• Title/Summary/Keyword: Computed tomography perfusion

Search Result 101, Processing Time 0.021 seconds

Evaluation of Hepatic Hemangioma by Tc-99m Red Blood Cell Hepatic Blood Pool Scan (간 혈관종의 Tc-99m 표지 적혈구 혈액풀 스캔)

  • Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.151-162
    • /
    • 2005
  • Hemangioma is the most common benign tumor of the liver, with a prevalence estimated as high as 7%. Tc-99m red blood cell (RBC) hepatic blood pool scan with single photon omission computed tomography (SPECT) imaging is extremely useful for the confirmation or exclusion of hepatic hemangiomas. The classic finding of absent or decreased perfusion and increased blood pooling ("perfusion/blood pool mismatch") is the key diagnostic element in the diagnosis of hemangiomas. The combination of early arterial flow and delayed blood pooling ("perfusion/blood pool match") is shown uncommonly. In giant hemangioma, filling with radioactivity appears first in the periphery, with progressive central fill-in on sequential RBC blood pool scan. However, the reverse filling pattern, which begins first in the center with progressive peripheral filling, is also rarely seen. Studies with false-positive blood pooling have been reported infrequently in nonhemangiomas, including hemangiosarcoma, hepatocellular carcinoma, hepatic adenoma, and metastatic carcinomas (adenocarcinoma of the colon, small cell carcinoma of the lung, neruroendocrine carcinoma). False-negative results have been also reported rarely except for small hemagniomas that are below the limits of spatial resolution of gamma camera.

Beyond Coronary CT Angiography: CT Fractional Flow Reserve and Perfusion (전산화단층촬영 관상동맥조영술: 분획혈류예비력과 심근관류 영상)

  • Moon Young Kim;Dong Hyun Yang;Ki Seok Choo;Whal Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.3-27
    • /
    • 2022
  • Cardiac CT has been proven to provide diagnostic and prognostic evaluation of coronary artery disease for cardiovascular risk stratification and treatment decision-making based on rapid technological development and various research evidence. Coronary CT angiography has emerged as a gateway test for coronary artery disease that can reduce invasive angiography due to its high negative predictive value, but the diagnostic specificity is relatively low. However, coronary CT angiography is likely to overcome its limitations through functional evaluation to identify the hemodynamic significance of coronary artery disease by analyzing myocardial perfusion and fractional flow reserve through cardiac CT. Recently, studies have been actively conducted to incorporate artificial intelligence to make this more objective and reproducible. In this review, functional imaging techniques of cardiac computerized tomography are explored.

Regional Brain Perfusion before and after Treatment with Methylphenidate According to the MspI Polymorphism of the Alpha-2A Adrenergic Receptor Gene in Children with Attention-Deficit Hyperactivity Disorder (주의력결핍 과잉행동장애 아동에서 α-2A 아드레날린 수용체 유전자의 MspI 유전자 다형성에 따른 메칠페니데이트 치료 전후 뇌관류 비교)

  • Park, Subin;Bae, Jeong-Hoon;Kim, Jae-Won;Yang, Young-Hui;Oh, Seungmin;Hong, Soon-Beom;Park, Min-Heyon;Kim, Boong-Nyun;Shin, Min-Sup;Yoo, Hee-Jeong;Cho, Soo-Churl
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.24 no.1
    • /
    • pp.21-27
    • /
    • 2013
  • Objectives : Dysregulation of the central noradrenergic system may be involved in the pathophysiology of attention-deficit hyperactivity disorder (ADHD). The aim of this study was to examine the differences in pre- and post-treatment cerebral perfusion according to the MspI polymorphisms of the alpha-2A-adrenergic receptor gene (ADRA2A) in children with ADHD. Methods : Thirty seven drug-naive ADHD children (8.9+1.8 years old, M=32, F=5) were genotyped. Baseline single-photon emission computed tomography (SPECT) and clinical assessments were performed for ADHD children. After treatment with methylphenidate for eight weeks, SPECT and clinical assessment were repeated. Results : No differences in baseline clinical assessments or cerebral perfusion were observed according to the MspI genotype. However, after treatment, ADHD children with the G/G genotype at the MspI polymorphism showed hyperperfusion in the right cerebellar declive (p=.001, uncorrected) and hypoperfusion in the left lentiform nucleus and left cingulate gyrus (p<.001 and p=.001, uncorrected), compared to children without the G/G genotype. Conclusion : Although the results of this study should be interpreted cautiously, they suggest a possible role of the MspI polymorphisms of the ADRA2A gene in methylphenidate-induced changes in cerebral perfusion.

Performance Evaluation of Automatic Segmentation based on Deep Learning and Atlas according to CT Image Acquisition Conditions (CT 영상획득 조건에 따른 딥 러닝과 아틀라스 기반의 자동분할 성능 평가)

  • Jung Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.213-222
    • /
    • 2024
  • This study analyzed the volumes generated by deep learning and atlas-based automatic segmentation methods, as well as the Dice similarity coefficient and 95% Hausdorff distance, according to the conditions of conduction voltage and conduction current in computed tomography for lung radiotherapy. The first result, the volumes generated by the atlas-based smart segmentation method showed the smallest volume change as a function of the change in tube voltage and tube current, while Aview RT ACS and OncoStudio using deep learning showed smaller volumes at tube currents lower than 100 mA. The second result, the Dice similarity coefficient, showed that Aview RT ACS was 2% higher than OncoStuido, and the 95% Hausdorff distance results also showed that Aview RT ACS analyzed an average of 0.2-0.5% higher than OncoStudio. However, the standard deviation of the respective results for tube current and tube voltage is lower for OncoStudio, which suggests that the results are consistent across volume variations. Therefore, caution should be exercised when using deep learning-based automatic segmentation programs at low perfusion voltages and low perfusion currents in CT imaging conditions for lung radiotherapy, and similar results were obtained with conventional atlas-based automatic segmentation programs at certain perfusion voltages and perfusion currents.

Evaluation of Myocardial Ischemia Using Coronary Computed Tomography Angiography in Patients with Stable Angina (안정형 협심증 환자들에서 관상동맥 전산화단층촬영을 이용한 심근허혈의 평가)

  • Sung Min Ko
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.250-271
    • /
    • 2020
  • Assessment of myocardial ischemia in patients with stable angina is important in deciding whether to treat coronary artery disease and in predicting clinical outcome. The fractional flow reserve is a standard reference for the diagnosis of myocardial ischemia, but this procedure has limitations because of its invasiveness. Coronary computed tomography angiography (CCTA) is now an established tool in the anatomic diagnosis of coronary artery disease; however, there are limits to the diagnosis of hemodynamically important stenosis that causes myocardial ischemia. In order to address this problem, studies using quantification of coronary atherosclerotic plaques, myocardial perfusion, and noninvasive calculation of fractional flow reserve based on CCTA have been actively conducted and recognized for their diagnostic value. In this review, several imaging techniques of CCTA used to assess myocardial ischemia are described.

Recurrent Bleeding in Hemorrhagic Moyamoya Disease : Prognostic Implications of the Perfusion Status

  • Jo, Kyung-Il;Kim, Min Soo;Yeon, Je Young;Kim, Jong-Soo;Hong, Seung-Chyul
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.2
    • /
    • pp.117-121
    • /
    • 2016
  • Objective : Hemorrhagic moyamoya disease (hMMD) is associated with a poor clinical course. Furthermore, poorer clinical outcomes occur in cases of recurrent bleeding. However, the effect of hemodynamic insufficiency on rebleeding risk has not been investigated yet. This study evaluated the prognostic implications of the perfusion status during the clinical course of adult hMMD. Methods : This retrospective study enrolled 52 adult hMMD patients between April 1995 and October 2010 from a single institute. Demographic data, clinical and radiologic characteristics, including hemodynamic status using single photon emission computed tomography (SPECT), and follow up data were obtained via a retrospective review of medical charts and imaging. Statistical analyses were performed to explore potential prognostic factors. Results : Hemodynamic abnormality was identified in 44 (84.6%) patients. Subsequent revascularization surgery was performed in 22 (42.3%) patients. During a 58-month (median, range 3-160) follow-up assessment period, 17 showed subsequent stroke (hemorrhagic n=12, ischemic n=5, Actuarial stroke rate $5.8{\pm}1.4%/year$). Recurrent hemorrhage was associated with decreased basal perfusion (HR 19.872; 95% CI=1.196-294.117) and omission of revascularization (10.218; 95%; CI=1.532-68.136). Conclusion : Decreased basal perfusion seems to be associated with recurrent bleeding. Revascularization might prevent recurrent stroke in hMMD by rectifying the perfusion abnormality. A larger-sized, controlled study is required to address this issue.

Microvascular Pulmonary Tumor Embolism Detected by Perfusion Images of Dual-Energy Computed Tomography (이중에너지 컴퓨터 단층촬영을 통해 진단된 폐의 미세혈관종양색전증)

  • Ok, Tae-Jin;Cho, Min-Soo;Jang, Sun-Joo;Park, Han-Seung;Park, Hwan-Sung;Park, Se-Jeong;Yoon, Shin-Kyo;Lee, Ho-Su;Baek, Chung-Hee;Kim, Gwang-Un;Kim, Dal-Yong;Hong, Yoon-Ki;Seo, Joon-Beom;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.1
    • /
    • pp.63-67
    • /
    • 2012
  • Although advances in multi-detector computed tomography (CT) technique make it possible to evaluate peripheral subsegmental pulmonary arteries, several studies have reported that small peripheral embolisms may still be missed. Recently, some reports demonstrated that dual-energy CT improved the capability to detect peripheral pulmonary embolism. We report a case of lymphoma presenting as disseminated microvascular pulmonary tumor embolism, detected by perfusion images using dual energy CT.

Microvascular Myocardial Ischemia in Patients With Diabetes Without Obstructive Coronary Stenosis and Its Association With Angina

  • Yarong Yu;Wenli Yang;Xu Dai;Lihua Yu;Ziting Lan;Xiaoying Ding;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1081-1092
    • /
    • 2023
  • Objective: To investigate the incidence of microvascular myocardial ischemia in diabetic patients without obstructive coronary artery disease (CAD) and its relationship with angina. Materials and Methods: Diabetic patients and an intermediate-to-high pretest probability of CAD were prospectively enrolled. Non-diabetic patients but with an intermediate-to-high pretest probability of CAD were retrospectively included as controls. The patients underwent dynamic computed tomography-myocardial perfusion imaging (CT-MPI) and coronary computed tomography angiography (CCTA) to quantify coronary stenosis, myocardial blood flow (MBF), and extracellular volume (ECV). The proportion of patients with microvascular myocardial ischemia, defined as any myocardial segment with a mean MBF ≤ of 100 mL/min/100 mL, in patients without obstructive CAD (Coronary Artery Disease-Reporting and Data System [CAD-RADS] grade 0-2 on CCTA) was determined. Various quantitative parameters of the patients with and without diabetes without obstructive CAD were compared. Multivariable analysis was used to determine the association between microvascular myocardial ischemia and angina symptoms in diabetic patients without obstructive CAD. Results: One hundred and fifty-two diabetic patients (mean age: 59.7 ± 10.7; 77 males) and 266 non-diabetic patients (62.0 ± 12.3; 167 males) were enrolled; CCTA revealed 113 and 155 patients without obstructive CAD, respectively. For patients without obstructive CAD, the mean global MBF was significantly lower for those with diabetes than for those without (152.8 mL/min/100 mL vs. 170.4 mL/min/100 mL, P < 0.001). The mean ECV was significantly higher for diabetic patients (27.2% vs. 25.8%, P = 0.009). Among the patients without obstructive CAD, the incidence of microvascular myocardial ischemia (36.3% [41/113] vs. 10.3% [16/155], P < 0.001) and interstitial fibrosis (69.9% [79/113] vs. 33.3% [8/24], P = 0.001) were significantly higher in diabetic patients than in the controls. The presence of microvascular myocardial ischemia was independently associated with angina symptoms (adjusted odds ratio = 3.439, P = 0.037) in diabetic patients but without obstructive CAD. Conclusion: Dynamic CT-MPI + CCTA revealed a high incidence of microvascular myocardial ischemia in diabetic patients without obstructive CAD. Microvascular myocardial ischemia is strongly associated with angina.

Influence of Ischemic Lesions on $^{99m}Tc$-HMPAO SPECT Findings in the Diagnosis of Alzheimer's Disease ($^{99m}Tc$-HMPAO SPECT를 이용한 알쯔하이머병의 진단에서 허혈성 뇌병변이 미치는 영향)

  • Lee, Kyung-Han;Lee, Myung-Chul;Lee, Dong-Soo;Kwon, June-Soo;Kim, Jong-Ho;Chung, June-Key;Woo, Jong-In;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.282-292
    • /
    • 1994
  • Brain perfusion SPECT shows typical regional perfusion abnormalities in Alzheimer's disease(AD) and is useful for its diagnosis. However, there is also arguement that these patterns show significant overlap with other causes, and the accuracy for SPECT in differentiating AD has shown conflicting results. We postulate that the variation in re-ported results are partly due to a difference in patient or control selection with special reference to the mixture of ischemic cerebral disease in the studied population. To deter-mine the effect of ischemic lesions and the nature of control subjects on SPECT studies for AD, we performed $^{99m}Tc$-HMPAO single photon emission computed tomography (SPECT) in 11 probable AD patients with a low (<4) Hachinski ischemic score and 12 non-demented age matched controls. Magnetic resonance imaging(MRI) disclosed ischemic cerebral lesions in 27% (3/11) of the PAD group and 25% (3/12) of the control group. Regional perfusion indices were quantitated from the SPECT images as follows and the distribution of perfusion indices from both groups were compared. This was repeated with controls after excluding those with significant ischemic lesions by MRI : regional perfusion index = average regional count/average cerebellar count All PAD patients showed perfusion abnormality in SPECT. However, 53% (10/12) of controls also showed perfusion at-normalities, and no pattern could reliably differentiate the two groups. After excluding controls with significant cerebral ischemia, the difference in temporal and parietal perfusion index was increased. A decreased tempore-parietal and any parietal or temporal per-fusion index had a sensitivity of 18% and 36% in detecting AD, respectively. When using a separate group of normal age mathced controls, the indices showed an even more difference in the temporal and parietal lobes and the sensitivity of a decreased tempore-parietal and any parietal or temporal perfusion index had a sensitivity of 36% and 55% in detecting AD, respectively. Thus, the type of control with special reference to the pres-once of ischemic cerebral lesions contribute significantly to the accuracy of perfusion SPECT in diagnosing AD. This nay have particular importance in the diagnosis of AD in populations where the prevalance of cerebrovascular disease is high.

  • PDF

Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT

  • Masafumi Takafuji;Kakuya Kitagawa;Masaki Ishida;Yoshitaka Goto;Satoshi Nakamura;Naoki Nagasawa;Hajime Sakuma
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.58-67
    • /
    • 2020
  • Objective: Third-generation dual-source computed tomography (3rd-DSCT) allows dynamic myocardial CT perfusion imaging (dynamic CTP) with a 10.5-cm z-axis coverage. Although the increased radiation exposure associated with the 50% wider scan range compared to second-generation DSCT (2nd-DSCT) may be suppressed by using a tube voltage of 70 kV, it remains unclear whether image quality and the ability to quantify myocardial blood flow (MBF) can be maintained under these conditions. This study aimed to compare the image quality, estimated MBF, and radiation dose of dynamic CTP between 2ndDSCT and 3rd-DSCT and to evaluate whether a 10.5-cm coverage is suitable for dynamic CTP. Materials and Methods: We retrospectively analyzed 107 patients who underwent dynamic CTP using 2nd-DSCT at 80 kV (n = 54) or 3rd-DSCT at 70 kV (n = 53). Image quality, estimated MBF, radiation dose, and coverage of left ventricular (LV) myocardium were compared. Results: No significant differences were observed between 3rd-DSCT and 2nd-DSCT in contrast-to-noise ratio (37.4 ± 11.4 vs. 35.5 ± 11.2, p = 0.396). Effective radiation dose was lower with 3rd-DSCT (3.97 ± 0.92 mSv with a conversion factor of 0.017 mSv/mGy∙cm) compared to 2nd-DSCT (5.49 ± 1.36 mSv, p < 0.001). Incomplete coverage was more frequent with 2nd-DSCT than with 3rd-DSCT (1.9% [1/53] vs. 56% [30/54], p < 0.001). In propensity score-matched cohorts, MBF was comparable between 3rd-DSCT and 2nd-DSCT in non-ischemic (146.2 ± 26.5 vs. 157.5 ± 34.9 mL/min/100 g, p = 0.137) as well as ischemic myocardium (92.7 ± 21.1 vs. 90.9 ± 29.7 mL/min/100 g, p = 0.876). Conclusion: The radiation increase inherent to the widened z-axis coverage in 3rd-DSCT can be balanced by using a tube voltage of 70 kV without compromising image quality or MBF quantification. In dynamic CTP, a z-axis coverage of 10.5 cm is sufficient to achieve complete coverage of the LV myocardium in most patients.