• Title/Summary/Keyword: Computed Tomography Equipment

Search Result 83, Processing Time 0.021 seconds

Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology (영상의학과 응급실내의 일반촬영장비와 전산화단층촬영장비 표면에서의 세균 오염에 관한 분석)

  • Hong, Dong-Hee;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.421-427
    • /
    • 2016
  • We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.

Quantitative Evaluation of Patient Positioning Error Using CBCT 3D Gamma Density Analysis in Radiotherapy

  • Lee, Soon Sung;Min, Chul Kee;Cho, Gyu Suk;Han, Soorim;Kim, Kum Bae;Jung, Haijo;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.149-155
    • /
    • 2017
  • Radiotherapy patients should maintain their treatment position as patient setup is very important for accurate treatment. In this study, we evaluated patient setup error quantitatively according to Cone-Beam Computed Tomography (CBCT) Gamma Density Analysis using Mobius CBCT. The adjusted setup error to the $QUASAR^{TM}$ phantom was moved artificially in the superior and lateral direction, and then we acquired the CBCT image according to the phantom setup error. To analyze the treatment setup error quantitatively, we compared values suggested in the CBCT system with the Mobius CBCT. This allowed us to evaluate the setup error using CBCT Gamma Density Analysis by comparing the planning CT with the CBCT. In addition, we acquired the 3D-gamma density passing rate according to the gamma density criteria and phantom setup error. When the movement was adjusted to only the phantom body or 3 cm diameter target inserted in the phantom, the CBCT system had a difference of approximately 1 mm, while Mobius CBCT had a difference of under 0.5 mm compared to the real setup error. When the phantom body and target moved 20 mm in the Mobius CBCT, there are 17.9 mm and 13.5 mm differences in the lateral and superior directions, respectively. The CBCT gamma density passing rate was reduced according to the increase in setup error, and the gamma density criteria of 0.1 g/cc/3 mm has 10% lower passing rate than the other density criteria. Mobius CBCT had a 2 mm setup error compared with the actual setup error. However, the difference was greater than 10 mm when the phantom body moved 20 mm with the target. Therefore, we should pay close attention when the patient's anatomy changes.

Development of Portable X-ray CT System II - CT Image Reconstruction of Wood using Density Distribution - (현장 적용이 가능한 X선 CT 시스템 개발 II- 밀도분포를 이용한 목재의 CT영상 구성 -)

  • Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-31
    • /
    • 2006
  • X-ray transit materials with straight path and the its intensity is proportional to the density of materials. Therefore, X-ray has been extensively used as a nondestructive evaluation (NDE) method in various fields. This study was carried out for development of a portable X-ray CT (computed-tomography) system to detect deteriorations of wood members in buildings. Based on the results of our previous study, a procedure of CT image reconstruction was established In order to verify the applicability of developed system, CT images of three wood disks were reconstructed by newly developed procedure and compared with the prototypes. From the results of this study, it was shown that the newly developed system could be used not only to determine the shape, size, and position of defects, but also to find the density distribution in cross section of wood structure members. The density distribution may be utilized to clarify the reason of wood deterioration and to provide the preventive method on how to treat or repair wood buildings. Because it was initial stage of system development, there were some limitations concerned with measuring equipment and image reconstruction algorithm. Especially, measuring time including equipment setup time was longer and measuring accuracy was lower than we expected. Therefore, we planned some additional studies on improvement of equipment and algorithm to enhance the capability of X-ray CT system.

A Study on the Optimum Amount of Contrast Media in Brain Angiography (뇌 혈관검사 시 적정 조영제량에 관한 연구)

  • Kim, Gyoo-Hyung;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.123-128
    • /
    • 2018
  • Recently, the use of contrast agents has been increasing as a broader range of tests and dynamic tests have become common due to the development of equipment and imaging techniques such as Multi-Detector CT. However, the side effects of using contrast agents have been reduced by the development of non-ionic contrast agents, but they are still occurring often. The purpose of this study was to propose a method to minimize the side effect of contrast agent by using the amount of contrast agent injected to the brain angiography test to suppress excessive use of contrast agent and analyze the amount of contrast agent. Patients who were prescribed Brain Angiography due to cerebrovascular disease, According to the results of the comparison of the results obtained by dividing into 4 groups of 10ml each according to the amount of contrast medium injected with contrast agent according to the BMI of the patient, BA and SNR were not different between groups, and even if the amount of contrast injection was reduced, there was no problem in the evaluation of CT angiography through 3D reconstruction. This result shows that even if the contrast medium is injected into the blood vessels of the patient first and then the contrast medium is used as the physiological saline solution, the contrast medium is reduced by 40% it can be expected to minimize.

Radiation safety management for diagnostic radiation generators and employees in animal hospitals in Korea (동물병원의 진단용 방사선 발생장치 및 방사선종사자 안전관리 실태 조사)

  • An, Hyo-Jin;Kim, Chung-Hyun;Kwon, Young-Jin;Kim, Don-Hwan;Wee, Sung-Hwan;Moon, Jin-San
    • Korean Journal of Veterinary Research
    • /
    • v.54 no.3
    • /
    • pp.151-157
    • /
    • 2014
  • A nationwide survey on radiation safety management in Korean animal hospitals was conducted. By 2013, 53 radiation generators were registered as veterinary medical devices (41 X-ray generators and 12 computed tomography scanners). Additionally there were six approved laboratories for radiation equipment and protection facility, and five approved laboratories for radiation exposure of employees, respectively. By March 2013, 2,030 out of 3,829 animal hospitals operated radiation-generating devices. Among these devices, 389 (19.2%) out of 2,030 were not labeled with the model name and 746 (36.7%) were not labeled with production dates. Thus, most veterinary X-ray generators were outdated (42.6%) and needed replacements. When periodic inspections of 2,018 animal hospitals were performed after revision of the Veterinarians Act in 2011, the hospitals were found to be equipped with appropriate radiation generators and protection facilities. Among 2,545 employees exposed to radiation at the hospitals, 93.9% were veterinarians, 4.3% were animal nurse technicians, and 18% held other positions. Among 169 employees supervised by administrators, none of those had a weekly maximum operating load that exceeded $10mA{\cdot}min$. This study suggests that the radiation safety management system of animal hospitals was general good.

A Robot End-effector for Biopsy Procedure Automation with Spring-Triggered Biopsy Gun Mechanism (스프링 격발형 생검총 구조를 가진 생검 시술 자동화 로봇 말단장치)

  • Won, Jong-Seok;Moon, Youngjin;Park, Sang Hoon;Choi, Jaesoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.590-596
    • /
    • 2016
  • Biopsy is a typical needle type intervention procedure performed under radiographic image equipment such as computed tomography (CT) and cone-beam CT. This minimal invasive procedure is a simple and effective way for identifying cancerous condition of a suspicious tissue but radiation exposure for the patients and interventional radiologists is a critical problem. In order to overcome such trouble and improve accuracy in targeting of the needle, there have been various attempts using robot technology. Those devices and systems, however, are not for full procedure automation in biopsy without consideration for tissue sampling task. A robotic end-effector of a master-slave tele-operated needle type intervention robot system has been proposed to perform entire biopsy procedure by the authors. However, motorized sampling adopted in the device has different cutting speed from that of biopsy guns used in the conventional way. This paper presents the design of a novel robotic mechanism and protocol for the automation of biopsy procedure using spring-triggered biopsy gun mechanism. An experimental prototype has been successfully fabricated and shown its feasibility of the automated biopsy sequence.

Evaluation of an Experimentally Designed Stereotactic Guidance System for Determining Needle Entry Point during Uniplanar Fluoroscopy-guided Intervention

  • Lee, Jae-Heon;Jeon, Gye-Rok;Ro, Jung-Hoon;Byoen, Gyeong-Jo;Kim, Tae-Kyun;Kim, Kyung-Hoon
    • The Korean Journal of Pain
    • /
    • v.25 no.2
    • /
    • pp.81-88
    • /
    • 2012
  • Background: In discography performed during percutaneous endoscopic lumbar discectomy (PELD) via the posterolateral approach, it is difficult to create a fluoroscopic tunnel view because a long needle is required for discography and the guide-wire used for consecutive PELD interrupts rotation of fluoroscope. A stereotactic system was designed to facilitate the determination of the needle entry point, and the feasibility of this system was evaluated during interventional spine procedures. Methods: A newly designed stereotactic guidance system underwent a field test application for PELD. Sixty patients who underwent single-level PELD at L4-L5 were randomly divided into conventional or stereotactic groups. PELD was performed via the posterolateral approach using the entry point on the skin determined by premeasured distance from the midline and angles according to preoperative magnetic resonance imaging (MRI) findings. Needle entry accuracy provided by the two groups was determined by comparing the distance and angle measured by postoperative computed tomography with those measured by preoperative MRI. The duration and radiation exposure for determining the entry point were measured in the groups. Results: The new stereotactic guidance system and the conventional method provided similarly accurate entry points for discography and consecutive PELD. However, the new stereotactic guidance system lowered the duration and radiation exposure for determining the entry point. Conclusions: The new stereotactic guidance system under fluoroscopy provided a reliable needle entry point for discography and consecutive PELD. Furthermore, it reduced the duration and radiation exposure associated with determining needle entry.

Should Cerebral Angiography Be Avoided within Three Hours after Subarachnoid Hemorrhage?

  • An, Hong;Park, Jaechan;Kang, Dong-Hun;Son, Wonsoo;Lee, Young-Sup;Kwak, Youngseok;Ohk, Boram
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.526-535
    • /
    • 2019
  • Objective : While the risk of aneurysmal rebleeding induced by catheter cerebral angiography is a serious concern and can delay angiography for a few hours after a subarachnoid hemorrhage (SAH), current angiographic technology and techniques have been much improved. Therefore, this study investigated the risk of aneurysmal rebleeding when using a recent angiographic technique immediately after SAH. Methods : Patients with acute SAH underwent immediate catheter angiography on admission. A four-vessel examination was conducted using a biplane digital subtraction angiography (DSA) system that applied a low injection rate and small volume of a diluted contrast, along with appropriate control of hypertension. Intra-angiographic aneurysmal rebleeding was diagnosed in cases of extravasation of the contrast medium during angiography or increased intracranial bleeding evident in flat-panel detector computed tomography scans. Results : In-hospital recurrent hemorrhages before definitive treatment to obliterate the ruptured aneurysm occurred in 11 of 266 patients (4.1%). Following a univariate analysis, a multivariate analysis using a logistic regression analysis revealed that modified Fisher grade 4 was a statistically significant risk factor for an in-hospital recurrent hemorrhage (p=0.032). Cerebral angiography after SAH was performed on 88 patients ${\leq}3$ hours, 74 patients between 3-6 hours, and 104 patients >6 hours. None of the time intervals showed any cases of intra-angiographic rebleeding. Moreover, even though the DSA ${\leq}3$ hours group included more patients with a poor clinical grade and modified Fisher grade 4, no case of aneurysmal rebleeding occurred during erebral angiography. Conclusion : Despite the high risk of aneurysmal rebleeding within a few hours after SAH, emergency cerebral angiography after SAH can be acceptable without increasing the risk of intra-angiographic rebleeding when using current angiographic techniques and equipment.

Evaluating the Usefulness of Rice Bolus Phantom in Tomotherapy: Phantom Study (토모테라피에서 쌀 볼루스 팬텀의 유용성 평가: 팬텀연구)

  • Kim, Dae-Gun;Jung, Jae-Hong
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.663-669
    • /
    • 2021
  • The purpose of this study was to evaluate the usefulness of the rice bolus for upper-lower extremity radiation therapy by Tomotherapy. The computed tomography images were obtained for air, water, and rice bolus. The average and standard deviation of the Hounsfield unit (HU) were measured for image evaluation. The conformity index (CI) and homogeneity index (HI) were calculated for dose distribution of the planning target volume (PTV) which was treated by direct mode with gantry angle (90 and 270 angle). The point dose of a total of ten axial planes was measured to confirm the different regions. The mean of HU was -999.72 ± 0.72 at the air. The water and rice bolus were -0.13 ± 1.65 and -170 ± 27.2, respectively. The CI (HI) of PTV was 0.96 (1.36) at the air. 0.95 (1.04) at the water bolus, and 0.95 (1.04) at the rice bolus. The maximum dose for air was 136 cGy which is about 32% higher than 103 cGy for water and 104 cGy for rice bolus. There was a statistical difference for point dose between air and water including rice bolus (p=0.04), however, no statistical difference between water and rice bolus (p=0.579).The rice bolus phantom for extremities radiation therapy could be not only the optimized dose distribution but also the convenience and equipment safety at Tomotherapy. However, additional research will be necessary to more accurately verify the clinical usefulness of rice bolus phantom due to not enough examination.

A Study on Enacting the Radiologic Technologist Act for the Civil Right to Health in Korea (건강권과 방사선사법 제정에 관한 고찰)

  • Lim, Chang-Seon
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.313-320
    • /
    • 2007
  • There are the Medical Radiation Health and Safety Act(the Patient Radiation Health and Safety Act, the Radiologic Technologist Act), the Medical Laboratory Technologist Act, the Physical Therapy Practice Act, and the Dental Hygienist Act, etc in America. However, Korea has only one Act for a medical radiologic technologist(including radiation therapy technologist, nuclear medicine technologist), medical laboratory technologist, physical therapist, occupational therapy examiner, dental hygienist, and so on. It is the Medical Technologist Act. Therefore, the Medical Radiation Health and Safety Act for a radiologic technologist(including radiation therapy technologist, nuclear medicine technologist) has to be enacted independently in Korea. It is the purpose of this Act to provide for the appropriate certification of persons using radioactive materials, equipment emitting ionizing radiation on humans or performing medical imaging for diagnostic and therapeutic purposes. In Korea, the radiologic technologist is a "fusion technologist" who is a person other than a licensed practitioner as a radiographer, radiation therapist, nuclear medicine technologist, computed tomography technologist, magnetic resonance technologist, mammographer, sonographer, medical dosimetrist, quality management technologist, etc. This Act will have some provisions related to the definitions, reserved title, scope of practice, specialized technologist, application for licensure, radiologic technology council, renewal, continuing education, the radiation control advisory commission, etc. This Act will ensure that quality radiation therapy treatments are delivered and that quality diagnostic information is presented for interpretation, which will lead to accurate diagnosis, treatment and cure. Accurate diagnosis can be provided only when a personnel is properly educated in technique, equipment operation and radiation safety. In the end, this Act will protect the civil right to health. By regulating the personnel responsible for performing those procedures, this Act will mean improved care for patients-higher quality images, improved accuracy, and less exposure to radiation.

  • PDF