• Title/Summary/Keyword: Computed-assisted surgery

Search Result 88, Processing Time 0.033 seconds

Interfissural Fixation of the Right Middle Lobe after Video-Assisted Thoracic Surgery Right Upper Lobectomy: Bronchial Anatomical Changes and Efficacy in Preventing Torsion

  • Dong Jae Han;You Jung Ok;Se Jin Oh;Jae-Sung Choi;Yong Won Seong;Hyeon Jong Moon
    • Journal of Chest Surgery
    • /
    • v.57 no.5
    • /
    • pp.477-483
    • /
    • 2024
  • Background: Torsion of the right middle lobe following right upper lobectomy is a rare but potentially fatal complication. To prevent this, fixation of the right middle lobe has been suggested. This study was performed to examine the impact of right middle lobe fixation on postoperative outcomes and bronchial changes. Methods: We enrolled patients who underwent curative-intent video-assisted thoracic surgery (VATS) right upper lobectomy for lung cancer from 2019 to 2022. Participants were grouped based on whether they did or did not receive right middle lobe fixation. Bronchial angles were measured using preoperative and postoperative chest computed tomography images, and postoperative outcomes and bronchial changes were compared between the 2 groups. Results: The study included a total of 50 patients, with 17 (34%) undergoing right middle lobe fixation. All procedures were performed using VATS. No significant differences between groups were observed in preoperative characteristics or postoperative outcomes. After surgery, both groups exhibited a significant increase in the right bronchus intermedius angle and a significant decrease in the branch angle. The postoperative right bronchus intermedius angle was significantly larger in the group without right middle lobe fixation compared to the group with fixation (47.38°±10.98° vs. 39.41°±9.21°, p=0.014). Three cases of atelectasis occurred in the group that did not undergo fixation while no cases were observed in the fixation group; however, this difference was not statistically significant. Conclusion: Fixation of the right middle lobe reduced postoperative angulation of the right bronchus intermedius, which may help prevent postoperative atelectasis.

Long-Term Survival Following Port-Site Metastasectomy in a Patient with Laparoscopic Gastrectomy for Gastric Cancer: A Case Report

  • Kim, Sang Hyun;Kim, Dong Jin;Kim, Wook
    • Journal of Gastric Cancer
    • /
    • v.15 no.3
    • /
    • pp.209-213
    • /
    • 2015
  • A 78-year-old man underwent laparoscopy-assisted total gastrectomy for gastric cancer (pT3N0M0). Multiple port sites were used, including a 10 mm port for a videoscope at the umbilical point and three other working ports. During the six-month follow-up evaluation, a 2 cm enhancing mass confined to the muscle layer was found 12 mm from the right lower quadrant port site, suggesting a metastatic or desmoid tumor. Follow-up computed tomography imaging two months later showed that the mass had increased in size to 3.5 cm. We confirmed that there was no intra-abdominal metastasis by diagnostic laparoscopy and then performed a wide resection of the recurrent mass. The histologic findings revealed poorly differentiated adenocarcinoma, suggesting a metastatic mass from the stomach cancer. The postoperative course was uneventful, and the patient completed adjuvant chemotherapy with TS-1 (tegafur, gimeracil, and oteracil potassium). There was no evidence of tumor recurrence during the 50-month follow-up period.

A Case of Congenital Cystic Adenomatoid Malformation Infected with Mycobacterium avium-intracellulare Complex

  • Kim, Yong Jin;Kim, Do Young;Seo, Jung Woong;Lee, Song Am;Hwang, Jae Joon;Kim, Hee Joung;Lee, Kye Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.74 no.1
    • /
    • pp.28-31
    • /
    • 2013
  • We present a case of congenital cystic adenomatoid malformation (CCAM) in a 25-year-old male who was presented with chronic cough. Chest radiography revealed an abnormal mass-like shadow in the right lower pulmonary zone. A contrast enhanced computed tomography showed an 11 cm solid, cystic mixed mass on the right lower lobe. A right lower lobectomy was performed by video-assisted thoracoscopic surgery without complications. The gross specimen showed a massive cavitation with multiloculated cysts of varying size, consistent with CCAM, along with noticeable granulomatous inflammation. Non-tuberculosis mycobacteria were isolated from a bronchial wash specimen, and the resected tissue homogenates were positive for Mycobacterium avium-intracellulare complex by polymerase chain reaction.

Endoscopic Treatment of Iatrogenic Perforation of Sigmoid Diverticulum: A Case Report of Multidisciplinary Management

  • Giacomo Emanuele Maria Rizzo;Giuseppina Ferro;Giovanna Rizzo;Giovanni Di Carlo;Alessandro Cantone;Gaetano Giuseppe Di Vita;Carmelo Sciume
    • Clinical Endoscopy
    • /
    • v.55 no.2
    • /
    • pp.292-296
    • /
    • 2022
  • Iatrogenic perforations are severe complications of gastrointestinal endoscopy; therefore, their management should be adequately planned. A 77-year-old man with a history of diverticulosis underwent a colonoscopy for anemia. During the procedure, an iatrogenic perforation occurred suddenly in the sigmoid colon, near a severe angle among the numerous diverticula. Through-the-scope clips were immediately applied to treat it and close mucosal edges. Laboratory tests showed increased levels of inflammation and infection, and although there were no complaints of abdominal pain, the patient had an extremely distended abdomen. A multidisciplinary board began management based on a conservative approach. Pneumoperitoneum was treated with computed tomography-assisted drainage. After 72 hours, his intestinal canalization and laboratory tests were normal. Though this adverse event is rare, a multidisciplinary board should be promptly gathered upon occurrence, even if the patient appears clinically stable, to consider a conservative approach and avoid surgical treatment.

VATS Rib Resection in Benign Bone Tumor (늑골의 양성 종양환자에서 흉강경을 이용한 늑골 절제술)

  • Park, Chang-Ryul;Kim, Jeong-Won;Lee, Yong-Jik;Joo, Seok;Jung, Jong-Pil;Kim, Dae-Young
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.454-457
    • /
    • 2010
  • A 42 year old male was admitted for a bony mass on the posterior arc of the left $6^{th}$ rib, which was detected in a multiphasic health screening test. According to the chest computed tomography scan and bone scan, osteochondroma was suspected. He underwent VATS rib resection. There was no vessel or nerve injury. The patient was discharged without any complication on the $4^{th}$ post operative day. The pathological diagnosis was benign fibrous histiocytoma. Generally, posterolateral thoracotomy is needed for rib resection, but we found that there was no difficulty in doing this kind of surgery under a thoracoscopic approach, which has the advantage of better cosmesis.

Preliminary study on application of augmented reality visualization in robotic thyroid surgery

  • Lee, Dongheon;Kong, Hyoun-Joong;Kim, Donguk;Yi, Jin Wook;Chai, Young Jun;Lee, Kyu Eun;Kim, Hee Chan
    • Annals of Surgical Treatment and Research
    • /
    • v.95 no.6
    • /
    • pp.297-302
    • /
    • 2018
  • Purpose: Increased robotic surgery is attended by increased reports of complications, largely due to limited operative view and lack of tactile sense. These kinds of obstacles, which seldom occur in open surgery, are challenging for beginner surgeons. To enhance robotic surgery safety, we created an augmented reality (AR) model of the organs around the thyroid glands, and tested the AR model applicability in robotic thyroidectomy. Methods: We created AR images of the thyroid gland, common carotid arteries, trachea, and esophagus using preoperative CT images of a thyroid carcinoma patient. For a preliminary test, we overlaid the AR images on a 3-dimensional printed model at five different angles and evaluated its accuracy using Dice similarity coefficient. We then overlaid the AR images on the real-time operative images during robotic thyroidectomy. Results: The Dice similarity coefficients ranged from 0.984 to 0.9908, and the mean of the five different angles was 0.987. During the entire process of robotic thyroidectomy, the AR images were successfully overlaid on the real-time operative images using manual registration. Conclusion: We successfully demonstrated the use of AR on the operative field during robotic thyroidectomy. Although there are currently limitations, the use of AR in robotic surgery will become more practical as the technology advances and may contribute to the enhancement of surgical safety.

Clinical Characteristics and Management of Intrathoracic Bronchogenic Cysts: A Single Center Experience

  • Lee, Deok-Heon;Park, Chang-Kwon;Kum, Dong-Yoon;Kim, Jae-Bum;Hwang, Il-Seon
    • Journal of Chest Surgery
    • /
    • v.44 no.4
    • /
    • pp.279-284
    • /
    • 2011
  • Background: The aim of this study is to investigate the clinical characteristics and management of intrathoracic bronchogenic cysts. Materials and Methods: Twenty-four (n=24) patients with intrathoracic bronchogenic cysts were treated surgically between August 1990 and December 2009 at our institution. Patients were divided into two groups by bronchogenic cyst location: mediastinal or intrapulmonary. Symptoms at diagnosis, radiologic findings, locations, surgical methods, pathological findings, and surgical outcomes were investigated retrospectively from consecutive patient medical records. Results: There were 12 females (50.0%). The mean age was 26.8 (range, 5 to 64) years. The mean follow-up period was 27.3 (range, 1 to 121) months. There were 15 (62.5%) mediastinal and 9 (37.5%) intrapulmonary bronchogenic cysts. Symptoms occurred in 8 patients with mediastinal bronchogenic cysts (53.3%) and 5 patients with intrapulmonary bronchogenic cysts (55.6%) (p=1.000). On computed tomography (CT), 7 patients (46.7%) showed homogenous solid masses in mediastinal bronchogenic cysts and five (55.6%) patients exhibited heterogeneous cystic masses with air-fluid levels in intrapulmonary bronchogenic cystic masses. Open thoracotomy was performed in 17 (70.8%) patients, and video-assisted thoracic surgery was performed in 7 (29.2%) patients. On pathological findings, there were 16 (66.7%) complicated cysts, and in 13 symptomatic patients, 11 (84.6%) patients had complicated cysts. There was no operative death in this study. During the follow-up period, no recurrence was detected. Conclusion: Intrathoracic bronchogenic cysts have a wide variety of clinical characteristics and radiologic findings. Even though some patients do not experience symptoms and signs caused by bronchogenic cysts, serious symptoms and complications may develop with the passage of time.

Treatment of Beign Multiple Symmetrical Lipomatosis with Liposuction (지방흡입술을 이용한 양성 대칭성 지방종의 치험례)

  • Huh, Chul;Lim, So Young;Mun, Goo Hyun;Hyon, Won Sok;Bang, Sa Ik;Oh, Kap Sung
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.769-772
    • /
    • 2006
  • Purpose: Benign symmetrical lipomatosis(Madelung's disease) is a disease of uncertain etiology that manifests as massive lipomatous deposits in specific area of the body. It is usually located on the neck, shoulder, proximal regions of the extremities and the abdomen. Madelung's disease is found many in middle-aged, Mediterranean man. Imaging using either computed tomography or magnetic resonance imaging is often recommended. Dietary restriction provides no relief of disease. Abstinence with alcohol may delay further progression but does not regression tumor mass. The objective of this study is to prove effectiveness of liposuction for treatment of benign lipomatosis. Methods: We conducted liposuction as a treatment for benign lipomatosis. After general anesthesia, We conducted power assisted liposuction and amount of suctioned volume was about 2500 cc. After surgery, we did compressive dressing and then followed by pressure garment. Results: Six months after surgery, patient was examined for follow up at outpatient department. Recurred lipoma was not observated. Patient was satisfied with result.Conclusion: The only effective therapy for Madelung's disease is surgical removal but recurrence could be occurring. Also multiple surgical scars will be visible. We report a patient with multiple large lipomatosis successfully treated with liposuction.

Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study

  • Lee, Du-Hyeong;An, Seo-Young;Hong, Min-Ho;Jeon, Kyoung-Bae;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.207-213
    • /
    • 2016
  • PURPOSE. A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS. For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (${\alpha}=.05$). RESULTS. The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION. The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance.

Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

  • Oliveira, Matheus L.;Tosoni, Guilherme M.;Lindsey, David H.;Mendoza, Kristopher;Tetradis, Sotirios;Mallya, Sanjay M.
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.279-285
    • /
    • 2014
  • Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of $K_2HPO_4$ were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the $K_2HPO_4$ solutions were measured. The relationship between CT number and $K_2HPO_4$ concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between $K_2HPO_4$ concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.