• Title/Summary/Keyword: Computer Aided Design

Search Result 1,318, Processing Time 0.029 seconds

Oral rehabilitation of a patient with severely worn dentition using monolithic zirconia (단일구조 지르코니아 보철물을 이용한 심한 마모 환자의 전악 수복 증례)

  • Park, Jun-Seo;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.273-279
    • /
    • 2016
  • Severe tooth wear may lead to pathological changes of pulp, imbalance in occlusion as well as functional and esthetic problems. In this case, 34-year-old male came to the hospital because of generally worn dentition due to attrition and erosion. After evaluation, a full mouth restoration with elevation of the vertical dimension of occlusion was planned. After occlusion was stabilized by an occlusal stabilization appliance, centric relation position was recorded and subsequent provisional restorations were fabricated. After evaluation, a CAD-CAM (computer aided design-computer aided manufacturing) prosthetic restoration was carried out using monolithic zirconia. After 12 months of follow up observation, the patient was satisfied with function and esthetic appearance.

Superimposition: a simple method to minimize occlusal adjustment of monolithic restoration (디지털 장비의 중첩기능을 이용하여 단일체 수복물의 교합조정을 최소화한 증례)

  • Choi, Changhun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.253-258
    • /
    • 2016
  • The development of translucent zirconia enabled clinicians to choose a monolithic zirconia crown as one treatment modality in the posterior dentition. Careful occlusal adjustments are recommended for monolithic zirconia crowns because grinding zirconia inevitably causes phase transformation, which may deteriorate mechanical properties. intraoral scanners enable the clinician to scan and superimpose a complete tooth structure before preparation onto the prepared abutment. This technique helps to reproduce the original tooth form and occlusion of the patient. In this case report, prostheses were fabricated for patients with cracked or fractured tooth by applying intraoral scanner, Computer aided design-computer aided manufacturing (CAD-CAM) and monolithic zirconia crown to reproduce the occlusion of original tooth and to minimize occlusal adjustment. The clinical results were satisfactory in both esthetic and functional aspects.

Mandibular implant-supported overdenture using CAD-CAM Konus type attachment: A case report (CAD-CAM Konus type 부착장치를 이용한 하악 임플란트 피개의치 보철수복 증례)

  • Park, Jong-Hee;Kim, In-Ju;Kim, Kyoung-A;Song, Kwang-Yeob;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.259-266
    • /
    • 2016
  • In edentulous mandible, implant supported overdenture was considered as a first treatment option. Konus type attachment supplies rigid support and cross arch stabilization so that more favorable force transmission and distribution can be attained. In the dentistry, computer aided design-computer aided manufacturing (CAD-CAM) system makes it possible to fabricate restorations with high precision and effectiveness. Recently, Palladium-silver (Pd-Ag) alloy which is millable has been developed. This article presents that application of CAD-CAM Konus type attachment can be provide satisfactory stability and function on four-implant supported mandibular overdenture.

Evaluation of the repair capacities and color stabilities of a resin nanoceramic and hybrid CAD/CAM blocks

  • Bahadir, Hasibe Sevilay;Bayraktar, Yusuf
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.140-149
    • /
    • 2020
  • PURPOSE. This study evaluated the color stabilities of two computer-aided design and computer-aided manufacturing (CAD/CAM) blocks and a nanofill composite resin and the microtensile bond strength (µTBS) between the materials. MATERIALS AND METHODS. Twelve specimens of 4 mm height were prepared for both Lava Ultimate (L) and Vita Enamic (E) CAD/CAM blocks. Half of the specimens were thermocycled (10,000 cycle, 5° to 55℃) for each material. Both thermocycled and non-thermocycled specimens were surface treated with one of the three different methods (Er,Cr:YSGG laser, bur, or control). For each surface treatment group, one of the thermocycled and one of non-thermocycled specimens were restored using silane (Ceramic Primer II), universal adhesive (Single Bond Universal), and nanofill composite resin of 4-mm height (Filtek Ultimate). The other specimens were restored with the same procedure without using silane. For each group, 1 × 1 × 8 mm bar specimens were prepared using a microcutting device. Bar specimens were thermocycled (10,000 cycle, 5° to 55℃) and microtensile tests were performed. Staining of the materials in coffee solution was also compared using a spectrophotometer. Data were analyzed using one-way ANOVA, t-test and post-hoc Scheffe tests. RESULTS. µTBS were found similar between the thermocycled and non-thermocycled groups (P>.05). The highest µTBS (20.818 MPa) was found in the non-thermocycled, bur-ground, silane-applied E group. Silane increased µTBS at some E groups (P<.05). Composite resin specimens showed more staining than CAD/CAM blocks (P<.05). CONCLUSION. CAD/CAM blocks can be repaired with composite resins after proper surface treatments. Using silane is recommended in repair process. Color differences may be shown between CAD/CAM blocks and the nanofill composite after a certain time period.

The effect of sandblasting duration on the bond durability of dual-cure adhesive cement to CAD/CAM resin restoratives

  • Tekce, Neslihan;Tuncer, Safa;Demirci, Mustafa
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.211-217
    • /
    • 2018
  • PURPOSE. To evaluate the effect of prolonged sandblasting on the bond durability of dual-cure adhesive resin cement to computer-aided design and computer-aided manufacturing (CAD/CAM) restoratives. MATERIALS AND METHODS. Nano-ceramic LAVA Ultimate and hybrid-ceramic VITA Enamic CAD/CAM blocks were used for this study. Each CAD/CAM block was sectioned into slabs of 4-mm thickness for the microtensile test (${\mu}TBS$) test and 2-mm thickness for the surface roughness test. Three groups were created according to the sandblasting protocols; group 1: specimens were sandblasted for 15 seconds, group 2: specimens were sandblasted for 30 seconds, and group 3: specimens were sandblasted for 60 seconds. After sandblasting, all specimens were luted using RelyX Ultimate Clicker. Half the specimens were subjected to ${\mu}TBS$ tests at 24 hours, and the other half were subjected to tests after 5000 thermocycles. Additionally, a total of 96 CAD/CAM block sections were prepared for surface roughness tests and scanning electron microscopy (SEM) evaluations. The Mann-Whitney U test, Kruskal-Wallis one-way analysis of variance, and Dunn's post hoc test were used to compare continuous variables among the groups. RESULTS. At baseline, group 1, group 2, and group 3 exhibited statistically similar ${\mu}TBS$ results for LAVA. However, group 3 had significantly lower ${\mu}TBS$ values than groups 1 and 2 for VITA. After 5000 thermocycles, ${\mu}TBS$ values significantly decreased for each block (P<.05). CONCLUSION. It is important to perform controlled sandblasting because it may affect bond strength results. Sixty seconds of sandblasting disturbs the initial ${\mu}TBS$ values and the stability of adhesion of CAD/CAM restoratives to dual-cure adhesive resin cement for VITA Enamic.

The effect of light sources and CAD/CAM monolithic blocks on degree of conversion of cement

  • Cetindemir, Aydan Boztuna;Sermet, Bulent;Ongul, Deger
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.291-299
    • /
    • 2018
  • PURPOSE. To assess the degree of conversion (DC) and light irradiance delivered to light-cured and dual-cured cements by application of different light sources through various types of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) materials. MATERIALS AND METHODS. RelyX Ultimate Clicker light-cured and dual-cured resin cement specimens with 1.5-mm thicknesses (n=300, 10/group), were placed under four types of crystalline core structure (Vita Enamic, Vita Suprinity, GC Ceresmart, Degudent Prettau Anterior). The specimens were irradiated for 40 seconds with an LED Soft-Start or pulse-delay unit or 20 seconds with a QTH unit. DC ratios were determined by using Fourier transform infrared spectroscopy (FTIR) after curing the specimen at 1 day and 1 month. The data were analyzed using the Mann-Whitney U test (for paired comparison) and the Kruskal-Wallis H test (for multiple comparison), with a significance level of P<.05. RESULTS. DC values were the highest for RelyX Ultimate Clicker light-cure specimens polymerized with the LED Soft-Start unit. The combination of the Vita Suprinity disc and RelyX Ultimate Clicker dual-cure resin cement yielded significantly higher values at both timepoints with all light units (all, P<.05). CONCLUSION. Within the limitations of this study, we conclude that the DC of RelyX Ultimate Clicker dual-cure resin cement was improved significantly by the use of Vita Suprinity and the LED Soft-Start light unit. We strongly recommend the combined use of an LED light unit and dual-cure luting cement for monolithic ceramic restorations.

Full mouth rehabilitation of a severely worn dentition using intraoral scanner and the CAD/CAM double scanning technique (중증도의 치아 마모 환자를 구내 스캐너와 이중스캔을 이용해 수복한 완전구강회복 증례)

  • Yoon, Se-Na;Han, Jung-Suk;Yeo, In-Sung;Yoon, Hyung-In
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.67-76
    • /
    • 2020
  • With the evolution of the computer-aided design/computer-aided manufacturing (CAD/CAM) technology, the intraoral scanners are playing an increasingly important role, as they are the first step towards a completely digital workflow. The CAD/CAM double scanning technique has been used to transfer the information from provisional restorations to definitive restorations. In this case, a 67-year-old male with esthetically compromised anterior teeth, generalized severe attrition of teeth, and reduced vertical dimension was treated with full mouth rehabilitation including a re-establishment of the lost vertical dimension of occlusion assisted by the crown lengthening procedure. The provisional restorations were fabricated using an intraoral scanner and the CAD/CAM double scanning technique. After the period of adaption, the definitive monolithic zirconia restorations were delivered. The CAD/CAM double scanning technique successfully transferred the occlusal and morphological characteristics, obtained from the provisional restorations, to the definitive restorations.