annealing based algorithm is performed, and the peak current values are estimated for feasible clock schedules found by the algorithm. The clock schedule with the minimum peak current is selected for a solution. Experimental results on ISCAS89 benchmark circuits show that the proposed method can effectively reduce the peak current.

Development of a Multiple SMPS System Controlling Variable Load Based on Wireless Network

  • Ko, Junho;Park, Chul-Won;Kim, Yoon Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1221-1226
    • /
    • 2015
  • This paper proposes a multiple switch mode power supply (SMPS) system based on the wireless network which controls variable load. The system enables power supply of up to 600W using 200W SMPS as a unit module and provides a controlling function of output power based on variable load and a monitoring function based on wireless network. The controlling function for output power measures the variation of output power and facilitates efficient power supply by controlling output power based on the measured variation value. The monitoring function guarantees a stable power supply by observing the multiple SMPS system in real time via wireless network. The performance of the proposed system was examined by various experiments. In addition, it was verified through standardized test of Korea Testing Certification. The results were given and discussed.

Smart Power Management Using RTOS-based Uninterruptable Generator Supply

  • Lee, Chulju;Kang, Kyungtae;Noh, Dong Kun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.6
    • /
    • pp.1-7
    • /
    • 2016
  • An uninterruptible power supply (UPS) allows small companies and domestic users to cope with power outages; but existing designs lack flexibility of control and require expensive battery maintenance, with a cost proportional to the outage compensation time. We combine a compact synchronous generator with a battery, with 10% of the capacity that would otherwise be required, to obtain a UPS with reduced maintenance costs for the same performance. Any UPS must respond immediately to a power loss, and our uninterruptible generator supply (UGS) is therefore built around real-time scheduling of its internal operations; this also makes it suitable for integration into the industrial gateway. The UGS is based on a real-time operating system, with an integrated wireless module providing connectivity to a web server, for monitoring and management, which can be performed remotely on a mobile device.

CLUSTER ANALYSIS FOR REGION ELECTRIC LOAD FORECASTING SYSTEM

  • Park, Hong-Kyu;Kim, Young-Il;Park, Jin-Hyoung;Ryu, Keun-Ho
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.591-593
    • /
    • 2007
  • This paper is to cluster the AMR (Automatic Meter Reading) data. The load survey system has been applied to record the power consumption of sampling the contract assortment in KEPRI AMR. The effect of the contract assortment change to the customer power consumption is determined by executing the clustering on the load survey results. We can supply the power to customer according to usage to the analysis cluster. The Korea a class of the electricity supply type is less than other country. Because of the Korea electricity markets exists one electricity provider. Need to further divide of electricity supply type for more efficient supply. We are found pattern that is different from supplied type to customer. Out experiment use the Clementine which data mining tools.

  • PDF

The SMPS with a Bulit-in UPS for Computer (UPS를 내장한 컴퓨터용 SMPS)

  • 이성룡;전칠환;이수원;고성훈;권혁대
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.8
    • /
    • pp.495-499
    • /
    • 2004
  • UPS(Uninterruptible Power Supply) have been used to improve power source quality as well as to protect critical loads such as computer, industrial system, medical equipment, etc, by providing clean and uninterrupted power under power supply disturbance or interruptions. But UPS is bulky because batteries. So, a UPS size issue has received the attention in the power electronics industry. This paper proposed an implementation of the computer power supply with a bulit-in UPS controlled by the one-chip microprocessor to minimize UPS size. The experimental results verified the proposed SMPS with a bulit-in UPS for computer.

Phase-Locked Loop with Leakage and Power/Ground Noise Compensation in 32nm Technology

  • Kim, Kyung-Ki;Kim, Yong-Bin;Lee, Young-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.4
    • /
    • pp.241-246
    • /
    • 2007
  • This paper presents two novel compensation circuits for leakage current and power supply noise (PSN) in phase locked loop (PLL) using a nanometer CMOS technology. The leakage compensation circuit reduces the leakage current of the charge pump circuit and the PSN compensation circuit decreases the effect of power supply variation on the output frequency of VCO. The PLL design is based on a 32nm predictive CMOS technology and uses a 0.9 V power supply voltage. The simulation results show that the proposed PLL achieves 88% jitter reduction at 440 MHz output frequency compared to the PLL without leakage compensator and its output frequency drift is little to 20% power supply voltage variations. The PLL has an output frequency range of 40 $M{\sim}725$ MHz with a multiplication range of 1-1023, and the RMS and peak-to-peak jitter are 5psec and 42.7 psec, respectively.

A Low power Scheduling and Allocation Algorithm for Multiple Supply Voltage (다중 공급 전압을 이용한 저 전력 스케쥴링 및 할당 알고리듬)

  • 최지영;박남서;안도희
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.2
    • /
    • pp.79-86
    • /
    • 2002
  • This paper presents a low power scheduling and allocation algorithm for multiple supply voltage. The proposed supply voltage scheduling algorithm determines the control step to execute a possible the operation experimentally using another supply voltage level. Also, the switching activity using component library. and the supply voltage allocation method uses the graph coloring technique for low power, the proposed algorithm Proves the effect through various high level benchmark examples to adopt a multiple supply voltage scheduling algorithm for low power.

  • PDF